- not to scale -
Technical data
No. of Fibres 4
Design (Elements × Fibres per Tube) 6x4
Loose Tube / Filler - Ø mm 2.0
CSM/sheath diameter mm 2.2
Outer sheath thickness mm 1.8 nominal
Cable Diameter mm 10.0 nominal
Cable Weight kg / km 104
Max installation tension N 1500
Min. bending radius mm Without Tension Under Maximum Tension
10 × Cable-Ø 20 × Cable-Ø
Temperature range °C Installation Transport. & Storage Operation
-10 -> +60; -40 -> +70 ; -40 -> +70
Please refer to our General Installation, Safety & Handling recommendations before handling.
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 1500N fibre strain 0.33%, reversible
Crush(short term) IEC 60794-1-2-E3 1500 N / 100mm 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C 0.3 dB/km(MM), 0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour
* values for single-mode fibres, all optical measurements performed at 1550 nm.
* values for multi-mode fibres, all optical measurements performed at 1300 nm
Optical Characteristics
See the attached cabled optical fibre data sheet.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 3 of 28
TD 15-487
- not to scale -
Technical data
No. of Fibres 6
Design (Elements × Fibres per Tube) 6x6
Loose Tube / Filler - Ø mm 2.0
CSM/sheath diameter mm 2.2
Outer sheath thickness mm 1.8 nominal
Cable Diameter mm 10.0 nominal
Cable Weight kg / km 104
Max installation tension N 1500
Min. bending radius mm Without Tension Under Maximum Tension
10 × Cable-Ø 20 × Cable-Ø
Temperature range °C Installation Transport. & Storage Operation
-10 -> +60; -40 -> +70 ; -40 -> +70
Please refer to our General Installation, Safety & Handling recommendations before handling.
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 1500N fibre strain 0.33%, reversible
Crush(short term) IEC 60794-1-2-E3 1500 N / 100mm 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C 0.3 dB/km(MM), 0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour
* values for single-mode fibres, all optical measurements performed at 1550 nm.
* values for multi-mode fibres, all optical measurements performed at 1300 nm
Optical Characteristics
See the attached cabled optical fibre data sheet.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 4 of 28
TD 15-487
- not to scale -
Technical data
No. of Fibres 8
Design (Elements × Fibres per Tube) 6x4
Loose Tube / Filler - Ø mm 2.0
CSM/sheath diameter mm 2.2
Outer sheath thickness mm 1.8 nominal
Cable Diameter mm 10.0 nominal
Cable Weight kg / km 104
Max installation tension N 1500
Min. bending radius mm Without Tension Under Maximum Tension
10 × Cable-Ø 20 × Cable-Ø
Temperature range °C Installation Transport. & Storage Operation
-10 -> +60; -40 -> +70 ; -40 -> +70
Please refer to our General Installation, Safety & Handling recommendations before handling.
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 1500N fibre strain 0.33%, reversible
Crush(short term) IEC 60794-1-2-E3 1500 N / 100mm 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C 0.3 dB/km(MM), 0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour
* values for single-mode fibres, all optical measurements performed at 1550 nm.
* values for multi-mode fibres, all optical measurements performed at 1300 nm
Optical Characteristics
See the attached cabled optical fibre data sheet.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 5 of 28
TD 15-487
- not to scale -
Technical data
No. of Fibres 12
Design (Elements × Fibres per Tube) 6x6
Loose Tube / Filler - Ø mm 2.0
CSM/sheath diameter mm 2.2
Outer sheath thickness mm 1.8 nominal
Cable Diameter mm 10.0 nominal
Cable Weight kg / km 104
Max installation tension N 1500
Min. bending radius mm Without Tension Under Maximum Tension
10 × Cable-Ø 20 × Cable-Ø
Temperature range °C Installation Transport. & Storage Operation
-10 -> +60; -40 -> +70 ; -40 -> +70
Please refer to our General Installation, Safety & Handling recommendations before handling.
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 1500N fibre strain 0.33%, reversible
Crush(short term) IEC 60794-1-2-E3 1500 N / 100mm 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C 0.3 dB/km(MM), 0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour
* values for single-mode fibres, all optical measurements performed at 1550 nm.
* values for multi-mode fibres, all optical measurements performed at 1300 nm
Optical Characteristics
See the attached cabled optical fibre data sheet.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 6 of 28
TD 15-487
- not to scale -
Technical data
No. of Fibres 24
Design (Elements × Fibres per Tube) 6x6
Loose Tube / Filler - Ø mm 2.0
CSM/sheath diameter mm 2.2
Outer sheath thickness mm 1.8 nominal
Cable Diameter mm 10.0 nominal
Cable Weight kg / km 104
Max installation tension N 1500
Min. bending radius mm Without Tension Under Maximum Tension
10 × Cable-Ø 20 × Cable-Ø
Temperature range °C Installation Transport. & Storage Operation
-10 -> +60; -40 -> +70 ; -40 -> +70
Please refer to our General Installation, Safety & Handling recommendations before handling.
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 1500N fibre strain 0.33%, reversible
Crush(short term) IEC 60794-1-2-E3 1500 N / 100mm 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C 0.3 dB/km(MM), 0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour
* values for single-mode fibres, all optical measurements performed at 1550 nm.
* values for multi-mode fibres, all optical measurements performed at 1300 nm
Optical Characteristics
See the attached cabled optical fibre data sheet.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 7 of 28
TD 15-487
- not to scale -
Technical data
No. of Fibres 48
Design (Elements × Fibres per Tube) 6x12
Loose Tube / Filler - Ø mm 2.0
CSM/sheath diameter mm 2.2
Outer sheath thickness mm 1.8 nominal
Cable Diameter mm 10.0 nominal
Cable Weight kg / km 104
Max installation tension N 1500
Min. bending radius mm Without Tension Under Maximum Tension
10 × Cable-Ø 20 × Cable-Ø
Temperature range °C Installation Transport. & Storage Operation
-10 -> +60; -40 -> +70 ; -40 -> +70
Please refer to our General Installation, Safety & Handling recommendations before handling.
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 1500N fibre strain 0.33%, reversible
Crush(short term) IEC 60794-1-2-E3 1500 N / 100mm 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C 0.3 dB/km(MM), 0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour
* values for single-mode fibres, all optical measurements performed at 1550 nm.
* values for multi-mode fibres, all optical measurements performed at 1300 nm
Optical Characteristics
See the attached cabled optical fibre data sheet.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 8 of 28
TD 15-487
- not to scale -
Technical data
No. of Fibres 96
Design (Elements × Fibres per Tube) 8×12
Loose Tube / Filler - Ø mm 2.0
CSM/sheath diameter mm 2.0/3.5
Outer sheath thickness mm 1.8 nominal
Cable Diameter mm 11.3 nominal
Cable Weight kg / km 116
Max installation tension N 1500
Min. bending radius mm Without Tension Under Maximum Tension
10 × Cable-Ø 20 × Cable-Ø
Temperature range °C Installation Transport. & Storage Operation
-10 -> +60; -40 -> +70 ; -40 -> +70
Please refer to our General Installation, Safety & Handling recommendations before handling.
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 1500N fibre strain 0.33%, reversible
Crush(short term) IEC 60794-1-2-E3 1500 N / 100mm 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C 0.3 dB/km(MM), 0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour
* values for single-mode fibres, all optical measurements performed at 1550 nm.
* values for multi-mode fibres, all optical measurements performed at 1300 nm
Optical Characteristics
See the attached cabled optical fibre data sheet.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 9 of 28
TD 15-487
Identification
Fibre Colours
No. 1 2 3 4 5 6 7 8 9 10 11 12
Colour blue orange green brown grey white red black yellow violet pink aqua
Sheath Colour:
The outer sheath is black.
Sheath Marking:
The outer sheath is marked in 1 meter intervals as follows:
NETVIEL PRYSMIAN <YEAR> FIBRE OPTICS CABLE DUCT xxF <fiber type> XXXXM
Fiber type: SM G652D 9/125; MM OM1 62.5/125; MM OM2 50/125; MM OM3 50/125, MM OM4 50/125
Logistic
Packing:
Wooden drums with protection.
Delivery Lengths:
Standard delivery length is 4 km with a tolerance of ± 5%.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 10 of 28
TD 15-487
- not to scale -
Technical data
No. of Fibres 4
Design (Elements × Fibres per Tube) 6x4
Loose Tube / Filler - Ø mm 2.0
CSM/sheath diameter mm 2.2
Inner sheath thickness mm 0.8 nominal
Outer sheath thickness mm 1.8 nominal
Cable Diameter mm 13.1 nominal
Cable Weight kg / km 192
Max installation tension N 3000
Min. bending radius mm Without Tension Under Maximum Tension
10 × Cable-Ø 20 × Cable-Ø
Temperature range °C Installation Transport. & Storage Operation
-10 -> +60; -40 -> +70 ; -40 -> +70
Please refer to our General Installation, Safety & Handling recommendations before handling.
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 3000N fibre strain 0.33%, reversible
Crush(short term) IEC 60794-1-2-E3 3000 N / 100mm 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C 0.3 dB/km(MM), 0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour
* values for single-mode fibres, all optical measurements performed at 1550 nm.
* values for multi-mode fibres, all optical measurements performed at 1300 nm
Optical Characteristics
See the attached cabled optical fibre data sheet.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 11 of 28
TD 15-487
- not to scale -
Technical data
No. of Fibres 6
Design (Elements × Fibres per Tube) 6x6
Loose Tube / Filler - Ø mm 2.0
CSM/sheath diameter mm 2.2
Inner sheath thickness mm 0.8 nominal
Outer sheath thickness mm 1.8 nominal
Cable Diameter mm 13.1 nominal
Cable Weight kg / km 192
Max installation tension N 3000
Min. bending radius mm Without Tension Under Maximum Tension
10 × Cable-Ø 20 × Cable-Ø
Temperature range °C Installation Transport. & Storage Operation
-10 -> +60; -40 -> +70 ; -40 -> +70
Please refer to our General Installation, Safety & Handling recommendations before handling.
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 3000N fibre strain 0.33%, reversible
Crush(short term) IEC 60794-1-2-E3 3000 N / 100mm 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C 0.3 dB/km(MM), 0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour
* values for single-mode fibres, all optical measurements performed at 1550 nm.
* values for multi-mode fibres, all optical measurements performed at 1300 nm
Optical Characteristics
See the attached cabled optical fibre data sheet.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 12 of 28
TD 15-487
- not to scale -
Technical data
No. of Fibres 8
Design (Elements × Fibres per Tube) 6x4
Loose Tube / Filler - Ø mm 2.0
CSM/sheath diameter mm 2.2
Inner sheath thickness mm 0.8 nominal
Outer sheath thickness mm 1.8 nominal
Cable Diameter mm 13.1 nominal
Cable Weight kg / km 192
Max installation tension N 3000
Min. bending radius mm Without Tension Under Maximum Tension
10 × Cable-Ø 20 × Cable-Ø
Temperature range °C Installation Transport. & Storage Operation
-10 -> +60; -40 -> +70 ; -40 -> +70
Please refer to our General Installation, Safety & Handling recommendations before handling.
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 3000N fibre strain 0.33%, reversible
Crush(short term) IEC 60794-1-2-E3 3000 N / 100mm 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C 0.3 dB/km(MM), 0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour
* values for single-mode fibres, all optical measurements performed at 1550 nm.
* values for multi-mode fibres, all optical measurements performed at 1300 nm
Optical Characteristics
See the attached cabled optical fibre data sheet.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 13 of 28
TD 15-487
- not to scale -
Technical data
No. of Fibres 12
Design (Elements × Fibres per Tube) 6x6
Loose Tube / Filler - Ø mm 2.0
CSM/sheath diameter mm 2.2
Inner sheath thickness mm 0.8 nominal
Outer sheath thickness mm 1.8 nominal
Cable Diameter mm 13.1 nominal
Cable Weight kg / km 192
Max installation tension N 3000
Min. bending radius mm Without Tension Under Maximum Tension
10 × Cable-Ø 20 × Cable-Ø
Temperature range °C Installation Transport. & Storage Operation
-10 -> +60; -40 -> +70 ; -40 -> +70
Please refer to our General Installation, Safety & Handling recommendations before handling.
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 3000N fibre strain 0.33%, reversible
Crush(short term) IEC 60794-1-2-E3 3000 N / 100mm 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C 0.3 dB/km(MM), 0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour
* values for single-mode fibres, all optical measurements performed at 1550 nm.
* values for multi-mode fibres, all optical measurements performed at 1300 nm
Optical Characteristics
See the attached cabled optical fibre data sheet.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 14 of 28
TD 15-487
- not to scale -
Technical data
No. of Fibres 24
Design (Elements × Fibres per Tube) 6x6
Loose Tube / Filler - Ø mm 2.0
CSM/sheath diameter mm 2.2
Inner sheath thickness mm 0.8 nominal
Outer sheath thickness mm 1.8 nominal
Cable Diameter mm 13.1 nominal
Cable Weight kg / km 192
Max installation tension N 3000
Min. bending radius mm Without Tension Under Maximum Tension
10 × Cable-Ø 20 × Cable-Ø
Temperature range °C Installation Transport. & Storage Operation
-10 -> +60; -40 -> +70 ; -40 -> +70
Please refer to our General Installation, Safety & Handling recommendations before handling.
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 3000N fibre strain 0.33%, reversible
Crush(short term) IEC 60794-1-2-E3 3000 N / 100mm 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C 0.3 dB/km(MM), 0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour
* values for single-mode fibres, all optical measurements performed at 1550 nm.
* values for multi-mode fibres, all optical measurements performed at 1300 nm
Optical Characteristics
See the attached cabled optical fibre data sheet.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 15 of 28
TD 15-487
- not to scale -
Technical data
No. of Fibres 48
Design (Elements × Fibres per Tube) 6x12
Loose Tube / Filler - Ø mm 2.0
CSM/sheath diameter mm 2.2
Inner sheath thickness mm 0.8 nominal
Outer sheath thickness mm 1.8 nominal
Cable Diameter mm 13.1 nominal
Cable Weight kg / km 192
Max installation tension N 3000
Min. bending radius mm Without Tension Under Maximum Tension
10 × Cable-Ø 20 × Cable-Ø
Temperature range °C Installation Transport. & Storage Operation
-10 -> +60; -40 -> +70 ; -40 -> +70
Please refer to our General Installation, Safety & Handling recommendations before handling.
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 3000N fibre strain 0.33%, reversible
Crush(short term) IEC 60794-1-2-E3 3000 N / 100mm 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C 0.3 dB/km(MM), 0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour
* values for single-mode fibres, all optical measurements performed at 1550 nm.
* values for multi-mode fibres, all optical measurements performed at 1300 nm
Optical Characteristics
See the attached cabled optical fibre data sheet.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 16 of 28
TD 15-487
- not to scale -
Technical data
No. of Fibres 96
Design (Elements × Fibres per Tube) 8×12
Loose Tube / Filler - Ø mm 2.0
CSM/sheath diameter mm 2.0/3.5
Inner sheath thickness mm 0.8 nominal
Outer sheath thickness mm 1.8 nominal
Cable Diameter mm 14.4 nominal
Cable Weight kg / km 215
Max installation tension N 3000
Min. bending radius mm Without Tension Under Maximum Tension
10 × Cable-Ø 20 × Cable-Ø
Temperature range °C Installation Transport. & Storage Operation
-10 -> +60; -40 -> +70 ; -40 -> +70
Please refer to our General Installation, Safety & Handling recommendations before handling.
Main characteristics
Test Standard Value Sanction*
Max. installation tension IEC 60794-1-2-E1 3000N fibre strain 0.33%, reversible
Crush(short term) IEC 60794-1-2-E3 3000 N / 100mm 0.3 dB(MM), 0.1 dB(SM)
Temperature range IEC 60794-1-2-F1 -40 -> +70°C 0.3 dB/km(MM), 0.1 dB/km(SM)
Water Penetration IEC 60794-1-2-F5B sample=3m, water=1m No water leakage after 24 hour
* values for single-mode fibres, all optical measurements performed at 1550 nm.
* values for multi-mode fibres, all optical measurements performed at 1300 nm
Optical Characteristics
See the attached cabled optical fibre data sheet.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 17 of 28
TD 15-487
Identification
Fibre Colours
No. 1 2 3 4 5 6 7 8 9 10 11 12
Colour blue orange green brown grey white red black yellow violet pink aqua
Sheath Colour:
The inner and outer sheath is black.
Sheath Marking:
The outer sheath is marked in 1 meter intervals as follows:
NETVIEL PRYSMIAN <YEAR> FIBRE OPTICS CABLE ARMOURED xxF <fiber type> XXXXM
Fiber type: SM G652D 9/125; MM OM1 62.5/125; MM OM2 50/125; MM OM3 50/125, MM OM4 50/125
Logistic
Packing:
Wooden drums with protection.
Delivery Lengths:
Standard delivery length is 4 km with a tolerance of ± 5%.
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 18 of 28
TD 15-487
Optical properties
Attribute Measurement method Units Limits
Mode field diameter at 1310 nm μm 9.2 ± 0.4
IEC/EN 60793-1-45
Mode field diameter at 1550 nm μm 10.1 ± 0.5
Chromatic dispersion coefficient: IEC/EN 60793-1-42
In the interval 1285 nm – 1330 nm ps/km ● nm ≤ ︱3.5︱
At 1550 nm ps/km ● nm ≤ 18.0
At 1625 nm ps/km ● nm ≤ 22.0
Zero dispersion wavelength, λ0 nm 1300 - 1324
2
Zero dispersion slope ps/(nm ● km) ≤ 0.092
Cut-off wavelength IEC/EN 60793-1-44 λCC nm ≤ 1260 *
Polarisation mode dispersion (PMD) coefficient, cabled IEC/EN 60793-1-48 ps/√km ≤ 0.2
PMDQ Link Design Value
IEC/EN 60794-3 ps/√km ≤ 0.06
(computed with Q=0.01%, N=20)
* guaranteed value according to the ITU-T (ASTM G650) method
Attenuation
Attribute Measurement method Units Limits
Maximum attenuation value of cable at 1310 nm IEC/EN 60793-1-40 db/km ≤ 0.35
Maximum attenuation value of cable at 1550 nm IEC/EN 60793-1-40 db/km ≤ 0.21
Inhomogeneity of OTDR trace for any two 1000 meter fibre lengths db/km Max. 0.1
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 19 of 28
TD 15-487
Geometrical properties
Attribute Measurement method Units Limits
Cladding diameter IEC/EN 60793-1-20 μm 125.0 ± 0.7
Cladding non-circularity IEC/EN 60793-1-20 % ≤ 1.0
Core (MDF) – cladding concentricity error IEC/EN 60793-1-20 μm ≤ 0.6
Primary coating diameter - ColorLock®XS and natural IEC/EN 60793-1-21 μm 245 ± 10
Primary coating non-circularity IEC/EN 60793-1-21 % ≤6
Primary coating-cladding concentricity error IEC/EN 60793-1-21 μm ≤ 12
Mechanical properties
Attribute Measurement method Units Limits
Proof stress level IEC/EN 60793-1-30 Gpa ≥ 0.7 (≈ 1%)
Strip force (peak) IEC/EN 60793-1-32 N 1.2 ≤ Fpeak.strip ≤ 8.9
Dynamic fatigue resistance aged and unaged (Nd) IEC/EN 60793-1-33 ≥ 20
Static fatigue, aged ns IEC/EN 60793-1-33 ≥ 23
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 20 of 28
TD 15-487
Optical properties
Attribute Measurement method Units Limits
Attenuation
Attribute Measurement method Units Limits
Inhomogeneity of OTDR trace for any two 1000 meter fibre lengths db/km Max. 0.1
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 21 of 28
TD 15-487
Geometrical properties
Attribute Measurement method Units Limits
Mechanical properties
Attribute Measurement method Units Limits
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 22 of 28
TD 15-487
Optical properties
Attribute Measurement method Units Limits
Attenuation
Attribute Measurement method Units Limits
Inhomogeneity of OTDR trace for any two 1000 meter fibre lengths db/km Max. 0.1
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 23 of 28
TD 15-487
Geometrical properties
Attribute Measurement method Units Limits
Mechanical properties
Attribute Measurement method Units Limits
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 24 of 28
TD 15-487
Optical properties
Attribute Measurement method Units Limits
Core diameter IEC/EN 60793-1-20 μm 50.0 ± 2.5
Attenuation
Attribute Measurement method Units Limits
Maximum attenuation value of cable at 850 nm IEC/EN 60793-1-40 db/km ≤ 3.0
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 25 of 28
TD 15-487
Geometrical properties
Attribute Measurement method Units Limits
Cladding diameter IEC/EN 60793-1-20 μm 125.0 ± 1.0
Cladding non-circularity IEC/EN 60793-1-20 % ≤ 1.0
Core (MDF) – cladding concentricity error IEC/EN 60793-1-20 μm ≤ 1.5
Primary coating diameter IEC/EN 60793-1-21 μm 245 ± 10
Primary coating non-circularity IEC/EN 60793-1-21 % ≤6
Mechanical properties
Attribute Measurement method Units Limits
Proof stress level IEC/EN 60793-1-30 Gpa ≥ 0.7 (≈ 1%)
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 26 of 28
TD 15-487
Optical properties
Attribute Measurement method Units Limits
Core diameter IEC/EN 60793-1-20 μm 50.0 ± 2.5
Overfilled Modal Bandwidth at 850 nm IEC/EN 60793-1-41 Mhz.km ≥ 3500
Overfilled Modal Bandwidth at 1300 nm Mhz.km ≥ 500
Attenuation
Attribute Measurement method Units Limits
Loose Tube
TD 15-487 Issue 02
www.netviel.com Issued 2016-05-11 PR/ Page 27 of 28
TD 15-487
Geometrical properties
Attribute Measurement method Units Limits
Cladding diameter IEC/EN 60793-1-20 μm 125.0 ± 1.0
Cladding non-circularity IEC/EN 60793-1-20 % ≤ 1.0
Core (MDF) – cladding concentricity error IEC/EN 60793-1-20 μm ≤ 1.5
Primary coating diameter IEC/EN 60793-1-21 μm 245 ± 10
Primary coating non-circularity IEC/EN 60793-1-21 % ≤6
Mechanical properties
Attribute Measurement method Units Limits
Proof stress level IEC/EN 60793-1-30 Gpa ≥ 0.7 (≈ 1%)
Loose Tube
TD 15-487 Issue 02