Professional Documents
Culture Documents
Project Data: Project Name Project Number Author Description Date 04-Nov-23 Design Code EN
Project Data: Project Name Project Number Author Description Date 04-Nov-23 Design Code EN
Project Data: Project Name Project Number Author Description Date 04-Nov-23 Design Code EN
Project no:
Author:
Project data
Project name
Project number
Author
Description
Date 04-Nov-23
Design code EN
Material
Steel S 355, S 235
Concrete C28
1 / 14
Project:
Project no:
Author:
Design
Name Base plate connection type 1 (Tension)
Description
Analysis Stress, strain/ simplified loading
2 / 14
Project:
Project no:
Author:
Cross-sections
Name Material
13 -
S 235
I100x50x3.5x.4.8(Iw100x50)
3 / 14
Project:
Project no:
Author:
Cross-sections
Name Material Drawing
13 -
S 235
I100x50x3.5x.4.8(Iw100x50)
Anchors
Diameter fu Gross area
Name Bolt assembly
[mm] [MPa] [mm2]
M12 4.6 M12 4.6 12 400.0 113
Foundation block
Item Value Unit
CB 1
Dimensions 200 x 200 mm
Depth 2000 mm
Anchor M12 4.6
Anchoring length 150 mm
Shear force transfer Anchors
Check
Summary
Name Value Status
Analysis 100.0% OK
Plates 0.0 < 5.0% OK
Anchors 91.0 < 100% OK
Welds 11.1 < 100% OK
Concrete block Not calculated
Buckling Not calculated
4 / 14
Project:
Project no:
Author:
Plates
Thickness σEd εPl σcEd
Name Loads Status
[mm] [MPa] [%] [MPa]
COL-tfl 1 5.0 LE1 24.7 0.0 0.0 OK
COL-bfl 1 5.0 LE1 26.6 0.0 0.0 OK
COL-w 1 4.0 LE1 22.0 0.0 0.0 OK
BP1 10.0 LE1 42.8 0.0 0.0 OK
Design data
fy εlim
Material
[MPa] [%]
S 235 235.0 5.0
5 / 14
Project:
Project no:
Author:
Anchors
NEd VEd NRd,c VRd,c VRd,cp Utt Uts Utts
Shape Item Loads Status
[kN] [kN] [kN] [kN] [kN] [%] [%] [%]
Design data
NRd,s VRd,s
Grade
[kN] [kN]
M12 4.6 - 1 14.3 12.1
6 / 14
Project:
Project no:
Author:
γM s
= 14.3 kN ≥ NEd =
3.9 kN
NRk,s = c ⋅ As ⋅ fuk =
28.7 kN
Where:
c = 0.85 – reduction factor for cut thread
As = 84 mm2
– tensile stress area
γM s = 1.2 ⋅ ffuk
yk
≥ 1.4 , where:
7 / 14
Project:
Project no:
Author:
NRk,c
NRd,c =
γM c
0 Ac,N
NRk,c = NRk,c
⋅
A0c,N
⋅ ψs,N ⋅ ψre,N ⋅ ψec,N ⋅ ψM ,N =
15.7 kN
Where:
NEd,g = 7.9 kN – sum of tension forces of anchors with common concrete breakout cone area
0
NRk,c = 13.0 kN – characteristic strength of a fastener, remote from the effects of adjacent fasteners or edges of the
concrete member
0 = k1 ⋅ fc′ ⋅ h1.5
NRk,c ef , where:
ca,max = 70 mm – maximum distance from the anchor to one of the three closest edges
Ac,N = 32401 mm2 – concrete breakout cone area for group of anchors
A0c,N = 19600 mm2 – concrete breakout cone area for single anchor not influenced by edges
ψs,N = 1.00 – parameter related to the distribution of stresses in the concrete due to the proximity of the fastener to an
c
ψs,N = 0.7 + 0.3 ⋅ 1.5⋅h
ef
≤ 1 , where:
ψec,N = 1.00 – modification factor for anchor groups loaded eccentrically in tension:
ψecx,N = 2⋅e1 x,N = 1.00 – modification factor that depends on eccentricity in x-direction
1+
3⋅hef
ψecy,N = 2⋅e1 y,N = 1.00 – modification factor that depends on eccentricity in y-direction
1+
3⋅hef
ψM ,N = 1.00 – parameter accounting for the effect of a compression force between the fixture and concrete; this
parameter is equal to 1 if c < 1.5hef or the ratio of the compressive force (including the compression due
to bending) to the sum of tensile forces in anchors is smaller than 0.8
8 / 14
Project:
Project no:
Author:
2⋅z
ψM ,N = 2 − 3⋅h
ef
≥ 1 , where:
γM s
0
VRk,s = k7 ⋅ VRk,s =
20.2 kN
Where:
k7 = 1.00 – coefficient for anchor steel ductility
k7 = {
0.8, A < 0.08
, where:
1.0, A ≥ 0.08
0
VRk,s = 20.2 kN – the characteristic shear strength
0
VRk,s = k6 ⋅ As ⋅ fuk , where:
9 / 14
Project:
Project no:
Author:
VRk,c
VRd,c =
γM c
0 Ac,V
VRk,c = VRk,c
⋅
A0c,V
⋅ ψs,V ⋅ ψh,V ⋅ ψec,V ⋅ ψre,V =
10.2 kN
Where:
VEd,g = 1.0 kN
– sum of shear forces of anchors on common base plate
0
VRk,c = 10.7 kN – initial value of the characteristic shear strength of the fastener
0
VRk,c = k9 ⋅ dαnom ⋅ lfβ ⋅ fck ⋅ c1.5
1 , where:
0.5
α = 0.1 ⋅ ( clf1 )
= 0.14 – factor
lf = min (hef , 12 ⋅ d) = 144 mm – parameter related to the length of the fastener, where:
0.2
β = 0.1 ⋅ ( dnom
c1 )
= 0.07 – factor
fck = 28.0 MPa – concrete compressive strength
c1 = 70 mm – edge distance of fastener in direction 1 towards the edge in the direction of loading
c1 = 70 mm – edge distance of fastener in direction 1 towards the edge in the direction of loading
ψs,V = 0.90 – parameter related to the distribution of stresses in the concrete due to the proximity of the fastener to an
c2
ψs,V = 0.7 + 0.3 ⋅ 1.5⋅c
1
≤ 1 , where:
c1 = 70 mm – edge distance of fastener in direction 1 towards the edge in the direction of loading
c2 = 70 mm – edge distance of fastener perpendicular to direction 1 that is the smallest edge distance
ψh,V = 1.00 – modification factor for anchors located in a shallow concrete member:
0.5
ψh,V = ( 1.5⋅c
h )
1
≥ 1 , where:
ψec,V = 1.00 – modification factor for anchor groups loaded eccentrically in shear:
1
ψec,V = 2⋅eV ≤ 1 , where:
1+
3⋅c1
c1 = 70 mm – edge distance of fastener in direction 1 towards the edge in the direction of loading
ψα,V = 1.12 – modification factor for anchors loaded at an angle with the concrete edge
10 / 14
Project:
Project no:
Author:
1
ψα,V =
(cos αV )2 +(0.5⋅sin αV )2
≥ 1 , where:
αV = 31.0 ° – angle between the applied load to the fastener or fastener group and the direction
ψre,V = 1.00 – parameter accounting for the shell spalling effect, no edge reinforcement or stirrups are assumed
VRk,cp
VRd,cp =
γM c
VRk,cp = k8 ⋅ NRk,c =
15.7 kN
Where:
k8 = 1.00 – factor taking into account fastener embedment depth
NRk,c = 15.7 kN – characteristic concrete cone strength for a single fastener or fastener in a group
Interaction of tensile and shear forces in steel (EN 1992-4 - Table 7.3)
2 2
( NNRd,s
Ed
) + ( VVRd,s
Ed
) =
0.08 ≤ 1.0
Where:
NEd = 3.9 kN – design tension force
Interaction of tensile and shear forces in concrete (EN 1992-4 - Table 7.3)
( NNRd,i
Ed
)1.5 + ( VVRd,i
Ed
)1.5 =
0.91 ≤ 1.0
Where:
NEd
– the largest utilization value for tension failure modes
NRd,i
VEd
– the largest utilization value for shear failure modes
VRd,i
NEd,g
NRd,c
= 89% – concrete breakout failure of anchor in tension
NEd
NRd,p
= 0% – concrete pullout failure
NEd
NRd,cb
= 0% – concrete blowout failure
VEd
VRd,c
= 15% – concrete edge failure
VEd
VRd,cb
= 9% – concrete pryout failure
11 / 14
Project:
Project no:
Author:
Design data
βw σw,Rd 0.9 σ
[-] [MPa] [MPa]
S 235 0.80 360.0 259.2
where:
fu = 360.0 MPa – Ultimate strength
Stress utilization
σ ∣σ⊥ ∣
Ut = max( σw,Ed ; )= 11.1 %
w,Rd
σ⊥,Rd
Buckling
Buckling analysis was not calculated.
Bill of material
Manufacturing operations
Plates Welds Length
Name Shape Nr. Bolts Nr.
[mm] [mm] [mm]
12 / 14
Project:
Project no:
Author:
Welds
Throat thickness Leg size Length
Type Material
[mm] [mm] [mm]
Double fillet S 235 3.0 4.2 190.0
Anchors
Length Drill length
Name Count
[mm] [mm]
M12 4.6 160 150 2
Drawing
BP1
P10.0x200-200 (S 235)
Code settings
Item Value Unit Reference
γM0 1.00 - EN 1993-1-1: 6.1
γM1 1.00 - EN 1993-1-1: 6.1
γM2 1.25 - EN 1993-1-1: 6.1
γM3 1.25 - EN 1993-1-8: 2.2
γC 1.50 - EN 1992-1-1: 2.4.2.4
γInst 1.20 - EN 1992-4: Table 4.1
13 / 14
Project:
Project no:
Author:
14 / 14