You are on page 1of 8

System 800xA High Integrity


Emergency Shutdown Solution
2 S Y S T E M 8 0 0 X A H I G H I N T E G R I T Y E M E R G E N C Y S H U T D O W N S O LU T I O N


800xA High Integrity
Emergency Shutdown Solution

With 30 years of experience in designing, implementing and maintaining safety systems,


ABB provides a simpler, integrated application solution for Emergency Shutdown
systems.


An Emergency Shutdown (ESD) system prevents In addition, ABB provides a broad family of industry
Some of the world’s
largest offshore platforms or minimizes the consequences of emergency -specific libraries that contain Control Modules,
have emergency shut- situations, helping to avoid loss of human life, Function Blocks, Data Types and graphic elements
down and Fire & Gas
damage to the environment, and/or loss of including special safety systems features for ESD
solutions based on 800xA
High Integrity. equipment. applications. These pre-tested and safety-certified
libraries significantly reduce the time required to
System 800xA is ABB’s main control system engineer, test and maintain control while minimizing
offering in which 800xA High Integrity constitutes project risks.
the Safety Instrumented Systems (SIS) portion.
The ESD safety system can be fully integrated In compliance with traditional industrial risk a
­ nalyses
with the System 800xA Basic Process Control for ESD functions, these libraries are certified for
System (BPCS), thereby providing a common Safety Integrity Level 3 (SIL 3).
operational, engineering and information environ-
ment for BPCS and SIS. Note that the level of Based on the powerful graphical builder of S
­ ystem
integration is completely optional and ranges 800xA, ESD system visualization can be freely
from a completely stand-alone to a fully- designed and tailored to each specific installation.
integrated configuration, all enabled by the This provides the operator with an immediate
uniquely flexible System 800xA architecture. understanding of the relations between sets of
inputs (triggering events) and outputs (actions).
System 800xA includes a comprehensive library
of standard reusable components that include
­extended automation entities such as faceplates,
graphic elements, trends, document links and
alarms and events.
E M E R G E N C Y S H U T D O W N S O LU T I O N S Y S T E M 8 0 0 X A H I G H I N T E G R I T Y 3


01
From smaller systems for single processes to ESD Libraries
Predefined descriptive larger, hierarchical plant-wide solutions with ABB offers a wide range of control modules for
graphic displays of several safety levels, e.g. process-section shut- monitoring and controlling safety systems. A
common objects speed
up engineering work.
downs, total-process shutdowns and total-plant complete range of high-level Control modules,
shutdown, ABB provides a solution for Emergency Faceplates, Graphic Elements, Alarm manage-
— Shutdown systems. Integration of state-of-the- ment and operational templates and strategies
02
Function blocks with SIL-
art, certified products for ESD applications are included as part of the standard 800xA High
levels clearly indicated in utilizing standardized, high-performance plant Integrity offering.
the engineering network solutions with TÜV-approved AC 800M
environment.
High Integrity controllers results in a powerful The SIL3-certified Supervision Basic Library includes
and homogenous, ESD system. ABB provides a range of function blocks typically used in ESD
certified building blocks for ESD applications. ­applications. Easily identifiable safety-certified
This enhances functionality, increases safety ­function blocks provide engineers and operators
and considerably simplifies the engineering with a clear-cut visual separation between safety-
process. critical and process-control application code.

— —
01 02
4 S Y S T E M 8 0 0 X A H I G H I N T E G R I T Y E M E R G E N C Y S H U T D O W N S O LU T I O N


800xA High Integrity functionality

Diverse technology for maximum reliability Access management


The AC 800M HI offers a SIL3 TÜV certified control Access Control, Confirm Operation and Force
environment for combining safety and business Control are all firewall mechanisms embedded
critical process control in one controller without within the safety controller. Access control to SIL
sacrificing safety integrity. The AC 800M High applications includes functionality for configura-
Integrity controller is realized by combining tion, operation and maintenance. In accordance
different technologies in the processor module with several safety standards, a physical input
and the Safety Module (co-processor). implemented as a hard-wired signal to the safety
controller must be activated to enable the highest
Fault tolerance for maximum availability level of authorized access. When the Access Enable
Flexible redundancy schemes enable controller input is actived, permission is given to make online
configurations up to and including Quad configu- changes in a SIL application.
ration. Libraries are marked non-SIL or SIL to
show their usability. Embedded safety measures High Integrity I/O
prevent inadvertant degradation of safety System 800xA’s S800 I/O is a distributed, highly
applications. -modular and flexible I/O system that allows easy
installation of I/O modules and process cabling.
Flexible integration to System 800xA SIL3-compliant High Integrity I/O modules within
800xA High Integrity and System 800xA utilize the S800 I/O family can be used for safety-critical
common ­engineering tools as well as operator applications. These I/O modules include those for
interface, ­historian, audit trail, asset and device 4-20 mA analog inputs, 24 Vdc supervised digital
management applications and instruments. This inputs and 24 Vdc digital outputs. The digital out-
enables system-level tools and functions to be put module provides both Normally Energized and
leveraged across an entire integrated plant auto- Normally Deenergized outputs typically used in
mation solution, including the safety system. ESD and Fire & Gas (F&G) systems respectively.
Such an environment offers safe and instant The digital inputs support local time-tagging of
interaction between applications, which leads signal changes for high-resolution sequence-of-
— to a host of benefits, including easier handling events logging. Analog inputs support HART pass
Process control and
through better technical solutions and reduced -through for easy calibration, monitoring and
safety systems can be
seamlessly integrated in cost of ownership throughout the system life diagnosis with configurable access when using
System 800xA. cycle. HART device integration.

— — —
Panel 800 System Extended Plant Networks,
Workplaces Operator Workplace ERP, CMMS ...

System Servers

System Network (optionally redundant)

AC 800M Combined BPCS (Basic Safety


Safeguard
Controller(s) Process Control System) High Integrity
400 Series
and Safety High Interity Controller(s)
Controller(s)
Fieldbus
Optical Modulebus
Optical Modulebus
(optionally redundant)
(optionally redundant)
Positioner
Optical Modulebus

S800L & S800 I/O S800 I/O w. S800 I/O w.


High Integrity High Integrity Pressure
PROFIBUS (optionally redundant)

Module(s) Module(s) Transmitter


2600 T

S800L & S800 I/O

Fire & Gas Shut-down

S900 I/O for use


in hazardous environments
E M E R G E N C Y S H U T D O W N S O LU T I O N S Y S T E M 8 0 0 X A H I G H I N T E G R I T Y 5

— —
Engineering Operations

Read only Confirm


Confirm operation
Confirm & Dialog box
access enable

Control Network

Logic solver

f i r m wr it e
Co n


S I L ac c e ss 02

Access enable
SIL
Access disable
application

Any force active

SIL access

Force control

Field connections

— —
01 03


Force Control High Integrity instrumentation
01
Embedded firewalls and Force Control in the 800xA High Integrity system ABB can provide a wide range of safety-certified
confirmation procedures has been implemented to support all operational, sensors and positioners. Various solutions are
protect the SIL application
engineering, maintenance and management available ranging from full-redundancy, high-
from inadvertent/
accidental control actions. ­activities throughout the system life cycle. When integrity transmitters designed and certified by
designing SIL applications, the safety engineer TÜV to comply with IEC 61508 requirements to

defines the maximum number of concurrent standard transmitters with enhanced internal
02
AC 800M High Integrity forced inputs and outputs. During operation and diagnostics to minimize the ­Probability of Failure
controller is SIL3-certified maintenance, the Access Management software on Demand.
both in single and redun-
restrict access to SIL applications to prevent
dant configurations.
unauthorized changes, additionally keeps track
— of the active number of forced I/O points. This
03
information can be made available via the safety
ABB’s range of safety-
certified instruments operator’s personalized workplace.
includes flow, pressure,
temperature, etc.
For emergency reset of all forces, a firmware func-
tion that includes a dedicated physical input is
available in the safety controller. This complies
with regulatory requirements and reduces time-
consuming application design, implementation
and testing.
6 S Y S T E M 8 0 0 X A H I G H I N T E G R I T Y E M E R G E N C Y S H U T D O W N S O LU T I O N


System 800xA functionality

Functional Safety Management via Aspect Sequence of Events (SOE) and Alarms
Objects platform Alarms and time-tagged Event messages are stored
The framework of the 800xA High Integrity system and presented with milli-second accuracy in alarm
environment is built on ABB’s Aspect Object tech- lists and SOE displays. This standard feature of
nology. Managing data within this singular virtual the 800xA system constitutes a powerful tool to
database environment, System 800xA makes all quickly identify the root cause should a shutdown
the information required to install, operate and or hazardous event occur. In an integrated BPCS
maintain the system available through a common and SIS system configuration, common SOE
interface. This makes it possible to access data handling across the process control and safety
(aspects) directly from its source in the context of systems enables faster and safer process start-
the asset (object) without needing to know where up in the event of a shutdown.
the data comes from, and without concerns
about data integrity and concordance. Messaging
Remote personnel are notified of critical events
System 800xA’s system platform opens new per- via mobile telephones, e-mail accounts and pagers
spectives during the design and realization of by the system’s SMS (Simple Messaging Service)
safety and control applications, as well as during and e-mail messaging service. Using GSM (Global
— Functional Safety Management (FSM) and other System for Mobile communications) mobile phone
01
safety-related support functions. technology, 800xA allows remote acknowledgement
Dedicated safety work-
places offer overviews of notification and confirmation of receipt.
as well as easy access to For example, safety aspects could include hazardous
detailed information.
operation studies, safety-requirement specifica-
— tions, safety allocation specifications, SIL Assess-
02 ments, ­installation and test support, maintenance,
Top-of-the-line operator
modifications and change management, configu-
environment for safe
operation and informed ration management as well as SIL monitoring,
decision-making. validation and verification.

— —
01 02
E M E R G E N C Y S H U T D O W N S O LU T I O N S Y S T E M 8 0 0 X A H I G H I N T E G R I T Y 7

— System 800xA Information Management report contains an over-view of all shutdowns


ABB’s ESD solutions help
System 800xA collects and securely stores performed in the system, and gives the opera-
prevent emergency
situations in the chemical business, process and safety data from all plant tor detailed information of cause and effect
industry. sources. Due to the powerful and flexible system relationships, including status
functionality and features, this data can be analyzed of the operations performed.
and transformed into useful information, and
presented to plant-users to improve operational On-line diagnostics
efficiency, safety and profitability. Examples of Each safety controller in the 800xA High Integrity
safety compliance reports that can be created system issues detailed messages about safety-
include: related information and problems. These are
typically monitored through the operator station.
• Override Report. This high level of diagnostics is essential for the
Shows an overview of all tags that are currently integrity of the ESD. System Status and Asset
in force, blocked, suppressed or in override, etc. Viewers provide detailed information about the
In combination with the standard System health and location of every device in the safety
800xA Audit Trail functionality, the report also system.
enables historical reviews of when or by whom a
tag was blocked or suppressed. Personalized workplaces for safety personnel
The library modules typically used for BMS appli-
• Valve Verification Report. cations provide a set of easily-configured operator
Summarizes valve functionality in the system. displays and dialogs. These displays can be
This report contains valve operation informa- organized in a hierarchical structure with an over-
tion such as calculated valve travel time and view display for status presentations and detailed
operational status, as well as a fault-­frequency displays with object presentations. The overview
report on valves and valve groups. display contains the status of the whole shutdown
system and includes links to Cause & Effect type
• Valve Leakage Test Report. detail displays and shutdown level displays.
Summarizes results from valve-leakage testing.
The Valve Leakage Test Report can be used on Every ESD field device connected to a safety controller
all valves, both critical and non-critical. The has a corresponding predefined graphic display
report consists of logging ­pressure data for a (faceplate) with real-time information and dialog
valve after the operator has created a ­pressure with the device. Interactive operator graphics can
difference across the valve. easily be customized through the use of predefined
elements and symbols.
• Automatic Shutdown Report (ASR).
Validates the success of a Process Shutdown
(PSD) or Emergency Shutdown (ESD). The ASR
— —
800xA is a registered or pending trademark We reserve all rights to this document
abb.com/highintegritysafety of ABB. All rights to other trademarks and the items and images it contains. The
reside with their respective owners reproduction, disclosure to third parties
or the use of the content of this document
We reserve the right to make technical –including parts thereof – are prohibited
changes to the products or modify the without ABB’s prior written permission.
3BSE055220 en B

contents of this document without prior


notice. With regard to purchase orders, Copyright© 2017 ABB
the agreed particulars shall prevail. All rights reserved
ABB does not assume any responsibility
for any errors or incomplete information
in this document.

You might also like