Project Data: Project Name Project Number Author Description Date 04-Nov-23 Design Code EN

You might also like

You are on page 1of 14

Project:

Project no:
Author:

Project data
Project name
Project number
Author
Description
Date 04-Nov-23
Design code EN

Material
Steel S 355, S 235
Concrete C28

1 / 14
Project:
Project no:
Author:

Project item Base plate connection type 1 (Tension)

Design
Name Base plate connection type 1 (Tension)
Description
Analysis Stress, strain/ simplified loading

Beams and columns


β– γ- α- Offset Offset Offset
Forces
Name Cross-section Direction Pitch Rotation ex ey ez
in
[°] [°] [°] [mm] [mm] [mm]
13 -
COL 0.0 -90.0 0.0 0 0 0 Node
I100x50x3.5x.4.8(Iw100x50)

2 / 14
Project:
Project no:
Author:

Cross-sections
Name Material
13 -
S 235
I100x50x3.5x.4.8(Iw100x50)

3 / 14
Project:
Project no:
Author:

Cross-sections
Name Material Drawing

13 -
S 235
I100x50x3.5x.4.8(Iw100x50)

Anchors
Diameter fu Gross area
Name Bolt assembly
[mm] [MPa] [mm2]
M12 4.6 M12 4.6 12 400.0 113

Load effects (equilibrium not required)


N Vy Vz Mx My Mz
Name Member
[kN] [kN] [kN] [kNm] [kNm] [kNm]
LE1 COL 7.4 0.3 -1.0 0.0 0.0 0.0

Foundation block
Item Value Unit
CB 1
Dimensions 200 x 200 mm
Depth 2000 mm
Anchor M12 4.6
Anchoring length 150 mm
Shear force transfer Anchors

Check

Summary
Name Value Status
Analysis 100.0% OK
Plates 0.0 < 5.0% OK
Anchors 91.0 < 100% OK
Welds 11.1 < 100% OK
Concrete block Not calculated
Buckling Not calculated

4 / 14
Project:
Project no:
Author:

Plates
Thickness σEd εPl σcEd
Name Loads Status
[mm] [MPa] [%] [MPa]
COL-tfl 1 5.0 LE1 24.7 0.0 0.0 OK
COL-bfl 1 5.0 LE1 26.6 0.0 0.0 OK
COL-w 1 4.0 LE1 22.0 0.0 0.0 OK
BP1 10.0 LE1 42.8 0.0 0.0 OK

Design data
fy εlim
Material
[MPa] [%]
S 235 235.0 5.0

Overall check, LE1

5 / 14
Project:
Project no:
Author:

Strain check, LE1

Anchors
NEd VEd NRd,c VRd,c VRd,cp Utt Uts Utts
Shape Item Loads Status
[kN] [kN] [kN] [kN] [kN] [%] [%] [%]

A5 LE1 3.9 0.5 8.7 6.8 10.5 89.8 15.1 91.0 OK

A6 LE1 3.9 0.5 8.7 6.8 10.5 89.8 15.1 91.0 OK

Design data

NRd,s VRd,s
Grade
[kN] [kN]
M12 4.6 - 1 14.3 12.1

6 / 14
Project:
Project no:
Author:

Detailed result for A5


Anchor tensile resistance (EN1992-4 - Cl. 7.2.1.3)
NRk,s
NRd,s =

γM s​

​ = 14.3 kN ≥ NEd =
​ 3.9 kN

NRk,s = c ⋅ As ⋅ fuk =
​ ​ ​
28.7 kN

Where:
c = 0.85 – reduction factor for cut thread
As = 84 mm2
​ – tensile stress area

fuk = 400.0 MPa – minimum tensile strength of the bolt


γM s = 2.00 ​ – safety factor for steel

γM s = 1.2 ⋅ ffuk

yk
≥ 1.4 , where:


fyk = 240.0 MPa – minimum yield strength of the bolt


7 / 14
Project:
Project no:
Author:

Concrete breakout resistance of anchor in tension (EN1992-4 - Cl. 7.2.1.4)


The check is performed for group of anchors that form common tension breakout cone: A5, A6

NRk,c
NRd,c =

γM c ​

​ = 8.7 kN ≥ NEd,g = ​ 7.9 kN

0 Ac,N
NRk,c = NRk,c
​ ⋅ ​

A0c,N


​ ⋅ ψs,N ⋅ ψre,N ⋅ ψec,N ⋅ ψM ,N = ​ ​ ​ ​

15.7 kN

Where:
NEd,g = 7.9 kN ​ – sum of tension forces of anchors with common concrete breakout cone area
0
NRk,c = 13.0 kN – characteristic strength of a fastener, remote from the effects of adjacent fasteners or edges of the

concrete member

0 = k1 ⋅ fc′ ⋅ h1.5
NRk,c ef , where:
​ ​ ​ ​ ​

k1 = 7.70 – parameter accounting for anchor type and concrete condition


fc′ = 28.0 MPa – concrete compressive strength


hef = min(hemb , max( ca,max smax


1.5 , 3 )) = 47 mm – depth of embedment, where:
​ ​


hemb = 150 mm – anchor length embedded in concrete ​

ca,max = 70 mm – maximum distance from the anchor to one of the three closest edges ​

smax = 85 mm – maximum spacing between anchors ​

Ac,N = 32401 mm2 – concrete breakout cone area for group of anchors

A0c,N = 19600 mm2 – concrete breakout cone area for single anchor not influenced by edges

A0c,N = (3 ⋅ hef )2 , where:


hef = 47 mm – depth of embedment ​

ψs,N = 1.00 – parameter related to the distribution of stresses in the concrete due to the proximity of the fastener to an

edge of the concrete member:

c
ψs,N = 0.7 + 0.3 ⋅ 1.5⋅h

ef
≤ 1 , where: ​

c = 70 mm – minimum distance from the anchor to the edge


hef = 47 mm – depth of embedment ​

ψre,N = 0.73 – parameter accounting for the shell spalling:


ψre,N = 0.5 + h200


emb
​ ≤ 1 , where: ​

hemb = 150 mm – anchor length embedded in concrete


ψec,N = 1.00 – modification factor for anchor groups loaded eccentrically in tension:

ψec,N = ψecx,N ⋅ ψecy,N , where:


​ ​ ​

ψecx,N = 2⋅e1 x,N = 1.00 – modification factor that depends on eccentricity in x-direction
​ ​

1+

3⋅hef

ex,N = 0 mm – tension load eccentricity in x-direction


ψecy,N = 2⋅e1 y,N = 1.00 – modification factor that depends on eccentricity in y-direction
​ ​

1+

3⋅hef

ey,N = 0 mm – tension load eccentricity in y-direction


hef = 47 mm – depth of embedment


ψM ,N = 1.00 – parameter accounting for the effect of a compression force between the fixture and concrete; this

parameter is equal to 1 if c < 1.5hef or the ratio of the compressive force (including the compression due
to bending) to the sum of tensile forces in anchors is smaller than 0.8

8 / 14
Project:
Project no:
Author:

2⋅z
ψM ,N = 2 − 3⋅h ​

ef
≥ 1 , where: ​

z = 1 mm – internal lever arm


hef = 47 mm – depth of embedment

γM c = 1.80 – safety factor for concrete


Shear resistance (EN1992-4 - Cl.7.2.2.3.1)


VRk,s
VRd,s =

γM s ​

​ = 12.1 kN ≥ VEd =​ 0.5 kN

0
VRk,s = k7 ⋅ VRk,s =
​ ​ ​
20.2 kN

Where:
k7 = 1.00 – coefficient for anchor steel ductility

k7 = {
0.8, A < 0.08
, where:
1.0, A ≥ 0.08
​ ​ ​

A = 0.22 – bolt grade elongation at rupture

0
VRk,s = 20.2 kN – the characteristic shear strength

0
VRk,s = k6 ⋅ As ⋅ fuk , where:
​ ​ ​ ​

k6 = 0.60 – coefficient for anchor resistance in shear


As = 84 mm2 – tensile stress area


fuk = 400.0 MPa – specified ultimate strength of anchor steel


γM s = 1.67 – safety factor for steel


9 / 14
Project:
Project no:
Author:

Concrete edge failure resistance (EN1992-4 - Cl. 7.2.2.5)


The check is performed for group of anchors that form shear breakout cones: A5, A6

VRk,c
VRd,c =

γM c ​

​ = 6.8 kN ≥ VEd,g = ​ 1.0 kN

0 Ac,V
VRk,c = VRk,c
​ ⋅ ​

A0c,V


​ ⋅ ψs,V ⋅ ψh,V ⋅ ψec,V ⋅ ψre,V =
​ ​ ​ ​

10.2 kN

Where:
VEd,g = 1.0 kN
​ – sum of shear forces of anchors on common base plate
0
VRk,c = 10.7 kN – initial value of the characteristic shear strength of the fastener

0
VRk,c = k9 ⋅ dαnom ⋅ lfβ ⋅ fck ⋅ c1.5

1 , where: ​ ​ ​ ​​ ​

k9 = 1.70 – parameter accounting for the state of the concrete


dnom = 12 mm – anchor diameter ​

0.5
α = 0.1 ⋅ ( clf1 ) ​


​ = 0.14 – factor
lf = min (hef , 12 ⋅ d) = 144 mm – parameter related to the length of the fastener, where:
​ ​

hef = 150 mm – anchor length embedded in concrete ​

dnom = 12 mm – anchor diameter ​

0.2
β = 0.1 ⋅ ( dnom
c1 ) ​

​ = 0.07 – factor
fck = 28.0 MPa – concrete compressive strength

c1 = 70 mm – edge distance of fastener in direction 1 towards the edge in the direction of loading

Ac,V = 21000 mm2 – actual area of idealised concrete break-out body


A0c,V = 22050 mm2 – reference projected area of failure cone


A0c,V = 4.5 ⋅ c21 , where:


​ ​

c1 = 70 mm – edge distance of fastener in direction 1 towards the edge in the direction of loading

ψs,V = 0.90 – parameter related to the distribution of stresses in the concrete due to the proximity of the fastener to an

edge of the concrete member:

c2
ψs,V = 0.7 + 0.3 ⋅ 1.5⋅c

1
≤ 1 , where: ​


c1 = 70 mm – edge distance of fastener in direction 1 towards the edge in the direction of loading

c2 = 70 mm – edge distance of fastener perpendicular to direction 1 that is the smallest edge distance

in a narrow member with multiple edge distances

ψh,V = 1.00 – modification factor for anchors located in a shallow concrete member:

0.5
ψh,V = ( 1.5⋅c
h )

1
≥ 1 , where: ​

h = 2000 mm – concrete member thickness


c1 = 70 mm – edge distance of fastener in direction 1 towards the edge in the direction of loading

ψec,V = 1.00 – modification factor for anchor groups loaded eccentrically in shear:

1
ψec,V = 2⋅eV ≤ 1 , where:
1+
​ ​

3⋅c1 ​

eV = 0 mm – shear load eccentricity


c1 = 70 mm – edge distance of fastener in direction 1 towards the edge in the direction of loading

ψα,V = 1.12 – modification factor for anchors loaded at an angle with the concrete edge

10 / 14
Project:
Project no:
Author:

1
ψα,V = ​

(cos αV )2 +(0.5⋅sin αV )2
​ ​
​ ​ ≥ 1 , where:
αV = 31.0 ° – angle between the applied load to the fastener or fastener group and the direction

perpendicular to the free edge under consideration

ψre,V = 1.00 – parameter accounting for the shell spalling effect, no edge reinforcement or stirrups are assumed

γM c = 1.50 ​ – safety factor for concrete

Concrete pryout resistance (EN1992-4 - Cl. 7.2.2.4)


The check is performed for group of anchors on common base plate

VRk,cp
VRd,cp = ​

γM c ​

​ = 10.5 kN ≥ VEd,g =​ 1.0 kN

VRk,cp = k8 ⋅ NRk,c = ​ ​ ​
15.7 kN

Where:
k8 = 1.00 ​ – factor taking into account fastener embedment depth
NRk,c = 15.7 kN – characteristic concrete cone strength for a single fastener or fastener in a group

γM c = 1.50 ​ – safety factor for concrete

Interaction of tensile and shear forces in steel (EN 1992-4 - Table 7.3)
2 2
( NNRd,s
Ed
) + ( VVRd,s

Ed
) = ​



0.08 ≤ 1.0

Where:
NEd = 3.9 kN ​ – design tension force

NRd,s = 14.3 kN – fastener tensile strength ​

VEd = 0.5 kN ​ – design shear force

VRd,s = 12.1 kN ​ – fastener shear strength

Interaction of tensile and shear forces in concrete (EN 1992-4 - Table 7.3)

( NNRd,i
Ed​

)1.5 + ( VVRd,i


Ed
)1.5 = ​



0.91 ≤ 1.0

Where:
NEd
– the largest utilization value for tension failure modes

NRd,i ​

VEd
– the largest utilization value for shear failure modes

VRd,i ​

NEd,g
NRd,c


​ = 89% – concrete breakout failure of anchor in tension
NEd
NRd,p


​ = 0% – concrete pullout failure
NEd
NRd,cb


​ = 0% – concrete blowout failure
VEd
VRd,c


​ = 15% – concrete edge failure
VEd
VRd,cb


​ = 9% – concrete pryout failure

11 / 14
Project:
Project no:
Author:

Welds (Plastic redistribution)


Throat th. Length σw,Ed εPl σ⏊ τ|| τ⏊ Ut Utc
Item Edge Loads Status
[mm] [mm] [MPa] [%] [MPa] [MPa] [MPa] [%] [%]
BP1 COL-tfl 1 ◢3.0◣ 50 LE1 29.9 0.0 6.1 -13.5 10.2 8.3 7.0 OK
◢3.0◣ 50 LE1 38.5 0.0 13.5 18.6 -9.4 10.7 6.7 OK
BP1 COL-bfl 1 ◢3.0◣ 50 LE1 39.9 0.0 14.8 -18.7 10.4 11.1 6.8 OK
◢3.0◣ 50 LE1 29.9 0.0 6.1 13.2 -10.6 8.3 7.1 OK
BP1 COL-w 1 ◢3.0◣ 90 LE1 24.8 0.0 12.3 1.9 12.3 6.9 4.3 OK
◢3.0◣ 90 LE1 24.8 0.0 12.3 -1.7 -12.3 6.9 4.3 OK

Design data

βw σw,Rd 0.9 σ
[-] [MPa] [MPa]
S 235 0.80 360.0 259.2

Detailed result for BP1 COL-bfl 1


Weld resistance check (EN 1993-1-8 4.5.3.2)
2
σw,Rd = fu /(βw γM 2 ) =
​ ​ ​ ​
360.0 MPa ≥ σw,Ed = [σ⊥
​ + 3(τ⊥2 + τ∥2 )]0.5 =
​ ​ ​
39.9 MPa

σ⊥,Rd = 0.9fu /γM 2 =


​ ​ ​
259.2 MPa ≥ ∣σ⊥ ∣ =

14.8 MPa

where:
fu = 360.0 MPa – Ultimate strength

βw = 0.80​ – appropriate correlation factor taken from Table 4.1

γM 2 = 1.25 ​ – Safety factor

Stress utilization
σ ∣σ⊥ ∣
Ut = max( σw,Ed ; )= 11.1 %

w,Rd ​

σ⊥,Rd ​

Buckling
Buckling analysis was not calculated.

Bill of material

Manufacturing operations
Plates Welds Length
Name Shape Nr. Bolts Nr.
[mm] [mm] [mm]

BP1 P10.0x200.0-200.0 (S 235) 1 Double fillet: a = 3.0 190.0 M12 4.6 2

12 / 14
Project:
Project no:
Author:

Welds
Throat thickness Leg size Length
Type Material
[mm] [mm] [mm]
Double fillet S 235 3.0 4.2 190.0

Anchors
Length Drill length
Name Count
[mm] [mm]
M12 4.6 160 150 2

Drawing

BP1

P10.0x200-200 (S 235)

Code settings
Item Value Unit Reference
γM0 1.00 - EN 1993-1-1: 6.1
γM1 1.00 - EN 1993-1-1: 6.1
γM2 1.25 - EN 1993-1-1: 6.1
γM3 1.25 - EN 1993-1-8: 2.2
γC 1.50 - EN 1992-1-1: 2.4.2.4
γInst 1.20 - EN 1992-4: Table 4.1

13 / 14
Project:
Project no:
Author:

Item Value Unit Reference


Joint coefficient βj 0.67 - EN 1993-1-8: 6.2.5
Effective area - influence of mesh size 0.10 -
Friction coefficient - concrete 0.25 - EN 1993-1-8
Friction coefficient in slip-resistance 0.30 - EN 1993-1-8 tab 3.7
Limit plastic strain 0.05 - EN 1993-1-5
Weld stress evaluation Plastic redistribution
Detailing No
Distance between bolts [d] 2.20 - EN 1993-1-8: tab 3.3
Distance between bolts and edge [d] 1.20 - EN 1993-1-8: tab 3.3
Concrete breakout resistance check Both EN 1992-4: 7.2.1.4 and 7.2.2.5
Use calculated αb in bearing check. Yes EN 1993-1-8: tab 3.4
Cracked concrete Yes EN 1992-4
Local deformation check No CIDECT DG 1, 3 - 1.1
Local deformation limit 0.03 - CIDECT DG 1, 3 - 1.1
Geometrical nonlinearity (GMNA) Yes Analysis with large deformations for hollow section joints
Braced system No EN 1993-1-8: 5.2.2.5

14 / 14