Professional Documents
Culture Documents
Standard Coils
Accessories
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD1
COILS DELTA POWER
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD2
COILS DELTA POWER
COIL DATA
STANDARD COILS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD3
COILS DELTA POWER
DESCRIPTION
1/2 inch (13 mm) I.D. Coil.
FEATURES
One piece encapsulated design that is:
• Weatherproof (when applied with o-rings)
• No external metal shell
COIL SPECIFICATION
ORDERING INFORMATION
P – – Approximate Coil Weight: .43 lbs (.19 kg)
TERMINATIONS VOLTAGE
AMP Superseal - Integral JA 12 12 VDC / 1.75 Amp
Double lead JL 24 24 VDC / .875 Amp
AMP Jr. Timer - Integral JJ
Metri-Pack - Integral JM
Deutsch - Integral DT04-2P JD
DIN 43650 (Hirschmann) JH
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD4
COILS DELTA POWER
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD5
COILS DELTA POWER
DESCRIPTION
Standard coil data P-Type coil 1/2’’ I.D.
FEATURES
One piece water resistant encapsulated design.
Note:
1. For coil selection in extreme conditions, please
look at our “I” coil line of environmental coils.
2. For PB-S2I, HB-S2C & HB-S2D use nut 36202090.
1.71
[43.5]
ORDERING INFORMATION
1.75
WHEN ORDERING Approximate Coil Weight: .72 lbs (.32 kg) [44.4]
FILL IN ALL BOXES P – ** – ** 1.75
[44.5]
.49 .81 .81 .87 1.11 .85
[12.4] [20.6] [20.6] [22.1] [28.3] [21.6]
BASIC MODEL NO. TERMINATION VOLTAGE
.85
(ALL COILS DC VOLTAGE EXCEPT AS NOTED)
[21.7]
DL Double Lead 06 6VDC
DT Deutsch on Leads DT04-2P, mates w/DT06-2S 12 12VDC
DI Deutsch - Integral DT04-2P, mates w/DT06-2S 24 24VDC LEAD WIRE CONNECTORS
ML Metri-Pack 150 Series on Leads (12162000), mates w/12052641 36 36VDC
MI Metri-Pack 150.2 Series - Integral (12066016), mates w/12162193 48 48VDC
P-Type One Piece PL Packard on Leads (12015792), mates w/12010973 25 24VAC
Encapsulated Coil WL Weather-Pack on Leads (12010973), mates w/12015792 11 110VAC
AL Amp Superseal 1.5 on Leads (282104.1), mates w/Amp 282080.1 & Metri-pack 12052641 13 125VAC
SS Single Spade 22 220VAC
DS Double Spade 23 250VAC
HC DIN 43650 (Hirschman) - (AC/DC) 44 440VAC
CL Conduit Lead - (AC ONLY)
19 WATT STD. COIL
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD6
COILS DELTA POWER
Double Lead AC
Description Double Single Double Single Hirschmann Lead Voltage
Wire
Lead Lead Spade Spade Connector Conduit Range
Color
Voltage 6VDC
ORANGE
Amp 3.5
Voltage 12VDC 12VDC 12VDC 12VDC 12VDC
YELLOW
Amp 1.6 1.6 1.6 1.6 1.6
Voltage 24VDC 24VDC 24VDC 24VDC
BLUE
Amp .78 .78 .78 .78
Voltage 36VDC 36VDC
GREEN
Amp .57 .57
Voltage 48VDC 48VDC
BROWN
Amp .40 .40
Voltage 24VAC 24VAC 24VAC BLUE/
Amp .92 .92 .92 BLACK
Voltage 110VAC 110VAC RED/ 100VAC
* * *
Amp .19 .19 WHITE 115VAC
Voltage 125VAC 125VAC 115VAC
* * RED *
Amp .17 .17 130VAC
Voltage 220VAC 220VAC BLACK/ 200VAC
* * *
Amp .10 .10 WHITE 230VAC
Voltage 250VAC 250VAC VIOLET/ 225VAC
* * *
Amp .08 .08 WHITE 260VAC
Voltage 440VAC 440VAC 400VAC
* * VIOLET *
Amp .05 .05 460VAC
SPECIFICATIONS
WATTAGE: 19 watts nominal.
DUTY RATING: continuous duty ±10% rated voltage at 120°F (49°C) ambient.
MINIMUM CURRENT FOR ACTUATION: 80% of rated current at room temperature.
MAGNET WIRE CLASS: N for all voltages.
TEMPERATURE RANGE: -40°F (-40°C) to 392°F (200°C)
LEAD WIRES: 18 gauge, 24” long, 600 Volt rating, with strain relief.
ENCAPSULATING MATERIAL: glass filled polyester, resistant to moisture, caustic solutions, fungus and vibration.
Temperature range is -40°F (-40°C) to 392°F (200°C).
COLOR IDENTIFICATION: black
NOTE: Delta Power A.C. Coils incorporate integrally molded full wave rectifiers which are rated for reverse voltage peaks of 1000
volts maximum.
A.C. Coils are rated 50/60 HZ.
* Optimum operating voltage noted.
Conduit connectors on A.C. coils have a maximum torque spec of 3 Ft. Lbs.
Arc Suppression Diode Available
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD7
COILS DELTA POWER
1.84 1.56
Reversible coil (can be installed on cartridges in
[46.6] [39.6]
both directions with equal efficiency).
Note:
For coil selection in extreme conditions, please
look at our “I” coil line of environmental coils.
2.03
[51.6]
1.75
DDL DDS DSS DHC DCL [44.4]
.49 .81 .49 .81 .81 .87 .81 1.11 .73 1.11
.85
[12.4] [20.6] [20.6] [28.3] [18.5] [28.2]
[12.4] [20.6] [20.6] [22.1] [21.6]
DMI
ORDERING INFORMATION LEAD WIRE CONNECTORS
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD8
COILS DELTA POWER
SPECIFICATIONS
WATTAGE: 22 watts nominal.
DUTY RATING: continuous duty ±10% rated voltage at 120°F (49°C) ambient.
MINIMUM CURRENT FOR ACTUATION: 80% of rated current at room temperature.
MAGNET WIRE CLASS: N for all voltages.
TEMPERATURE RANGE: -40°F (-40°C) to 392°F (200°C)
LEAD WIRES: 18 gauge, 24” long, 600 Volt rating, with strain relief.
ENCAPSULATING MATERIAL: glass filled polyester, resistant to moisture, caustic solutions, fungus and vibration.
Material temperature range is -40°F (-40°C) to 392°F (200°C).
COLOR IDENTIFICATION: black
NOTE: Delta Power A.C. Coils incorporate integrally molded full wave rectifiers which are rated for reverse voltage peaks of 1000
volts maximum.
A.C. Coils are rated 50/60 HZ.
* Optimum operating voltage noted.
Conduit connectors on A.C. coils have a maximum torque spec of 3 Ft. Lbs.
Arc Suppression Diode Available
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD9
COILS DELTA POWER
Note:
For coil selection in extreme conditions, please
look at our “I” coil line of environmental coils.
2.03
[51.6]
1.75
LDL LHC [44.4]
LDS LSS LCL
.49 .81 .49 .81 .81 .87 .81 1.11 .73 .85 1.11
[12.4] [20.6] [12.4] [20.6] [20.6] [22.1] [20.6] [28.3] [18.5] [21.6] [28.2]
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page 716
Page CD10
COILS DELTA POWER
Double Lead AC
Description Double Double Hirschmann Voltage
Spade Lead Wire
Lead Connector Conduit Color Range
Voltage 12VDC 12VDC 12VDC
YELLOW Data in this chart reflects
Amp 1.8 1.8 1.8
current usage. Additional
Voltage 24VDC 24VDC 24VDC
BLUE terminations, connections
Amp .9 .9 .9
Voltage
and suppression devices
GREEN are available.
Amp
Voltage Consult the factory for
BROWN
Amp special applications.
Voltage
BLUE/
Amp BLACK
Voltage 110VAC 110VAC RED/ 100VAC
* * *
Amp .16 .16 WHITE 115VAC
Voltage
115VAC
RED *
Amp 130VAC
Voltage 220VAC 220VAC BLACK/ 200VAC
* * *
Amp .08 .08 WHITE 230VAC
Voltage
VIOLET/ 225VAC
*
Amp WHITE 260VAC
Voltage
400VAC
VIOLET *
Amp 460VAC
SPECIFICATIONS
WATTAGE: 22 watts nominal.
DUTY RATING: continuous duty ±10% rated voltage at 120°F (49°C) ambient.
MINIMUM CURRENT FOR ACTUATION: 80% of rated current at room temperature.
MAGNET WIRE CLASS: N for all voltages.
TEMPERATURE RANGE: -40°F (-40°C) to 392°F (200°C)
LEAD WIRES: 18 gauge, 24” long, 600 Volt rating, with strain relief.
ENCAPSULATING MATERIAL: glass filled polyester, resistant to moisture, caustic solutions, fungus and vibration.
Material temperature range is -40°F (-40°C) to 392°F (200°C).
COLOR IDENTIFICATION: black
NOTE: Delta Power A.C. Coils incorporate integrally molded full wave rectifiers which are rated for reverse voltage peaks of 1000
volts maximum.
A.C. Coils are rated 50/60 HZ.
* Optimum operating voltage noted.
Conduit connectors on A.C. coils have a maximum torque spec of 3 Ft. Lbs.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD11
COILS DELTA POWER
DESCRIPTION
T-Type coil 3/4” I.D.
MODEL NO.
FEATURES 1.36 DELTA POWER
3/4" ID 1.80
[19.1] [45.7]
1.96
[49.7]
2.38
[60.6]
ORDERING INFORMATION
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD12
COILS DELTA POWER
Lead AC
Double Double Hirschmann
Description Wire Voltage
Lead Spade Connector
Color Range
Voltage 12VDC 12VDC 12VDC Data in this chart reflects
BLACK
Amp 2.33 2.33 2.33 current usage. Additional
Voltage 24VDC 24VDC 24VDC terminations, connections
RED
Amp 1.17 1.17 1.17 and suppression devices
Voltage 36VDC 36VDC 36VDC
are available.
BLUE Consult the factory for
Amp .78 .78 .78
Voltage special applications.
48VDC 48VDC 48VDC
GREEN
Amp .58 .58 .58
Voltage 25VAC RED/
25VAC
Amp 1.75 BLUE
Voltage
Amp
Voltage 120VAC RED/ 115VAC
Amp .31 BLUE 130VAC
Voltage
Amp
Voltage 240VAC RED/ 225VAC
Amp .15 BLUE 260VAC
Voltage
Amp
SPECIFICATIONS
WATTAGE: 28 watts nominal.
DUTY RATING: continuous duty ±10% rated voltage at 120°F (49°C) ambient.
MINIMUM CURRENT FOR ACTUATION: 80% of rated current at room temperature.
MAGNET WIRE CLASS: N for all voltages.
TEMPERATURE RANGE: -40°F (-40°C) to 392°F (200°C)
LEAD WIRES: 18 gauge, 24” long, 600 Volt rating, with strain relief.
ENCAPSULATING MATERIAL: glass filled polyester, resistant to moisture, caustic solutions, fungus and vibration.
Material temperature range is -40°F (-40°C) to 392°F (200°C).
COLOR IDENTIFICATION: black
NOTE: Delta Power A.C. Coils incorporate integrally molded full wave rectifiers which are rated for reverse voltage peaks of 1000
volts maximum.
A.C. Coils are rated 50/60 HZ.
* Optimum operating voltage noted.
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD13
COILS DELTA POWER
DESCRIPTION
T-Type coil 3/4” I.D.
FEATURES
One piece water resistant encapsulated design.
_________________________________________________________________________________________________
ORDERING INFORMATION
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD14
COILS DELTA POWER
SPECIFICATIONS
WATTAGE: 20 watts nominal.
DUTY RATING: continuous duty ±10% rated voltage at 120°F (49°C) ambient.
MINIMUM CURRENT FOR ACTUATION: 80% of rated current at room temperature.
MAGNET WIRE INSULATION: class H (200°C).
HEAT INSULATION: class H (180° C).
AMBIENT TEMPERATURE RANGE: -30°C +60°C
PROTECTION DEGREE: IP 65 (with connector and suitable seals).
LEAD WIRES: 600 Volt rating, with strain relief.
ENCAPSULATING MATERIAL: glass filled polyester, resistant to moisture, caustic solutions, fungus and vibration.
Metallic parts protected against oxidation.
A.C. coils do not include the rectifier, supply voltage must be externally rectified
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD15
COILS DELTA POWER
DESCRIPTION
1/2 inch (13 mm) I.D. Short Immersion Proof Coil.
1.48 FEATURES
[37.5]
One piece encapsulated design that is:
• Weatherproof
.98 • Immersion proof
[25.0]
PART • Thermal shock / dunk tested
• No external metal shell
1.48
[37.5]
XXXXXXXX XXXXX
DELTA POWER
COIL SPECIFICATION
1.70
[43.1] .98
[25.0]
Wattage 20 Watts Nominal
PART
Continuous Duty ±10% rated
Duty Rating
voltage at 120°F (49°C) ambient
XXXXXXXX XXXXX
VOLTAGE 1.54 Min Current for Actuation 80% of rated current at room temperature
DELTA POWER
[39.0]
1.70
[43.1]
Magnet Wire Class H or Better for all voltages
Temperature Range -40° to 392°F (-40° to 200°C)
.64 .82 .27
[20.8]degree[6.8] Up to IP 65
[16.4] .57 Protection .57
VOLTAGE 1.54 [14.5] (with connector
[14.4]
and suitable seals)
[39.0]
Encapsulation Material Thermo-Plastic, resistant to moisture,
DELTA POWER caustic solutions, fungus and vibrations
DELTA POWER
DELTA POWER
DELTA POWER
1.93
[49.1]
XXXXXXXX
XXXXXXXX
XXXXXXXX
2.05 XXXXXXXX
1.60
.64 [52.0] .82 [40.6]
[20.8] .27
[16.4] .57 [6.8]
[14.5] .57
.81 .82 .75 [14.4]
[20.6] [20.8] [19.0] .48
[12.1]
DELTA POWER
DELTA POWER
DELTA POWER
DELTA POWER
1.93
[49.1]
IA IJ IM
XXXXXXXX
XXXXXXXX
XXXXXXXX
2.05
ID
XXXXXXXX
1.60
[52.0] [40.6]
IA IJ ID IM
ORDERING INFORMATION
P – – Approximate Coil Weight: .43 lbs (.19 kg)
TERMINATIONS VOLTAGE
AMP Superseal 1.5 – Integral (282104.1), IA 12 12 VDC / 1.6 Amp Yellow Lettering
mates w/282080.1 & Metri-pack 12052641 24 24 VDC / .80 Amp Blue Lettering
Deutsch – Integral DT04-2P, mates w/DT06-2S ID
AMP Jr. Timer – Integral (84-9419) IJ NOTE: pull type valves require nut 36202073 in lieu of standard nut.
Metri-pack 150.2 Series – Integral (12066016), Push type valves require nut 36202071 in lieu of standard nut.
IM
mates w/12162193
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD16
COILS DELTA POWER
DESCRIPTION
1/2 inch (13 mm) I.D. Immersion Proof Coil.
1.48
[37.5] FEATURES
One piece encapsulated design that is:
.98 • Weatherproof
[25.0]
• Immersion proof
PART
1.48 • Thermal shock / dunk tested
[37.5]
• No external metal shell
XXXXXXXX XXXXX
DELTA POWER
.98
1.97 [25.0] COIL SPECIFICATION
[50.0]
PART
Wattage 24 Watts Nominal
Continuous Duty ±10% rated
Duty Rating
XXXXXXXX XXXXX
VOLTAGE 1.97
[50.0] 1.54 Min Current for Actuation 90% of rated current at room temperature
[39.0]
Magnet Wire Class H or Better for all voltages
Temperature
.82 Range -40° to 392°F (-40° to 200°C)
.64 .27
[20.8]
[16.4]
VOLTAGE 1.54
.57
[14.5]
Encapsulation Material
[6.8] Thermo-Plastic,
.57 resistant to moisture,
[39.0] caustic solutions,
[14.4] fungus and vibrations
2.20
[56.0] .64 .82
DELTA POWER
.27
DELTA POWER
DELTA POWER
DELTA POWER
[16.4] [20.8] 1.87
.57 2.32 [6.8] .57
[14.5] [47.5]
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
[59.0] [14.4]
[19.0]
DELTA POWER
DELTA POWER
DELTA POWER
2.32 1.87
[47.5]
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
[59.0]
1.08
[27.5]
IA 1.09
[27.7]
IJ 1.02
[26.0]
ID .75
IM
[19.0]
IA IJ ID IM
ORDERING INFORMATION
D – – Approximate Coil Weight: .49 lbs (.22 kg)
TERMINATIONS VOLTAGE
AMP Superseal 1.5 – Integral (282104.1), IA 12 12 VDC / 2.0 Amp Yellow Lettering
mates w/282080.1 & Metri-pack 12052641 24 24 VDC / 1.0 Amp Blue Lettering
Deutsch – Integral DT04-2P, mates w/DT06-2S ID
AMP Junior Timer - Integral (84-9419) IJ NOTE: pull type valves require nut 36202073 in lieu of standard nut.
Metri-pack 150.2 Series – Integral (12066016), IM Push type valves require nut 36202071 in lieu of standard nut.
mates w/12162193
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD17
COILS DELTA POWER
DESCRIPTION
5/8 inch (16 mm) I.D. Immersion Proof Coil.
1.48
[37.5]
FEATURES
One piece encapsulated design that is:
.98 • Weatherproof
[25.0]
1.48 • Immersion proof
PART # [37.5]
• Thermal shock / dunk tested
• No external metal shell
.98
XXXXXXXX
[25.0]
DELTA POWER
PART #
COIL SPECIFICATION
1.97
[50.0]
Wattage 26 Watts Nominal
XXXXX
Duty Rating
DELTA POWER
1.54
[39.0] Magnet Wire Class H or Better for all voltages
Temperature
.82
Range -40° to 392°F (-40° to 200°C)
.64
VOLTAGE
Encapsulation
[20.8] .27
Material Thermo-Plastic, resistant to moisture,
[16.4] 1.54
.57 [6.8] .57
[39.0] [14.5] caustic solutions, fungus and vibrations
[14.4]
.64 .82
2.20 [20.8] .27
[56.0] [16.4] .57 [6.8] .57
DELTA POWER
DELTA POWER
DELTA POWER
DELTA POWER
[14.5] 1.87
2.32 [14.4]
[47.5]
[59.0]
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
2.20
1.08 [56.0] 1.09 1.02
DELTA POWER
DELTA POWER
DELTA POWER
DELTA POWER
[27.5] [27.7] [26.0] .75
1.87
2.32
[47.5]
[19.0]
[59.0]
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
IA IJ ID IM
ORDERING INFORMATION
L – – Approximate Coil Weight: .49 lbs (.22 kg)
TERMINATIONS VOLTAGE
AMP Superseal 1.5 – Integral (282104.1), IA 12 12 VDC / 2.2 Amp Yellow Lettering
mates w/282080.1 & Metri-pack 12052641 24 24 VDC / 1.1 Amp Blue Lettering
Deutsch – Integral DT04-2P, mates w/DT06-2S ID
AMP Jr. Timer – Integral (84-9419) IJ NOTE: Pull type valves require nut 36202073 in lieu of standard nut.
Metri-pack 150.2 Series – Integral (12066016), Push type valves require nut 36202071 in lieu of standard nut.
IM
mates w/12162193
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD18
COILS DELTA POWER
CARTRIDGES COILS
Inspect the cartridge to assure there is no external contaminant It is sometimes easier to remove the coil from the cartridge
present. valve to install terminations or make connections with conduit,
Check O-rings and back-up rings to assure they are intact and etc. If this is the case, reinstall the coil by tightening the coil nut
in the correct position. The O-rings should always be toward to 4-6 ft lbs per spec sheet.
the high pressure port or between doubled back-up rings on CAUTION: DO NOT OVER TORQUE
bi-directional applications. Tube will be stretched and damaged, causing valve to fail.
TORQUE SPECIFICATIONS
Final Cartridge Tightening: Adjusting Holding Parts:
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD19
COILS DELTA POWER
MECHANICAL VALVES
The insertion codes for mechanical INSERTION
valves are CODES
based on the first seven digits of the valve mnemonic
DERVA0KE
code number. The eighth digit represents
M A RtheV direction
A 0 K Eof the view.
(END)
DERVA0KE
D EINSERTION
F C A 0 CODES 0 S DERVA0KE
INSERTION CODES (END)
M A R CODES
INSERTION V A 0 K E DERVA0KE (END)
M View
A R codes:
V A 0 K E DERVA0KE
Mnemonic INSERTION D E F CODES
C A 0 0 D SE F C A 0 0 S (END)
M A R V A 0 K E E = End (top) view (END)
MD AE RF VC AA 00 K0 ES F =View
Frontcodes:
or back viewView codes:
Always use 0 Mnemonic
(zero) D E F C A Mnemonic
0 0 S
S codes:
= Side view(top) view E = End (top) view
View E = End
Mnemonic View EndF(top)
E =codes: = Front
viewor back view
F = Front or back view
AlwaysMnemonic
use 0 (zero) Always use 0 (zero) EF==End (top)
S
Front view view
= Side
or back view S = Side view
Always use 0 (zero) FMnemonic
S==Front
Sideor back
view viewcodes:
option
Always use 0 (zero) S =0Side
= noview
visible options
K =Mnemonic
Knob Mnemonic option codes:
option codes:
Mnemonic option codes: 0 = no visible options DERVA0KF DERVA0KS
I = Internal
= noadjustment
0option visible options
Mnemonic codes:
0 = no visible options K = Knob
(FRONT) DERVA0KF(SIDE)
0K=T = visible
=no
Tamper
K = Knob
Knob options
proof I = Internal adjustment DERVA0KS
KI = I = Internal adjustment
T = Tamper proof DERVA0KF
DERVA0KFDERVA0KS
(FRONT) DERVA0KS (SIDE)
= Knob
Internal adjustment
IT
== T =adjustment
Internal
Tamper Tamper
proof proof DERVA0KF
(FRONT) (FRONT) DERVA0KS
(SIDE) (SIDE)
T = Tamper proof (FRONT) (SIDE)
SOLENOID VALVES
COIL VIEWS CODE
CODE
F D D L
CODE F D D L
View code: CODECODE Connector code: *
View code: F D D L Connector code: *
E = View
End (top) E = End (top) F D DF LD D L DLcode:
= Double Lead DL = Double Lead
code: Connector *
F =View
Front
View code:
E =code:
End (top) Series F =code:
Front Series code: Connector DL = SL = Single
Connector
code:
Double * Lead Lead * SL = Single Lead
code: BACK FRONT
BACK FRONT
* B = Back
E = End
FE==Front
End(top)
(top) M *=BMini
Series = Back
code: M = Mini DLSL =DS
= =DL
Double
SingleDouble
Lead Spade
= Double
Lead LeadDS = Double SpadeBACK FRONT
F =
R =* RightFront Series
PM R =code:
Right
Power
= Series P = Power SL =
DS SS Single
=SL
= Double Lead
Single Spade SS = Single BACK
Spade FRONT
BACK FRONT
BF ==Back
Front = Mini code: =Spade
Single Lead
* BR=
L = *Left=Back
Right AMP==L=Power
Mini
= Left
Power 4W3P Delta CoilA = Power 4W3P Delta DSSS=Coil
=Double
DP Single
=DS Spade
Spade
Double Post Spade DP = Double Post
B = Back M = Mini = Double
RL==Right PA==Power B = Power 4W3P SS
Power
DP ==Single
Coil
DoubleSpadePost SP = Single Post
R =Left
Right B = PowerPower
P = Power 4W3P Delta
4W3P Power Coil Coil SP =SS Single Post Spade
= Single
L = Left A = Power
Power4W3P4W3PDelta Coil
CoilD = Delta DPSP== Double
Single Post
Post HC = Hirschmann
L = Left D B= =Delta
A = Power
Power
4W3P Delta Coil HC =DP
Hirschmann
= Double PostCL = Conduit Lead
Delta 4W3P Power Coil L = Delta 4W3P SP
BD==Power HC==Single Post
Hirschmann
LD==Delta
B
L =Delta
Delta
4W3P 4W3P Power
= Power
4W3P T =Coil HC
Tecnord "D" Type ==CL
CLCoil
= SP
Conduit
Hirschmann
Conduit
Lead
Single
=Lead PostDC = Deutsch Integral Connector LEFT RIGHT
TLT===Tecnord "D" LEFT RIGHT RIGHT
D
Delta= Delta
4W3P
Tecnord "D" Type Coil H = Tecnord "T" Type
Type Coil CLDC =DC
Coil =HC
=ConduitDeutsch
Deutsch Lead Integral
=Integral
Hirschmann Connector
IA
Connector LEFT
= Integral Amp Superseal
HTH===Tecnord
LTecnord
= Delta
Tecnord "T"
"D" Type
4W3P
Type
"T" Coil
TypeCoil
Coil High Pressure DC IA ==IA CL Amp
Deutsch
Integral =Integral
= Integral Conduit
Amp Lead
Superseal
Connector
Superseal LEFT
ID = Integral Deutsch RIGHT
DELTA POWER
DDL12
12 VDC
THigh
= Tecnord
Tecnord Pressure "D"Coil
"T" Type Type Coil ID DCAmp
= Integral
IAID==Integral = Deutsch
Deutsch
Superseal Integral Connector
IM = Integral Amp Jr.
DELTA POWER
Integral Deutsch
DDL12
DDL12
12 VDC
12 VDC
S*S=The
=Super
High
SuperPressure IMMERSION
IMMERSION COILS
DELTA POWER
Hconnector
= Tecnord code"T"isType Coilfor back views IDIM==IM
not used Integral
= IA
IntegralDeutsch
Integral
=Amp AmpAmp
Integral
Jr. Jr. IM = Integral Metri-Pack
Superseal
DDL12
12 VDC
S = Super IMMERSION
COILS
COILS IM = Integral Amp Jr.
High Pressure
DELTA POWER
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
Page 726
Page 726
Page4484
726Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page 726
COILS DELTA POWER
CAVITIES PORTS
S E 1 2
N E 3 - 4
E 0 0 0 0 Port code:
S = SAE Size code
View code: N = NPT
E = End (top) Last four digits of NPT Examples:
View code: 1/16-27 = 1-16
S = Side form tool P/N. E = End (top) 3/4-14 = 3-4
H = Hidden (side)
S = Side 1 1/4-11 1/2 = 11-4
H = Hidden (side)
NE3-4 NS3-4
PLUGS
SAE PLUGS NPT PLUGS CAVITY PLUGS
1 2 S S 3 - 4 E N P E
Size code: View code: Size code: Series code: View code:
S = Side M = Mini F = Front
E = End (top) P = Power S = Side
D = Delta E = End (top)
T = Tecnord
S = Super
END SIDE
SIZES AVAILABLE SIZES AVAILABLE
#2 SAE #8 SAE #20 SAE 1/16" NPT 1" NPT
#3 SAE #10 SAE #24 SAE 1/8" NPT 1 1/4" NPT
#4 SAE #12 SAE #32 SAE 1/4" NPT 1 1/2" NPT
#5 SAE #14 SAE 3/8" NPT 2" NPT FRONT
#6 SAE #16 SAE 1/2" NPT
BODIES
D 2 W S
M 3 W N
Series code: Port code:
M = Mini S = SAE
P = Power N = NPT
D = Delta D2WS M3WN
T = Tecnord Style code:
S = Super 2W = two way
3W = three way
4W = four way
5W = five way
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD21
Page 727
COILS DELTA POWER
CARTRIDGE VALVES
INSERTION CODES
M A R VA 0 K
D E S 2 A0M
Mnemonic Mnemonic option codes:
Always use 0 (Zero) Mechanical valve options: Solenoid valve options:
0= No visible options 0= No visible options
K= Knob K= Manual override, Knob type
I= Internal adjustment I= Manual override
T= Tamperproof T= Manual override, Push only
COILS
INSERTION CODES
D ID
PDS
Series code: Coil termination:
M= Mini CL= Conduit lead
P= Power DI= Integral Deutsch DT04-2P
D= Delta, Tecnord & Super MI= Integral Metripack
L= Delta 4W3P DL= Double leads
T= Tecnord High Pressure DP= Double post
DS= Double spade
DT= Deutsch on leads DT04-2P
HC= DIN 43650 (Hirschmann)
ML= Metripack on leads (12162000)
WL= Weatherpack onleads (12010972)
IA= “I” coil, integral AMP Superseal
ID= “I” coil, integral Deutsch DT04-2P
IJ= “I” coil, integral AMP Jr. Timer
IM= “I” coil, integral Metripack
COIL NUTS
MINI Series: POWER, DELTA, TECNORD & SUPER Series: TECNORD High Pressure Series: 4W3P Coil nuts:
Normally open: 36202005 Normally open: 36202020 Normally closed: 36202059 Power Series: 36202047
Normally closed: 36202018 Normally closed: 36202017 Delta Series: 36202046
Normally open w/“I” coil: 36202071
Normally closed w/“I” coil: 36202073
BODIES
INSERTION CODES
D2WS
M3WN
Series code: Port code:
M= Mini S= SAE
P= Power N= NPT
D= Delta Style code:
T= Tecnord 2W= Two way
S= Super 3W= Three way
3WS= Three way short
4W= Four way
5WS= Five way short
CAVITY PLUGS
INSERTION CODES
DE00
SL00
Series code: Will always be 00 (Zero)
WARNING: the specifications/application data shown in our catalogs and data sheets are intended only as a general guide for the product described (herein). Any specific application should not be undertaken
W 7 / 2018
4484 Boeing Drive Rockford, IL 61109 • USA • Phone +1 (815) 397-6628 • Fax +1 (815) 397-2526 Via Malavolti, 36 • 41122 Modena • ITALY • Phone +39 (059) 254895 • Fax +39 (059) 253512
mail: delta@delta-power.com • www.delta-power.com mail: tecnord@tecnord.com • www.tecnord.com
Page CD22