You are on page 1of 1

LOAD REACTIVE, LOAD CONTROL VALVE

(Non-Vented)
Ordering Code: MB-17A-X-Y-Z
Turn screw clockwise Control Option:
to reduce setting and 4.0 Hex. Maximum extension
release load. from locating shoulder.
(Z=L Control shown)
14.0 Hex.
Torque 6 - 7 Nm 2 1
2 1
31.7 Hex.
(1-1/4 inch)

3 3

108 TECHNICAL DATA


Max. Setting: 350 bar
Rated flow: 240 l/min
Pilot 3 Cavity-Tooling: 17A-3
Locating
Shoulder
M36x2.0 Installation torque: 200 - 215 Nm
46.22 (Ref.)

Weight: 0.95 kg
Valve 2 Pressure Setting:
Setting should be 1.3 times maximum load
induced pressure.
(We suggest when the Max. setting pressure is 350 bar,
the load pressure has to be lower than 260 bar.)
Working Parts
9.4 Clearance This valve is functionally a 3 ports counterbalance valve
(CB). It seats as a poppet valve and modulates as
UNIT:mm Load 1 a spool valve.

X PILOT RATIO (with sealed pilot)


Pressure Differential vs Flow
25 3A 1.5 : 1
Pressure- P(bar)

20
Piloted Open 3C 3:1
15
3D 4.5 : 1
10 Free Flow
5 SPRINGS
Y ADJUSTMENT RANGES
0 40 80 120 160 200 240 (1.7 bar Cracking Pressure)
70 - 280 bar
Flow-Q(l/min) H (210 bar Standard Setting)
J 140 - 350 bar
(210 bar Standard Setting)
140 - 420 bar Max. Setting
Pressure Differential vs Flow *F (Requirement for Factory Setting
Pressure 350 - 420 bar)
500
I 25 - 105 bar
Pressure- P(bar)

400 (70 bar Standard Setting)


300

200
Z OPTIONS
100
L Leakproof hex.
0 40 80 120 160 200 240 socket screw.
Flow-Q(l/min)

Rev.220916 (MBGA)(MEGB)(MEGG) B.126.103.E