You are on page 1of 1

EXISTING SLAB JOINT

RIBBED BARS 16mm DIA. x 700mm AT


275mm CENTRES POST-INSTALLED
INTO EXISTING SLAB HIGH-STRENGTH (MIN. 40 N/mm2)
EXISTING SLAB JOINT NON SHRINK GROUT

RIBBED BARS 16mm DIA. x 700mm AT 1000mm LONG X 50mm WIDE X 75mm
275mm CENTRES POST-INSTALLED EXISTING SLAB DEEP POCKET AT 275mm CENTRES TO
275mm

INTO EXISTING SLAB INSTALL TO POST GROUT RIBBED BARS

1000mm LONG X 50mm WIDE X 75mm


275mm

DEEP POCKET AT 275mm CENTRES TO

75mm
INSTALL TO POST GROUT RIBBED BARS
A
-

HIGH-STRENGTH (MIN. 40 N/mm2)


NON SHRINK GROUT
1000mm

1 EXISTING SLAB JOINT - PLAN A SECTION


- -

INFILL RC SLAB (TO FULL H10 BARS AT 200mm C/C IN BOTH DIRECTION.
DEPTH OF TRENCH) WITH H10 BARS TO BE POST-INSTALLED WITH HILTI
BARS AT 200mm C/C IN BOTH HY-200A RESIN WITH MINIMUM 150mm
DIRECTIONS AND 40mm COVER EMBEDMENT INTO EXISTING TRENCH WALLS EXISTING DOOR RUNNER TO BE
INFILLED WITH HIGH STRENGTH
NON-SHRINK GROUT
MIN. 150mm

450mm TYP.

The Hub
500 Park Avenue
Aztec West
MIN. 150mm

Bristol
EXISTING TRENCH BS32 4RZ

Tel: +44 1454 662000


ALL SURFACES TO BE www.atkinsrealis.com
SCABBLED AND CLEANED
PRIOR TO POURING NEW SLAB 470mm TYP.

Title GKN Aerospace Building 05A

Slab Remedial Details


Doc. ref. 5159911-SK01
2 EXISTING TRENCH INFILL DETAIL 3 EXISTING DOOR RUNNER MAKING GOOD DETAIL Rev. P01 By YW Date 27/02/2024
- -
Job GKN Aerospace
Job No. 5159911

You might also like