Designation: E21 − 20

Standard Test Methods for


Elevated Temperature Tension Tests of Metallic Materials1
This standard is issued under the fixed designation E21; the number immediately following the designation indicates the year of original
adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.

1. Scope* E29 Practice for Using Significant Digits in Test Data to


1.1 These test methods cover procedure and equipment for Determine Conformance with Specifications
the determination of tensile strength, yield strength, elongation, E74 Practices for Calibration and Verification for Force-
and reduction of area of metallic materials at elevated tempera- Measuring Instruments
tures. E83 Practice for Verification and Classification of Exten-
someter Systems
1.2 Determination of modulus of elasticity and proportional E177 Practice for Use of the Terms Precision and Bias in
limit are not included. ASTM Test Methods
1.3 Tension tests under conditions of rapid heating or rapid E220 Test Method for Calibration of Thermocouples By
strain rates are not included. Comparison Techniques
1.4 The values stated in inch-pound units are to be regarded E633 Guide for Use of Thermocouples in Creep and Stress-
as standard. The values given in parentheses are mathematical Rupture Testing to 1800°F (1000°C) in Air
conversions to SI units that are provided for information only E691 Practice for Conducting an Interlaboratory Study to
and are not considered standard. Determine the Precision of a Test Method
1.5 This standard does not purport to address all of the 3. Terminology
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro- 3.1 Definitions of terms relating to tension testing which
priate safety, health, and environmental practices and deter- appear in Terminology E6, apply to this test method. These
mine the applicability of regulatory limitations prior to use. terms include alignment, axial strain, bending strain, gauge
1.6 This international standard was developed in accor- length, elongation, elongation after fracture, extensometer
dance with internationally recognized principles on standard- system, necking, reduction of area, tensile strength, yield
ization established in the Decision on Principles for the strength. In addition, the definitions of the following terms
Development of International Standards, Guides and Recom- relating to tension testing are included.
mendations issued by the World Trade Organization Technical 3.1.1 Definitions of terms relating to tension testing which
Barriers to Trade (TBT) Committee. appear in E6, shall apply to the terms used in this test method.
3.2 Definitions:
2. Referenced Documents
3.2.1 indicated temperature, n—the temperature indicated
2.1 ASTM Standards:2 by the temperature-measuring system that meets the require-
E4 Practices for Force Verification of Testing Machines ments of this standard.
E6 Terminology Relating to Methods of Mechanical Testing
3.2.2 specified temperature—the test temperature requested
E8/E8M Test Methods for Tension Testing of Metallic Ma-
by and reported to the customer.
terials
3.2.3 temperature-measuring system, n—a system consist-
ing of one or more temperature-measuring transducers with the
1
These test methods are under the jurisdiction of ASTM Committee E28 on appropriate indicating instruments, extension wires, reference
Mechanical Testing and are the direct responsibility of Subcommittee E28.04 on junctions or ice points, and data acquisition devices.
Uniaxial Testing.
Current edition approved Sept. 1, 2020. Published October 2020. Originally
3.2.3.1 Discussion— The temperature-measuring transducer
approved in 1933. Last previous edition approved in 2017 as E21 – 17ɛ1. DOI: is usually a thermocouple.
10.1520/E0021-20.
2
3.2.3.2 Discussion—The use of the term measuring system
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
conforms to the definition of "measuring system” in the JCGM:
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on International Vocabulary of Metrology – Basic and General
the ASTM website. Concepts and Associated terms (VIM).

*A Summary of Changes section appears at the end of this standard


Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
Copyright by ASTM Int'l (all rights reserved); Tue Apr 13 04:54:24 EDT 2021
1
Downloaded/printed by
University Of Birmingham (University Of Birmingham) pursuant to License Agreement. No further reproductions authorized.
E21 − 20
4. Significance and Use rods, and grips used in elevated temperature testing. The
4.1 The elevated-temperature tension test gives a useful specimen form should be the same as that used during the
estimate of the ability of metals to withstand the application of elevated-temperature tests and designed so that only elastic
applied tensile forces. Using established and conventional strains occur throughout the reduced section. This requirement
relationships it can be used to give some indication of probable may necessitate use of a material different from that used
behavior under other simple states of stress, such as during the elevated-temperature test. See Practice E1012 for
compression, shear, etc. The ductility values give a compara- recommended methods for determining specimen alignment.
tive measure of the capacity of different materials to deform 5.1.2.3 Gripping devices and pull rods may oxidize, warp,
locally without cracking and thus to accommodate a local and creep with repeated use at elevated temperatures. Increased
stress concentration or overstress; however, quantitative rela- bending stresses may result. Therefore, grips and pull rods
tionships between tensile ductility and the effect of stress should be periodically retested for axiality and reworked when
concentrations at elevated temperature are not universally necessary.
valid. A similar comparative relationship exists between tensile 5.1.3 The testing machine shall be equipped with a means of
ductility and strain-controlled, low-cycle fatigue life under measuring and controlling either the strain rate or the rate of
simple states of stress. The results of these tension tests can be crosshead motion or both to meet the requirements in 9.6.
considered as only a questionable comparative measure of the 5.1.4 For elevated-temperature testing of materials that are
strength and ductility for service times of many hours. readily attacked by their environment (such as oxidation of
Therefore, the principal usefulness of the elevated-temperature metal in air), the specimen may be enclosed in a capsule so that
tension test is to assure that the tested material is similar to it can be tested in a vacuum or inert gas atmosphere. When
reference material when other measures such as chemical such equipment is used, the necessary corrections must be
composition and microstructure also show the two materials made to determine the actual forces seen by the specimen. For
are similar. instance, compensation must be made for differences in pres-
sures inside and outside of the capsule and for any variation in
5. Apparatus the forces applied to the specimen due to sealing ring friction,
5.1 Testing Machine: bellows or other features.
5.1.1 The accuracy of the testing machine shall be within 5.2 Heating Apparatus:
the permissible variation specified in Practices E4. 5.2.1 The apparatus for and method of heating the speci-
5.1.2 Precaution should be taken to assure that the force on mens should provide the temperature control necessary to
the specimens is applied as axially as possible. Perfect axial satisfy the requirements specified in 9.4.
alignment is difficult to obtain especially when the pull rods 5.2.2 Heating shall be by an electric resistance or radiation
and extensometer rods pass through packing at the ends of the furnace with the specimen in air at atmospheric pressure unless
furnace. However, the machine and grips should be capable of other media are specifically agreed upon in advance.
loading a precisely made specimen so that the maximum
bending strain does not exceed 10 % of the axial strain, when NOTE 2—The media in which the specimens are tested may have a
the calculations are based on strain readings taken at zero force considerable effect on the results of tests. This is particularly true when the
properties are influenced by oxidation or corrosion during the test.
and at the lowest force for which the machine is being
qualified. 5.3 Temperature-measuring system:
5.3.1 The method of temperature measurement must be
NOTE 1—This requirement is intended to limit the maximum contribu-
tion of the testing apparatus to the bending which occurs during a test. It sufficiently sensitive and reliable to ensure that the indicated
is recognized that even with qualified apparatus different tests may have temperature of the specimen is within the limits specified in
quite different percent bending strain due to chance orientation of a 9.4.4.
loosely fitted specimen, lack of symmetry of that particular specimen, 5.3.2 Temperature should be measured with thermocouples
lateral force from furnace packing, and thermocouple wire, etc. The scant
evidence available at this time3 indicates that the effect of bending strain
as part of an appropriate temperature measuring system.
on test results is not sufficient, except in special cases, to require the NOTE 3—Such measurements are subject to two types of error.
measurement of this quantity on each specimen tested. Thermocouple calibration and instrument measuring errors initially intro-
5.1.2.1 In testing of brittle material even a bending strain of duce uncertainty as to the exact temperature. Secondly both thermo-
10 % may result in lower strength than would be obtained with couples and measuring instruments may be subject to variation with time.
Common errors encountered in the use of thermocouples to measure
improved axiality. In these cases, measurements of bending temperatures include: calibration error, drift in calibration due to contami-
strain on the specimen to be tested may be specifically nation or deterioration with use, lead-wire error, error arising from method
requested and the permissible magnitude limited to a smaller of attachment to the specimen, direct radiation of heat to the bead,
value. heat-conduction along thermocouple wires, etc.
5.1.2.2 In general, equipment is not available for determin- 5.3.3 If temperature measurements are made using
ing maximum bending strain at elevated temperatures. The thermocouples, those thermocouples shall be calibrated using
testing apparatus may be qualified by measurements of axiality Practice E220. Representative thermocouples should be cali-
made at room temperature using the assembled machine, pull brated from each lot of wires used for making base-metal
thermocouples. Except for relatively low temperatures of
3
Subcommittee E28.10 on Effect of Elevated Temperature on Properties requests exposure, base-metal thermocouples are subject to error upon
factual information on the effect of nonaxiality of loading on test results. reuse, unless the depth of immersion and temperature gradients

Copyright by ASTM Int'l (all rights reserved); Tue Apr 13 04:54:24 EDT 2021
2
Downloaded/printed by
University Of Birmingham (University Of Birmingham) pursuant to License Agreement. No further reproductions authorized.
E21 − 20
of the initial exposure are reproduced. Consequently base- 5.4.4 To attach the extensometer to miniature specimens
metal thermocouples should be verified by the use of repre- may be impractical. In this case, separation of the specimen
sentative thermocouples and actual thermocouples used to holders or crossheads may be recorded and used to determine
measure specimen temperatures should not be verified at strains corresponding to the 0.2 % offset yield strength. The
elevated temperatures. Base-metal thermocouples also shall value so obtained is of inferior accuracy and must be clearly
not be reused without clipping back to remove wire exposed to marked as “approximate yield strength.” The observed exten-
the hot zone and rewelding or creating a new compression sion should be adjusted by the procedure described in 9.6.3 and
junction. 10.1.3.
5.3.3.1 Noble metal thermocouples are also subject to errors 5.4.5 The extensometer system shall include a means of
due to contamination, etc., and should be periodically annealed determining strain rate.
and verified. Thermocouples should be kept clean prior to 5.5 Room-Temperature Control—Unless the extensometer is
exposure and during use at elevated temperatures. known to be insensitive to ambient temperature changes, the
5.3.3.2 Measurement of the emf drift in thermocouples range of ambient temperature should not exceed 10 °F (6 °C)
during use is difficult. When drift is a problem during tests, a while the extensometer is attached. The testing machine should
method should be devised to check the readings of the not be exposed to perceptibly varying drafts.
thermocouples on the specimen during the test. For reliable
calibration of thermocouples after use the temperature gradient 6. Sampling
of the testing furnace must be reproduced during the recalibra-
6.1 Unless otherwise specified the following sampling pro-
tion.
cedures shall be followed:
5.3.4 The temperature-measuring system, shall be verified
6.1.1 Samples of the material to provide test specimens
yearly against a secondary standard, such as a precision
shall be taken from such locations as to be representative of the
potentiometer and if necessary re-calibrated. Extension-wire
lot from which it was taken.
error should be checked with the extension wires in place as
6.1.2 Samples shall be taken from material in the final
they normally are used.
condition (temper). One test shall be made on each lot.
5.4 Extensometer System: 6.1.3 A lot shall consist of all material from the same heat,
5.4.1 Practice E83, is recommended as a guide for selecting nominal size, and condition (temper).
the required sensitivity and accuracy of extensometers. For
determination of offset yield strength at 0.1 % or greater, a 7. Test Specimens and Sample
Class B-2 extensometer may be used. The extensometer should 7.1 The size and shape of the test specimens should be
meet the requirements of Practice E83 and should, in addition, based primarily on the requirements necessary to obtain
be tested to assure its accuracy when used in conjunction with representative samples of the material being investigated.
a furnace at elevated temperature. One such test is to measure
at elevated temperature the stress and strain in the elastic range 7.2 Unless otherwise specified, test specimens shall be
of a metal of known modulus of elasticity. Combinations of oriented such that the axis of the specimen is parallel to the
stress and temperature which will result in creep of the direction of fabrication, and located as follows:
specimen during the extensometer system evaluation should be 7.2.1 At the center for products 1.5 in. (38 mm) or less in
avoided. thickness, diameter, or distance between flats.
7.2.2 Midway from the center to the surface for products
NOTE 4—If an extensometer of Class B-2 or better is attached to the over 1.5 in. (38 mm) in thickness, diameter, or distance
reduced section, the slope of the stress-strain curve will usually be within between flats.
10 % of the modulus of elasticity.
5.4.2 Non-axiality of loading is usually sufficient to cause 7.3 Specimen configurations described in Test Methods
significant errors at small strains when strain is measured on E8/E8M, are generally suitable for tests at elevated tempera-
only one side of the specimen.4 Therefore, the extensometer tures; however, tighter dimensional tolerances are recom-
should be attached to and indicate strain on opposite sides of mended in 7.6. The particular specimen used should be mainly
the specimen. The reported strain should be the average of the governed by the requirements specified in 7.1. When the
strains on the two sides, either a mechanical or electrical dimensions of the material permit, except for sheet and strip,
average internal to the instrument or a numerical average of the gauge length of the specimens should have a circular cross
two separate readings. section. The largest diameter specimen consistent with that
5.4.3 When feasible the extensometer should be attached described in 7.1 should be used, except that the diameter need
directly to the reduced section. When necessary, other arrange- not be greater than 0.500 in. (12.7 mm). The ratio of gauge
ments (discussed in 9.6.3) may be used by prior agreement of length to diameter should be 4, as for the standard specimens
the parties concerned. For example, special arrangements may described in Test Methods E8/E8M. If different ratios are used,
be necessary in testing brittle materials where failure is apt to the specifics should be reported in the results. (See 11.1.4)
be initiated at an extensometer knife edge. NOTE 5—Specimen size in itself has little effect on tensile properties
provided the material is not subject to appreciable surface corrosion, lack
of soundness, or orientation effects. A small number of grains in the
4
Tishler, D. N., and Wells, C. H., “An Improved High-Temperature Extensom- specimen cross section, or preferred orientation of grains due to fabrica-
eter ,” Materials Research and Standards , American Society for Testing and tion conditions, can have a pronounced effect on the test results. When
Materials, MTRSA, Vol 6, No. 1, January 1966, pp. 20–22. corrosion is a factor in testing, the results do become a function of

Copyright by ASTM Int'l (all rights reserved); Tue Apr 13 04:54:24 EDT 2021
3
Downloaded/printed by
University Of Birmingham (University Of Birmingham) pursuant to License Agreement. No further reproductions authorized.
E21 − 20
specimen size. Likewise, surface preparation of specimens, if affecting stresses or other undesired effects and should be minimized.
results, becomes more important as the specimen size is reduced. The axis of the reduced section should be straight within
7.4 Specimens of circular cross section should have 60.5 % of the diameter. Threads of the specimen should be
threaded, shouldered, or other suitable ends for gripping which concentric with this axis within the same tolerance. Other
will meet the requirements of 5.1.2. means of gripping should have comparable tolerances.
NOTE 6—Satisfactory axial alignment may be obtained with precisely 7.7 For cast-to-size specimens it may not be possible to
machined threaded ends. But at temperatures where oxidation and creep
are readily apparent, precisely fitted threads are difficult to maintain and to adhere to the diameter, straightness, and concentricity limita-
separate after test. Practical considerations require the use of relatively tions of 7.6, but every effort should be made to approach these
loose-fitting threads. Other gripping methods have been successfully as closely as possible. If the specimen does not meet the
used.5,6 requirements specified in 7.6, the report should so state (see
7.5 For rectangular specimens some modifications of the 11.1.4 and 11.1.10). The magnitude of the deviations should be
standard specimens described in Test Methods E8/E8M are reported (see 11.1.10.)
usually necessary to permit application of the force to the
specimen in the furnace with the axiality specified in 5.1.2. If 8. Calibration and Standardization
the material available is sufficient, the use of elongated
shoulder ends to permit gripping outside the furnace is the 8.1 The following devices should be calibrated against
easiest method. When the length of the specimen is necessarily standards traced to the National Institute of Standards and
restricted, several methods of gripping may be used as follows: Technology. Applicable ASTM methods are listed beside the
7.5.1 A device that applies the force through a cylindrical device.
pin in each of the enlarged ends of the specimen. The pin holes Force-measuring system E4 and E74
should be accurately centered on extensions of the centerline of Extensometer E83
ThermocouplesA E220
the gauge section. Grips of this type can provide good axiality Potentiometers
of loading.5 Micrometers
7.5.2 High-temperature sheet grips similar to those illus-
trated in Test Methods E8/E8M and described as self-adjusting A
Melting point methods are also recommended for thermocouple calibration.
grips. These have proven satisfactory for testing sheet materi-
als that cannot be tested satisfactorily in the usual type of 8.1.1 Axiality of the loading apparatus should be measured
wedge grips. as described in 5.1.2.
7.5.3 Extension tabs may be welded or brazed to the 8.2 Calibrations should be as frequent as is necessary to
specimen shoulders and extended to grips outside the furnace. assure that the errors in all tests do not exceed the permissible
When these are used, care must be exercised to maintain variations listed in this test method. The maximum period
coaxiality of the centerlines of the extensions and the gauge between calibrations of the testing machine shall be one year.
length. Any brazing or welding should be done in a jig or Instruments in either constant or nearly constant use should be
fixture to maintain accurate alignment of the parts. Any calibrated more frequently; those used only occasionally
machining should be done after brazing or welding.
should be calibrated before each use.
7.5.4 Grips that conform to and apply force against the
fillets at the ends of the reduced section.
9. Procedure
7.6 The diameter (or width) at the ends of the reduced
section should not be less than the diameter (or width) at the 9.1 Measurement of Cross-Sectional Area—Determine the
center of the reduced section. It may be desirable to have the minimum cross-sectional area of the reduced section as speci-
diameter (or width) of the reduced section slightly smaller at fied in 7.2 of Test Methods E8/E8M. In addition measure the
the center than at the ends. This difference should not exceed largest diameter (or width) in the reduced section and compare
0.5 % of the diameter (or width). When specimens of this form with the minimum value to determine whether the require-
are used to test brittle materials, failure may regularly occur at ments of 7.6 are satisfied.
the fillets. In these cases, the center of the reduced section may
9.2 Measurement of Original Length:
be made smaller by a gradual taper from the ends and the
exception to the requirements above noted in the report. (See 9.2.1 Unless otherwise specified, base all values for elon-
11.1.4 and 11.1.10.) Specimen surfaces shall be smooth and gation on a gauge length equal to four diameters in the case of
free from undercuts and scratches. Cold work introduced round specimens and four times the width in the case of
through machining or handling can produce high residual rectangular specimens, the gauge length being punched or
scribed on the reduced section.

5
NOTE 7—Elongation values of specimens with rectangular cross sec-
Schmieder, A. K.,“ Measuring the Apparatus Contributions to Bending in
tions cannot be compared unless all dimensions including the thickness
Tension Specimens ,” Elevated Temperature Testing Problem Areas, ASTM STP
488, American Society for Testing and Materials, 1971, pp. 15–42 are equal. Therefore, an elongation specification should include the
6
Penny, R. K., Ellison, E. G., and Webster, G. A.,“Specimen Alignment and specimen cross-sectional dimensions as well as the gauge length. Using a
Strain Measurement in Axial Creep Tests,” Materials Research and Standards, gauge length equal to 4.5 times the square root of the cross-sectional area
American Society for Testing and Materials, MTRSA, Vol 6, No. 2, February 1966, compensates somewhat for variations in specimen thickness but even this
pp. 76–84. does not result in the same value of elongation when specimens of the

Copyright by ASTM Int'l (all rights reserved); Tue Apr 13 04:54:24 EDT 2021
4
Downloaded/printed by
University Of Birmingham (University Of Birmingham) pursuant to License Agreement. No further reproductions authorized.
E21 − 20
same material are machined to different thicknesses and tested.7 the hot zone, it should be determined that the electrical
9.2.2 When testing metals of limited ductility gauge marks insulating properties are maintained at higher temperatures.
punched or scribed on the reduced section may be undesirable 9.4.3 When the length of the reduced section is less than 2
because fracture may occur at the stress concentrations so in. (50 mm), attach at least two thermocouples to the specimen,
caused. Then, place gauge marks on the shoulders or measure one near each end of the reduced section. For reduced sections
the over-all length of the specimen. Also measure the adjusted greater-than or equal to 2.0 in. (50 mm) add a third thermo-
length of the reduced section to the nearest 0.01 in. (0.2 mm) couple near the center of the reduced section.
as described in 9.2.3. If a gauge length, other than that specified 9.4.4 For the portion of the test from the first application of
in 9.2.1 is employed to measure elongation, describe the gauge force through the yield strength determination, the difference
length in the records (see 11.2.1). In the case of acceptance between the indicated temperature from any thermocouple and
tests, any deviation from 9.2.1 must be agreed upon before the specified temperature shall not exceed the following limits
testing. (see 11.1.5).
Specified temperatures up to and including 1800 °F ±5 °F (±3 °C)
NOTE 8—The availability of flexible ceramic fiber cords for mounting (980 °C)
of high temperature extensometers with high purity ceramic rods with Specified temperatures greater than 1800 °F (980 °C) ±10 °F (±6 °C)
chisel or vee-chisel ends, provides a good measure of ductility without
excessive damage to the gauge section caused by other types of exten- 9.4.4.1 The temperature limits of 9.4.4 should be main-
someters or traditional punch or scribe marks. Damage to the rods from tained as long as practical after the determination of yield.
specimen failure may be minimized through the use of spring loaded After yield strength determination, the difference between the
attachment fixtures. Non contact extensometers may also be used for this indicated temperature and the specified temperature may ex-
purpose.
ceed the limits specified in 9.4.4. The indicated temperature at
9.2.3 When the extensometer is to be attached to the the maximum deviation and the reason for the deviation shall
specimen shoulders, measure the adjusted length of the re- be reported. More restrictive requirements may be placed on
duced section between points on the two fillets where the the temperature control during the test if agreed to by the
diameter (or width) is 1.05 times the diameter (or width) of the laboratory and the customer.
reduced section. The strain rate and offset yield calculations are
based on this dimension (see 9.6.3, 10.1.2, and 10.3). NOTE 10—Deformation of the test specimen can change the indicated
temperature for many reasons that are difficult for the laboratory to
NOTE 9—In the yield region, stress is approximately proportional to control. Internal (adiabatic) heating due to plastic working can raise the
offset strain to a power which usually lies in the range from zero to 0.20. temperature of the test specimen. Elongation of the test specimen, for
For specimens of circular cross section the above value of adjusted length example from necking, can carry the thermocouples outside the hot zone
of the reduced section was found by calculation to give an error in yield of the furnace. Reduction of the diameter of the test specimen due to
stress of less than 1⁄2 % within this range of exponents and for fillet radii plastic deformation can cause thermocouples to lose intimate contact with
ranging from 0.5 to 1 times the diameter of the reduced section. The the test specimen.
method of calculation was similar to that used by Thomas and Carlson.8
9.4.5 The term “indicated temperature” means the tempera-
9.3 Cleaning Specimen—Wash carefully the reduced section ture that is indicated by the temperature measuring device
and those parts of the specimen which contact the grips in clean using good quality pyrometric practice.
alcohol, acetone, or other suitable solvent that will not affect
NOTE 11—It is recognized that true temperature may vary more than the
the metal being tested.
indicated temperature. The permissible indicated temperature variations in
9.4 Temperature Control: 9.4.4 are not to be construed as minimizing the importance of good
9.4.1 Form the thermocouple measuring junction in accor- pyrometric practice and precise temperature control. All laboratories
should keep both indicated and true temperature variations as small as
dance with Guide E633. practicable. It is well recognized, in view of the extreme dependency of
9.4.2 In attaching thermocouples to a specimen, the mea- strength of materials on temperature, that close temperature control is
suring junction shall be kept in intimate contact with the necessary. The limits prescribed represent ranges which are common
specimen and shielded from radiation. Shielding may be practice.
omitted if, for a particular furnace and specified temperature, 9.4.6 Indicated temperature overshoots during heating shall
the difference in indicated temperature from an unshielded not exceed the above limits, unless agreed upon by the
measuring junction and a measuring junction inserted in a hole customer and the supplier. The heating characteristics of the
in the specimen has been shown to be less than one half the furnace and the temperature control system should be studied
variation listed in 9.4.4. The measuring junction should be as to determine the power input, temperature set point, propor-
small as possible and there should be no shorting of the circuit tioning control adjustment, and control-thermocouple place-
(such as could occur from twisted wires behind the measuring ment necessary to limit transient temperature overshoots. It
junction but not in intimate contact with the specimen). may be desirable to stabilize the furnace at an indicated
Ceramic insulators should be used on the thermocouples in the temperature from 10 to 50 °F (6 to 28 °C) below the specified
hot zone. If some other electrical insulation material is used in temperature before making the final adjustments. The magni-
tude and duration of all temperature overshoots shall be
reported. (See 11.1.5.)
7
Stickley, G. W., and Brownhill, D. J., “Elongation and Yield Strength of 9.4.7 The time of holding at indicated temperature prior to
Aluminum Alloys as Related to Gage Length and Offset,” Proceedings, American
the start of the test should be governed by the time necessary
Society for Testing and Materials, ASTEA, Vol 65, 1965, pp 597–616.
8
Thomas, J. M., and Carlson, J. F., “Errors in Deformation Measurements for to ensure that the specimen has reached equilibrium and that
Elevated Temperature Tension Tests,” ASTM Bulletin, ASTM, May 1955, pp. 47–51. the indicated temperature can be maintained within the limits

Copyright by ASTM Int'l (all rights reserved); Tue Apr 13 04:54:24 EDT 2021
5
Downloaded/printed by
University Of Birmingham (University Of Birmingham) pursuant to License Agreement. No further reproductions authorized.
E21 − 20
specified in 9.4.4. Unless otherwise specified this time should 9.6.3.1 For specimens of normal size and ductility, attach an
not be less than 20 min. The time to attain specified tempera- extensometer to the reduced section.
ture and the time at specified temperature before testing shall 9.6.3.2 When metals of limited ductility are tested attach the
be maintained in the records (see 11.2.7.) extensometer to the specimen shoulders.
9.5 Connecting Specimen to the Machine—Take care not to 9.6.3.3 For miniature specimens, measure coupling or
introduce nonaxial forces while installing the specimen. For crosshead separation to determine an approximate yield
example, threaded connections should not be turned to the end strength.
of the threads or “bottomed.” If threads are loosely fitted, 9.6.4 When the extensometer is attached to the reduced
lightly apply force to the specimen string and manually move section, a strain rate indicator or controller shall be used to
it in the transverse direction until the force drops to its maintain a rate of 0.005 6 0.002 in. ⁄in. ⁄min (mm/mm/min)
minimum value before testing. If packing is used to seal the through the yielding range except within the elastic range
furnace, it must not be so tight that the extensometer arms or where smaller strain rates are permissible.
pull rods are displaced or their movement restricted. NOTE 15—With conventional testing machines, the strain rate often
9.6 Strain Measurement and Strain Rate: cannot be controlled closely if the material yields in a relatively sudden
manner. In such cases the speed control should be preset to the rate which
9.6.1 During yield strength determination, maintain the experience shows will result in the specified strain rate at the force
strain rate in the reduced parallel section of the test specimen corresponding to the yield stress. This will usually be at a strain rate which
at 0.005 6 0.002 in./in./min (mm/mm/min). After yield will result from a rate of crosshead motion of 0.005 times the adjusted
strength determination, increase the rate of crosshead motion to length of the reduced section, per minute.
0.05 6 0.01 times the length of the reduced parallel section (A) 9.6.5 When the extensometer is attached to the specimen
of any of the specimen configurations described in Test shoulders, use the adjusted length of the reduced section to
Methods E8/E8M per minute. The speed of testing (strain rate calculate the setting of the strain-rate indicator or pacer during
or crosshead speed) shall be maintained in the records (see yielding. Otherwise the procedure is the same as that described
11.2.4). above.
NOTE 12—The tensile properties of material tested at elevated tempera- 9.6.6 When the stock size requires use of specimens less
ture are, in general, affected by the rate of deformation. It is therefore than 0.25 in. (6.4 mm) in diameter, the approximate 0.2 percent
important that this rate be controlled. offset yield strength may be determined from a record of
9.6.1.1 In cases where it is desired to establish the entire coupling or crosshead separation. In order to adjust for the
engineering stress strain curve of a specimen, the speed of extension which occurs outside the reduced section, two
testing may be maintained at 0.005 60.002 in./in./min (mm/ specimens must be tested, one with the standard reduced
mm/min) throughout the entire test section and the other, a shortened specimen, with similar grip
ends and shoulders but without fillets and reduced section. The
NOTE 13—Maintaining the strain rate in 9.6.1 may require the use of a latter need only be tested to the force level required to yield the
suitable extensometer system that has a calibrated range to record the
entire test and will not be damaged by the failure. Caution is advised since
former (see 10.1.3).
control problems can occur if an extensometer slips or behaves in an 9.6.7 To allow for the elastic strain in the machine parts,
unexpected manner. pull rods and grips, set the rate of crosshead motion during
9.6.1.2 If it has been established that the crosshead speed yielding at or slightly higher than the upper limit of the
remains constant within the tolerance above, the extensometer recommended range, that is 0.007 times the adjusted length of
and strain rate indicator may be used to set a strain rate of 0.05 the reduced section per minute. At strains exceeding that
6 0.01 in. ⁄in. ⁄min (mm/mm/min) after yield strength determi- corresponding to the yield strength of the material being tested,
nation. To protect it from damage, the sensing element of the apply the method of 9.6.2.
extensometer may be removed before maximum force is 9.7 Recording Maximum Force—If an autographic recorder
reached. of force and extension is used, continue the recording of force
NOTE 14—Even with constant crosshead speed, the strain rate in the
after the sensing element of the extensometer is removed. In
specimen may still vary. Before maximum force it will be less than the any case observe the maximum force and record manually.
nominal rate due to the elasticity of the machine and grips and the (See 11.2.3.)
progressive elongation of the specimen. After maximum force it will be
greater than the nominal rate due to nonuniform strain during necking. 9.8 Measurements of Specimen After Test:
Available experimental evidence does not justify the added complexity of 9.8.1 For measuring elongation, fit the ends of the fractured
maintaining a constant strain rate throughout the post-yield stages of a specimen together carefully and measure the distance between
tension test. gauge marks or the over-all length to the nearest 0.01 in. (0.3
9.6.2 When yield strength determination is not required, an mm) at room temperature.
extensometer need not be used. The rate of crosshead motion 9.8.2 If any part of the fracture surface extends beyond the
shall be maintained at 0.05 6 0.01 times the adjusted length of middle half of the reduced section, the elongation value
the reduced parallel section, per minute throughout the test. obtained may not be representative of the material. In the case
9.6.3 When yield strength determinations are required, ob- of an acceptance test, if the elongation meets the minimum
servations of force and extension during loading and through requirements specified, no further testing is required; but if the
yield are necessary. The following three means of making these elongation is less than the specified minimum the test may be
observations are acceptable: discarded and a retest made.

Copyright by ASTM Int'l (all rights reserved); Tue Apr 13 04:54:24 EDT 2021
6
Downloaded/printed by
University Of Birmingham (University Of Birmingham) pursuant to License Agreement. No further reproductions authorized.
E21 − 20
9.8.3 For measuring reduction of area of specimens of low ductility. Since these values are usually lower than those
circular cross section, fit the ends of the fractured specimen measured from the broken specimen, the method of measure-
together carefully and measure the minimum diameter to the ment shall be stated with the results (see 11.1.7.5.)
nearest 0.01 in. (0.3 mm) at room temperature. If the fracture 10.4 Reduction of Area—Reduction of area is equal to the
cross section is not round, make sufficient measurements to minimum cross-sectional area of the reduced section before
establish the cross-sectional area at fracture. If the fracture testing minus the minimum cross-sectional area of the reduced
occurs at a fillet or gauge mark the reduction of area may not section after testing, the difference expressed as a percentage of
be representative of the material. In the case of an acceptance the area before testing. Reduction of area is reported only for
test, if the reduction of area meets the specified minimum, no specimens of circular cross section (see 11.1.7.6.)
further testing is required, but if the reduction of area is less
than the specified minimum the test may be discarded and a 10.5 Rounding—Unless otherwise specified, for purposes of
retest made. determining compliance with specified limits, observed or
calculated values shall be rounded as indicated below, in
10. Calculations accordance with the Rounding Method of Practice E29 as
follows:
10.1 Yield Strength:
Rounded Unit for Observed or
10.1.1 Unless otherwise specified determine the yield Quantity Measured Calculated Value
strength reported at an offset of 0.2 % as described in Test Tensile or Yield Strength Nearest 500 psi (3.5 MPa)
Elongation or Reduction of Area Nearest 0.5 %
Methods E8/E8M.
NOTE 16—The accurate measurement of proportional limit and offset 11. Report and Records
yield strength of 0.02 % or less is extremely difficult at elevated
temperatures. Even though the extensometer has the required accuracy 11.1 The following information shall be included in the
and sensitivity during room-temperature calibration, this is not assurance report, unless otherwise agreed upon between the customer and
that the strain measurements during the elevated-temperature tension test supplier:
will have equal accuracy. High temperature at the attachment points and 11.1.1 Reference to the standard used (ASTM E21)
extensometer rods passing through the furnace packing will probably
reduce the accuracy significantly. Therefore, the determination of propor- 11.1.2 Specimen identification.
tional limit and offset yield strength of 0.02 % or less is not recommended. 11.1.3 Material identification (for example alloy, temper,
10.1.2 If the extensometer must be attached to the specimen heat treatment(s), product form and thickness or diameter).
shoulders, base the offset extension (inches or millimeters) on 11.1.4 Specimen type (for example round, rectangular, full
the adjusted length of the reduced section, that is, 0.002 times cross section) and specimen reference (for example specimen
the adjusted length of the reduced section for 0.2 percent offset drawing, Test Methods E8/E8M).
yield strength and corresponding values for other yield 11.1.5 Specified temperature and the magnitude and dura-
strengths. tion of all temperature overshoots discussed in 9.4.4 and 9.4.6.
10.1.3 If coupling or crosshead separation are recorded 11.1.6 Speed of testing if different than that required in the
adjust the observed extension in the following two steps. First, material specification or that specified in 9.6.1.
to compensate for machine elasticity, grip distortion and 11.1.7 Elevated temperature properties that are specified by
shoulder strain, reduce values for the standard specimen by the the material specification. These typically include, but are not
values for the shortened specimen (9.6.6) at corresponding limited to yield strength, tensile strength, elongation and
applied forces. Second, treat this adjusted strain datum by the reduction of area.
method of 10.1.2. Report only yield strengths with offsets of 11.1.7.1 Yield strength and the method of calculation (for
0.2 % or more and label these “approximate yield strength” example 0.2 % offset yield strength, 0.02 % offset yield
(see 11.1.7.1 – 11.1.7.3.) strength, upper yield strength, see Test Methods E8/E8M;
approximate yield strength, see 10.1.3).
10.2 Tensile Strength—Calculate the tensile strength by 11.1.7.2 If strain was measured from the specimen
dividing the maximum force, during a test carried to fracture, shoulders, or if strain was not measured directly from the
by the original minimum cross-sectional area of the reduced specimen (for example from an extensometer that was attached
section. to grips or adapters), this shall be stated in a footnote to the
10.3 Elongation: values.
10.3.1 When the gauge length is marked on the reduced 11.1.7.3 When strain was not measured directly from the
section having a nominally uniform cross-sectional area, the specimen, the yield strength value shall be listed as approxi-
elongation is equal to the gauge length after fracture minus the mate followed by the offset, for example “approximate yield
original gauge length, the difference expressed as a percentage strength (offset = 0.2 %)” (see 10.1.3).
of the original gauge length. If the gauge length includes fillets, 11.1.7.4 Tensile strength.
shoulders, threads, etc., the change in gauge length is expressed 11.1.7.5 Elongation, the method of measure (elongation
as a percentage of the adjusted length of the reduced section. after fracture or elongation at fracture) and gauge length (for
10.3.2 A method that can sometimes be used when there is example, 2 in. for rectangular specimens or 4D or 5D for
autographic recording of strain up to the moment of fracture, is round).
to read the elongation as strain offset from the initial, linear, 11.1.7.6 Reduction of area for specimens with circular cross
loading line. This can be useful in the case of materials of very section.

Copyright by ASTM Int'l (all rights reserved); Tue Apr 13 04:54:24 EDT 2021
7
Downloaded/printed by
University Of Birmingham (University Of Birmingham) pursuant to License Agreement. No further reproductions authorized.
E21 − 20
11.1.8 Specification limits and disposition of each test result 11.2.5 If a replacement test is performed to replace an
(conforming/non-conforming), when required by customer. invalid result, the specimen identification for the invalid test
11.1.9 Location of fracture, if outside of center half of gauge and reason for replacement shall be maintained in the records.
length. 11.2.6 Equipment identification, including testing machine,
11.1.10 Test or specimen anomalies, for example incorrect extensometer, furnace, thermocouple type and traceability,
test speed, failure in the grip threads, specimen machined out laboratory test methods, etc.
of tolerance, magnitude of deviations from those specified in 11.2.7 Time to attain specified temperature and time at
7.6, nonstandard atmosphere and heating methods, and excep- specified temperature before testing.
tions to required dimensional accuracy and axiality of loading. 11.2.8 Identification of individual who performed the test.
If a replacement test is performed to replace an invalid result, 11.2.9 Date of test.
the reason for replacement test result shall be maintained in the
records (see 11.2.5). 12. Precision and Bias
11.1.11 Identification of the individual who approved the
test or report. 12.1 Precision—An inter-laboratory test program9 gave the
11.1.12 Date of report approval. following values for coefficients of variation for the most
commonly measured tensile properties:10
11.2 The following information shall be maintained in the
Coefficient of Variation, % Tensile Properties at 600 °F (316 °C)
records (in addition to the information in the report in 11.1): Elongation
Yield
11.2.1 Gauge length, distance between measurement points Tensile
Strength
gauge Reduction of
on specimen shoulder (if used) and overall length (if used). Strength length = 4 Area
offset = 0.2 %
diameters
11.2.2 Measured critical dimensions used to determine the CV %r 1.0 3.0 3.8 4.6
minimum cross-sectional area of the reduced section (for CV %R 1.4 5.1 8.2 4.9
example, diameter or width and thickness). CV %r = repeatability coefficent of variation in percent within a laboratory.
CV %R = repeatability coefficient of variation in percent between laboratories.
11.2.3 Stress, strain, force, maximum force, displacement,
indicated temperature, time data. In cases where yield strength
measurements are not required, see 9.6.2, a subset including
stress, force, displacement, indicated temperature, and time
data may be recorded. 9
Supporting data are available from ASTM Headquarters. Request RR:E28-
11.2.4 Speed of testing (for example, strain rate or cross- 1015.
head speed). 10
For further information, see Practice E177 and Practice E691.

Copyright by ASTM Int'l (all rights reserved); Tue Apr 13 04:54:24 EDT 2021
8
Downloaded/printed by
University Of Birmingham (University Of Birmingham) pursuant to License Agreement. No further reproductions authorized.
E21 − 20

Coefficient of Variation, % Tensile Properties at 1100°F (593°C) should not be used to judge whether the difference between
Yield
Elongation duplicate tests of a specific material is larger than expected.
Tensile gauge Reduction of
Strength
Strength
length = 4 Area
The values are provided to allow potential users of this test
offset = 0.2 %
diameters method to assess, in general terms, its usefulness for a
CV %r 2.8 4.2 6.8 2.8 proposed application.
CV %R 4.5 7.6 15.6 4.5
CV %r = repeatability coefficent of variation in percent within a laboratory. 12.2 Bias—The procedures in Test Methods E21 for mea-
CV %R = repeatability coefficient of variation in percent between laboratories.
suring tensile properties have no bias because these properties
12.1.1 The values shown are the averages from tests on four can only be defined in terms of a test method.
frequently tested metals at two specified temperatures, selected
to include most of the normal range for each property listed 13. Keywords
above. When these materials are compared, a large difference 13.1 elevated temperature; elongation; reduction of area;
in coefficient of variation is found. Therefore, the values above strain rate; tensile strength; yield strength

SUMMARY OF CHANGES

Committee E28 has identified the location of selected changes to this standard since the last issue (E21 – 17ɛ1)
that may impact the use of this standard.

(1) Section 3—revised to add indicated temperature, specified (4) Sections 7, 9, 10, and 11— revised reporting and recording
temperature, and temperature-measuring system. requirements throughout.
(2) Throughout—clarified temperature terminology to clearly (5) Added Section 13, Keywords.
describe “indicated” and “specified” temperatures. Added ref- (6) Section 9.4.4—clarified requirements for the temperature
erences to “temperature-measuring system” where needed for limits (indicated versus specified) after yield strength determi-
clarification. nation. Added note describing reasons for temperature differ-
(3) Throughout—standardized units to conform with the H4 ences caused by factors other than the heating apparatus.
inch-pound unit designation. Changed fractions to equivalent (7) Section 12—Corrected values for coefficient of variation at
decimal units. 1100 °F (593 °C)

ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.

This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.

This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222
Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http://www.copyright.com/

Copyright by ASTM Int'l (all rights reserved); Tue Apr 13 04:54:24 EDT 2021