BHL Type

Discrepancy Switch
Discrepancy Switch

BHL Type

Features
The rolling action of contact mechanism minimizes the Voltage in lamp circuits is widely available
part exposed to the arc, and ensure the long term among 24 V, 48 V, 110 V, 125 V, and 220 V.
contacting stability.

Breaking start Rolling action An LED lamp with built-in flicker circuit is
available. Turning the knob can start the
flickering action. *For the order of this type
refer to LXF (P.3 )

Completion of
Contacting start Rolling action contact The key lock mechanism is useful for
preventing un-authorized operations.
Both a cylinder (BHLC type) type and a
The breaking time is set as short as possible padlock (BHLP type) type are available.
by optimum cam design.

Rear terminal type (BHL-B type) enables


rapid wiring.
Nameplates may be selected in either a round type or
rectangular type style, which will be useful in your
panel design.
IP40 type is also available as the type
BHLFX. It can prevent external
penetration of foreign materials or
unexpected contact with a live part.
A protective grounding terminal is also
provided.
Rectangular (Y) type Round (Z) type

1
Specification (ratings, performance)
Type
Specification BHL / BHLS types
Rated insulation voltage 690 V
Rated current-carring capacity 20 A
Max. wire size 5.5 mm2
Screw size M4 x 9
Withstand voltage AC 2,500 V / 1 min.
Lighting impulse 4 kV
Contact resistance 50 m or less
Mechanical life 100,000 operations or more
Electrical life 500,000 operations or more
Shock resistance 500 m/s2 (6 directions) (300 m/s2 at the contact)
Vibration resistance Range of vibration: 10 to 150Hz, Acceleration : 20 m/s2, Time : 1 hour (3 directions)
Minimum power requirement AC 5 V 500 mA, DC 5V 100 mA (in good operating environment)
Operating temperature -20 to 60˚C
Storing temperature -40 to 70˚C
Service condition (altitude) 2,000 m or less

Breaking performance (electrical life of 10,000 operations)


Alternating current Direct current
Rated current Rated current Rated current Rated current 2 contacts used in series 2 contacts used in series
Rated voltage Rated voltage Rated current Rated current
(V) resistance load induction load (V) resistance load inductive load resistance load inductive load
(A) (A) (A) (A) (A) (A)
110 20 15 24 15 10 20 20
220 15 10 48 10 6 18 15
440 4 3 110 3 1.5 4.5 4
- - - 220 1.2 0.8 2 1.5
*Inductive For AC : Power factor 0.6 to 0.7
For DC : Time contact 40 ± 6 ms

Ratings Based on Overseas Standards (EN60947/IEC60947)


(1) Standard use conditions
No. Item Description Remarks
1 Operating temperature -5 to 40°C IEC60947-1 6.1.1
Maximum humidity of 50% at +40°C (For lower temperature than referenced
2 Humidity above, the maximum humidity shall not exceed 90% at +20°C) IEC60947-1 6.1.3
3 Altitude 2,000 m or less IEC60947-1 6.1.2

(2) Rating
No. Item Rating Remarks
1 Over-voltage category IEC60664-1 2.2.2.1.1
2 Degree of pollution Degree of pollution 3 IEC60947-5-1 6.1.3.2
3 Rated insulation voltage (Ui) 690 V IEC60947-1 4.3.1.2
4 Rated impulse withstand voltage 4 kV IEC60947-1 4.3.1.3
5 Utilization category and Designation Utilization category Ue(V) Ie(A)
rated operational voltage (Ue) 240 3
A600 AC-15
rated operational current (Ui) 100,000 operations or more* IEC60947-5-1 Annex A
*Electrical durability 250 0.55
P600 DC-13
20,000 operations or more*
6 Rated frequency 50/60 Hz IEC60947-5-1 4.3.3
7 Conventional free air thermal current (Ith) 20 A IEC60947-1 4.3.2.1
8 Maximum value of short circuit protection device 20 A IEC60947-5-1 8.3.4.3
9 Rated short circuit current with rated conditions 1000 A (cos =1) IEC60947-5-1 4.3.6.4
10 Mechanical durability 100,000 operations or more 60947-5-1 Annex C C.2

2
Discrepancy Switch

BHL Type
How to Order
Refer to the type code arrangements.

Type code arrangements

Basic type Voltage for indicator


Code Description Code Description
BHL Standard product 024 DC24 V
BHLS Small knob type 048 DC48 V
BHLC Cylinder lock type 110 DC110 V
BHLP Padlock type 125 DC125 V
BHL-B Rear terminal type 220 DC220 V
BHLFX Knob-fixed with housing protective grounding terminal

Indicator type
Operation BHL,
Code Description BHLS and others
Code Description H Incandescent lamp (built-in registor type)
1 2-point change-over L1 LED lamp (built-in registor type)
2 2-point change-over followed by pushing L2 * Connector-type LED lamp (built-in registor type)
3 2-point change-over followed by pushing and LXF Flicker-type LED lamp (built-in registor type)
turning to right or left *Specifications for L2 DC 24 V DC 48 are not available. means compatible.

Selectable positions Knob color


BHL,
Code Description Code Description BHLS and others

A Milky white (mask:silver, point:black)


W
Standard specification for models other than L2
B Clear,
C
Standard specification for L2
C
Milky white (mask:black, point:black)
WB
Special specification
D
means compatible.

E Flange shape and color


Code Shape Description

No. of units Y-B Square Black (N1.5)


Y-BG Square Blue-Green (7.5BG4/1.5)
Code Description
Z-B Round Black (N1.5)
1 to 6 1 to 6 [Max. 6 units (12 contacts)] Z-BG Round Blue-Green (7.5BG4/1.5)
(Munsell color code in parentheses)

Circuit number
Code Description
Please confirm the Type Comparison Table
Three-digit
(P9 to P10).
display
Please consult with our sales person.

3
Standard Specification Products
Discrepancy switch
BHL-1 Manual switching operation type
L(*1)
*The figure shows an LED type.

4- 5 hole 36
80 Panel t = 2.3 to 3.2 55
(5) 13 21
4
(2)

40

37
60
36

12
Knob
Flange Point Mask
Mounting hole Short bar (black colored) Y type (silver colored)

60.6

A B C D E
Z type
(*1)

No. of units 1 2 3 4 5 6

L(mm) 137 150 163 176 189 202

Discrepancy switch
BHL-2 Manual switching operation type (push lock at each position)
L(*1)
*The figure shows an LED type.

4- 5 hole 36
55
13 21 80 Panel t = 2.3 to 3.2
(5)
4
(2)
5 (stroke)
40

37
36

12
60

Knob
Flange Point Mask
Mounting hole Short bar (black colored) Y type (silver colored)
60.6

B C D E (*1) Z type

No. of units 1 2 3 4 5 6

L(mm) 197 210 223 236 249 262

Discrepancy switch
BHL-3 Manual switching operation type (90-deg. section)
Push auto return type (30-deg. section) L(*1)
*The figure shows an LED type.

4- 5 hole 36 Panel t = 2.3 to 3.2 55


80
(5) 13 21
4
(2)
5 (stroke)
40

37
60

12
36

Knob
Flange Point Mask
Mounting hole Short bar (black colored) Y type (silver colored)
60.6

B C D E Z type
(*1)

No. of units 1 2 3 4 5 6

L(mm) 137 150 163 176 189 202

4
Discrepancy Switch

BHL Type
Standard Specification Products
Compact discrepancy switch
BHLS-1 L(*1)
4- 5 hole 28 (5) 13 21 98 Panel t = 2.3 to 3.2 44

6-5
2-1

L1
4 (2)

L1
Terminal for lamp
30

28
44
28

60

L2
Knob Point Mask
(black colored)

7-8
3-4
L2
Flange (silver colored)
Mounting hole Resistance unit Y type
Terminal screw M4 x 9 50

Z type
(*1)

No. of units 1 2 3 4 5 6
L(mm) 155 168 181 194 207 220

Compact discrepancy switch


BHLS-2 4- 5 hole 28 (5) 13
L(*1)
21 98 Panel t = 2.3 to 3.2
44
2-1
6-5
L1

4 (2)
8(stroke)
L1
Terminal for lamp
30

28
28

44
60

L2

Knob Point Mask


7-8

(black colored) (silver colored)


L2

3-4

Mounting hole Flange


Y type
Resistance unit
50
Terminal screw M4 x 9

(*1) Z type
No. of units
2-point switching contacts 1 2 3 4
Depressing operation contacts 1 2 1 2 1 1
L(mm) 215 241 228 254 241 254
Compact discrepancy switch
BHLS-3 4- 5 hole 28 (5) 13 21
L(*1)
98 Panel t = 2.3 to 3.2
44
6-5
2-1
L1

4 (2)
5(stroke)
L1
Terminal for lamp
30

28
60

44
28

L2

Point Mask
Knob
(black colored) (silver colored)
7-8
3-4
L2

Mounting hole Resistance unit


Flange Y type
50
Terminal screw M4 x 9

(*1)
Z type

No. of units 1 2 3 4 5 6

L(mm) 155 168 181 194 207 220

5
With key lock mechanism
BHLC 36 4- 5 hole

40
36

50 0.2
Y type

19
.5
16
(*1)
Mounting hole
No. of units 1 2 3 4 5 6
L(mm) 158 171 184 197 210 223

*Keys "C-88 and C-110" are manufactured by Takigen. Z type


With padlock mechanism
BHLP 36
4- 5 hole

40
36

50 0.2

20.5 Y type

Mounting hole
(*1)

No. of units 1 2 3 4 5 6

L(mm) 158 171 184 197 210 223


Z type
*Padlock shall be prepared by the user. ( 6 padlock is acceptable)

With back rear terminal block


BHL-B 36
4- 5 hole 61 187.5(size with back terminal)
4

55
Depressing stroke 5
40

37
68
36

Y type
28
Panel t = 2 to 4
Mounting hole 60.6

*Max. unit No. : 3 (6 contacts)


Z type

Knob-fixed with housing protective grounding terminal (IP-40) (Panel surface protection type)
BHLFX 36
4- 5 hole
L(*1)
80
Panel t = 2.3 to 3.2
55
(5) 13 21
4
(2)
5 (stroke)
40

37
36

60

12

Knob
Point Mask
Mounting hole Flange (black colored) (silver colored) Y type
Short bar
60.6

(*1)

No. of units 1 2 3 4 5 6 Z type


L(mm) 137 150 163 176 189 202

6
Discrepancy Switch

BHL Type
Accessories

Nameplate (for BHL, BHLC, BHLP, BHL-B and BHLFX)


Square type Aluminum
A B C D E F G H I J K L M N O P
nameplate No.
(Y type)
L54-Y000 Plain (outline only)
53
47 L54-Y00B Black plain
L54-Y01E OPEN CLOSE CC OC
E
D F
C G
B H L54-Y02E IO IC C O
38
53

L54-Y03E O IO IC C
47

A I

P J L54-Y05E T C TC TT
O K
N L
M
L54-Y06E TT T C TC

4- 3hole
L54-Y07E PUSH PUSH CLOSE TRIP
L54-Y08E OPEN CLOSE
BHL-NP-L54-Y000 L54-Y11E PUSH PUSH CLOSE OPEN
Nameplate number
L54-Y12E PUSH CLOSE OPEN PUSH

Round type Aluminum


nameplate No. A B C D E F G H I J K L M N O P
(Z type)
L54-Z000 Plain (outline only)
4- 3hole
L54-Z00B Black plain
L54-Z01E OPEN CLOSE CC OC
E F
D
C G
B H L54-Z02E OPEN CLOSE
38
58.6

L54-Z03E IO IC C O
54

A I

P J L54-Z04E O IO IC C
O K
N L
M
L54-Z05E CLOSE OPEN
L54-Z06E OPEN CLOSE
54
L54-Z07E PUSH PUSH CLOSE OPEN
L54-Z08E TT T C TC
BHL-NP-L54-Z000
Nameplate number L54-Z09E T C TC TT
L54-Z10E T C
L54-Z11E PUSH PUSH CLOSE PUSH OPEN
L54-Z12E PUSH CLOSE OPEN

Nameplate (for BHLS)


Square type (Y type) Round type (Z type)
42
37 4- 3hole

E E F
D F D
C G C G
B H B H
29 29
43
37

48

A I A I

P J P J
O K O K
N L N L
M M

4- 3hole
43

BHLS-NP D54-000 BHLS-NP D54-Z000


Plain (outline only) Plain (outline only)

7
Accessories

Flange (nameplate) set :B(N1.5), BG(7.5BG 4/1.5)


BHL flange set Y BHL flange set Z
BHLS flange set Y BHLS flange set Z

Supplied screws 1) M4 x 10 countersunk 4 pcs. Supplied screws 1) M4 x 10 countersunk 4 pcs.


2) M2.6 x 4 tapping 4 pcs. 2) M2.6 x 4 tapping 4 pcs.

LED lamp (rated 24 V) Flicker LED lamp Incandescent lamp


E-12 LED lamp E-12 LED lamp E-12 LED lamp E-10 panel lamp
LD-24-YO LTH-024-12E-AY LXF-DC110-AY 110V2W
(BHLS only) Display color: Amber
Power supply voltage
Code Voltage
DC024 DC24V
DC048 DC48V
DC110 DC100/110V
DC125 DC125V
DC220 DC200/220V

Key System
For Cylinder Key C-110
(In case of master key used)

Grand master key (x 2 pieces) [Designated No.]

Grand master key (x 2 pieces) Grand master key (x 2 pieces)


[Designated No.] [Designated No.]
C-110
Key system is decided considering
Block A Block B the common use with door lock keys
or master keys.

Durability of a cylinder key and a


x 2 pieces x 2 pieces x 2 pieces x 2 pieces x 2 pieces x 2 pieces x 2 pieces x 2 pieces x 2 pieces x 2 pieces
Key Designated No.
cam rotor key are 10,000 cydes of
classification Block A taking out and putting in.
Key Blocks A Designated No.
classification and B

For Cylinder Key C-88


(When a master key is not needed)

x 2 pieces x 2 pieces x 2 pieces x 2 pieces x 2 pieces


Compatible
key K6510 only 1 type K6510 K6510 K6510 K6510
Key K6511
classification to K6520
10 types K6511 K6512 K6513 K6514

We will stamp key numbers on your request.

8
Discrepancy Switch

BHL Type
Contact Arrangement Table
Main contact arrangement table (please contact us for other contacts).

Type

7 8
5 6
Contact 3
1
4
2
3
1
4
2
arrangement L1 L2 L1 L2
L1 L2 L1 L2

Type

11 12
9 10
7 8 7 8
5 6 5 6
Contact 3
1
4
2
3
1
4
2
arrangement L1 L2 L1 L2
L1 L2 L1 L2

Type

11 12 11 12
9 10 9 10
7 8 7 8
5 6 5 6
Contact 3
1
4
2
3
1
4
2
arrangement L1 L2 P N
L1 L2 P N

9
Contact Arrangement Table

Type

15 16
13 14
11 12 11 12
9 10 9 10
7 8 7 8
5 6 5 6
Contact 3
1
4
2
3
1
4
2
arrangement L1 L2 L1 L2
L1 L2 L1 L2

Type

15 16 15 16
13 14 13 14
11 12 11 12
9 10 9 10
7 8 7 8
5 6 5 6
Contact 3
1
4
2
3
1
4
2
arrangement L1 L2 L1 L2
L1 L2 L1 L2

Type

23 24
21 22
19 20
17 18
15 16 15 16
13 14 13 14
11 12 11 12
9 10 9 10
7 8 7 8
5 6 5 6
Contact 3
1
4
2
3
1
4
2
arrangement P N L1 L2
P N L1 L2

10
Offering quality assurance for control parts

(Head Office) 585 Higashihachiman-cho, Oike-dori Tominokoji Nishi-iru, Nakagyo-ku, Kyoto 604-0954, Japan
Phone +81-75-221-7978 / Fax +81-75-251-0425
(Kusatsu Factory) 3-4-1, Nomura, Kusatsu, Shiga 525-8521, Japan
Phone +81-77-562-1215 / Fax +81-77-562-1213
(Shin-Asahi Factory) 905-1, Aza-nishigawara, Ota, Shin-Asahi-cho, Takashima, Shiga 520-1512, Japan
Phone +81-740-25-6338 / Fax +81-740-25-6339

Please address inquiries to the following offices:


Sales Office 3-4-1, Nomura, Kusatsu, Shiga 525-8521, Japan
Phone +81-77-562-1215 / Fax +81-77-562-1213
Osaka Sales Office Koei Bldg. 3-2-2, Ekimae, Ibaraki, Osaka 567-0888, Japan
Phone +81-72-624-7175 / Fax +81-72-624-7235
Tokyo Sales Office Shibakoen denki Bidg. 1-1-12, Shibakoen, Minato-ku, Tokyo 105-0011, Japan
Phone +81-3-5401-3379 / Fax +81-3-5401-3047
URL: http://www.fujidk.co.jp/
E-mail: prod@fujidk.co.jp
Web EDI: http://edi.fujidk.co.jp
(Internet Sales)

Precautions
Be sure to use the product within the correct voltage and amperage ranges as stated in this manual.
Check connections carefully, as a faulty connection may lead to an accident.
Check for abnomalities such as breaks in the leads, etc. before using the product.
Avoid using the product in extreme environments such as in the presence of high temperatues.
high humidity, dust, corrosive gases, vibration, or shocks.
Please contact the manufacturer for advice before using the products for special applications.
When overheating or other preblems occurs, disconnect the power to prevent the voltage from being
applied.
Be sure to use compatible parts or tools during wire connection.
For further details about the precautions during use, please check the Product Specifications.

To facilitate technical improverments, we reserve the right to change the specifications and names of products without notice.
The contents described herein are correct as of January, 2007.