Professional Documents
Culture Documents
Tool Measurement
Hardwired
Multidirectional
Axes Compensation
1
Copyright
Passing on as well as duplication of this documentation, evaluation and communication of its
content are prohibited without specific authorization. Contraventions are subject to damages.
All rights reserved.
Decisive for the technical contents is the language version of the manufacturer (DE/EN).
Subject to technical change without any notice.
Original operating instructions
© 2015 ‐ 2017 by Blum‐Novotest GmbH
2
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.1 Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2. Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3. System overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.2 Display elements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
3.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4. Mounting and commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.1 Mounting variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
4.1.1 Mounting variant with cable (outgoing) on side . . . . . . . . . . . . . . . . . . . .10
4.1.2 Mounting variant with cable (outgoing) downward . . . . . . . . . . . . . . . . .11
4.1.3 Mounting variant horizontal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4.1.4 Mounting variant with nozzle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4.2 Adjustment of probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
4.2.1 Cable (outgoing) on side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
4.2.2 Cable (outgoing) downward . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
4.3 Pre‐assembling probe contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
4.4 Mounting probe contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
5. Electrical connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.1 Output signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
6. Notes concerning measuring sequence. . . . . . . . . . . . . . . . . . . . . . . . 20
7. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7.1 Cleaning of tool setting probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
7.2 Changing of the probe contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
8. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
9. Order numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
10. Shipping instructions / storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
11. EC Declaration of Incorporation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
12. Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
1. Introduction
Please read and observe the notes included in these instructions.
Subject to technical change without any notice.
1.1 Keys
CAUTION!
signifies a danger, which may cause injuries, if it is not avoided.
NOTICE
signifies measures to avoid material damages.
Additional advice
The CE‐label confirms, that the product as described complies with the product‐spe‐
cific European regulations.
green red
Md tightening torque
UB operating voltage
2. Safety
CAUTION!
Damages of the measuring system due to misuse are possible.
Handle the measuring system like a precision tool.
Keep the measuring system clean.
Limit the measuring block over travel by programming, see chapter 6..
Read and observe all notes of the machine tool manufacturer. Do not disable safety inter‐
lockings.
NOTICE
Damage of the measuring system by a short circuit is possible
Aggressive liquids may destroy seals.
Do not operate the measuring system in a working environment with aggressive coolants!
Coolants must not contain aggressive contents, that can damage plastics or rubber parts
(e.g.: acetone, alcohol, ethanol, methanol, cleaning benzine, solvents, ...).
Coolants may not exceed a ph‐level of 9.5.
Please contact us if you have any questions! We also have solutions for special applications.
3. System overview
3.1 Description
1
7
8
9
11
12
16 15 14 13
Fig. 3‐1
Probe deflected
Tab. 3‐1
3.3 Dimensions
Z- X/Y
Ø 30 1° a
11° 11°
5,3 5,3 1°
Ø 20 0,02 A
6
4
63,5
Ø11
Ø5,2
46,9
9,5
A
5
35
43
Fig. 3‐2
a adjustment range X/Y
9,5
5
Ø16,5
9,2
Ø5,2
Tab. 3‐2
CAUTION!
Physical injuries and material damages caused by compressed air
Make sure that the components are depressurised during installation work.
Avoid visual and skin contact with air blow.
NOTICE
Damages caused by improper installation/dismounting
Please only use original replacement parts as well as the provided special tools.
Consider the maximum tightening torque.
NOTICE
Damage to measuring system by lacking cable fixation possible.
Fix the spiral hose with a pipe clamp as close as possible on the device.
Observe the minimum bending radius, see chap. 3.4.
NOTICE
If the cable is layed flexibly:
Provide sufficient strain relief.
Limit the movable part of the spiral hose by pipe clamps.
To change or remove the spiral hose before the mounting of the touch probe, bring the hose
nut on slight strain and turn it counter clockwise.
15
Fig. 4‐1
(15) Hose nut
NOTICE
Damage to measuring system by lacking cable fixation possible.
Provide sufficient strain relief.
Observe the minimum bending radius, see chap. 3.4.
35
M3
35
Ø 17,5 ... 25
Fig. 4‐4
22
23
Fig. 4‐5
(22) P83.0175‐045.284
(23) P83.0175‐045.26x
12
16
0,5
Fig. 4‐6
Adjustment possibility with rounded washer, in order to compensate possible angle errors of
the installation.
1. Insert the rounded washer into the recess of the bottom of the housing.
2. Adjust the probe by reciprocal loosening and tightening of the diagonally opposite hexagon
screws (Md = 1.1 Nm).
21 18
7,8
20
19
(18) Rounded washer for probe with (20) Adjusting washer for probe with downwards
downwards facing cable facing cable
(19) O‐ring (21) DIN EN ISO 4762 ‐ M3 x 20 (DIN 912)
Adjustment possibility with rounded washer, in order to compensate possible angle errors of
the installation.
1. Insert the rounded washer into the recess of the bottom of the adjusting washer.
2. Make sure that the O‐ring is inserted and without any damage.
3. Adjust the probe by reciprocal loosening and tightening of the diagonally opposite hexagon
screws (Md = 1.1 Nm).
NOTICE
Damage to the predetermined breaking point by improper mounting possible.
Mounting probe contact ‐ Adapter with predetermined breaking point:
Lock with a flat wrench on spanner flat (Md = 0.5 Nm).
The predetermined breaking point may not be damaged during mounting.
10
D C 8
Fig. 4‐8
NOTICE
Damage to the measuring system by improper mounting possible.
The measuring element may not be deflected during mounting.
When mounting please always use the provided tools.
NOTICE
Damage to the measuring system by improper mounting may be possible.
Please ensure the correct usage and position of the mounting tools when changing the
probe contact, see Fig. 4‐9.
Fig. 4‐9
7 5
5 5
8
C
10 D
9
Fig. 4‐10
(5) DIN EN ISO 4027 ‐ M3 (DIN 914) (10) Predetermined breaking point
(7) Probe contact (C) Flat wrench 6 mm
(8) Adapter with predetermined break‐ (D) Allen key 1.5 mm
ing point
(9) Chip protection
5. Electrical connection
NOTICE
Damage and malfunction of the measuring system is possible caused by faulty cable mount‐
ing
Connect or disconnect connecting cables or plug connections without power supply only.
Observe fail‐safe cable laying according to the regulations for measuring system cables.
Connect the cable shielding on the control side with the machine earth. At adapter connec‐
tions the shielding must be directed over the plug housing and the complete plug connec‐
tion must be mounted isolated.
Observe intactness of gasket and adjusting groove of plug connector.
Tighten the plug connector firmly (Md = 2.0 ... 2.5 Nm).
NOTICE
Damage to the measuring system by short circuit possible.
The outputs cannot be connected in parallel!
Connect each individual wire to its own terminal.
NOTICE
Damages of the measuring system by chips are possible.
Never install cables and wires without protection in the working area.
Protect cables and wires in the working area against flying chips, e.g. by protection hose,
protection spring, cover, etc.
CNC
GY STATUS x.xx
1,5m YE STATUS
10m BN 24V
WH 0V
Fig. 5‐1
H
STATUS
L
H
STATUS
L
LED Status GN RD GN
Fig. 5‐2
NOTICE
Measuring error is possible.
Observe max. feedrate of the machine manufacturer.
Execute calibration and tool measurement at the same constant feedrate.
7. Maintenance
• The probe needs minimum maintenance only
• Depending on application conditions lubricate the measuring surface occasionally, e.g.with
multi‐function oil WD40.
NOTICE
Pollution and damage to the measuring mechanism
The bellows is allowed to be exchanged by Blum‐Novotest only!
In case of damage to the bellows, please return the measuring system for repair.
Fig. 7‐1
1. Remove the chip protection and the probe contact, see chapter 7.2.
2. Clean all parts with a brush and check the bellows for damages.
3. Mount the chip protection and the probe contact, see chapter 7.2.
4. Check the probe after assembly concerning parallelism. The probe may not clamp on oper‐
ation.
5. Calibrate the measuring system by the calibration cycle.
7 5
5 5
8
C
10 D
Fig. 7‐2
(5) DIN EN ISO 4027 ‐ M3 (DIN 914) (10) Predetermined breaking point
(7) Probe contact (C) Flat wrench 6 mm
(8) Adapter with predetermined break‐ (D) Allen key 1.5 mm
ing point
(9) Chip protection
8. Troubleshooting
Keys
= Remedy / Workaround
Setscrews on protection ring resp. chip protection are tightened too much
Check setscrews
Setscrews: pay attention to tightening torque ( 0.3 Nm)
9. Order numbers
Use original parts and accessories by Blum‐Novotest only.
Nozzle P83.0175‐045.284
Company:
Department:
Contact:
Address:
Phone:
Fax:
Email:
Measuring system type, serial No.:
Machine type, manufacturer:
Description of defect:
12.Service
Blum‐Novotest GmbH
Kaufstr. 14
88287 Gruenkraut, Germany
Tel.:+49 751 6008‐0
Fax:+49 751 6008‐156
www.blum‐novotest.com
Sales: vk@blum‐novotest.com
Service: snc@blum‐novotest.com
Hotline:
Sales: Tel.:+49 751 6008‐200
Service LaserControl: Tel.:+49 751 6008‐202
Service probes: Tel.:+49 751 6008‐203
Worldwide:
Blum‐Novotest GmbH Test Engineering Blum‐Novotest K.K.
Willich, Germany Nagoya, Japan
Tel. +49 2154 921970 Tel. +81 568 74‐5311
Blum‐Novotest Srl Blum‐Novotest Trading (Shanghai) Ltd.
Como, Italy Shanghai, China
Tel. +39 031 283 955 Tel. +86 21 52080480
Blum‐Novotest Ltd. Blum Production Metrology Co., Ltd.
Birmingham, England Taichung, Taiwan
Tel. +44 1283 569691 Tel. +886 4 2358 3900
Blum‐Novotest Sarl Blum Production Metrology Pte. Ltd.
Bordeaux, France Singapore, Singapore
Tel. +33 55702 0135 Tel. +65 62720998
Blum‐Novotest s.r.o. Blum‐Novotest Ltd.
Kroměříž, Czech Republic Seoul, Republic of Korea
Tel. +420 573 330373 Tel. +82 2 2026‐7660
Blum‐Novotest AB Blum‐Novotest Measuring & Testing
Skövde, Sweden Technology Pvt Ltd, Bangalore, India
Tel. +46 500 448991 Tel. +91 80 23185468
Blum‐Novotest, Inc. Blum‐Novotest Sistemas de Medição Ltda, São
Cincinnati, USA Paulo, Brazil
Tel. +1 859 525‐2586 Tel. +55 19 41413458