1 Which is used to connect A) Switch B) Power C)Under D)None A) Switch board


switching equipment to board cables Ground cables cables
MDF cables

2 Which is used to connect A) Switch B) Power C)Under D)None C)Under


outdoor equipment to board cables Ground cables Ground cables
MDF cables

3 Which is used to connect A) Drop wire B) Jumper C)Under D)None B) Jumper wire
indoor switch board wire Ground cables
cables to outdoor cables
in MDF

4 Which is used for the A) Drop wire B) Jumper C)Under D)None A) Drop wire
connection from DP to wire Ground cables
customer premisses

5 Which cables are used A) Primary B) Distribution C)PCM D)None A) Primary


for the connection from
MDF to Pillar

6 Which cables are used A) Primary B) Distribution C)PCM D)None B) Distribution


for the connection from
Pillar to DP

7 Which cables are also A) Primary B) Distribution C)PCM D)None C)PCM


known as Junction
cables

8 MDF stands for --------- A) Main B) Media Drop C)Media drop D)None A) Main
distribution Frame furniture distribution
Frame Frame

9 Switch board cables are A)copper & B) Copper & C)Aluminium & D)None A)copper &
fabricated with 99.97% PVC rubber PVC PVC
pure solid electrolyte
grade--------and in house
developed ----------------
insulation

10 Which is used for A) Drop wire B) Jumper C)Under D)None B) Jumper wire
connecting cable wire Ground cables
termination to exchange
equipment in MDF

11 Which type of under A) PIJF B) FIJP C)IJFE D)None A) PIJF


ground cables are used
in BSNL for providing
telephone connection

12 under ground cables A) copper B) Zink C)Lead D)None A) copper


used in BSNL are
having the conductor
made of

13 The Pairs in under A) Colour B) Pair Size C)Pair Count D)None A) Colour code
ground cables are code
identified by

14 The Pairs in under A) 20, 50, B) 25, 60 , 120 C)15, 135 , 150 D)None A) 20, 50, 100,
ground cables are 100, 200 Pairs , 250 pairs 200 pairs
pairs

15 Each Jumper wire in A) Sealed B) Individual C) Twisted Pair D)None C) Twisted Pair
MDF is made of pair

16 Which is the media A) MDF B) DDF C) IDF D)None A) MDF


between switching
network and subscriber
lines

17 MDF usually holds A)Protective B) Battery C) Current D)None A)Protective


central office ---------- devices devices

18 A cable connected for Distribution Secondary Primary cable switch switch board
internal equipment in cable cable board cable cable
exchanges i

19 Capacity of swicth board 8 pr , 16 pr , 10pr 20 pr, 50 Both none 8 pr , 16 pr , 64


cables are 64 pr pr pr

20 The switch board cables 64 pr tag 100 pr tag 200 pr tag none 64 pr tag
terminated in blocks blocks blocks blocks

21 The tools required for G-Clamp Lacing Twine Runway all all
stitching switch board
cables are

22 The tool used for Krown tool Blow lamp Crimping tool none Krown tool
termination of switch
board cables at MDF is

23 The tool used for Krown tool Blow lamp Crimping tool none Crimping tool
termination of switch
board cables at exchange
side is

24 The mostly used U.G PIJF PJIF IJPF None PIJF


cables in BSNL

25 The cables used for Long Junction Cable Local cable none Local cable
local subscriber network distance
is called cable

26 The cables used to link Long Junction Cable Local cable none Junction Cable
two exchanges are distance
known as cable

27 The cables used to Long Junction Cable Local cable none Long distance
connect two major towns distance cable
is known as cable

28 PCM Cables are Long Junction Cable Local cable none Junction Cable
examples of distance
cable
29 Coaxial cables are Optical Fiber Under ground Junction Cables None Optical Fiber
replaced by --cables for cables cables cables
better performance

30 The cables erected as Switch board Aerial cables Junction cables none Aerial cables
over head cables are cables

31 The planning period of 20 years 7-10 years 5 years none 7-10 years
Primary cables is

32 The planning period for 20 years 7-10 years 5 years none 20 years
distribution cables is

33 The petroleum jelly used Provide To prevent To prevent None To prevent


in PIJF cable is for strength to rodents from moisture from moisture from
the cable damaging the damaging damaging
cable insulation insulation

34 Pillar contains CT boxes DP boxes Splitters none CT boxes

35 DP points are installed wall mounted Pole mounted Both none both
as

36 which is used to provide Switch board Distribution Drop wire Primary Drop wire
connection between cables cables cable
subscriber premisses to
DP

37 In BSNL ---cables are Silver Aluminium Copper iron copper


mostly used for out door
plant

38 The exchange cables IDF DDF MDF FDF MDF


and UG cables meet at

39 Protection devices like exchange Line Side IDF DSLAM Line Side
IPM are equipped on the side
-----side of MDF

40 GD tube stands for Gas Gas damage Gas distribution none Gas Discharge
Discharge tube tube tube
tube

41 The tool used for Insertion tool Crimping tool Nipper None Insertion tool
connecting wire to IDC (
insulation displacement
contact ) type connection

42 Tool used for jointing Insertion tool Crimping tool Nipper None Crimping tool
PIJF cables with U-Y
connectors is

43 No of UY connectors 50 100 200 400 100


required for 50 pair joint

44 which is used to connect IDF MDF DDF FDF MDF


the exchange equipment
to external lines

45 UG cables on terminated 64 pr tag 100 pr tag 200 pr tag none 100 pr tag
on -pair tag blocks blocks blocks blocks blocks

46 Protective device used at LJU Rosette box both none Both


subs premisses to protect
subs equipment from high
voltage is

47 A MDF vertical Tag block tag number vertical column none vertical column
representation 001-04-96 number
the digits 001 denotes

48 The counting of vertical Right to left left to right top to bottom bottom to Right to left
columns in MDF is from top

49 A MDF vertical Tag block tag number vertical column none Tag block
representation 001-04-96 number number
the digits 04 denotes

50 A MDF vertical Tag block tag number vertical column none tag number
representation 001-04-96 number
the digits 96 denotes

51 In MDF the cables underground switchboard junction cables distribution switchboard


terminated from echange cables cables cables cables
equipment are

52 The end point of Pillar Cabinet DP LJU DP


underground cable is

53 100 pair cable contains -- 10 5 100 50 5


----number of 20 pair
units

54 TSF-3 kit is used for 20pair 50 pair 100 pair 800 pair 100 pair
jointing --pair cables

55 No of UY connectors 50 100 200 400 100


required for jointing 50
pair cable

56 The existing underground PCUT PIJF PTJF PCQT PIJF


cables in BSNL are

57 The coaxial cables are Optical fiber PCM cables Distribution Primary Optical fiber
replaced by -- cables for cables Cables cables cables
long distance working

58 Which statements are planning planning planning period all of the all of the
true period for period for for Distribution above above
primary Secondary cable is 20
cable is 5 cable is 10 years with over
years with years with provisioning
over over factor of 1.3
provisioning provisioning
factor of 1.1 factor of 1.2

59 The distribution cable less more very less cannot say more
laid should be --- than
the primary cable

60 The color code of 81st blue white orange white green white yellow white blue white
pair in 100 pair cable

61 The -----are used in trench CT boxes DP boxes MDF CT boxes


Pillars for termination of
under ground cables
62 The cables run from primary distribution junction cable can not say distribution
pillar to Distribution point cable cable cable
is

63 The cable runs between primary Secondary Distribution none Secondary


cabinet and pillar is cable cable Cables cable
known as

64 Inner Zone is identified 00 01 to 2o 21 to 99 none 00


by

65 The max distance in 2 km 1 km 500 m none 500 m


case of innerzone is

66 300 pair cable is which paper pijf Pcm coaxial paper


type of underground
cable

67 The filling compound dry air jelly compound Both none dry air
used in Paper insulated
cable is

68 The filling compound dry air jelly compound Both none jelly compound
used in Polythene
insulated cable is

69 The sheath used in Lead sheath Polythene Both none Both


case of Paper insulated sheath
cables

70 The Sheath used in Lead sheath Polythene Both none Polythene


case of Polythene sheath sheath
insulated cables

71 The thickness of steel 0.5 mm 0.8 mm 0.7 mm none 0.5 mm


tape used for the cables
of diameter upto 40 mm
is

72 The thickness of steel 0.5 mm 0.8 mm 0.7 mm none 0.8 mm


tape used for the cables
of diameter above40 mm
is

73 Which are the standard aerial tape steel corrugated steel all of the all of the
armourings used in armour armouring armouring and above above
underground cables jacketing

74 Various markings used telephone year of size of the all of the all of the
in underground cables handset manufacture conductor and above above
emblem and and capacity of length marking
name of the cable pairs
manufacturer

75 LSDC , PCUT , PCQT , junction paper insulated PIJF cables PCM paper insulated
PCQL are the examples cables cables cables cables
of

76 Paper core cables are 1200 1800 1500 2000 1800


available up to ---pairs

77 PIJF cables are available 2000 2400 3600 4800 3600


up to ------pairs
78 If R1 and R2 are the 20% 30% 25% 50% 25%
resistances of the
individual conductors
having values 200 ohms
and 300 ohms then
percentage of resistance
unbalance is

79 Find the odd one out white red black slate slate
wro primary and
secondary colours of
underground cable

80 Find the odd one out blue orance Green yellow yellow
wro primary and
secondary colours of
underground cable

81 The colour binder for first marker intermediate last marker is the
position of the unit in the is red marker are black intermediate
layers which of the white marker is
following is false orange

82 200 pair contains 2 x 100 pair 4 x 50 pair we can not none 4 x 50 pair
units units say units

83 400 pair cable contains 4 x 100 pair 8 x 50 pair 2 x 100 and 4 none 8 x 50 pair
units units x 50 pair units units

84 800 pair cable contains 16 x 50 pair 8 x 100 pair 4 x 100 and 8 none 8 x 100 pair
units units x 50 pair units units

85 The number of superunits clockwise anticlock wise any direction none clockwise
are counted in ------
direction wrt red marker

86 Guage of 0.32mm to primary secondary Distribution PCM primary cable


0.4mm cables are used cable cable Cables cables
for

87 Guage of 0.4mm to primary secondary Distribution PCM secondary


0.5mm cables are used cable cable Cables cables cable
for

88 Guage of 0.5mm to primary secondary Distribution PCM Distribution


0.63mm cables are used cable cable Cables cables Cables
for

89 Guage of 0.63mm to primary secondary Distribution PCM PCM cables


0.9mm cables are used cable cable Cables cables
for

90 Which of the following armoured unarmoured both are true none of the both are true
statements are true cables are cables are above
laid direct in laid in the
the ground duct

91 The depth of the cable 1.2 m 1.65 m 0.5 m none 1.2 m


trench for underground
cable is

92 TSF -1 kit is used for 20 pair cable 20 pair cable / 20 pair cable / none 20 pair cable /
jointing of / 0.63 mm 0.51 mm guage 0.9 mm guage 0.63 mm guage
guage

93 TSF-2 kit is used for 20 pair 50 pair cable/ both are true none both are true
jointing cable /0.9 0.63 mm
mm guage guage

94 TSF-3 kit is used for 50 pair cable 100 pair cable both are true none both are true
jointing --pair cables / 0.9 mm / 0.63 mm
guage guage

95 TSF-4 Kit is use for 100 pair 400 pair cable/ both are true none both are true
jointing -pairs of cables cable /0.9 0.51 mm
mm guage guage

96 TSF-5 Kit is use for 200 pair 800 pair / 0.51 both are true none both are true
jointing -pairs of cables cable /0.9 mm guage
mm guage

97 Which of the following The cross the voltage the cross all of the all of the
statements are true insulation developed by insulation above above
test is to insulation resistance
be megger is value is about
conducted about 500 5000 mega
by insulation volts ohms
megger

98 Total no of exchanges true false true


installed is equal to sqrt(
total line cost / total
exchange cost )

99 CKM per del shown in Up to 500 Up to 5000 Multi exchange all of the all of the
L-14 diagrams which is lines its lines its value areas up to above above
true value is 5 is 8 20000 lines it is
10

100 Utilization of various primary secondary distribution all of the all of the
cables is shown . Which cable cable Cables above above
is/ are correct statements utilization utilization is up utilization is up
should be to 85 percent to 75%
90%