You are on page 1of 1

LEKIT C LTD

www.autodesk.com/revit

Y12@200C/C-EF Y12@200C/C-EF Y12@200C/C-EF

NOTES:
1. This drawing must be read in conjunction with all relevant
contract drawing.

Y10@200C/C-EF Y10@200C/C-EF Y10@200C/C-EF 2. The contractor must confirm all dimensions on the site before
commencing any work and any discrepancy in any of the drawings
to be adressed before implementation.

3. All dimensions are in millimeters unless specified otherwise..

4. Concrete cover to reinforcement steel to be :


(i) foundation = 50mm.
(ii)beams = 30mm.
(iii)slab, walls & staircases= 25mm
(iv) collumns =30m

5. Minimum Concrete strength for structural concrete members to


be class 25/20 and that for blinding to be class 15/40 (1:4:8). Actual
D20@150 B1&T1 D20@150 B2&T2

1000
class shall be as prescribed

6. Ribbed steel reinforcement bars to B.S.4461 are denoted "T".

7. Mild steel reinforcement bars to B.S.4449 are denoted "R".

8. All steel reinforcement must be approved by the structural


Engineer before casting.

9. Cypress timber GR.ii(cell cured & well seasoned) to be used


5600
10.Bolts to include nuts & washers.

11. This drawing remains property of the engiineer until that time all
remunerations are settled in full.

LIFT BASE 12. This drawing shall not be altered shared or coppied to a third
party not known to the engineer without a written request to the
1 1 : 25
engineer and subsequent approval by the engineer

No. Description Date

D10@200C/C

D12@200C/C

D12@200 C/C

D10@200B2/T2
D12@200B1/T1

RETAINING WALL ADAN CHAI ROAD


2 1 : 25

LIFT AND RETAINING WALL DETAILS

Project number Project Number

Date Issue Date

Drawn by KTO

Checked by FPB

15/11/2023 11:51:04
S.5

Scale 1 : 25