SPR System Protection Relay


SPR System Protection, Control and Measurement Relay

The SPR system protection relay is a microprocessor based panel mounted device
offering protection, control, measurement and communication of up to 34 power
parameters in a single package. The SPR monitors three phases of voltage and
current and provides up to twelve user definable relay outputs. The high contrast 80
character backlit LCD display allows the user to monitor any of the measured
parameters, inspect setpoint details and relay contact status. The setpoints and
configuration are all fully programmable via the simple menu driven user interface,
and remote monitoring of status information is achievable via the integral RS 485
communication port which supports Modbus RTU protocol. SPR is suitable for
many applications, providing cost effective protection of expensive power assets.

Features Operation
Integrated protection, control, Using an alphanumeric display, the SPR is simple to operate. Only four buttons are
measurement and communication of up required to configure and control the product. All parameters can be inspected or
to 34 power parameters modified through front of panel menu selections. For security, alterations of any
Digital communications parameters can be disabled with up to four levels of password protection. The
Fully programmable VT and CT ratios default display is the status screen, where the status of each of the relays can be
Simple menu driven interface clearly identified. Any of the measurement screens can be made default. SPR can
also be remotely monitored and fully controlled over the RS485 Modbus connection.
High quality backlit LCD display
True RMS measurement
3 phase, 3 wire or 4 wire unbalanced Power Metering
load options
True RMS measurements (Root Mean Square) are continuously updated. The
12 protection relay functions
voltage, current and frequency signals are measured directly, while other
12 relay contacts outputs parameters, such as power (Watts, VAr, VA), are computed from this data. Current
Trip event history log inputs are given a very wide dynamic range in order to process overloads for time
Watchdog relay over current functions. Since the readings are true RMS, distorted waveforms are
accurately measured, leading to excellent harmonic performance.
Benefits Up to 34 true RMS power measurements can be made:
Replaces numerous traditional Voltage L1-N (L1-L2) Current L2 System Watts Phase Angle
protection relays Voltage L2-N (L2-L3) Current L3 System VAr Gen Frequency
Significant cost savings Voltage L3-N (L3-L1) Neutral Current System VA Bus Frequency
High accuracy Current L1 Ground Current Power Factor Gen-Bus Angle
Remote monitoring
Investment protection
Delinquency avoidance Output Relays
Compact and easy to configure The SPR has up to twelve sets of form C change over (NO+NC) relay contacts, each
Time and space saving rated at 8 Amps 250V A.C. These do not have fixed functions, allowing each relay to
be configured to suit a specific application, flexibility being the key to this product.
Applications Any function, or combination of functions, can be assigned to any relay. If additional
contact sets are required for any function, programmable logic allows the
General purpose system protection
parallelling of as many additional contacts as are available. The standard product
Switchgear has eight relays, but for the most demanding applications, four additional relays can
Distribution systems be supplied as an option. Each relay can be configured to energize, de-energize or
Generator sets latch on trip, as required.
Control panels
Utility power monitoring
Process control
Watchdog Relay
Motor control Following comprehensive self diagnostic checks at power-up, and once correct
operation has been verified, the dedicated change-over (NO+NC) relay contacts
Cable protection
energize to indicate product availability. The microprocessor continuously monitors
Feeder protection the relay system for healthy operation, and the contacts will de-energize if an
Automatic transfer switches internal fault is detected or the auxiliary supply is lost.
Railway

Approvals Event History Log


UL and CSA recognised File No. Every trip event is recorded in the history log. Events are itemised by date and time
E214283 stamp to a time resolution of 100ms, ideal for analysing the sequence of events
Railtrack Certificate of Acceptance leading up to a system fault. The internal real time clock has battery backup to
PA05/1450. Scope: Protective Device maintain the correct time and date for many years, even if the product is not
on Signalling Power Supply Systems powered up.

1
SPR System Protection, Control and Measurement Relay

Digital Communications
The built in RS485 communication port supports Modbus RTU protocol and offers
metering of Phase Voltages, Phase Currents, Watts, VAr, VA, Phase Angle, Power
Factor, Gen and Bus frequency, plus accessibility to all other features and functions
available through the front panel. Relay status and system measurements can be
interrogated, and relay parameters can be modified remotely.

The electrical interface is 2-wire RS485, which is fully floating. Modbus RTU supports
a maximum of 32 electrical nodes, which can be connected together as a network,
with a total maximum length in excess of 1200m (3500ft). Addresses can be set
between 1 and 247. The SPR is ideal for integration as part of high-level
management systems, such as SCADA. Remote metering is available using
Crompton software.

Specification

Current
Maximum Primary CT Value 10 kA A.C.
Continuous Current Rating 2 x Nominal
Short Duration Current 20 x Nominal (1 sec)
Maximum CT Burden < 0.6 VA
Relays
Relay Contact Rating 250V A.C./8 Amps
Max Breaking Capacity 2000VA
Contact Life to UL508 B 300/240V A.C./70°C
Relay Mechanical Life > 30 x 106
Voltage
Maximum Primary VT Value 400 kV A.C.
Continuous Voltage Rating 1.2 x Nominal
Short Duration Voltage 2 x Nominal (1 sec)
Maximum PT Burden < 0.2 VA
Auxiliary
Auxiliary Supply Nominal 24 V D.C.
Auxiliary Working Range 9 to 36 V D.C.
Auxiliary Burden < 20 VA
Environmental
Normal Operating Temperature 0°C to +50°C
Extended Operating Temperature Contact Factory
Storage Temperature -20°C to +70°C
Relative Humidity 95% non condensing
Shock 30g in 3 planes
Vibration 10 - 150 Hz @ 1g
Weight < 3kg
Dimensions 106mm high x 200mm wide x 176 mm
deep (max)
Panel Cut Out 187mm wide x 93mm high
Standards**
BS EN 50081-1 Emissions
BS EN 50082-2 Radiated
BS EN 61010-1 (IEC1010-1) Safety
BS EN 60255-4 (IEC255-4)
BS EN 60255-6 (IEC255-6)
ANSI/IEEE C37.90 UL508 Industrial Control Equipment
UL and CSA File No: E214283
Railtrack Certificate of Acceptance PA05/1450 Protective Device on
Signalling Power Supply Systems

** Please refer to operating manual for full details.

2
SPR System Protection, Control and Measurement Relay

Time Curves Relay Trip Parameters and Functions

Standard
StandardInverse
Inverse ANSI Description Parameter Range/Resolution/Accuracy
1000

Synchronism-Check Phase Difference 2 to 20 degrees/0.1 degrees/±1°


Monitoring
100 25 Slip Frequency 0.1 to 1 Hz/0.01 Hz/±0.03 Hz

Voltage Difference 0 to 20%/0.1 Volt/±2% nominal

TDS = 9.9
10 Synchronism-Check Phase Difference 2 to 20 degrees/0.1 degrees/±1°
Time (Seconds)

monitoring with
Dead Bus feature Slip Frequency 0.1 to 1 Hz/0.01 Hz/±0.03 Hz

1
25D Voltage Difference 0 to 20%/0.1 Volt/±2% nominal

Dead Bus Voltage 5 to 50%/0.1 Volt/±1% nominal

0.1
TDS = 0.5 Under Voltage Voltage Setpoint 20% to 120% Volts/0.1 Volt/±1% nominal
27 Relay
Diff 1 to 15% Volts/0.1 Volt/±1% nominal
0.01
10 100
Current (Multiple of trip setting)
Directional Power Power Setpoint 5 to 120% Watts/0.1 Watts/±3% nominal
32R (Reverse)
Diff 1 to 15% Watts/0.1 Watts/±1% nominal
Very Inverse
Very Inverse
1000
Phase Sequence No Parameters
47 Relay

100
Unbalanced Voltage Voltage Setpoint 1 to 25% Volts/0.1 Volts/±1% nominal
47 Relay
Diff 1 to 15% Volts/0.1 Volts/±1% nominal
TDS = 9.9
10
Time (Seconds)

AC Time Over Current Setpoint 5 to 120% Amps/0.01 A/±2.5% nominal


Current Relay with 3
Time Dial 0.1 to 9.9 sec/0.1 seconds/-
1 51 time curves
Time Curves Standard Inverse, Very Inverse,
Extremely Inverse

0.1
TDS = 0.5 AC Time Over Current Setpoint 5 to 120% Amps/0.01 A/±2.5% nominal
Current with
Restraint Voltage 80 to 120%/0.1 Volt/±1% nominal
Voltage Restraint
0.01 51V Time Dial 0.1 to 9.9 sec/0.1 seconds/-
10 100
Current (Multiple of trip setting)

Time Curve Standard Inverse, Very Inverse,


Extremely Inverse
Extremely
Extremely Inverse
Inverse
1000
Current Setpoint 5 to 120% Amps/0.01 A/±3% nominal
Neutral Ground
Fault Relay
51N Time Dial 0.1 to 9.9 sec/0.1 seconds/-
100
Time Curve Long time standby Earth Fault curve

TDS = 9.9
Voltage Setpoint 20 to 120% Volts/0.1 Volts/±1% nominal
Over Voltage Relay
10
59
Time (Seconds)

Diff 1 to 15%/0.1 Volts/±1% nominal

1 Frequency Setpoint 40 to 70 Hz/0.01 Hz/±0.03 Hz


Over Frequency
81O Relay Diff 0.1 to 10 Hz/0.01 Hz/±0.03 Hz

0.1
TDS = 0.5
Frequency Setpoint 40 to 70 Hz/0.01 Hz/±0.03 Hz
81U Under Frequency
Relay Diff 0.1 to 10 Hz/0.01 Hz/±0.03 Hz

0.01
10 100
Current (Multiple of trip setting)
All trip functions feature Latching, Alarm and Invert controls, plus Adjustable Time
Delay 0 to 30 seconds, Resolution 0.1 sec.

3
SPR System Protection, Control and Measurement Relay

Dimensions Wiring
The four current transformer inputs are fully isolated from Ground and from each
Front Display Area other, allowing the SPR to be used as an intermediate device or connected to a
common Ground as required. All electrical connections are made using two-part
200 (7.87”)
removable connecting blocks.

SPR-013W SPR-014W
3-Phase 3-Wire Unbalanced Load 3-Phase 4-Wire Unbalanced Load
106 (4.17”)

ESC

ENTER

SYSTEM PROTECTION RELAY

Side View
176 (6.93”)

168.7 (6.64”)

Auxiliary Supply
Designed to operate from 24V D.C. nominal engine batteries, operating normally at
106 (4.17”)

reduced voltage when the engine is cranking, and increased voltage when the
batteries are on charge. The switched mode auxiliary power supply has a very wide
operating range of 9 to 36 volts. A separate auxiliary module is available for other
auxiliary voltages. Please consult your sales centre for details.

Panel Cutout Safety / Ground Connections


187.0
+0.8
(7.36”)
+0.03” The ground stud on the rear panel should be connected to a clean ground. For safety
-0 - 0”
reasons, CT secondary connections should be grounded according to appropriate
codes of practice.
+0.03”
+0.03”

93.0 - 0 (3.66”) - 0”
(3.66”) - 0”

PANEL CUTOUT Product Codes


+0.8
+0.8
93.0 - 0

SPR – 01 4W – PQ LS – C6 – *BD – 08 – MB

Nominal Voltage Nominal Voltage Current Auxiliary Communications


4W = 4 Wire 3W = 3 Wire Power*
LS = 5 MB = Modbus RTU
Amp BD = 24 V D.C.
NU = 57.7 Volts L/N PK = 100 Volts L/L
NX = 63.5 Volts L/N PM = 110 Volts L/L
P7 = 127 Volts L/N PO = 115 Volts L/L
PA = 69 Volts L/N PQ = 120 Volts L/L
PK = 100 Volts L/N RM = 208 Volts L/L Frequency Relays
PM = 110 Volts L/N RU = 380 Volts L/L
PQ = 120 Volts L/N RW = 400 Volts L/L C5 = 50 Hz 08 = 8 x Relays
R4 = 220 Volts L/N SB = 415 Volts L/L C6 = 60 Hz 12 = 12 x Relays
RQ = 230 Volts L/N SD = 440 Volts L/L
RR = 240 Volts L/N SE = 480 Volts L/L
RS = 250 Volts L/N
R6 = 277 Volts L/N

* A separate auxiliary module is available for other auxiliary voltages.Please consult


your sales centre for details.

Order Code Example:


SPR-014W-PQLS-C6-BD-08-MB 4 wire product, 120 volts L/N, 5 Amp CTs,
60 Hz, Aux 24V DC, 8 relays and Modbus

4
© Tyco Electronics CI-RAILTRACK SPR-02/03

All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable.
Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular
quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth
in our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, BOWTHORPE EMP, CROMPTON INSTRUMENTS, DORMAN SMITH, DULMISON, GURO, HELLSTERN,
LA PRAIRIE, MORLYNN, RAYCHEM, and SIMEL are trademarks.

Energy Division – a pioneer in the development of economical solutions for


the electrical power industry. Our product range includes: Cable accessories,
connectors & fittings, electrical equipment, instruments, lighting, insulators &
insulation enhancement and surge arresters.

For more information and your country contact person, please visit us at:
http://energy.tycoelectronics.com