You are on page 1of 28

ZX‐Speed

Tool setting probe

Tool Measurement

Hardwired

Multidirectional

Wear‐Free Measuring Sys‐


tem

Tool Breakage Detection

Tool Length Measurement

Tool Radius Measurement

Axes Compensation

Operating instructions English

Type 322010001 | 322010002

1
Copyright
Passing on as well as duplication of this documentation, evaluation and communication of its
content are prohibited without specific authorization. Contraventions are subject to damages.
All rights reserved.
Decisive for the technical contents is the language version of the manufacturer (DE/EN).
Subject to technical change without any notice.
Original operating instructions
© 2015 ‐ 2017 by Blum‐Novotest GmbH

2
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.1 Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2. Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3. System overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.2 Display elements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
3.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4. Mounting and commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.1 Mounting variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
4.1.1 Mounting variant with cable (outgoing) on side . . . . . . . . . . . . . . . . . . . .10
4.1.2 Mounting variant with cable (outgoing) downward . . . . . . . . . . . . . . . . .11
4.1.3 Mounting variant horizontal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4.1.4 Mounting variant with nozzle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4.2 Adjustment of probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
4.2.1 Cable (outgoing) on side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
4.2.2 Cable (outgoing) downward . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
4.3 Pre‐assembling probe contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
4.4 Mounting probe contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
5. Electrical connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.1 Output signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
6. Notes concerning measuring sequence. . . . . . . . . . . . . . . . . . . . . . . . 20
7. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7.1 Cleaning of tool setting probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
7.2 Changing of the probe contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
8. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
9. Order numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
10. Shipping instructions / storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
11. EC Declaration of Incorporation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
12. Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

© by Blum‐Novotest 3 322000010S | V1B | 07/2017


Introduction

1. Introduction
Please read and observe the notes included in these instructions.
Subject to technical change without any notice.

1.1 Keys

CAUTION!
signifies a danger, which may cause injuries, if it is not avoided.

NOTICE
signifies measures to avoid material damages.

Advice for secondary literature

Additional advice

Don’t use compressed air for this step.

The CE‐label confirms, that the product as described complies with the product‐spe‐
cific European regulations.

green red

Md tightening torque
UB operating voltage

322000010S | V1B | 07/2017 4 © by Blum‐Novotest


Safety

2. Safety
CAUTION!
Damages of the measuring system due to misuse are possible.
 Handle the measuring system like a precision tool.
 Keep the measuring system clean.
 Limit the measuring block over travel by programming, see chapter 6..
 Read and observe all notes of the machine tool manufacturer. Do not disable safety inter‐
lockings.

NOTICE
Damage of the measuring system by a short circuit is possible
Aggressive liquids may destroy seals.
 Do not operate the measuring system in a working environment with aggressive coolants!
Coolants must not contain aggressive contents, that can damage plastics or rubber parts
(e.g.: acetone, alcohol, ethanol, methanol, cleaning benzine, solvents, ...).
 Coolants may not exceed a ph‐level of 9.5.
 Please contact us if you have any questions! We also have solutions for special applications.

© by Blum‐Novotest 5 322000010S | V1B | 07/2017


System overview

3. System overview
3.1 Description
1

7
8
9

11
12

16 15 14 13
Fig. 3‐1

(1) Measuring surface (12) Rounded washer


(7) Probe contact (13) Cable
(8) Adapter with predetermined break‐ (14) Spiral hose
ing point (15) Hose nut
(9) Chip protection (16) DIN EN ISO 4762 M3 x 14 (DIN 912)
(11) LED

3.2 Display elements

Colour LED (11)


Standby

Probe initial position

Probe deflected

Tab. 3‐1

322000010S | V1B | 07/2017 6 © by Blum‐Novotest


System overview

3.3 Dimensions
Z- X/Y

Ø 30 1° a
11° 11°
5,3 5,3 1°
Ø 20 0,02 A
6
4
63,5

Ø11
Ø5,2
46,9

9,5
A
5

35
43
Fig. 3‐2
a adjustment range X/Y
9,5
5

Ø16,5
9,2

Ø5,2

Fig. 3‐3 Downwards facing cable

© by Blum‐Novotest 7 322000010S | V1B | 07/2017


System overview

3.4 Technical data

Protection class IP68


Power supply UB 12 ... 30 V DC (stabilized) / 100 mA
Outputs 12 ... 30 V / 50 mA
Approach direction ±X, ±Y, ‐Z
Measuring force
• direction X/Y: 1.7 N
• direction Z: 3N
max. stroke / deflection
• direction X/Y: ±11° (5.3 mm)
• direction Z: 6 mm
Repeatability 0.4 µm 2
Max. probing speed 2 m/min
Min. tool diametera 1 mm
Mass, incl. cable 10 m 700 g
Min. bending radius cable
• static 26 mm
• flexible 60 mm
Storage temperature ‐20 °C ... +70 °C
Operating temperature +5 °C ... +50 °C
a
Depending on tool geometry and material as well as probing speed, the tool may not be damaged by the
probing force.

Tab. 3‐2

322000010S | V1B | 07/2017 8 © by Blum‐Novotest


Mounting and commissioning

4. Mounting and commissioning


CAUTION!
Physical injuries and material damages of the components caused by voltage
 Make sure that the components are volt‐free during installation work.

CAUTION!
Physical injuries and material damages caused by compressed air
 Make sure that the components are depressurised during installation work.
 Avoid visual and skin contact with air blow.

NOTICE
Damages caused by improper installation/dismounting
 Please only use original replacement parts as well as the provided special tools.
 Consider the maximum tightening torque.

© by Blum‐Novotest 9 322000010S | V1B | 07/2017


Mounting and commissioning

4.1 Mounting variants

4.1.1 Mounting variant with cable (outgoing) on side

NOTICE
Damage to measuring system by lacking cable fixation possible.
 Fix the spiral hose with a pipe clamp as close as possible on the device.
 Observe the minimum bending radius, see chap. 3.4.

NOTICE
If the cable is layed flexibly:
 Provide sufficient strain relief.
 Limit the movable part of the spiral hose by pipe clamps.
To change or remove the spiral hose before the mounting of the touch probe, bring the hose
nut on slight strain and turn it counter clockwise.

15

Fig. 4‐1
(15) Hose nut

322000010S | V1B | 07/2017 10 © by Blum‐Novotest


Mounting and commissioning

4.1.2 Mounting variant with cable (outgoing) downward

NOTICE
Damage to measuring system by lacking cable fixation possible.
 Provide sufficient strain relief.
 Observe the minimum bending radius, see chap. 3.4.

35

M3
35
Ø 17,5 ... 25

Fig. 4‐2 Adjustment unit P83.0175‐044.081 (option)

Fig. 4‐3 Mounting system (option)

© by Blum‐Novotest 11 322000010S | V1B | 07/2017


Mounting and commissioning

4.1.3 Mounting variant horizontal


In case of horizontal mounting of the stylus, a cover will be necessary.
Make sure that no chips pile up at the stylus. Depending on the environmental conditions, the
cleaning interval is needed more frequently.

Fig. 4‐4

4.1.4 Mounting variant with nozzle

Installation instruction of mounting system | nozzle

22

23

Fig. 4‐5

(22) P83.0175‐045.284
(23) P83.0175‐045.26x

322000010S | V1B | 07/2017 12 © by Blum‐Novotest


Mounting and commissioning

4.2 Adjustment of probe

4.2.1 Cable (outgoing) on side



12

16
0,5

Fig. 4‐6

(12) Rounded washer


(16) DIN EN ISO 4762 ‐ M3 x 14 (DIN 912)

Adjustment possibility with rounded washer, in order to compensate possible angle errors of
the installation.
1. Insert the rounded washer into the recess of the bottom of the housing.
2. Adjust the probe by reciprocal loosening and tightening of the diagonally opposite hexagon
screws (Md = 1.1 Nm).

© by Blum‐Novotest 13 322000010S | V1B | 07/2017


Mounting and commissioning

4.2.2 Cable (outgoing) downward


0,6°
0,6°

21 18
7,8

20
19

Fig. 4‐7 Adjustment unit P83.0175‐044.081 (option)

(18) Rounded washer for probe with (20) Adjusting washer for probe with downwards
downwards facing cable facing cable
(19) O‐ring (21) DIN EN ISO 4762 ‐ M3 x 20 (DIN 912)

Adjustment possibility with rounded washer, in order to compensate possible angle errors of
the installation.
1. Insert the rounded washer into the recess of the bottom of the adjusting washer.
2. Make sure that the O‐ring is inserted and without any damage.
3. Adjust the probe by reciprocal loosening and tightening of the diagonally opposite hexagon
screws (Md = 1.1 Nm).

322000010S | V1B | 07/2017 14 © by Blum‐Novotest


Mounting and commissioning

4.3 Pre‐assembling probe contact

NOTICE
Damage to the predetermined breaking point by improper mounting possible.
 Mounting probe contact ‐ Adapter with predetermined breaking point:
Lock with a flat wrench on spanner flat (Md = 0.5 Nm).
 The predetermined breaking point may not be damaged during mounting.

10
D C 8
Fig. 4‐8

(7) Probe contact (C) Flat wrench 6 mm


(8) Adapter with predetermined break‐ (D) Allen key 1.5 mm
ing point
(10) Predetermined breaking point

© by Blum‐Novotest 15 322000010S | V1B | 07/2017


Mounting and commissioning

4.4 Mounting probe contact

NOTICE
Damage to the measuring system by improper mounting possible.
 The measuring element may not be deflected during mounting.
 When mounting please always use the provided tools.

NOTICE
Damage to the measuring system by improper mounting may be possible.
 Please ensure the correct usage and position of the mounting tools when changing the
probe contact, see Fig. 4‐9.

Fig. 4‐9

7 5
5 5
8
C
10 D
9

Fig. 4‐10

(5) DIN EN ISO 4027 ‐ M3 (DIN 914) (10) Predetermined breaking point
(7) Probe contact (C) Flat wrench 6 mm
(8) Adapter with predetermined break‐ (D) Allen key 1.5 mm
ing point
(9) Chip protection

322000010S | V1B | 07/2017 16 © by Blum‐Novotest


Mounting and commissioning

 Probe contact with adapter is pre‐assembled, see Fig. 4‐8.


1. Screw the probe contact with the adapter and the chip protection lightly onto the probe.
2. Push the chip protection all the way upwards so that the lower spanner flat is accessible.
Mount the adapter by using a flat wrench (Md = 1.0 Nm).
3. Move the chip protection downwards. Fix the chip protection with the set screws
(Md = 0.5 Nm).
4. Calibrate the measuring system by the calibration cycle.

© by Blum‐Novotest 17 322000010S | V1B | 07/2017


Electrical connection

5. Electrical connection
NOTICE
Damage and malfunction of the measuring system is possible caused by faulty cable mount‐
ing
 Connect or disconnect connecting cables or plug connections without power supply only.
 Observe fail‐safe cable laying according to the regulations for measuring system cables.
 Connect the cable shielding on the control side with the machine earth. At adapter connec‐
tions the shielding must be directed over the plug housing and the complete plug connec‐
tion must be mounted isolated.
 Observe intactness of gasket and adjusting groove of plug connector.
 Tighten the plug connector firmly (Md = 2.0 ... 2.5 Nm).

NOTICE
Damage to the measuring system by short circuit possible.
The outputs cannot be connected in parallel!
 Connect each individual wire to its own terminal.

NOTICE
Damages of the measuring system by chips are possible.
 Never install cables and wires without protection in the working area.
 Protect cables and wires in the working area against flying chips, e.g. by protection hose,
protection spring, cover, etc.

CNC
GY STATUS x.xx
1,5m YE STATUS
10m BN 24V
WH 0V

Fig. 5‐1

Colour / Pin Connection Designation Data


white GND Ground 0V
brown UB Power supply 12 ... 30 V (stabilized) / 100 mA
yellow STATUS Output static 12 ... 30 V / 50 mA
grey STATUS Output static 12 ... 30 V / 50 mA
Housing ‐‐‐ Shielding
Tab. 5‐1

322000010S | V1B | 07/2017 18 © by Blum‐Novotest


Electrical connection

5.1 Output signals


X/Y Z
0 mm
1 mm

H
STATUS
L
H
STATUS
L
LED Status GN RD GN

Fig. 5‐2

© by Blum‐Novotest 19 322000010S | V1B | 07/2017


Notes concerning measuring sequence

6. Notes concerning measuring sequence


NOTICE
Damage to the measuring system due to collision is possible.
 Limit the measuring block over travel by programming, (see Tab. 6‐1).

Probe contact XY: < 4.5 mm


Z: < 5 mm
Tab. 6‐1

NOTICE
Measuring error is possible.
 Observe max. feedrate of the machine manufacturer.
 Execute calibration and tool measurement at the same constant feedrate.

322000010S | V1B | 07/2017 20 © by Blum‐Novotest


Maintenance

7. Maintenance
• The probe needs minimum maintenance only
• Depending on application conditions lubricate the measuring surface occasionally, e.g.with
multi‐function oil WD40.

NOTICE
Pollution and damage to the measuring mechanism
The bellows is allowed to be exchanged by Blum‐Novotest only!
 In case of damage to the bellows, please return the measuring system for repair.

7.1 Cleaning of tool setting probe

Fig. 7‐1
1. Remove the chip protection and the probe contact, see chapter 7.2.
2. Clean all parts with a brush and check the bellows for damages.
3. Mount the chip protection and the probe contact, see chapter 7.2.
4. Check the probe after assembly concerning parallelism. The probe may not clamp on oper‐
ation.
5. Calibrate the measuring system by the calibration cycle.

© by Blum‐Novotest 21 322000010S | V1B | 07/2017


Maintenance

7.2 Changing of the probe contact


5

7 5
5 5
8
C
10 D

Fig. 7‐2

(5) DIN EN ISO 4027 ‐ M3 (DIN 914) (10) Predetermined breaking point
(7) Probe contact (C) Flat wrench 6 mm
(8) Adapter with predetermined break‐ (D) Allen key 1.5 mm
ing point
(9) Chip protection

1. Untighten the setscrews.


2. Push the chip protection all the way upwards so that the lower spanner flat is accessible.
3. Detach the adapter by using the flat wrench and remove it.
4. Pre‐assemble the new probe contact, see Fig. 4‐8.
5. Screw the probe contact with the adapter and the chip protection lightly onto the probe.
6. Push the chip protection all the way upwards so that the lower spanner flat is accessible.
Mount the adapter by using a flat wrench (Md = 1.0 Nm).
7. Move the chip protection downwards. Fix the chip protection with the set screws
(Md = 0.5 Nm).
8. Calibrate the measuring system by the calibration cycle.

322000010S | V1B | 07/2017 22 © by Blum‐Novotest


Troubleshooting

8. Troubleshooting
Keys

Error = Error message


= Error description

= Check the following points

= Remedy / Workaround

Error Probe deflected


Probe doesn’t reach rest position after deflection

Setscrews on protection ring resp. chip protection are tightened too much
Check setscrews
Setscrews: pay attention to tightening torque ( 0.3 Nm)

© by Blum‐Novotest 23 322000010S | V1B | 07/2017


Order numbers

9. Order numbers
Use original parts and accessories by Blum‐Novotest only.

Tool setting probe ZX‐Speed 322010001


Connecting mode ‐1

Tool setting probe ZX‐Speed 322010002


Connecting mode ‐1

Mounting system P83.0175‐045.260, h = 14 mm


(nozzle can be mounted)
for cable outgoing on side
mounting system P83.0175‐045.263, h = 40 mm
(nozzle can be mounted) P83.0175‐045.264, h = 60 mm
for cable outgoing on side and P83.0175‐045.266, h = 125 mm
downward P83.0175‐045.269, h = 150 mm
P83.0175‐045.272, h = 200 mm
mounting system P83.0175‐045.272, h = 250 mm
(nozzle can be mounted)
for cable outgoing on side and
downward

Nozzle P83.0175‐045.284

Adjusting unit for probe with cable P83.0175‐044.081


(outgoing) downward

Spare and wear parts


Spare and wear parts are not subject to warranty.

Probe contact set 322010200

Chip protection for probe 322010040

322000010S | V1B | 07/2017 24 © by Blum‐Novotest


Shipping instructions / storage

10.Shipping instructions / storage


Service order
Please complete this repair order answering all questions in detail and attach it to the system.
It will be more cost effective for both parties if we have all the information and will ensure a
prompt repair service.
Blum‐Novotest GmbH
Kaufstr. 14, 88287 Gruenkraut ‐ Germany
Tel. +49 751 6008‐0, Fax. +49 751 6008‐156

Company:
Department:
Contact:
Address:
Phone:
Fax:
Email:
Measuring system type, serial No.:
Machine type, manufacturer:
Description of defect:

© by Blum‐Novotest 25 322000010S | V1B | 07/2017


EC Declaration of Incorporation

11.EC Declaration of Incorporation


acc. to the EC Machine Regulations 2006/42/EC in the edition from 17 May.2006
We hereby confirm that the subsequently following components are defined for the installation
into other machines and that they are in accordance with the following safety requirements of
the EC regulations.
Commissioning is not allowed until it is ascertained that the machines, in which the compo‐
nents are installed, are in accordance with the EC regulations 2006/42/EC.
The relevant technical information is compiled acc. to annex VII part B and, where appropriate,
we will send the information concerning the components to the different countries. The indus‐
trial property rights of Blum‐Novotest GmbH will remain unaffected.

Component name 322010001


Probe for tool measurement
Safety requirements 1.5.1
2006/42/EC, Annex I
Applied standards:
EC‐Regulations: 2004/108/EC
2006/95/EC
Applied harmonized standards: EN 61000‐6
EN 60204‐1
EN ISO 12100
Applied national standards: DIN VDE 0100
DIN VDE 0113
Authorised representative for technical information: Blum‐Novotest GmbH
Kaufstr. 14
88287 Gruenkraut, Germany

322000010S | V1B | 07/2017 26 © by Blum‐Novotest


Service

12.Service

Blum‐Novotest GmbH
Kaufstr. 14
88287 Gruenkraut, Germany
Tel.:+49 751 6008‐0
Fax:+49 751 6008‐156
www.blum‐novotest.com
Sales: vk@blum‐novotest.com
Service: snc@blum‐novotest.com

Hotline:
Sales: Tel.:+49 751 6008‐200
Service LaserControl: Tel.:+49 751 6008‐202
Service probes: Tel.:+49 751 6008‐203

Worldwide:
Blum‐Novotest GmbH Test Engineering Blum‐Novotest K.K.
Willich, Germany Nagoya, Japan
Tel. +49 2154 921970 Tel. +81 568 74‐5311
Blum‐Novotest Srl Blum‐Novotest Trading (Shanghai) Ltd.
Como, Italy Shanghai, China
Tel. +39 031 283 955 Tel. +86 21 52080480
Blum‐Novotest Ltd. Blum Production Metrology Co., Ltd.
Birmingham, England Taichung, Taiwan
Tel. +44 1283 569691 Tel. +886 4 2358 3900
Blum‐Novotest Sarl Blum Production Metrology Pte. Ltd.
Bordeaux, France Singapore, Singapore
Tel. +33 55702 0135 Tel. +65 62720998
Blum‐Novotest s.r.o. Blum‐Novotest Ltd.
Kroměříž, Czech Republic Seoul, Republic of Korea
Tel. +420 573 330373 Tel. +82 2 2026‐7660
Blum‐Novotest AB Blum‐Novotest Measuring & Testing
Skövde, Sweden Technology Pvt Ltd, Bangalore, India
Tel. +46 500 448991 Tel. +91 80 23185468
Blum‐Novotest, Inc. Blum‐Novotest Sistemas de Medição Ltda, São
Cincinnati, USA Paulo, Brazil
Tel. +1 859 525‐2586 Tel. +55 19 41413458

© by Blum‐Novotest 27 322000010S | V1B | 07/2017