You are on page 1of 2

SIS INSPECTION SERVICES

No-26, Kanniamman koil street,SIDCO


Industrial Estate, Ambattur, Chennai - 98
Ph : 044-24717182, 9282106896, Mobile : 9444298642
Email : sisinspectionservice@gmail.com

PENETRANT INSPECTION REPORT

Name of the client GRC Date of Inspection 06.04.2023


Report No PT- 23/04/001 Place of Inspection CHENNAI

JOB DETAILS
Parasol Roof Truss Bracing
Location Shiv Nadar School, Adyar Job description
65NB,100NB, 150 NB, 200 NB
PARASOL ROOF TRUSS WELD AREA + Heat Affected
Job Name Area of Testing
BRACING Zone

INSPECTION DETAILS
Visible Dye/Solvent
Technique Penetrant Type Solvent Removable
wiping
Type of Developer Solvent Suspendiable Penetrant B.no Magnaflux – SKL-WP (B.No21G73)
Magnaflux – SKD-S2
Developer B.no Cleaner B.no Magnaflux – SKC-I (B.No22L02)
(B.No22J14)
Reference std. ASME Sec (V) Article - 6 Acceptance Std. ASME Sec (VIII) Div 1 & 2

S/No Description Observation Result


Parasol Roof Truss Bracing No significant
1 ACCEPTED
Joint No 1 - 16 Indications found

________________

INSPECTED BY
PURUSHOTHAMAN.T
ASNT – LEVEL - II
________________

INSPECTED BY
PURUSHOTHAMAN.T
ASNT – LEVEL - II