Weekly Report
Monday Services
Eid Holiday
(12-Aug-2019)
Adiabatic compression
Constant pressure heating
Adiabatic expansion
The gas turbine is made up of the following components:
An air compressor
A combustor
A power turbine, which produces the power to drive the air compressor and the output shaft
CX501-KB5
CX501-KB7
Power
3.9 MW
5.6 MW
Efficiency
29.10 %
32.4 %
Heat Rate
12,391 kJ/kWh
11,130 kJ/kWh
Exhaust Flow
15.8 kg/s
21.3 kg/s
Exhaust Gas Temp
555 °C
521 °C
Notes: Liquid fuel is also an option.
Steam and water injection engines are also available for enhanced power and emissions control.
PACKAGE FEATURES:
Power generation in the range of 3.9 to 5.6 MW
Aeroderivative Siemens SGT-A05 gas turbine engine (Industrial 501-K)
Compact design and high power-to-weight ratio – generator set load of only 40 tonnes
means lower foundation costs than for non-aeroderivative gas turbines
CHP, flexible and standby power applications
Can run on a wide range of fuel gases, including natural and landfill
Able to operate in extreme climates, withstanding temperatures from -60°C to +55°C
Fully integrated controls, motor control centre and batteries – allowing for a fast
installation and minimal site area
Package fully tested prior to dispatch, reducing the commissioning period and usage
of site utilities
Close-coupled generator/gearbox
Packages not bolted down
Note:
that potential difference of large GT-03 of 3.8 MW capacity is 11 KV which is needed to be
step down to meet the requirements of running electrical appliances. So, this 11 KV is
stepped down to 400 V using a transformer control system present in control room of
electricity services department, designated as GT-03 Panel room.
Centrax-GT 300:
This package is the class leader in engine power and efficiency in the 7-9 MW range of gas
turbines.
Featuring our most efficient Siemens core engine, the CX300 is highly flexible, making it an
excellent choice for an array of power generation applications.
Package Features:
((Outputs in the range of 7.9-8.5 MW and is industry-leading for engine power
and electrical efficiency in this bracket
((The package incorporates the Siemens SGT-300 core engine
((Suitable for multiple applications, including simple cycle, base load, standby
power and peak demand power plants
((Offers cogeneration option for industrial plants with high heat load and for
district heating schemes
((Low gas pressure requirements
((Factory-tested package designed for quick, cost-efficient installation and
commissioning
Note:
Small units are designed on same parameter like two that are present in electricity generation
service of Mari housing colony. Each one has 0.8 MW power capacity and 400 V potential
difference.