Administration Manual CANoe/CANalyzer MSI Setup Table of Contents
Table of Contents
1 Introduction 3
1.1 MSI Setup at a Glance 4
1.2 About this User Manual 5
1.2.1 Access Helps and Conventions 5
1.2.2 Certification 6
1.2.3 Warranty 6
1.2.4 Support 6
1.2.5 Trademarks 6
2 Setup Prerequisites 7
2.1 Overview 8
2.2 Windows Installer 3.1 8
2.3 .NET Framework 3.5 SP1 8
2.4 Windows Updates for .NET Framework 3.5 SP1 9
2.5 CANoe/CANalyzer Redistributables 9
2.6 CANoe/CANalyzer Redistributables for 64 Bit Operating Systems 9
2.7 Microsoft Visual C++ 2005 SP1 Redistributable 10
2.8 Microsoft Visual C++ 2008 Redistributable 10
2.9 Microsoft Visual C++ 2010 Redistributable 10
2.10 Microsoft Visual C++ 2013 Redistributable 11
2.11 Microsoft Visual C++ 2013 Redistributable (x64) 11
2.12 Microsoft .NET Framework 4.6.1 12
2.13 Vector CANdela Persistors 9.0 12
2.14 Vector ICD Manager 13
2.15 Vector License Manager 1.4 SP3 13
2.16 64 Bit FlexNet Licensing Service 13
2.17 Vector CANdelaStudio 9.0 14
2.18 Vector ODXStudio 4.1 P1 14
2.19 Vector AUTOSAR Explorer 1.7 15
2.20 Vector AUTOSAR Explorer 2.0 15
2.21 Vector FIBEX Explorer 3.3 16
2.22 Vector LDF Explorer 1.4 17
2.23 Vector ASAP2 Viewer 14.0 17
2.24 Vector CANoe CANalyzer Scope for 64 Bit Operating Systems 17
2.25 Vector Aerospace Message Editor 18
2.26 Vector Shell Extensions 18
2.27 CodeMeter Runtime (x86) 19
2.28 CodeMeter Runtime (x64) 19
2.29 Vector CANoe Test Report Viewer 19
2.30 Vector Support Assistant 20
3 Settings 21
3.1 Customizable Properties 22
3.2 Installable Features 24
3.3 Transforms 25
4 Further Installations 27
4.1 Silent Installation Example 28
4.2 Service Pack Installation 30
4.2.1 Prerequisites 30
4.2.2 Silent Update 30
4.3 Special (Traceable) Product Codes for Software Deployment 30
4.4 Interactive Installation using Bootstrapper 32
4.5 Hardware Installation 32
1 Introduction
Installation guide This document provides an installation guide for IT departments who want to install
Vector CANoe/CANalyzer silently on target machines using software deployment
systems.
It is assumed that the reader is familiar with the Windows Installer technology and the
software deployment system used.
After depicting the necessary Setup Prerequisites (chapter 2), this document explains
how the public properties of the installer can be configured in order to install the
required application components and how embedded transforms can be used to
setup CANoe and CANalyzer alongside on the same machine (chapter 1).
This document applies to CANoe/CANalyzer version 9.0 SP2 and up. For an updated
version of this document please always check the documentation that came with your
product before packaging the application as some items mentioned here are version
dependent (e.g. updated installation prerequisites).
Important notes for When silently installing CANoe/CANalyzer using MST transforms, make sure that all
silent installation files and folders from the installation media’s \CANoe or \CANalyzer folder are
present in the folder from where the CANoe_CANalyzer.msi will be called by your
setup scripts (typically a network share or a local temporary folder on the target
system).
In case you have received personalized installer media from Vector (i.e. you have not
received separate installation key information) you may omit setting the public
properties
> VSETUPKEY_CUSTOMER,
> VSETUPKEY_SERIALNUMBER and
> VSETUPKEY_LICENSEKEY
as the installation information (product variant, bus options, serial number etc.) is
already contained in the installer files.
Roaming user Roaming user profiles are not supported by CANoe/CANalyzer. It is highly
profiles recommended to execute the installation on local user profiles only. Usage of roaming
profiles may lead to:
> Inconsistencies of installations, including prerequisites
> Malfunction of future CANoe/CANalyzer updates
Important notes for Every aspect that concerns the 32-bit installation package of CANoe/CANalyzer is
64 bit installation also valid for the 64-bit installation package.
package
Exceptions:
> The name of the installation package is CANoe_CANalyzer64.msi instead of
CANoe_CANalyzer.msi.
> From the installation perspective, the 64-bit variant and the 32-bit variant of
CANoe/CANalyzer are different products. Product codes as well as upgrade
codes are distinct. You cannot apply a service pack installation of the 64-bit
variant on an installation of the 32-bit variant and vice versa.
> Some prerequisites are only necessary for the 64-bit installation. This is explicitly
mentioned in the description of the Setup Prerequisites (chapter 2).
Reference: You can find mor information about the differences between 32-bit and
64-bit variants in the knowledge base article at http://vector.com/CANoe64bit.
To find information The user manual provides you the following access helps:
quickly > at the beginning of each chapter you will find a summary of its contents,
> in the header you see the current chapter and section,
> in the footer you see to which program version the user manual replies.
Conventions In the two following tables you will find the conventions used in the user manual
regarding utilized spellings and icons.
Style Utilization
bold Blocks, surface elements, window and dialog names of the
software. Accentuation of warnings and advices.
[OK] Push buttons in brackets
File|Save Notation for menus and menu commands
CANoe Legally protected proper names and side notes.
Source code File name and source code.
Hyperlink Hyperlinks and references.
<STRG>+<S> Notation for shortcuts.
Symbol Utilization
This icon indicates notes and tips that facilitate your work.
Symbol Utilization
This icon indicates text areas containing expert knowledge.
1.2.2 Certification
1.2.3 Warranty
Restriction of We reserve the right to modify the contents of the documentation or the software
warranty without notice. Vector disclaims all liabilities for the completeness or correctness of
the contents and for damages which may result from the use of this documentation.
1.2.4 Support
You need support? You can get through to our hotline at the phone number
+49 (711) 80670-200
or you send a problem report to the CANoe Support.
1.2.5 Trademarks
Protected All brand names in this documentation are either registered or non registered
trademarks trademarks of their respective owners.
2 Setup Prerequisites
2.1 Overview
Prerequisites Several prerequisites must be met in order to install and/or use CANoe/CANalyzer.
Those prerequisites will be listed in the following sections.
Please ensure that every client meets these prerequisites before installing
CANoe/CANalyzer.
Setup programs You can find the setup programs for all prerequisites in the setup directory on your
CD under CANoe\Redist.
Prerequisites Windows Installer 3.1 (or later) is needed in order to install CANoe/CANalyzer. It is
assumed, that this prerequisite is met.
Prerequisites The .NET Framework 3.5 SP1 needs to be installed in order to use
CANoe/CANalyzer.
Installation check To check if the .NET Framework is installed you can check if the following registry key
is present:
HKEY_LOCAL_MACHINE\SOFTWARE\\Microsoft\\NET Framework
Setup\\NDP\\v3.5
If this registry key exists, the .NET Framework 3.5 is installed (this could also be 3.5
without any Service Pack). Please note that this registry key also exists, when a
higher version of the .NET Framework is installed.
Additionally, the following value must appear below this key and its value must be 1
or greater to be sure that SP 1 is installed:
SP = 1
Note: The .NET Framework 3.5 SP1 is delivered with Windows 7 SP1. You must use
Turn Windows features on or off in the Control Panel to install or configure
Microsoft .NET Framework 3.5 SP1.
For more information on this, see http://social.msdn.microsoft.com/Forums/en-
US/netfxsetup/thread/35d348e5-192e-4fa2-a45a-c1c2175ce111/
Note: The .NET Framework 3.5 SP1 is not delivered with Windows 8. You must use
Turn Windows features on or off in the Control Panel to install or configure
Microsoft .NET Framework 3.5 SP1.
For more information on this, see http://msdn.microsoft.com/library/vstudio/hh506443.
Prerequisites After installing the .NET Framework 3.5 SP1 it is recommended to immediately install
also the update KB959209 in order to address a set of known application compatibility
issues. This update consists of several files which are provided for each relevant
target system. See http://support.microsoft.com/kb/959209/en-us for details.
Installation check It is assumed that there is a strategy for installing Windows updates on your client
and Installation computers and that there are rules on how such Windows updates shall be applied.
Thus no further information on this topic is given here.
Installation check There is no check needed. Just install the redistributable package. The package itself
checks which Redistributables need to be installed
Installation check There is no check needed. Just install the redistributable package. The package itself
checks which Redistributables need to be installed.
Installation check To verify that the Microsoft Visual C++ 2005 SP1 Redistributables are installed, check
if the software with the following product code is installed:
{7299052b-02a4-4627-81f2-1818da5d550d}
Installation To install the Microsoft Visual C++ 2005 SP1 Redistributables silently, use the
following command:
vcredist_x86.exe -Q -C:"msiexec /I vcredist.msi /q"
CANoe/CANalyzer Effective with CANoe/CANalyzer v7.2 SP1 you also have to have the Microsoft Visual
v7.2 SP1 C++ 2008 redistributables package installed.
Installation check To verify that the Microsoft Visual C++ 2008 redistributables are installed, check if the
software with the following product code is installed:
{9A25302D-30C0-39D9-BD6F-21E6EC160475}
Installation To install the Microsoft Visual C++ 2008 redistributables silently, use the following
command:
vcredist_x86_vs2008_SP1.exe /q
CANoe/CANalyzer Effective with CANoe/CANalyzer v8.0 and up you also have to have the Microsoft
v8.0 and up Visual C++ 2010 redistributables package installed.
Installation check To verify that the Microsoft Visual C++ 2010 redistributables are installed, check if the
software with the following product code is installed:
{F0C3E5D1-1ADE-321E-8167-68EF0DE699A5}
The Microsoft Visual C++ 2010 redistributables package may be installed as part of
Microsoft Visual Studio 2010. Therefore, the following product code should also be
checked:
{5D9ED403-94DE-3BA0-B1D6-71F4BDA412E6}
Installation To install the Microsoft Visual C++ 2010 redistributables silently, use the following
command:
vcredist_2010_SP1_x86.exe /q /norestart
CANoe/CANalyzer Effective with CANoe/CANalyzer v8.5 and up you also have to have the Microsoft
v8.5 and up Visual C++ 2013 redistributables package installed.
Installation check Note that the Microsoft Visual C++ 2013 redistributables consist of a minimum run-
time package and an additional run-time package. Both packages need to be
checked.
To verify that the Microsoft Visual C++ 2013 redistributables are installed, check if the
software with the following product code is installed:
Minimum runtime: {F0C3E5D1-1ADE-321E-8167-68EF0DE699A5}
Additional runtime: {3D6AD258-61EA-35F5-812C-B7A02152996E}
The Microsoft Visual C++ 2013 redistributables package may be installed as part of
Microsoft Visual Studio 2013. Therefore, the following product code should also be
checked:
Additional runtime: {5D9ED403-94DE-3BA0-B1D6-71F4BDA412E6}
Installation To install the Microsoft Visual C++ 2013 redistributables silently, use the following
command:
vcredist_x86_VS2013_SP2.exe /install /quiet /norestart
CANoe/CANalyzer Effective with CANoe/CANalyzer v8.5 SP2 and up you also have to have the
v8.5 SP2 and up Microsoft Visual C++ 2013 (x64) redistributables package installed.
32/64 bit installation Effective with CANoe/CANalyzer v9.0 SP4 and up, the Microsoft Visual C++ 2013
(x64) redistributables have to be installed always on 64 bit operating systems.
With lower CANoe/CANalyzer versions, the redistributables have to be installed only
when the 64 bit version of CANoe/CANalyzer is installed.
Installation check Note that the Microsoft Visual C++ 2013 (x64) redistributables consist of a minimum
run-time package and an additional run-time package. Both packages need to be
checked.
To verify that the Microsoft Visual C++ 2013 (x64) redistributables are installed, check
if the software with the following product code is installed:
Minimum runtime: {A749D8E6-B613-3BE3-8F5F-045C84EBA29B}
Additional runtime: {929FBD26-9020-399B-9A7A-751D61F0B942}
Installation To install the Microsoft Visual C++ 2013 (x64) redistributables silently, use the
following command:
vcredist_x64_VS2013_SP2.exe /install /quiet /norestart
Prerequisites The Microsoft .NET Framework 4.6.1 needs to be installed in order to use
CANoe/CANalyzer on Windows 7 SP1 or newer operating systems. Note that
the .NET Framework 4.6.1 does not include the .NET Framework versions up to 3.5.
Installation check To check if the .NET Framework is installed, check if the following dword value is
present in the registry:
HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\NET Framework
Setup\ NDP\v4\Full\Release
If this value exists, check if it is equal or langer than the following numbers:
> On Windows 10: 394254
> On other operating systems: 394271
If that is the case, a sufficient version of the Microsoft .NET Framework is present. In
all other cases, you should install the Microsoft .NET Framework 4.6.1.
Note: The registry key
HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\NET Framework
Setup\ NDP\v4\Full\
does not exist at all if no .NET Framework of version 4.x is installed.
Installation To install the Microsoft .NET Framework 4.6.1 silently, use the following command:
NDP461-KB3102436-x86-x64-AllOS-ENU.exe /q /norestart
It is recommended to install either the German or the Japanese language pack
for .NET Framework 4.6.1 on German and Japanese systems, respectively. To install
it silently, use the following command:
> German: NDP461-KB3102436-x86-x64-AllOS-DEU.exe /q /norestart
> Japanese: NDP461-KB3102436-x86-x64-AllOS-JPN.exe /q /norestart
CANoe/CANalyzer Effective with CANoe/CANalyzer v8.0 and up you also have to have the Vector
v8.0 and up CANdela converters add-on installed. Note that this add-on may also be installed by
other Vector products.
Installation check To verify that the latest version of the Vector CANdela converters add-on is installed,
check the newest product of the product family with the following upgrade code:
{4071CAEA-9245-4195-AD8C-163E19A2DD63}
Install the Vector CANdela converters add-on if the installed version is less than
9.0.00100 or no version is installed.
Installation The Vector CANdela converters add-on is provided as a Windows Installer Package.
You can install it using the package CANdelaPersistors9.0.msi.
CANoe/CANalyzer When CANoe/CANalyzer Option AFDX is installed, you also have to install the Vector
Option AFDX, ICD Manager.
CANaero, A429
Installation check To verify that the latest version of the Vector ICD Manager is installed, check the
newest product of the product family with the following upgrade code:
{1E689111-0B79-4566-9750-94822F0EF6C5}
Install the Vector ICD Manager if the installed version is less than 2.1.50 or no version
is installed.
Installation The Vector ICD Manager is provided as a Windows Installer Package. You can install
it using the package SetupICD2DBC.msi.
CANoe/CANalyzer When CANoe/CANalyzer 8.0 SP2 or newer is installed, you should install the Vector
v8.0 SP2 and up License Manager.
Note that this tool may also be installed by other Vector products.
Installation check To verify that the latest version of the Vector License Manager is installed, check the
newest product of the product family with the following upgrade code:
{5745D1D3-BB4F-4AC8-9CB0-9D171DC6FD6B}
Install the Vector License Manager if the installed version is less than 1.4.100.0 or no
version is installed.
Installation The Vector License Manager is provided as a Windows Installer Package. You can
install it using the package VectorLicenseManagerInstaller.msi.
CANoe/CANalyzer When CANoe/CANalyzer starting with 8.5 SP3 is installed, you should install the 64
starting with v8.5 bit FlexNet licensing service.
SP3
Only 64 bit The 64 bit FlexNet licensing service is only required for the 64 bit version of
installation CANoe/CANalyzer when software based licenses are used.
Installation To install the 64 bit FlexNet licensing service, call installanchorservice with following
parameters:
installanchorservice.exe "Vector Informatik GmbH" "CANoe"
Note that FNP_Act_Installer.dll has to reside in the same directory as
installanchorservice.exe.
CANoe/CANalyzer When CANoe/CANalyzer 8.0 SP2 or newer is installed, you should install the Vector
v8.0 SP2 and up CANdelaStudio.
Note that this tool may also be installed by other Vector products.
Installation check To verify that the latest version of the Vector CANdelaStudio is installed, check the
newest product of the product family with the following upgrade code:
{A04D36FA-DC4E-4EDA-9630-519F2DB5BFB3}
Install the Vector CANdelaStudio 9.0 if the installed version is less than 9.0.0100 or
no version is installed.
Installation The Vector CANelaStudio is provided as a Windows Installer Package. You can
install it using the package CANdelaStudio9.0.msi.
Set the following properties during installation to prevent desktop shortcuts:
CANDELASTUDIO_ADDDESKTOPICON=0 REBOOTREQUIRED=0
CS_ADDDESKTOPICON_EN=0 CS_ADDDESKTOPICON_DE=0
CS_ADDDESKTOPICON_JA=0
CANoe/CANalyzer When CANoe/CANalyzer 8.0 SP2 or newer is installed, you should install the Vector
v8.0 SP2 and up ODXStudio.
Note that this tool may also be installed by other Vector products.
Installation check To verify that the latest version of the Vector ODXStudio is installed, check the
newest product of the product family with the following upgrade code:
{03FFD592-A6E8-43D9-A1E6-73A9ABD86825}
Install the Vector ODXStudio 4.1 P1 if the installed version is less than 4.1.101 or no
version is installed.
Installation The Vector ODXStudio is provided as a Windows Installer Package. You can install it
using the package ODXStudio4.1P1.msi.
CANoe/CANalyzer When CANoe/CANalyzer with option CAN, FlexRay or Ethernet is installed, you
Options CAN, should install the Vector AUTOSAR Explorer 1.7.
FlexRay, Ethernet
Note that this tool may also be installed by other Vector products.
Installation check To verify that the latest version of the Vector AUTOSAR Explorer 1.x is installed,
check the newest product of the product family with the following upgrade code:
{096EF4C5-6165-4FB2-9540-2FB1CDCD153C}
Installation The Vector AUTOSAR Explorer is provided as a Windows Installer Package. You can
install it using the package AUTOSARExplorer.msi.
Set the following property during installation to register the ARXML file type for
Vector AUTOSAR Explorer:
VREGISTER_FILE_EXT=1
CANoe/CANalyzer When CANoe/CANalyzer 64 bit with option CAN or FlexRay is installed, you should
Options CAN, install the Vector AUTOSAR Explorer 2.0 in addition to version 1.7.
FlexRay
Note that this tool may also be installed by other Vector products.
Only 64 bit This version of Vector AUTOSAR Explorer is only available for 64 bit operating
installation systems in combination with the 64 bit version of CANoe/CANalyzer.
Installation check To verify that the latest version of the Vector AUTOSAR Explorer 2.x is installed,
check the newest product of the product family with the following upgrade code:
{C53C0C39-CD73-4E20-A99D-371CC30A23A7}
Installation The Vector AUTOSAR Explorer is provided as a Windows Installer Package. You can
install it using the package AUTOSARExplorer2.msi.
CANoe/CANalyzer When CANoe/CANalyzer with option FlexRay is installed, you should install the
Option FlexRay Vector FIBEX Explorer.
Note that this tool may also be installed by other Vector products.
Installation check To verify that the latest version of the Vector FIBEX Explorer is installed, check the
newest product of the product family with the following upgrade code:
{1A240E4E-A1F2-4552-B430-770B01128C28}
Installation The Vector FIBEX Explorer is provided as a Windows Installer Package. You can
install it using the package FIBEXExplorer.msi.
Set the following property during installation to register the XML file type for Vector
FIBEX Explorer:
VREGISTER_FILE_EXT=1
Note that this setting is likely to conflict with other applications using the XML file type.
For that reason, it is recommended not to set VREGISTER_FILE_EXT.
CANoe/CANalyzer When CANoe/CANalyzer with option LIN is installed, you should install the Vector
Option LIN LDF Explorer.
Note that this tool may also be installed by other Vector products.
Installation check To verify that the latest version of the Vector LDF Explorer is installed, check the
newest product of the product family with the following upgrade code:
{5C652F7C-5EF5-411A-B611-345D5287BD5D}
Installation The Vector LDF Explorer is provided as a Windows Installer Package. You can install
it using the package LDFExplorer.msi.
Set the following property during installation to register the LDF file type for Vector
LDF Explorer:
VREGISTER_FILE_EXT=1
CANoe/CANalyzer When CANoe/CANalyzer with option AMD or XCP is installed, you should install the
Options AMD, XCP Vector ASAP2 Viewer.
Note that this tool may also be installed by other Vector products.
Installation check To verify that the latest version of the Vector ASAP2 Viewer is installed, check the
newest product of the product family with the following upgrade code:
{4C1089BC-DAFD-47D4-96BB-89C292B9D982}
Installation The Vector ASAP2Viewer is provided as a Windows Installer Package. You can
install it using the package ASAP2Viewer.msi.
Installation check To verify that the latest version of the Vector CANoe CANalyzer Scope is installed,
check the newest product of the product family with the following upgrade code:
{CDEA67B2-8AA8-45F9-BF9A-2777207935A6}
Installation The Vector CANoe CANalyzer Scope is provided as a Windows Installer Package.
You can install it using the package CANoeCANalyzerScope_x64.msi.
CANoe/CANalyzer When CANoe/CANalyzer Option AFDX, CANaero or A429 is installed, you also have
Option AFDX, to install the Vector Aerospace Message Editor.
CANaero, A429
Installation check To verify that the latest version of the Vector Aerospace Message Editor is installed,
check the newest product of the product family with the following upgrade code:
{2341551F-B4B2-4CED-9ABF-C7E31299BCC0}
Install the Vector Aerospace Message Editor if the installed version is less than
3.1.3012 or no version is installed.
Installation The Vector Aerospace Message Editor is provided as a Windows Installer Package.
You can install it using the package SetupVAME.msi.
CANoe/CANalyzer When CANoe/CANalyzer 10.0 or newer is installed, you should install the Vector
v10.0 and up Shell Extensions package to improve the handling of CANoe/CANalyzer compatible
log and support file formats in Windows Explorer.
32/64 bit installation On a 32 bit operating system, only the 32 bit Shell Extensions can be installed.
On a 64 bit operating system, you should install both the 32 bit and the 64 bit Shell
Extensions.
Installation check To verify that the latest version of the 32 bit Shell Extensions is installed, check the
newest 32 bit product of the product family with the following upgrade code:
{09D94F4D-1CBB-4868-9755-CC7091E3407F}
Install the 32 bit Shell Extensions if the installed version is less than 4.1.0.3570 or no
version is installed.
To verify that the latest version of the 64 bit Shell Extensions is installed, check the
newest 64 bit product of the product family with the upgrade code above.
Install the 64 bit Shell Extensions if the installed version is less than 4.1.0.3570 or no
version is installed.
Installation The Vector Shell Extenions are provided as Windows Installer Packages. You can
install them using the packages Vector ShellExtensions 32-bit.msi respectively.
Vector ShellExtensions 64-bit.msi.
CANoe/CANalyzer When CANoe/CANalyzer 9.0 SP4 or newer is installed on a 32 bit operating system,
v9.0 SP4 and up you should install the CodeMeterRuntime (x86).
Installation check To verify that the latest version of the CodeMeter Runtime (x86) is installed, check the
newest product of the product family with the following upgrade code:
{AEB0BEAE-B5C8-4574-8CBB-D9977A890081}
Install the CodeMeter Runtime (x86) if the installed version is less than 6.40.2396.500
or no version is installed.
Installation To install the CodeMeter Runtime (x86) silently, use the following command:
CodeMeterRuntime32Reduced.exe /ComponentArgs "*":"qn"
CANoe/CANalyzer When CANoe/CANalyzer 9.0 SP4 or newer is installed on a 64 bit operating system,
v9.0 SP4 and up you should install the CodeMeterRuntime (x64).
Installation check To verify that the latest version of the CodeMeter Runtime (x64) is installed, check the
newest product of the product family with the following upgrade code:
{DE93D016-7D56-4EE8-8579-EC47F02CCC5B}
Install the CodeMeter Runtime (x64) if the installed version is less than 6.40.2396.500
or no version is installed.
Installation To install the CodeMeter Runtime (x64) silently, use the following command:
CodeMeterRuntime64Reduced.exe /ComponentArgs "*":"qn"
CANoe/CANalyzer When CANoe/CANalyzer 10.0 or newer is installed, you should install Vector CANoe
v10.0 and up Test Report Viewer to be able to view CANoe Test Reports.
Note that this tool may also be installed individually by its separately available
Standalone Setup.
Installation check To verify if the Vector CANoe Test Report Viewer is installed, check the newest
product of the product family with the following upgrade code:
{95348EA2-2F5F-402C-987E-883538EAE7B9}
Installation The Vector CANoe Test Report Viewer is provided as a Windows Installer Package.
You can install it using the package CANoeTestReportViewer.msi.
CANoe/CANalyzer When CANoe/CANalyzer 10.0 or newer is installed, you should install Vector Suport
v10.0 and up Assistant to be able to send support reports to Vector Support Team.
Note that the Vector Support Assistant needs the Vector Shell Extensions to be
installed.
Installation check To verify if the Vector Support Assistant is installed, check the newest product of the
product family with the following upgrade code:
{8B5CE374-D2B2-4778-98E4-B7D9D450E85D}
Installation The Vector Support Assistant is provided as a Windows Installer Package. You can
install it using the package Vector Support Assistant.msi
CANoe/CANalyzer When CANoe/CANalyzer 10.0 or newer is installed, you may install Vector network
v10.0 and up driver to be able to use integrated network interface cards of the PC as interface
hardware for CANoe/CANalyzer.
Option Ethernet,
AFDX Note that you do not need this driver in order to use Vector VN5610, VN5610A or
VN5640.
Optional
Installation check To verify if the Vector network driver is installed, check the newest product of the
product family with the following upgrade code:
{7705A768-D398-4162-B619-8C8F14C769D9}
Installation The Vector network driver is provided as a Windows Installer Package. You can
install it using the package NetworkDriver.msi
CANoe/CANalyzer When CANoe/CANalyzer 10.0 SP3 or newer is installed, you should install Vector
v10.0 SP3 and up Security Manager.
Installation check To verify if the Vector Security Manager is installed, check the newest product of the
product family with the following upgrade code:
{94D964B0-9083-4BAD-9E9F-28961884CF8E}
Installation The Vector Security Manager is provided as a Windows Installer Package. You can
install it using the package VectorSecurityManager.msi
3 Settings
Properties for using The MSI setup was created to ease the deployment of CANoe/CANalyzer in large IT
software deployment networks via software deployment systems. To support this, the options that can be
systems changed in the user interface setup are represented by public properties. Note that
CANoe and CANalyzer are complex software utilities whose correct execution
depends on some settings you might want to change. Only change the settings
available through the properties described in the following table, otherwise, a correct
setup execution can not be guaranteed.
Public properties The following table lists the public properties and their meaning, as well as their
standard or predefined values respectively.
Note: In case one of the following public properties shall be set to a customized value,
the respective property and its value
> have to be either directly provided on the msiexec command line or
> have to be added and/or modified in the ‘Property’ table of the MST when using
your own transform files for deployment.
For an example please refer to chapter 4.1 Silent Installation Example.
Note: Property names are case sensitive!
Note: You MUST NOT change anything else than the public properties specified in
the table above.
Note: Starting with Windows Vista, installing the application and user data in the
system program folder (e.g. C:\Program Files) is not supported. If you install
CANoe/CANalyzer in the system program directory (e.g. C:\Program Files\Vector
CANoe 8.1), you must not set the value of the property
VAPPLICATION_AND_DATA_ROOT to 3.
Features The installation consists of following main features. All features except “Program” can
be (de)selected by the user:
> Program
> Demos
> Help
When performing a silent installation, specify the features to be installed with the
ADDLOCAL property See chapter 4.1 (Silent Installation Example) for an example on
using the ADDLOCAL property
For more information on the ADDLOCAL property, see http://msdn.microsoft.com/en-
us/library/aa367536%28v=vs.85%29.aspx.
Note: Note that additionally to the user's feature selection, a feature will only be
installed if the installation key contains the feature (e.g. CANoe will not be installed if
you licensed CANalyzer software.). Advertising is not supported for any of the
features included in the setup software.
3.3 Transforms
Selecting name of The MSI setup is able to install both Vector CANalyzer and Vector CANoe to the
product to be same machine. For this purpose, the MSI setup contains different embedded
installed transforms.
These embedded transforms must be executed in any case in order to set the
product name correctly. The selected name will be displayed in the Add/Remove
Programs dialog.
When installing, you need to specify the product you want to install:
> For Vector CANalyzer use:
CANalyzerTransform.mst
> For Vector CANoe use:
CANoeTransform.mst
Only the transforms mentioned above are supported. You can only use the transform
for the product for which you received license information (installation key).
Installing multiple The Vector CANoe/CANalyzer MSI setup does not enable you to install an arbitrary
instances of one number of instances of the same product on one computer. However, a limited set of
product product codes is mentioned in the Setup.ini file that comes with the installation
package. For each product code there is an entry in Setup.ini:
[InstanceId1]
InstanceId=1
ProductCode={F041B692-0ED2-41B7-8457-25E918271439}
Important Note:
Whenever you specify an instance ID to be used on installation, you also have to set
the value of the property MSINEWINSTANCE to 1 (e.g. MSINEWINSTANCE=1 on
command line), even if you install only one instance with a specific instance ID.
Otherwise you will encounter problems when updating the installetion to a later
service pack.
Those product codes can be used to install multiple versions of the product by using
them for instance transformation.
Every product code in Setup.ini can be used for either installing CANoe or installing
CANalyzer.
Be aware that you have to manage all subsequent operations on the product instance
yourself. E.g. when installing multiple instances of Vector CANoe you need to take
care to use the correct instance's product code when uninstalling one of them.
4 Further Installations
Silent Installation Installing CANoe and CANalyzer on the same machine silently
example:
Installation sequence: First CANoe (only program files), then CANalyzer (program
and sample configurations but no help)
Note for 64 bit: Please note that the name of the installation database is
CANoe_CANalyzer64.msi for the 64 bit installation package.
TRANSFORMS=:CANoeTransform.mst
Applies the embedded transform ‘CANoeTransform’ for setting the product name to
‘CANoe’. The “:” shows that the transform to be applied is embedded in the MSI.
VSETUPKEY_CUSTOMER=<customer>
VSETUPKEY_SERIALNUMBER=<serialnumber>
VSETUPKEY_LICENSEKEY=<licensekey>
Set the values for <customer>, <serial number> and <license key> and provided from
Vector for your ordered CANoe.
CANalyzer installation:
Since CANoe is already installed, a new instance has to be installed using an
instance transform.
msiexec /i CANoe_CANalyzer.msi
TRANSFORMS=:InstanceId1.mst;:CANalyzerTransform.mst
MSINEWINSTANCE=1 VSETUPKEY_CUSTOMER=<customer>
VSETUPKEY_SERIALNUMBER=<serialnumber>
VSETUPKEY_LICENSEKEY=<licensekey>
ADDLOCAL=Program,Demos /q
MSINEWINSTANCE=1
Specifies that a new instance will be installed. This property has to be set anytime an
instance id transform is applied.
TRANSFORMS=:InstanceId1.mst;:CANalyzerTransform.mst
Applies the embedded transforms ‘InstanceId1’ for installing a new instance and
‘CANalyzerTransform’ for setting the product name to ‘CANalyzer’. Choosing
‘InstanceId1.mst’ will set the product code for your CANalyzer installation as specified
in Setup.ini in the section [InstanceId1].
Note: All instance transforms (InstanceId1 … InstanceId100) are embedded
transforms, i.e. when selecting an instance transform set a “:” prior to the desired
transform.
VSETUPKEY_CUSTOMER=<customer>
VSETUPKEY_SERIALNUMBER=<serialnumber>
VSETUPKEY_LICENSEKEY=<licensekey>
Set the values for <customer>, <serialnumber> and <licensekey> and
provided from Vector for your ordered CANalyzer.
Creating an own For both examples above, the installation is executed on the command line setting
transform (.mst) for various public properties. In case an own transform (.mst) should be created to install
the command line: CANoe and/or CANalyzer you have to set the respective properties as shown for the
command line. Therefore create a transform for CANoe (e.g.
MyCANoeTransform.mst) and one for CANalyzer (e.g. MyCANalyzerTransform.mst)
and set the following properties in the Property table. In case the respective property
is not yet available in the ‘Property’ table, insert it and set the desired value.
Note: Property names are case sensitive!
Note: When installing CANoe or CANalyzer you also have to apply the embedded
transform ‘CANoeTransform.mst’ and ‘CANalyzerTransform.mst’ respectively beside
your own generated transform.
For this example the command line then has to be set as follows:
CANoe installation:
msiexec /i CANoe_CANalyzer.msi
TRANSFORMS=:CANoeTransform.mst;MyCANoeTransform.mst /q
CANalyzer installation:
msiexec /i CANoe_CANalyzer.msi
TRANSFORMS=:InstanceId1.mst;:CANalyzerTransform.mst;MyCANalyzerTransfor
m.mst MSINEWINSTANCE=1 /q
Of course, further properties can be set to customize the installation. Therefore you
can use the defined properties described in chapter 3.1.
Examples:
Setting the desired language to German:
VPROGRAM_LANGUAGE=49
Setting the installation directory:
INSTALLDIR=”C:\Programs\My Vector Folder\CANoe 8.1”
Note: The various software deployment tools might provide different methods to
enable the Windows Installer logging.
To enable Windows Installer logging on the command line you can use the parameter
/l with its various options, e.g. you can use /l*vx <log file path>
to enable a verbose logging.
4.2.1 Prerequisites
Prerequisites A service pack installation can only be executed if a CANoe/CANalyzer of the same
main version but lower SP level is already installed. Otherwise a full installation has to
be done.
The service pack installation is compressed as a self-extracting executable when
downloaded from the web. In case you want to run the installation interactively, just
start the executable. Otherwise (e.g. for silent installation or deployment) load the
executable in a ZIP utility (e.g. WinZip or 7-Zip) and extract the contents first.
Silent update For a silent update the following parameters have to be set at the command line:
msiexec /i CANoe_CANalyzer.msi REINSTALLMODE=vomus
REINSTALL=ALL IS_MINOR_UPGRADE=1 /q
In case multiple instances are installed on the machine you can specify the instance
to be updated by adding the parameter /n {Product-Code}.
Note: The parameter ( /n {Product-Code} ) must not be set, in case you want to
update a CANoe/CANalyzer installation which was installed using the base product
code. The base product code is defined in the file Setup.ini in the section [Startup].
Silent instalaltion/ When the CANoe/CANalyzer installation is deployed using a software deployment
software deployment system, it might be a requirement to map a unique product code to a concrete
installation in order to identify and maintain this installation. Due to the architecture of
the current installation package, this mapping does not happen automatically.
When it is required to use unique product codes to identify different
CANoe/CANalyzer installations (e.g. thex may differ in matter of service pack level),
you can use the following special product codes / product instance transforms.
You can then e,g, use :InstanceId101.mst .. :InstanceId110.mst for CANoe
(e.g. :InstanceId101.mst for main version, :InstanceId102.mst for service pack 2,
…) deployments and :InstanceId111.mst .. :InstanceId120.mst for CANalyzer
deployments.
Note that these special product code instances will not be used when the installation
is performed interactively (by starting setup.exe).
Name of embedded
Instance product code
transform
:InstanceId101.mst {01F4B746-9BF0-445E-AA34-E9C37F7286EC}
:InstanceId102.mst {F543984A-D1E6-4F47-8D56-EC85F49D419A}
:InstanceId103.mst {C01F9A5C-EBE0-4C3C-957C-E43EBFF492B2}
:InstanceId104.mst {A8A119E2-57A4-481C-A1C6-533B88B69986}
:InstanceId105.mst {20DD41B7-A258-44F7-AA93-C2000D48EA40}
:InstanceId106.mst {CABBFC72-66CC-461F-AB0A-52E739390D90}
:InstanceId107.mst {437977F5-3302-48CF-B5F0-737A530392DD}
:InstanceId108.mst {E1B3F3A5-3766-4DB9-9F41-BA5C8D76355D}
:InstanceId109.mst {855BC777-3614-41F7-923D-8784A67D3AAF}
:InstanceId110.mst {57E13DE9-A017-4CEF-9432-EA520B6FA0C4}
:InstanceId111.mst {1EEE23CB-6548-4F69-9A84-50A3A3D129E9}
:InstanceId112.mst {1A1BAF11-8646-472A-8379-C497DD83B7E7}
:InstanceId113.mst {8F470B09-3331-4895-8327-3FA543ED1C77}
:InstanceId114.mst {729C3EFA-73CE-4E7E-9032-D5AB2F7AC2B4}
:InstanceId115.mst {A8D8303F-760F-4833-8BC5-49A8137734B2}
:InstanceId116.mst {FF12B957-FC7C-4314-8210-FC36583F80B5}
:InstanceId117.mst {C68B8FEC-D643-46B2-BC40-991C9C097B11}
:InstanceId118.mst {2A5D75F9-0CA5-402D-804D-84930C5DC80D}
:InstanceId119.mst {2C1D290D-3D64-433C-8AEB-4A380167524D}
:InstanceId120.mst {45AF2349-8946-4252-BF26-77B138F947B1}
Name of embedded
Instance product code
transform
:InstanceId101.mst {77003DFC-20B7-4DB9-B7A6-1DF7A96CACDB}
:InstanceId102.mst {B07A2F26-E06B-4984-97BC-C24D64127CA7}
:InstanceId103.mst {48BB1A8E-D162-424B-AB4E-2BBC7AEB71ED}
:InstanceId104.mst {2C0E6DBD-8B8E-41F6-8092-A269CFD09451}
:InstanceId105.mst {3883D319-43C0-4A24-80D1-16107948FFCA}
:InstanceId106.mst {C5F9B6A5-3DE0-4159-BC2D-8C5991822D64}
:InstanceId107.mst {FC227B92-1128-46E9-A048-66199189CBC0}
:InstanceId108.mst {C755051D-E402-4D17-B5AB-40CAE7F4ECCF}
:InstanceId109.mst {D191AB57-D91D-4FDF-9AA0-3A4F7CEFE62C}
:InstanceId110.mst {EC46176C-B1BD-4694-B5F6-AC687BF55E21}
:InstanceId111.mst {94499298-2CBB-4975-983B-5DA25569030B}
:InstanceId112.mst {267BE623-D7D7-4EFB-A71C-BE3917370A67}
:InstanceId113.mst {4A458EE4-AA1C-4FCD-A6BB-74DF48BF57F0}
Name of embedded
Instance product code
transform
:InstanceId114.mst {84EDF1D1-C473-42B1-BEC8-D284C845CF38}
:InstanceId115.mst {4B73D3FB-0260-489A-A3AF-9AA3A1B3B437}
:InstanceId116.mst {4A6818A3-190A-477C-9DB4-3A4C8D10433E}
:InstanceId117.mst {B6BD52E8-4660-4982-8581-0C7F2842684C}
:InstanceId118.mst {C0FC8FBD-C2FF-4B69-BF02-B6EDEB07DE78}
:InstanceId119.mst {33345038-A0A8-4534-8869-BE7D20E9B26D}
:InstanceId120.mst {64646EFD-AA84-412D-9FF0-12F63B50CEE3}
Prevent installation When the installation is executed in interactive mode by running the bootstrapper
of prerequisite application (setup.exe), the installation of a prerequisite can be prevented. When an
installation package is deleted from the Redist directory, it will not be installed.
Note: You will delete prerequisites at your own risk. Important prerequisites for
CANoe/CANalyzer can be lost that may cause malfunction of CANoe/CANalyzer.
Installation The drivers for Vector network interfaces are not installed via the Windows Installer
setup. At the moment there are no Windows Installer installations available for Vector
hardware drivers. You have to ensure that the drivers for the used Vector hardware
are installed on the target machines.