You are on page 1of 10

HYBRID BATTERY SYSTEM(for LITHIUM-ION BATTERY) - TERMINALS OF ECU

*1 Battery ECU assembly - -

Terminal No.
Wiring Co Input/Out
Terminal Description Condition Specified Condition
lor put
(Symbols)

z24-1 (CA2L) - Pulse generation


W-G IN/OUT CAN communication line Power switch on (IG)
z24-4 (GND) (Waveform 1)

z24-2 (CA1H) - Pulse generation


B-G IN/OUT CAN communication line Power switch on (IG)
z24-4 (GND) (Waveform 2)

z24-3 (CA1L) - Pulse generation


LG - G IN/OUT CAN communication line Power switch on (IG)
z24-4 (GND) (Waveform 2)
z24-4 (GND) -
G Ground Ground Always Below 1 Ω
Body ground
z24-8 (AM) -
Y-G IN Constant power source Always 11 to 14 V
z24-4 (GND)

z24-9 (CA2H) - Pulse generation


R-G IN/OUT CAN communication line Power switch on (IG)
z24-4 (GND) (Waveform 1)
z24-10 (GND1) -
GR Ground Ground Always Below 1 Ω
Body ground
Pulse generation
z24-12 (SI0) - Battery cooling blower Cooling fans operating
P-G OUT (Waveform 3)
z24-4 (GND) operation signal
Cooling fans not operating 4.5 to 5.5 V
Pulse generation
z24-14 (FP0) - Battery cooling blower Cooling fans operating
V-G IN (Waveform 4)
z24-4 (GND) monitor signal
Cooling fans not operating 0 Hz
z24-16 (IGCT) -
L-G IN Power source Power switch on (IG) 11 to 15.5 V
z24-4 (GND)
z25-24 (VIB) - Power source for battery
BR - L-W OUT Power switch on (IG) 4.5 to 5.5 V
z25-12 (GIB) current sensor
Terminal No. *1 Battery ECU assembly - -
Wiring Co Input/Out
Terminal Description Condition Specified Condition
lor put
(Symbols)
z25-11 (IB1) -
GR - L-W IN Battery current sensor 1 Power switch on (IG) Approximately 2.2 V
z25-12 (GIB)
z25-23 (IB0) -
V - L-W IN Battery current sensor 0 Power switch on (IG) Approximately 2.8 V
z25-12 (GIB)
Power switch on (IG)
z25-16 (TC0) -
G-G IN Intake air temperature sensor HV battery temperature: -40 to 4.75(-40°C) to 0.46 V(90°C)
z25-4 (GC0)
90°C (-40 to 194°F)
Power switch on (IG)
z25-22 (TB0) -
P-P IN Battery temperature sensor 0 4.75(-40°C) to 0.46 V(90°C)
z25-10 (GB0) HV battery temperature: -40 to
90°C (-40 to 194°F)
Power switch on (IG)
z25-21 (TB1) -
Y-Y IN Battery temperature sensor 1 HV battery temperature: -40 to 4.75(-40°C) to 0.46 V(90°C)
z25-9 (GB1)
90°C (-40 to 194°F)
Power switch on (IG)
z25-20 (TB2) -
L-L IN Battery temperature sensor 2 HV battery temperature: -40 to 4.75(-40°C) to 0.46 V(90°C)
z25-8 (GB2)
90°C (-40 to 194°F)
Power switch on (IG)
z25-19 (TB3) -
R - P-B IN Battery temperature sensor 3 HV battery temperature: -40 to 4.75(-40°C) to 0.46 V(90°C)
z25-7 (GB3)
90°C (-40 to 194°F)
Power switch on (IG)
z25-18 (TB4) -
W - W-G IN Battery temperature sensor 4 4.75(-40°C) to 0.46 V(90°C)
z25-6 (GB4) HV battery temperature: -40 to
90°C (-40 to 194°F)
Power switch on (IG)
z25-17 (TB5) -
B - B-W IN Battery temperature sensor 5 HV battery temperature: -40 to 4.75(-40°C) to 0.46 V(90°C)
z25-5 (GB5)
90°C (-40 to 194°F)
Terminal No. Wiring Co Input/Out
Terminal Description Condition Specified Condition
(Symbols) lor put

z22-16 (GA0) -
B - P-B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-11 (VA1)
z22-11 (VA1) -
P-B - L-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-6 (VA2)
z22-6 (VA2) -
L-W - LG IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-1 (VA3)
z22-1(VA3) -
LG - B-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-17 (VA4)
z22-17 (VA4) -
B-W - Y IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-12 (VA5)
z22-12 (VA5) -
Y-G IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-7 (VA6)
z22-7 (VA6) -
G - GR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-2 (VA7)
z22-2 (VA7) -
GR - V IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-18 (VA8)
z22-18 (VA8) -
V-R IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-13 (VA9)
z22-13 (VA9) -
R-L IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-8 (VA10)
z22-8 (VA10) -
L-P IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-3 (VA11)
z22-3 (VA11) -
P - BR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-19 (VA12)
z22-19 (VA12) -
BR - W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-14 (VA13)
z22-14 (VA13) -
W-B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-9 (VA14)
z22-9 (VA14) -
B - W-G IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-4 (VA15)
Terminal No. Wiring Co Input/Out
Terminal Description Condition Specified Condition
(Symbols) lor put

z22-4 (VA15) -
W-G - L-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-20 (VA16)
z22-20 (VA16) -
L-W - P-B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-15 (VA17)
z22-15 (VA17) -
P-B - B-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-10 (VA18)
z22-10 (VA18) -
B-W - LG IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z22-5 (VA19)
z23-13 (GA1) -
Y-G IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z23-9 (VA20)
z23-9 (VA20) -
G - GR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z23-5 (VA21)
z23-5 (VA21) -
GR - V IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z23-14 (VA22)
z23-14 (VA22) -
V-R IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z23-10 (VA23)
z23-10 (VA23) -
R-L IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z23-15 (VA24)
z23-15 (VA24) -
L-P IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z23-11 (VA25)
z23-11 (VA25) -
P - BR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z23-16 (VA26)
z23-16 (VA26) -
BR - W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z23-12 (VA27)
z23-12 (VA27) -
W-B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z23-8 (VA28)
z18-5 (VAD) -
B-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z18-9 (VA29)
z18-9 (VA29) -
W - BR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z18-13 (VA30)
Terminal No. Wiring Co Input/Out
Terminal Description Condition Specified Condition
(Symbols) lor put

z18-13 (VA30) -
BR - P IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z18-10 (VA31)
z18-10 (VA31) -
P-L IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z18-14 (VA32)
z18-14 (VA32) -
L-R IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z18-11 (VA33)
z18-11 (VA33) -
R-V IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z18-15 (VA34)
z18-15 (VA34) -
V - GR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z18-8 (VA35)
z18-8 (VA35) -
GR - G IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z18-12 (VA36)
z18-12 (VA36) -
G-Y IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z18-16 (VA37)
z19-1 (GA2) -
LG - B-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-6 (VA38)
z19-6 (VA38) -
B-W - P-B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-11 (VA39)
z19-11 (VA39) -
P-B - L-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-16 (VA40)
z19-16 (VA40) -
L-W - W-G IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-2 (VA41)
z19-2 (VA41) -
W-G - B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-7 (VA42)
z19-7 (VA42) -
B -W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-12 (VA43)
z19-12 (VA43) -
W - BR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-17 (VA44)
z19-17 (VA44) -
BR - P IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-3 (VA45)
Terminal No. Wiring Co Input/Out
Terminal Description Condition Specified Condition
(Symbols) lor put

z19-3 (VA45) -
P-L IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-8 (VA46)
z19-8 (VA46) -
L-R IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-13 (VA47)
z19-13 (VA47) -
R-V IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-18 (VA48)
z19-18 (VA48) -
V -GR IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-4 (VA49)
z19-4 (VA49) -
GR - G IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-9 (VA50)
z19-9 (VA50) -
G-Y IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-14 (VA51)
z19-14 (VA51) -
Y - B-W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-19 (VA52)
z19-19 (VA52) -
B-W - LG IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-5 (VA53)
z19-5 (VA53) -
LG - L - W IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-10 (VA54)
z19-10 (VA54) -
L-W - P-B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-15 (VA55)
z19-15 (VA55) -
P-B - B IN Hybrid Battery Cell Voltage Always 1.9 to 4.1 V
z19-20 (VA56)

1. Oscilloscope waveforms

Tip:

Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.

a. Waveform 1 (CAN communication line)


Item Content
Item Content
CH1: z24-9 (CA2H) - z24-4 (GND)
Terminal
CH2: z24-1 (CA2L) - z24-4 (GND)
Equipment Setting 1 V/DIV., 50 μs/DIV.
Condition Power switch on (IG)

Tip:

The waveform will vary depending on the content of the digital communication
(digital signal).
b. Waveform 2 (CAN communication line)
Item Content
CH1: z24-2 (CA1H) - z24-4 (GND)
Terminal
CH2: z24-3 (CA1L) - z24-4 (GND)
Equipment Setting 1 V/DIV., 50 μs/DIV.
Condition Power switch on (IG)

Tip:

The waveform will vary depending on the content of the digital communication (digital signal).

c. Waveform 3 (Battery cooling blower operation signal)


Item Content
Terminal z24-12 (SI0) - z24-4 (GND)
Equipment Setting 10 V/DIV., 1 ms/DIV.
Battery cooling blower assembly
Condition operating (Active Test of cooling
fan being performed)

Tip:

The wavelength will vary with the operating speed of the battery cooling blower assembly.
d. Waveform 4 (Battery cooling blower monitor signal)
Item Content
Terminal z24-14 (FP0) - z24-4 (GND)
Equipment Setting 2 V/DIV., 2 ms/DIV.
Battery cooling blower assembly
Condition operating (Active Test of cooling
fan being performed)

Tip:

The wavelength will vary with the operating speed of the battery cooling blower assembly.

You might also like