You are on page 1of 9

How to judge the left or right hand

connection for MCW

Left hand connection Right hand connection

Exchange the connection for MCW


MCW structure
Motor
Fan

Motor Panel

Electric Box

Coil
Air Vent Valve
(Manually)
Condensate
Drain Pan
Deflector
Top Panel
MCW pipe connection exchange notice:

Step 1: Remove
the motor panel
MCW pipe connection exchange notice:

Step 2: Remove
the top panel
MCW pipe connection exchange notice:

Step 3: Remove
the screws which fix
coil and deflector
MCW pipe connection exchange notice:
Step 4: Change the
orientation of deflector

Before After
MCW pipe connection exchange notice:
Step 5: Exchange the side panel

Before

After
MCW pipe connection exchange notice:
Step 6: Install the deflector, fix the coil, and
install the top panel

Deflector Top Panel


MCW pipe connection exchange notice:

Before After