Rotary Lobe Compressor
5% 5%
n Optimized uidic
fl designofof inlet
andanddischarge reduces 80
n Optimized fluidic design inlet discharge reduces 30%
Peak Demand kW
required air ow
fl evenwithout the use ofa
quired air flow even without the use of a VFDVFD 50
40
n
n
Highperformancebeltdrivesystemwithlossesunder3% Existing Rotary
30 PD Blower Lobe Screw
n Highefficiencymeanslowerdischargetemperature. Compressor
20
This reduces aging of downstream membranes or
diffusers in synthetic materials. 10
0
n Optimalairow fl withintheacousticenclosurebrings
cool air directly to the intake side and increases
compression efficiency
Pressure
Inlet Filter/Silencer Safety Valve
Easily replaceable filter Spring-loaded.
element is downstream of Specifically designed
the silencer for cleanliness. for low pressure
applications. Mounted
vertically downstream
of the silencer
for longevity.*
(hidden in photo)
Instrumentation
Standard filter Aeromat Start
maintenance indicator Unloading Valve
and p2 gauge (Optional)
Allows startup of the
main motor with no load.
The valve is completely
self activating and does
not need any auxiliary
Belt Guard electrical or pneumatic
Designed for easy power source.
access to the drive.
OSHA standard. Discharge Manifold*
With integral full bore check
valve for low pressure drop.
The check valve can be
inspected without
disconnecting the piping.
Non-chatter check valve suitable
for adjustable speed operation.
NEMA F3
Premium Efficiency
TEFC Motor
Reactive Discharge Silencer Discharge
Machined support surface Flexible Connector
Hinged Motor Plate for blower. Stiff for installation Reinforced rubber.
Steady alignment and on vibration isolating mounts. Downstream of
consistent tension Vibration Isolating Mounts Low pressure drop design. discharge silencer to
provided by the motor Rubber-type. Located No absorption packing material. reduce transmission of
weight. No springs under the supporting ATEX spark arrestor. structure-borne noise.
needed. Constant base. No special
high efficiency. foundation required.
Instrumentation package:
AERtronic Control System includes
pressure transmitters for intake,
discharge and oil pressure, as well
as resistance temperature detectors
(RTD) discharge and oil temperature
and operator interface.
*PED compliant pressure vessel
Driving Processes Economically.
From Our Installation to Your Satisfaction.
n
n The up
The up to
to 4:1
4:1 turndown
turndown adaptibility
adaptibility of
of the
theDelta
DeltaHybrid
Hybrid
n
n New pulsation reduction
reductionin
inthe
thecompressor
compressorstage
stage enables plants to operate efficiently at minimum
enables plants to operate efficiently at minimum
n
n Silencer without absorption
absorptionmaterials
materials(patented)
(patented) capacity without blowing
blowing off
off excess
excess air
air
n
n Additional insulation
exterior mount insulation for the H machines
n
n Extended process
Extended process turndown
turndown with
with aa minimum
minimum number
number
of machines
n
n Inlet cone to further
further reduce
reduce inlet
inletnoise
noise(patented)
(patented)
n
n Optimized acoustic
acoustic enclosure
enclosure
Aertronic. Intelligent Control for Fast Processes.
Aertronic. Intelligent Control for Fast Processes.
Scope of supply
Scope
Newlyof
n supply
designed Rotary Lobe Compressor
n Newly designedsilencer
n Discharge Rotary integrated
Lobe Compressor
in base frame
n Discharge silencer
n Combined integrated
filter in base frame
and silencer
n Combined filterefficiency
n Premium and silencer
electric motor
n Premium efficiency electric
n High-performance beltmotor
drive
n High-performance
n Hinged motorbelt
platedrive
n Hinged motor plate
n Connecting housing with check valve
n Connecting housing
n Pressure safetywith
valvecheck valve
n Pressure safety
n Flexible valve
pipe connector with clamps/or flanged
Aerzen AERtronic Controller
n expansion
Flexible joint with clamps/or flanged
pipe connector The Aerzen AERtronic controller is based on a modular design
expansion joint Aerzen controller AERtronic
approach and offers a solution tailored to each individual
Accessories basenew
The Aerzen controller AERtronic
application. The controller includes an intuitive touchscreen,
module
Aerzenas well ascontroller
AERtronic application-dependent
is based on a modular add-on
Accessories
n Acoustic enclosure for indoor or for outdoor installation
modules.
design
The new
the
All
approach
Aerzen
parameters
individual
measured
AERtronic
are
application.
operational
and controller
offers
adjustable
The
a issolution
with
controller
baseddata
the
on isa modular
retrievable
tailored
user-friendly
includes an
to each and
menu
intuitive
design approach and offers a solution tailored to each
n Acoustic enclosure
n Cooling for indoor
fan: shaft or for
or electric outdoor
motor installation
driven structure.
touch
individual screen, theThe
application. base moduleincludes
controller as wellanasintuitive application
Cooling fan:unloading
shaft or electric touch dependent
Thescreen,
base add-on
the
unit base
used modules.
module
across the All
as measured
well
Aerzen as
product operating
application
range data
includes
valve motor driven
n
n Start
is
dependent retrievable
the following and parameters
features: All
add-on modules. adjustable
processor
measured unit, in a
inlet and
operating user-friendly
discharge
data
n Start unloading
n Aerzen valve AERtronic or gauges
controller menu
pressure,
is retrievable structure.
and andThe
oilparameters base
discharge unit usedin aacross
temperature,
adjustable the Aerzen
motor
user-friendly thermal
n Aerzen controller AERtronic or gauges protection,
menuproduct range
structure. three free digital
Theincludes
base inputs,
the used
unit following a features:
across relay
theoutput, and bus
processor
Aerzen
communication
unit,
product oil level
range includes interface
control,theinlet with
and control
following discharge
features: panel and expansion
pressure,
processor motor
Modifications and upgrades modules.
unit, oil level control, inlet and discharge pressure, motor relay
temperature and speed, three free digital inputs, a
Modifications and upgrades
n ATEX certification
output,
temperature
The basic and
and bus communication
speed,
system three free
provides interface
digital inputs,
maintenance with
alertscontrol
a relay panel
for air filter
and expansion
bus modules.
element, motor lubrication, v-belt service, blower oil, and
output, and communication interface with control panel
n ATEX certification
n ASME, GOST, China License certification
basic system
and expansion inspection. The expansion module offers three
modules.
n ASME, GOST, China License
n All-in-one-solution withcertification
integrated starter panel The
digitalexpansion
inputs and module offers
three relaythree
outputs digital as inputs
well asand threefor
inputs
The relay
expansionoutputs as
module well as
offers inputs
three for temperature
digital inputs
additional analog inputs (for example oil pressure, enclosure andand pressure
three
n All-in-one-solution
n Separate control with integrated starter panel
panel
relay measurements
outputs as well
temperature, (for
as example,
inputs
vibration, oil temperature,
for temperature
blower speed). compressor
and pressure
n Separate controlinverter
n Frequency panel (VFD) outlet temperature,
measurements (for example,oil pressure). Additional
oil temperature, digital inputs,
compressor
The unit can also be configured as a local operator for a VFD
n Frequency inverter (VFD)
n Other accessories on request outletrelay outputs,
temperature, Pt
oil 1000 and
pressure). analogue
Additional inputs
digital and outputs
inputs,
or motor starter as well as provide data communication for
relay remote
outputs, for
Pt 1000 and pressure or
analogue temperature
inputsetc.).and outputs with
control
n Other accessories on request observation (Modbus, Ethernet,
use of a or
for pressure VFD, as well as control
temperature bus interfacewith for
use of communication
a VFD, as wellwith as busa master
interface controller
for or
other systems and for
communication with a master controller or data communication
othercan be provided
systems and forwith data additional
communication application-
can be related expansion
provided and special
with additional modules.
application-
related expansion and special modules.
Delta Hybrid
Delta Hybrid Performance
Performance Data
Data
Positive Pressure
Positive Pressure
Positive Pressure Noise Pressure
Aerzen Differential Pressure Volume Flow Motor Power Noise Pressure
Level*
Hybrid Model
Aerzen (max mbar) Pressure
Differential (max psi) (max mVolume
3
/h) Flow
(max cfm) (max kW) (max HP)
Motor Power Noise Pressure
Level*
(max dB (A))
Aerzen
Hybrid Model (maxDifferential
mbar) Pressure
(max psi) (max mVolume
3
/h) Flow
(max cfm) Motor Power
(max kW) (max HP) Level*
(max dB (A))
D 12 Model
Hybrid H 1500
(max mbar) 22 psi)
(max (max670
m /h)
3
390
(max cfm) (max37kW) 50 HP)
(max (max73dB (A))
D 12 H 1500 22 670 390 37 50 73
DD1212 HS 1000
1500 15
22 690
670 410
390 30
37 40
50 72
73
D 12 S 1000 15 690 410 30 40 72
DD1217 SL 800
1000 12
15 810
690 480
410 30 40
40 66
72
D 17 L 800 12 810 480 30 40 66
DD17
24LH 1500
800 22
12 1370
810 810
480 75
30 100
40 76
66
D 24 H 1500 22 1370 810 75 100 76
DD2424 HS 1500
1000 22
15 1370
1390 810
820 75
55 100
75 76
74
D 24 S 1000 15 1390 820 55 75 74
DD2428S 1000 15 1390 820 55 75 74
D 28 LL 800
800 12
12 1340
1340 790
790 45
45 60
60 70
70
DD28
36LHH 800
1500 12
22 1340
1900 790
1118 45
110 60
150 70
76
D 36 1500 22 2100 1240 110 150 76
DD36 H
36SS 1500
1000 22
15 2100
2150 1240
1270 110
75 150
100 76
76
D 36 1000 15 2150 1270 75 100 76
D 36 S 1000 15 2150 1270 75 100 76
DD46
46LL 800
800 12
12 2350
2350 1380
1380 75 100
100 70
70
D 46 L 800 12 2350 1380 75 100 70
DD6252HS 1000
1500 15
22 3120
3400 1836
2000 110
160 150
200 77
81
D 62 H 1500 22 3400 2000 160 200 81
DD62
62 HS 1000
1500 15
22 3500
3400 2060
2000 110
160 150
200 79
81
D 62 S 1000 15 3500 2060 110 150 79
DD75 L
62 S 800
1000 12
15 3870
3500 2280
2060 132
110 200
150 79
79
D 75 L 800 12 3870 2280 132 200 79
DD98 H
75 L 1500
800 22
12 5600
3870 3280
2280 250
132 350
200 81
77
D 98 H 1500 22 5600 3280 250 350 81
DD98
98SHS 1000
1500 15
22 5800
5600 3390
3280 200
250 200
350 79
81
D 98 1000 15 5800 3390 200 200 79
D 152 S 1000 15 8900 5240 315 400 88
DD152
98 SS 1000
1000 15
15 5800
8900 3390
5240 200
315 250
400 79
88
* Machine emitted noise with acoustic enclosure and with connected and insulated piping, tolerances ± 2 dB(A)
D152 H 1500emitted noise22with acoustic8700
* Machine 5120connected and
enclosure and with 400insulated piping,
536 tolerances ±812 dB(A)
D 152 S 1000 15 8900 5240 315 400 80
* Machine emitted noise with acoustic enclosure and with connected and insulated piping, tolerances ± 2 dB(A)
Vacuum
Vacuum
Vacuum Noise Pressure
Aerzen Differential Pressure Volume Flow Motor Power NoiseLevel*
Pressure
Noise Pressure
Aerzen
Aerzen
Hybrid Model Differential
(max mbar) Pressure
Differential Pressure
(in. Hg) (max mVolume
3
/h) Flow
Volume (icfm) (maxMotor
MotorPower
kW) Power(HP) Level*
(max dB (A))
Level*
Hybrid
HybridModel
Model (max mbar) (max psi)
(in. Hg) (max m m33/h)
/h) (max cfm)
(icfm) (max
(maxkW)
kW) (max HP)
(HP) (max dB (A))
D 12 E -700 -21 650 380 18.5 25 (max 72
dB (A))
D 12 E -700 -21 650 380 18.5 25 72
DD2412 EE -700
-700 -21
-21 650
1320 380
780 18.5
37 25
50 72
73
D 24 E -700 -21 1320 780 37 50 73
DD36
24EE -700
-700 -21
-21 1320
2000 780
1180 37
55 5075 73
76
D 36 E -700 -21 2000 1180 55 75 76
DD62
36EE -700
-700 -21
-21 3300
2000 1940
1180 90
55 125
75 79
76
D 62 E -700 -21 3300 1940 90 125 79
DD98
62EE -700
-700 -21
-21 5400
3300 3180
1940 132
90 175
125 78
79
D 98 E -700 -21 5400 3180 132 175 78
DD152
98 EE -700
-700 -21
-21 8500
5500 5000
3237 160
132 210
175 79
78
D 152 E -700 -21 8500 5000 160 210 79
D 152 E * Machine
-700 emitted noise with
-21 acoustic enclosure
8500 and with
5000 connected and
160 insulated piping,
210 tolerances ±
792 dB(A)
* Machine emitted noise with acoustic enclosure and with connected and insulated piping, tolerances ± 2 dB(A)
* Machine emitted noise with acoustic enclosure and with connected and insulated piping, tolerances ± 2 dB(A)
Nomenclature:
Nomenclature:
Example:
Example: Style:
D 62 S
D 62 S Style:
H = high differential pressures to 1500 mbar (22 psi)
H = high differential pressures to 1500 mbar (22 psi)
S = short, differential pressures to 1000 mbar (15 psi)
S = short, differential pressures to 1000 mbar (15 psi)
L = long, differential pressures to 800 mbar (12 psi)
L = long, differential pressures to 800 mbar (12 psi)
E = Vacuum (exhauster) design to 700mbar (-21“ Hg)
E = Vacuum (exhauster) design to 700mbar (-21“ Hg)
Max. Volume flow in m³/min (approx.)
Max. Volume flow in m³/min (approx.)
Rotary Lobe Compressor
Rotary Lobe Compressor
W D
Aerzen means trouble-free compression.
Aerzen’s modular blower packages have been offered since the 1960s. H
Aerzen Delta Blower packages have been in successful operation since H
the 1990s. They are just one of the offerings in our single stage positive
displacement program. Whatever Aerzen
your application andLEED
USA is a certified installation
Gold, Green facility.
H
Aerzen
requirements, be sure to consider Aerzen.USA is a certified LEED Gold, Green facility.