You are on page 1of 1

Development Plan Remarks Remark

DP Location Plan Zone - Residential


PROPOSED SITE

0.900
Road widening - YES (MR-28 & SMR -24)
SMR 24 - The 12.0 m. Road Widening of 12.0 m.
between Shivaji Chowk to Tanaji Chowk is proposed
to be retained with equal Widening on both sides of
the Road.
EPR 19- The 12.0 m. Road Widening of 12.0 m.

3.150
between Shivaji Chowk to Tanaji Chowk is proposed
to be retained with equal Widening on both sides of

2.100
the Road.
SM Remarks Dated 15/09/2022
N
EP Remarks Dated 15/09/2022
Court orders if any - No
STAMP OF APPROVAL OF PLAN

3.150
Google Location Plan
AREA STATEMENT
1. Area of plot
(Minimum area of a,b,c, to be considered)
PROPOSED SITE (a) As per ownership document (7/12 , CTS extract) 244.70

3.500
(b) As per measurement sheet 81.54
(c) As per site 81.54
0.375

2. Deduction for
(a) Proposed D.P./D.P Road widening Area/Service -
Road/Highway widening
ELEVATION SECTION X-X (b) Any D.P./D.P Reservation area NILL
X X X X (c) (Total a+b) NILL
3.600 CTS.NO
3228
3.600 3.600 3.600
3. Balance area of plot(1-2) 81.54
TOILET TOILET
3.600

1.200

1.200
1.20 x 1.20
D2
TOILET
2.10 x 1.20
V1
2.10 x 1.20 V1 4. Amenity Space (if applicable) N.A
SEPTIC TANK
D2
D2
1.200 1.200 (a) Required- N.A
A) AREA OF BLOCK "A"
= 61.62 SQM (b) Adjustment of 2(b), if any - N.A

7.770
BEDROOM
3.30 x 2.70
BEDROOM
3.30 x 2.70 C (c) Balance Proposed - N.A
OPEN TERRACE B) AREA OF BLOCK "B" = 78.30 SQM 5. Net Plot area (3-4(c) 81.54
DEDUCTION = 1.77 SQM

0.500

0.500
D1 0.900 0.900 6. Recreational Open space (if applicable) N.A

15.250
D1

D1 A TOTAL AREA (a) Required- N.A


PROPOSED
BUILDING OF BLOCK B = 76.53 SQM
KITCHEN CTS.NO
CTS. NO.-3229 CTS.NO (b) Proposed - N.A

22.65
3.30 x 3.70 3227 3230
BEDROOM

21.650

21.650
2.60 x 3.40 7. Internal Road area N.A
W1 W1 W1
B C) AREA OF BLOCK "C" = 28.00SQM
DEDUCTION = 1.77 SQM 8. Plotable area (if applicable) N.A
UP TOTAL AREA 9. Built up area with reference to Basic F.S.i. as per
OF BLOCK C = 26.23 SQM front road width
1.5
(Sr.No. 5xbasic FSI)
HALL
3.3 X 14.25 2.550 10. Addition of FSI on payment of premium N.A
TOTAL AREA (A+B+C) = 164.38 SQM
21.750

DN 11. In - situ F.S.I./TDR loading N.A

6.400
D1
RAIN WATER
HARVESTING

(a). In - situarea against D.P. road [2.0xSr.No.2(a)] N.A


1.000

N
if any
12M WIDE ROAD
HALL
(b) in-situ area against Amenity Space if handed
3.30 x 3.60 over [2.00 or 1.85xSr.No4(b)and/or(c) ]. N.A
SITE PLAN SCALE - 1:200 1.00
(c) TDR area N.A
W1 (d) Total in-situ/TDR loading proposed N.A
LEGENDS
D1
BLOCK AREA CALCULATION 12. Additional FSI area under Chapter No.7 N.A
PLOT BOUNDARY SHOWN- 13. Total entitlement of F.S.I in the proposal.
BUILT UP PROPOSED - (a) (9+10(b)+11(b) or 12whiehever is applicable.
OPEN TERRACE OPEN TERRACE 1.5
DRAIN LINE -
WATER LINE - (b) Ancillary Area F.S.I upto 60% or 80% with
PARKING 42.04
payment of charges.
2.40 X 6.60 SCHEDULE OF DOORS & WINDOWS
BALCONY RAIN WATER ON
(c) Total entitlement (a+b) 1.5
ROOF TOP 1.200

2.40 X 6.60 VENTPIPIE CHAMBER


CHAMBER
OUTLET
TYPE SIZE DISCRIPTION 14. Maximum utilization limit of F.S.I (building potential)
FILTER BED
WELL
INLET
1.200

BORE Permissible as per road width(as per Regulation No.6.1 or 2.1


100 mm PIPE FOR
CARRING RAIN WATER PLAN
D1 0.90 X 2.10 T.W.PANELED DOOR 6.2 or 6.3 or 6.4 as applicable )x1.6or1.8
WITH MESH AT ROOF PLAN

0.75 X 2.10
15. Total built-up Area in proposal.(excluding area at
UP 1 M. ABOVE
RAIN WATER FALLING ON
ROOF/GROUND COLLECTED BORE
SECTION D2 T.W.PANELED DOOR 164.38
1.0 m X1.0 m
G.L.
FROM ALL SIDE
PERFORATED
COVER
Sr,No.17b)
6 M.& ABOVE G.L.

UPTO 10 % DEPTH.
FINE SAND UPTO 10 % DEPTH.
2 TO 2.5 m

UPTO 20 % DEPTH.
FINE SAND

W1 1.50 X 1.20 ALU. SLIDING WINDOW (a) Existing Built-up Area. N.A
3.00 M

COARSE SAND UPTO 20 % DEPTH.


UPTO 20 % DEPTH. COARSE SAND
20 MM STONE UPTO 20 % DEPTH.
OPEN WELL 20 MM STONE
X X UPTO 50 % DEPTH.
X X 40 MM STONE

DETAILED FILTER BED


UPTO 50 % DEPTH.
40 MM STONE
1.00 M
W2 1.20 X 1.20 ALU. SLIDING WINDOW (b) Proposed Built-up Area (as per 'P-line') N.A
SECOND FLOOR PLAN
GROUND FLOOR PLAN FIRST FLOOR PLAN TERRACE FLOOR PLAN PLAN (c) Total (a+b) 164.38
SEPTIC TANK V1 0.60 X 0.75 ALU. SLIDING WINDOW
16. F.S.I Consumed (15/13) (should not be more than
2.01
seial No.14 above.)
Owner's Declaration- 17. Area for Inclusive Housing if any N.A
TITLE
I/We undersigned hereby confirm that I/We would abide by plans approved by Authority collector (a) Required (20%of Sr.No.5) N.A
I/We would execute the structure as per approved plans. Also I/We would execute the work
(b) Proposed N.A
PROPOSED CONSTRUCTION OF RESIDENTIAL BUILDING REVISION under supervision of proper technical person so as ensure the quality and safety at the work site.
UNDER PMAY ON CITY SURVEY NO-3229
AT- ISLAMPUR, TAL-WALWA,DIS.- SANGLI
OWNER SIGNATURE
Certificate of Area -
OWNER NAME Certified that the plot under reference was surveyed by me on________________and the dimensions of
sides etc. of plot stated on plan are as measured on site and the area so worked out tallies with the area Er. VISHAL S. KAMBLE
Mrs. PUTLABAI RAJARAM PATIL stated in document of Ownership/ T.P. Scheme Records/ Land Records Department/City Survey records. Name ,Signature & Seal of ENGINEER

You might also like