Professional Documents
Culture Documents
Discrepancy Switch
Discrepancy Switch
BHL Type
Features
The rolling action of contact mechanism minimizes the Voltage in lamp circuits is widely available
part exposed to the arc, and ensure the long term among 24 V, 48 V, 110 V, 125 V, and 220 V.
contacting stability.
Breaking start Rolling action An LED lamp with built-in flicker circuit is
available. Turning the knob can start the
flickering action. *For the order of this type
refer to LXF (P.3 )
Completion of
Contacting start Rolling action contact The key lock mechanism is useful for
preventing un-authorized operations.
Both a cylinder (BHLC type) type and a
The breaking time is set as short as possible padlock (BHLP type) type are available.
by optimum cam design.
1
Specification (ratings, performance)
Type
Specification BHL / BHLS types
Rated insulation voltage 690 V
Rated current-carring capacity 20 A
Max. wire size 5.5 mm2
Screw size M4 x 9
Withstand voltage AC 2,500 V / 1 min.
Lighting impulse 4 kV
Contact resistance 50 m or less
Mechanical life 100,000 operations or more
Electrical life 500,000 operations or more
Shock resistance 500 m/s2 (6 directions) (300 m/s2 at the contact)
Vibration resistance Range of vibration: 10 to 150Hz, Acceleration : 20 m/s2, Time : 1 hour (3 directions)
Minimum power requirement AC 5 V 500 mA, DC 5V 100 mA (in good operating environment)
Operating temperature -20 to 60˚C
Storing temperature -40 to 70˚C
Service condition (altitude) 2,000 m or less
(2) Rating
No. Item Rating Remarks
1 Over-voltage category IEC60664-1 2.2.2.1.1
2 Degree of pollution Degree of pollution 3 IEC60947-5-1 6.1.3.2
3 Rated insulation voltage (Ui) 690 V IEC60947-1 4.3.1.2
4 Rated impulse withstand voltage 4 kV IEC60947-1 4.3.1.3
5 Utilization category and Designation Utilization category Ue(V) Ie(A)
rated operational voltage (Ue) 240 3
A600 AC-15
rated operational current (Ui) 100,000 operations or more* IEC60947-5-1 Annex A
*Electrical durability 250 0.55
P600 DC-13
20,000 operations or more*
6 Rated frequency 50/60 Hz IEC60947-5-1 4.3.3
7 Conventional free air thermal current (Ith) 20 A IEC60947-1 4.3.2.1
8 Maximum value of short circuit protection device 20 A IEC60947-5-1 8.3.4.3
9 Rated short circuit current with rated conditions 1000 A (cos =1) IEC60947-5-1 4.3.6.4
10 Mechanical durability 100,000 operations or more 60947-5-1 Annex C C.2
2
Discrepancy Switch
BHL Type
How to Order
Refer to the type code arrangements.
Indicator type
Operation BHL,
Code Description BHLS and others
Code Description H Incandescent lamp (built-in registor type)
1 2-point change-over L1 LED lamp (built-in registor type)
2 2-point change-over followed by pushing L2 * Connector-type LED lamp (built-in registor type)
3 2-point change-over followed by pushing and LXF Flicker-type LED lamp (built-in registor type)
turning to right or left *Specifications for L2 DC 24 V DC 48 are not available. means compatible.
Circuit number
Code Description
Please confirm the Type Comparison Table
Three-digit
(P9 to P10).
display
Please consult with our sales person.
3
Standard Specification Products
Discrepancy switch
BHL-1 Manual switching operation type
L(*1)
*The figure shows an LED type.
4- 5 hole 36
80 Panel t = 2.3 to 3.2 55
(5) 13 21
4
(2)
40
37
60
36
12
Knob
Flange Point Mask
Mounting hole Short bar (black colored) Y type (silver colored)
60.6
A B C D E
Z type
(*1)
No. of units 1 2 3 4 5 6
Discrepancy switch
BHL-2 Manual switching operation type (push lock at each position)
L(*1)
*The figure shows an LED type.
4- 5 hole 36
55
13 21 80 Panel t = 2.3 to 3.2
(5)
4
(2)
5 (stroke)
40
37
36
12
60
Knob
Flange Point Mask
Mounting hole Short bar (black colored) Y type (silver colored)
60.6
B C D E (*1) Z type
No. of units 1 2 3 4 5 6
Discrepancy switch
BHL-3 Manual switching operation type (90-deg. section)
Push auto return type (30-deg. section) L(*1)
*The figure shows an LED type.
37
60
12
36
Knob
Flange Point Mask
Mounting hole Short bar (black colored) Y type (silver colored)
60.6
B C D E Z type
(*1)
No. of units 1 2 3 4 5 6
4
Discrepancy Switch
BHL Type
Standard Specification Products
Compact discrepancy switch
BHLS-1 L(*1)
4- 5 hole 28 (5) 13 21 98 Panel t = 2.3 to 3.2 44
6-5
2-1
L1
4 (2)
L1
Terminal for lamp
30
28
44
28
60
L2
Knob Point Mask
(black colored)
7-8
3-4
L2
Flange (silver colored)
Mounting hole Resistance unit Y type
Terminal screw M4 x 9 50
Z type
(*1)
No. of units 1 2 3 4 5 6
L(mm) 155 168 181 194 207 220
4 (2)
8(stroke)
L1
Terminal for lamp
30
28
28
44
60
L2
3-4
(*1) Z type
No. of units
2-point switching contacts 1 2 3 4
Depressing operation contacts 1 2 1 2 1 1
L(mm) 215 241 228 254 241 254
Compact discrepancy switch
BHLS-3 4- 5 hole 28 (5) 13 21
L(*1)
98 Panel t = 2.3 to 3.2
44
6-5
2-1
L1
4 (2)
5(stroke)
L1
Terminal for lamp
30
28
60
44
28
L2
Point Mask
Knob
(black colored) (silver colored)
7-8
3-4
L2
(*1)
Z type
No. of units 1 2 3 4 5 6
5
With key lock mechanism
BHLC 36 4- 5 hole
40
36
50 0.2
Y type
19
.5
16
(*1)
Mounting hole
No. of units 1 2 3 4 5 6
L(mm) 158 171 184 197 210 223
40
36
50 0.2
20.5 Y type
Mounting hole
(*1)
No. of units 1 2 3 4 5 6
55
Depressing stroke 5
40
37
68
36
Y type
28
Panel t = 2 to 4
Mounting hole 60.6
Knob-fixed with housing protective grounding terminal (IP-40) (Panel surface protection type)
BHLFX 36
4- 5 hole
L(*1)
80
Panel t = 2.3 to 3.2
55
(5) 13 21
4
(2)
5 (stroke)
40
37
36
60
12
Knob
Point Mask
Mounting hole Flange (black colored) (silver colored) Y type
Short bar
60.6
(*1)
6
Discrepancy Switch
BHL Type
Accessories
L54-Y03E O IO IC C
47
A I
P J L54-Y05E T C TC TT
O K
N L
M
L54-Y06E TT T C TC
4- 3hole
L54-Y07E PUSH PUSH CLOSE TRIP
L54-Y08E OPEN CLOSE
BHL-NP-L54-Y000 L54-Y11E PUSH PUSH CLOSE OPEN
Nameplate number
L54-Y12E PUSH CLOSE OPEN PUSH
L54-Z03E IO IC C O
54
A I
P J L54-Z04E O IO IC C
O K
N L
M
L54-Z05E CLOSE OPEN
L54-Z06E OPEN CLOSE
54
L54-Z07E PUSH PUSH CLOSE OPEN
L54-Z08E TT T C TC
BHL-NP-L54-Z000
Nameplate number L54-Z09E T C TC TT
L54-Z10E T C
L54-Z11E PUSH PUSH CLOSE PUSH OPEN
L54-Z12E PUSH CLOSE OPEN
E E F
D F D
C G C G
B H B H
29 29
43
37
48
A I A I
P J P J
O K O K
N L N L
M M
4- 3hole
43
7
Accessories
Key System
For Cylinder Key C-110
(In case of master key used)
8
Discrepancy Switch
BHL Type
Contact Arrangement Table
Main contact arrangement table (please contact us for other contacts).
Type
7 8
5 6
Contact 3
1
4
2
3
1
4
2
arrangement L1 L2 L1 L2
L1 L2 L1 L2
Type
11 12
9 10
7 8 7 8
5 6 5 6
Contact 3
1
4
2
3
1
4
2
arrangement L1 L2 L1 L2
L1 L2 L1 L2
Type
11 12 11 12
9 10 9 10
7 8 7 8
5 6 5 6
Contact 3
1
4
2
3
1
4
2
arrangement L1 L2 P N
L1 L2 P N
9
Contact Arrangement Table
Type
15 16
13 14
11 12 11 12
9 10 9 10
7 8 7 8
5 6 5 6
Contact 3
1
4
2
3
1
4
2
arrangement L1 L2 L1 L2
L1 L2 L1 L2
Type
15 16 15 16
13 14 13 14
11 12 11 12
9 10 9 10
7 8 7 8
5 6 5 6
Contact 3
1
4
2
3
1
4
2
arrangement L1 L2 L1 L2
L1 L2 L1 L2
Type
23 24
21 22
19 20
17 18
15 16 15 16
13 14 13 14
11 12 11 12
9 10 9 10
7 8 7 8
5 6 5 6
Contact 3
1
4
2
3
1
4
2
arrangement P N L1 L2
P N L1 L2
10
Offering quality assurance for control parts
(Head Office) 585 Higashihachiman-cho, Oike-dori Tominokoji Nishi-iru, Nakagyo-ku, Kyoto 604-0954, Japan
Phone +81-75-221-7978 / Fax +81-75-251-0425
(Kusatsu Factory) 3-4-1, Nomura, Kusatsu, Shiga 525-8521, Japan
Phone +81-77-562-1215 / Fax +81-77-562-1213
(Shin-Asahi Factory) 905-1, Aza-nishigawara, Ota, Shin-Asahi-cho, Takashima, Shiga 520-1512, Japan
Phone +81-740-25-6338 / Fax +81-740-25-6339
Precautions
Be sure to use the product within the correct voltage and amperage ranges as stated in this manual.
Check connections carefully, as a faulty connection may lead to an accident.
Check for abnomalities such as breaks in the leads, etc. before using the product.
Avoid using the product in extreme environments such as in the presence of high temperatues.
high humidity, dust, corrosive gases, vibration, or shocks.
Please contact the manufacturer for advice before using the products for special applications.
When overheating or other preblems occurs, disconnect the power to prevent the voltage from being
applied.
Be sure to use compatible parts or tools during wire connection.
For further details about the precautions during use, please check the Product Specifications.
To facilitate technical improverments, we reserve the right to change the specifications and names of products without notice.
The contents described herein are correct as of January, 2007.
EP BHL0701-50