You are on page 1of 9

User's Manual

First, Product Layout

Front Panel Front Panel Rear Panel


Camera module

(optional)

Camera module
Display screen
(optional)
Password
button
Power/Setting
button (optional)
Doorbell and
lock button
Reset button
Switch button

Fingerprinting

Open handle

Automatic knob

Keyhole
Lock knob

Emergency

power Mounting
screws

Attention: Please keep the interior of the front


and rear panels clean during installation.
Structure of Automatic Intelligent Lock
Installation diagram of automatic intelligent
lock
Installer sketch:

Installation steps
1.Install the lock body, and then fix the lock body with four M5*6
screws.
2.Install the lock cylinder, fix the lock cylinder with the lock
cylinder fixing screw, ensure that the copper bar of the lock
cylinder rotating shaft faces the room, and the length is 18 ~
20mm of the exposed door plane (as shown in Fig. 2, the lock
cylinder must be installed and then the copper bar should be cut)
3.Install the front panel.
4.Install the bottom plate (with rubber pad), and fix the two studs
of the front panel with M5 screws.
5.Connect the front and rear panel data lines, and then install the
rear panel on the hole position, and fix it with four M4 screws
6.Install the lithium battery, cover the battery cover, and complete
the installation steps. Fig.2
Second, Product Introduction
1.Door opening method:Fingerprint, password, IC card, mechanical key, We-chat applet
and many other ways to open the door. Bring you a different experience. (The specific
configuration is subject to the actual product)
2.Fingerprint: Using advanced semiconductor sensor, 360-degree recognition angle, wide
fingerprint collection area, high resolution, effectively preventing fake fingerprints.
3.Password: Adopting fashionable and advanced touch-screen button technology, which can
add 12 irrelevant passwords before and after the correct password, effectively preventing
the embarrassment of entering the password when multiple people are walking together.
4.Two-factor authentication: password, fingerprint, and card can be set to verify and unlock
in pairs. After setting, only two users should verify at the same time to open the door,
suitable for special occasions.
5.User Management: The administrator has the highest authority (ordinary users can only
open and close the door), can set the lock, the number of administrators is 9 (can be
password, fingerprint, card), the total capacity is 300.
6.Alarm function: The machine has anti-pick-lock alarm, low pressure alarm, trial and error
alarm.
7.Backup power supply: When the battery is exhausted, 5V mobile power can be used to
provide emergency power to the door lock.

Third,Matters need attention


1.After the new lock is installed, it is necessary to restore the initialization operation and
clear the fingerprint entered during installation and debugging.
2.Handle is the key part of door opening and closing, and its flexibility directly affects
the use of door lock. Therefore, do not hang objects on the handle.
3.When collecting fingerprints, the strength of fingers should be moderate. Do not press
vigorously to prevent scratches on the fingerprint collecting head.
4.The battery should not be used for too long. It is generally recommended to charge the
battery at least once every 3 months, otherwise the battery will leak and damage the smart
lock.
5.This lock uses 8.4v high-performance lithium battery. When it is prompted that "the
power is insufficient, please replace the battery" for the first time, it can open the door
about 100 times according to different battery capacity. At this time, it should be charged
in time to avoid inconvenience caused by battery depletion.
6.If the input error of unlocking in any way is 5 times, the alarm will sound, and the door
lock will not be used within 90s.
Fourth,User Guide
 Initialization
Use the card needle, press the small hole in the middle of the unlock / close button
on the back panel for 5 seconds, and the voice prompts "initialization succeeded". The
factory project password "123456" can be to open the door. After entering the
administrator information, the project password "123456" will be automatically deleted.
mima

an

 Access door lock function management(No networking mode)


In the initialization state, wake up
 the screen by pressing "+ #"

Add administrator
It can be fingerprint, password, IC card.
Under the normal
conditions,
”*”Back / Exit / Delete
After adding, you can enter the
“#”Confirm key / Input
door lock function
key / Repeat voice
management.
broadcast

After the operation is successful, press "*"


to return to the previous level or continue
to add an administrator.

 Add users, delete users


In the initialization state, wake up
Under the normal the screen by pressing "+ #"
conditions,
”*”Back / Exit / Delete
“#”Confirm key / Input
key / Repeat voice After adding an administrator, you need
broadcast to verify the administrator every time
you enter the function management.

Press "1" to add user Press "2" to delete user information.


information, you can input
fingerprint, password or card.
Enter the fingerprint, password, card
or number of the user to be deleted.
After the operation is successful,
press "*" to return to the previous
level or continue to add ordinary After the operation is successful,
users. press "*" to return to the previous
level or continue to delete users.
 Door lock setting

Under the normal


conditions, Wake up the screen by
”*”Back / Exit / Delete pressing "+ #"
“#”Confirm key / Input
key / Repeat voice
broadcast
After adding an administrator, you need
to verify the administrator every time
you enter the function management.

Press "3" to enter the door lock setting.

Press "1" to enter Press "2" to Press "3" to enter Press "4" to enter
the function setting adjust the volume voice settings the time setting

1. Turn on dual
verification 2. Turn 1.Volume up 1. Use Chinese
2.Volume prompt 2. Use Set time
off the anti prying
alarm. 3. Turn on reduction English prompt
mute mode.

According to the actual use needs, select the Press "year, month, day,
hour, minute" to set the
corresponding number key to complete the setting time, press "*" to delete,
and press "#" to confirm

After the operation is successful,


press "*" to return to the previous
level or proceed with
something else.
 Add administrator
In the initialization state, wake
Under the normal up the screen by pressing "+ #"
conditions,
”*”Back / Exit / Delete
“#”Confirm key / Input
key / Repeat voice After adding an administrator, you need
broadcast to verify the administrator every time
you enter the function management.

Press "4" to add administrator, you can


input fingerprint, password or card

After the operation is successful, press


"*" to return to the previous level or
continue to add administrators.

 Access door lock function management (with networking


module) optional

Under the normal


conditions, In the initialization state, wake
”*”Back / Exit / Delete up the screen by pressing "+ #"
“#”Confirm key / Input
key / Repeat voice
broadcast After adding an administrator, you need to verify
the administrator every time you enter the
function management.

Press "1" to set up the wireless Press "2" to set the door lock function
network

1. Add device (network The content of this setting is consistent


connection).2.Delete the with that of non internet content. Please
device (disconnect the refer to the previous section for relevant
network) settings
 Maintenance menu

★ Maintenance menu is for installation and debugging


personnel to use, please operate carefully ★
Press "888#" or "99988777#" in factory status

Oblique tongue
Motor direction Lock in place
time

Positive direction The latch time is Open the lock in place


negative direction selected according Close the lock in place
to 1-9

 Restore the factory setting

Long press the key in the hole


for 5 seconds
 Other instructions

▲ If you input the wrong password for more than 5 times in five
minutes, the keyboard will be locked for 90 seconds. The system
will not respond to any operation within 90 seconds. You can enter
the administrator page through the setting key to release it.

▲ Password anti peeping function: when the password is opened,


input the password as follows: XXX password XXX, which can add
some irrelevant codes before and after the password, and then press
"#" to confirm. The password must be included in the input content.

▲ Every time more than 12 seconds no operating system will


automatically exit.

▲When the voltage is lower than 6.9v, the automatic alarm will be
given every time you unlock the door. The rear door lock can be
unlocked for 200 times. If the voltage exceeds 6.9v, it is forbidden to
unlock the door. Please replace the battery before the unlocking
times are reached.
Use we-chat scan to open the we chat
applet for unlocking.(It can only be used
after setting fingerprint lock time and
administrator's digital password)

Automatic lock installation video Visual peephole networking tutorial