• Alert recipients and operators to The ShockLog 298 is the flagship Sensors can be added to the ShockLog
inspect goods and equipment for model in the SpotSee series of impact 298 to record external temperature,
potential damage recorders, which includes the ShockLog humidity, pressure, tilt, and roll
248, SpotBot Cellular, and g-View conditions.
• Determine baseline damage
impact recorders.
boundaries An optional GPS module allows you to
With user-programmable impact scale capture the location of alarms and unit
• Detect mishandling during shipping,
and frequency filters, the ShockLog summaries. With the optional cellular
operation and storage,enabling you
298 offers the most flexible option for module, it’s possible to receive real-
to identify and assign accountability
customers. The ShockLog 298 monitors time notifications when out of tolerance
and take corrective action
impact events, vibration, and internal conditions occur. An optional satellite
• Make adjustments to product temperature and provides peak value module provides connectivity even in
packaging, loading process, (time slot) and summary period journey areas where cellular service does not
carriers, or mode of transport profile data. The ShockLog 298 will exist. Know with GPS accuracy, the
• Help identify opportunities record the detailed impact curve of up location of out of tolerance conditions
for improvement through to 870 events. In addition to impact and summary positions.
journey profiling recording, optional accessories allow
you to tailor the ShockLog 298 for your
requirements.
IP Rating IP67
Cut-off Frequency Options (programmable) 10Hz, 40Hz, 50Hz, 90Hz, 120Hz and 250Hz
Battery Life (Lithium*) Up to 75 days (1 hour summaries) / Up to 190 days (24 hour summaries)
*Always use lithium batteries for journeys where the temperature may be outside the -5°C to +50°C range. The capacity of alkaline batteries drops
dramatically when exposed to temperatures below 10°C. If using a lithium battery and the ShockLog will be traveling by air, make sure the battery
is aproved for air cargo. If the batteries are accidentally installed with the wrong polarity, the ShockLog will not be damaged; however, the life of
the battery may be severely affected.
Resolution 0.1º
Transverse Sensitivity 5%
*Always use lithium batteries for journeys where the temperature may be outside the -5°C to +50°C range. The capacity of alkaline batteries drops
dramatically when exposed to temperatures below 10°C. If using a lithium battery and the ShockLog will be traveling by air, make sure the battery
is aproved for air cargo. If the batteries are accidentally installed with the wrong polarity, the ShockLog will not be damaged; however, the life of
the battery may be severely affected.