Professional Documents
Culture Documents
3 Which is used to connect A) Drop wire B) Jumper C)Under D)None B) Jumper wire
indoor switch board wire Ground cables
cables to outdoor cables
in MDF
4 Which is used for the A) Drop wire B) Jumper C)Under D)None A) Drop wire
connection from DP to wire Ground cables
customer premisses
8 MDF stands for --------- A) Main B) Media Drop C)Media drop D)None A) Main
distribution Frame furniture distribution
Frame Frame
9 Switch board cables are A)copper & B) Copper & C)Aluminium & D)None A)copper &
fabricated with 99.97% PVC rubber PVC PVC
pure solid electrolyte
grade--------and in house
developed ----------------
insulation
10 Which is used for A) Drop wire B) Jumper C)Under D)None B) Jumper wire
connecting cable wire Ground cables
termination to exchange
equipment in MDF
13 The Pairs in under A) Colour B) Pair Size C)Pair Count D)None A) Colour code
ground cables are code
identified by
14 The Pairs in under A) 20, 50, B) 25, 60 , 120 C)15, 135 , 150 D)None A) 20, 50, 100,
ground cables are 100, 200 Pairs , 250 pairs 200 pairs
pairs
15 Each Jumper wire in A) Sealed B) Individual C) Twisted Pair D)None C) Twisted Pair
MDF is made of pair
18 A cable connected for Distribution Secondary Primary cable switch switch board
internal equipment in cable cable board cable cable
exchanges i
20 The switch board cables 64 pr tag 100 pr tag 200 pr tag none 64 pr tag
terminated in blocks blocks blocks blocks
21 The tools required for G-Clamp Lacing Twine Runway all all
stitching switch board
cables are
22 The tool used for Krown tool Blow lamp Crimping tool none Krown tool
termination of switch
board cables at MDF is
23 The tool used for Krown tool Blow lamp Crimping tool none Crimping tool
termination of switch
board cables at exchange
side is
25 The cables used for Long Junction Cable Local cable none Local cable
local subscriber network distance
is called cable
26 The cables used to link Long Junction Cable Local cable none Junction Cable
two exchanges are distance
known as cable
27 The cables used to Long Junction Cable Local cable none Long distance
connect two major towns distance cable
is known as cable
28 PCM Cables are Long Junction Cable Local cable none Junction Cable
examples of distance
cable
29 Coaxial cables are Optical Fiber Under ground Junction Cables None Optical Fiber
replaced by --cables for cables cables cables
better performance
30 The cables erected as Switch board Aerial cables Junction cables none Aerial cables
over head cables are cables
31 The planning period of 20 years 7-10 years 5 years none 7-10 years
Primary cables is
32 The planning period for 20 years 7-10 years 5 years none 20 years
distribution cables is
35 DP points are installed wall mounted Pole mounted Both none both
as
36 which is used to provide Switch board Distribution Drop wire Primary Drop wire
connection between cables cables cable
subscriber premisses to
DP
39 Protection devices like exchange Line Side IDF DSLAM Line Side
IPM are equipped on the side
-----side of MDF
40 GD tube stands for Gas Gas damage Gas distribution none Gas Discharge
Discharge tube tube tube
tube
41 The tool used for Insertion tool Crimping tool Nipper None Insertion tool
connecting wire to IDC (
insulation displacement
contact ) type connection
42 Tool used for jointing Insertion tool Crimping tool Nipper None Crimping tool
PIJF cables with U-Y
connectors is
45 UG cables on terminated 64 pr tag 100 pr tag 200 pr tag none 100 pr tag
on -pair tag blocks blocks blocks blocks blocks
47 A MDF vertical Tag block tag number vertical column none vertical column
representation 001-04-96 number
the digits 001 denotes
48 The counting of vertical Right to left left to right top to bottom bottom to Right to left
columns in MDF is from top
49 A MDF vertical Tag block tag number vertical column none Tag block
representation 001-04-96 number number
the digits 04 denotes
50 A MDF vertical Tag block tag number vertical column none tag number
representation 001-04-96 number
the digits 96 denotes
54 TSF-3 kit is used for 20pair 50 pair 100 pair 800 pair 100 pair
jointing --pair cables
57 The coaxial cables are Optical fiber PCM cables Distribution Primary Optical fiber
replaced by -- cables for cables Cables cables cables
long distance working
58 Which statements are planning planning planning period all of the all of the
true period for period for for Distribution above above
primary Secondary cable is 20
cable is 5 cable is 10 years with over
years with years with provisioning
over over factor of 1.3
provisioning provisioning
factor of 1.1 factor of 1.2
59 The distribution cable less more very less cannot say more
laid should be --- than
the primary cable
60 The color code of 81st blue white orange white green white yellow white blue white
pair in 100 pair cable
67 The filling compound dry air jelly compound Both none dry air
used in Paper insulated
cable is
68 The filling compound dry air jelly compound Both none jelly compound
used in Polythene
insulated cable is
73 Which are the standard aerial tape steel corrugated steel all of the all of the
armourings used in armour armouring armouring and above above
underground cables jacketing
74 Various markings used telephone year of size of the all of the all of the
in underground cables handset manufacture conductor and above above
emblem and and capacity of length marking
name of the cable pairs
manufacturer
75 LSDC , PCUT , PCQT , junction paper insulated PIJF cables PCM paper insulated
PCQL are the examples cables cables cables cables
of
79 Find the odd one out white red black slate slate
wro primary and
secondary colours of
underground cable
80 Find the odd one out blue orance Green yellow yellow
wro primary and
secondary colours of
underground cable
81 The colour binder for first marker intermediate last marker is the
position of the unit in the is red marker are black intermediate
layers which of the white marker is
following is false orange
82 200 pair contains 2 x 100 pair 4 x 50 pair we can not none 4 x 50 pair
units units say units
83 400 pair cable contains 4 x 100 pair 8 x 50 pair 2 x 100 and 4 none 8 x 50 pair
units units x 50 pair units units
84 800 pair cable contains 16 x 50 pair 8 x 100 pair 4 x 100 and 8 none 8 x 100 pair
units units x 50 pair units units
85 The number of superunits clockwise anticlock wise any direction none clockwise
are counted in ------
direction wrt red marker
90 Which of the following armoured unarmoured both are true none of the both are true
statements are true cables are cables are above
laid direct in laid in the
the ground duct
92 TSF -1 kit is used for 20 pair cable 20 pair cable / 20 pair cable / none 20 pair cable /
jointing of / 0.63 mm 0.51 mm guage 0.9 mm guage 0.63 mm guage
guage
93 TSF-2 kit is used for 20 pair 50 pair cable/ both are true none both are true
jointing cable /0.9 0.63 mm
mm guage guage
94 TSF-3 kit is used for 50 pair cable 100 pair cable both are true none both are true
jointing --pair cables / 0.9 mm / 0.63 mm
guage guage
95 TSF-4 Kit is use for 100 pair 400 pair cable/ both are true none both are true
jointing -pairs of cables cable /0.9 0.51 mm
mm guage guage
96 TSF-5 Kit is use for 200 pair 800 pair / 0.51 both are true none both are true
jointing -pairs of cables cable /0.9 mm guage
mm guage
97 Which of the following The cross the voltage the cross all of the all of the
statements are true insulation developed by insulation above above
test is to insulation resistance
be megger is value is about
conducted about 500 5000 mega
by insulation volts ohms
megger
99 CKM per del shown in Up to 500 Up to 5000 Multi exchange all of the all of the
L-14 diagrams which is lines its lines its value areas up to above above
true value is 5 is 8 20000 lines it is
10
100 Utilization of various primary secondary distribution all of the all of the
cables is shown . Which cable cable Cables above above
is/ are correct statements utilization utilization is up utilization is up
should be to 85 percent to 75%
90%