You are on page 1of 3

FTC Double Conversion Series

Specifications

Model FTC 4000 FTC 6000 FTC 8000 FTC 10K


Mode Micro-processor control fully Intelligent Double Conversion On-Line
Capacity
VA Rated 4000 6000 8000 10000
Watt Rated 3200 4800 6400 8000
Input
Voltage 160 - 245 V 160 - 245 V 1 - phase 160 - 245 V
3 - phase 380/220V + 15/-20%
Wiring Single phase: L-N + Ground 3 phase "Wye or Delta + Ground
Frequency 50/60 Hz +/- 5% tracking range
Output
Voltage Single phase: same as Input Nominal Single phase 208, 220, 230 or 240 V related to input
Regulation +/- 2 upon changes of line or load ; with +/- 10% adjustable range
Power factor 0,8-1 Lagging
Frequency 50/60 Hz +/- 0,5% (Free-running)
Waveform Pure Sineware; THD < 3% at Linear Load; < 5% at 0.7 P.F. load
Transient +/-4% under full load change, recovered within 100 milisecond
Synchronization 1 Hz/sec, slew rate; Interver Hz free running when I/P Hz over +/- 5%
Crest factor better than 3 : 1
Battery Lead-acid maintenance free, 3-5 years life time
Spec. 12V/7AH 16 pcs 12V/17AH 16 pcs 12V/26AH 16 pcs
Runtime (full/half) 12-14/30-35 min 20-22/40-50 10--12/25-30 18-20/40-50
Recharge to 90 % within 8 hours
Static Swicth Hybrid (triac+_relay) type with current-limited inrush protection
Auto Mode Active when inverter High/Low voltage, Inrush overload, Over Temperature & auto resumes
Manual Mode Push control keypad to manually transfer from inverter to bypass and vice versa
Control Panel
General Micro-computer to monitor & control system operation, log operation history & alarm messages
Control 8 keys ti manipulate: 1. Control On/Off of AC Input or System; Bypass loop activation
2. Display operating Status & Data. 3. Setting of System parameters. 4. Alarm reset
LCD Display Two lines 32 characters alphanumerical display provides
1. System operating Status (auto display). 2. Data such as O/P Volt., Amp., .etc
LED Display Utility status; On Battery. Inverter O/P; Bypass O/P; Overload, System Fault, Weak battery, Sync
Communication Port (DB9)
Signals provide both of serial signal for UPS software & contact closure signal for Novell/AS400 application
Application contact closure signal provides messages of UPS On/Bypass/Power Fail/Battery Low
Protection
Overload 120% 30 min.; 150% 25sec.
Shortcircuit Cut off outputs of both inverter & bypass never to trip House breaker
Thortcircuit Internal thermal switch to protect from over-temperature, then transfer to bypass loop
Circuit Breaker Protect AC input & battery loops
EMI Filter 10-100Khz at 40dB; 100Mhz at 70dB
Mechanical
Dimension (cm/in) 26x60x70/10.2x24x28 39x68x70/15.4x27x28 39x79x82/15.4x31.1x32.3 (WxDxH)*
Net Wt. (kgs/lbs) 96/211 185/407 220/484 280/616
Connection Hard-wiring for both input and output
Effectic Noise Inverter > 90%, System > 84%
Acoustic Noise <50dBA <55dBA <60dBA
Environment 0-40 degree C, 0-90% RH Non-condensing
Options
1. Intelligent UPS Software Package
2. Long Runtime Models: 4 amp. Charger - 35C1, 55C1 8 amp. Charger - 35C2, 55C2, 80C2
12 amp. Charger - 55C3, 80C3, 10KC3 (battery not included)*
3. Input Isolation Transformer for Universal input Voltage Selection
4. Socket Panel for installing U.S. twist-locking sockets.

*The dimension includes the height of casters.


*The above specification is subject to change without prior notice.
*All tradenames mentioned are the properties of their respective owners.
*Please consult with factory for battery application
*10KVA requires additional unit of battery bank.