OWNER'S MANUAL
ENGLISHTAOPFRCDU
?
Please read carefully and thoroughly this manual
before operating this unit.
?
Contact the authorized SVC man for repair or
property.
TroubleshtingpCadMcOISfyP
Care and Maintenance The following items are classified by these symblos.
Care and Maintenance .......16
WARNING
WARNING
Plug in the power plug Do not operate or stop the unit by Do not damage or use an
properly. inserting or pulling out the power plug. unspecified power cord.
?
Otherwise, it will cause electric shock ?
It will cause electric shock or fire due ?
It will cause electric shock or fire.
or fire due to heat generation or to heat generation. ?
In the supply cord is damaged, it mut be
electric shock. replaced by the manufacturer or its service
agent or a similarly quallfied person in order
to avoid a hazard. (Y Attachment)
Do not modify power cord length or Do not operate with wet hands or in Do not direct airflow at room occupants
share the outlet with other appliances. damp environment. only.
?
It will cause electric shock or fire due ?
It may cause electric shock. ?
This could damage your health.
to heat generation.
Always perform grounding work. Do not allow water to run into Always install airleakage breaker
electric parts. and a dedicated switching board.
?
No grounding may cause electric ?
It may cause failure of machine or ?
No installation may cause fire and
shock. electric shock. electric shock accident.
Unplug the unit if strange Do not use the socket if it is Do not open the entrance
sounds, smell, or smoke loose or damaged. during operation.
comes from it.
?
It may cause fire and electric ?
It may cause fire and electric ?
It may cause electric shock.
shock accident. shock.
Keep firearms away. Do not use the power cord close to the Do not use the power cord near flammable
2
WARNING
WARNING
Ventilate before operating air conditioner Do not disassemble or modify products
ENGLISH
when gas goes out. randomly.
?
It may cause explosion, fire and, burn. ?
It may cause failure and electric shock.
CAUTION
CAUTION
Never touch the metal parts Do not clean the air Ventilate well when used
of the unit when removing conditioner with water. together with a stove, etc.
the filter.
?
They are sharp and may cause ?
Water may enter the unit and ?
An oxygen shortage may occur.
When cleaning the unit, Do not put a pet or house Do not use appliance for special
first make the power
sure plant where it will be purpose such as animals or
and breaker are turned off. exposed to direct air flow. vegetables, precision machine,
or conservation of art articles.
?
Since the fan rotates at high ?
This could injure the pet or ?
It may cause damage of animals
speed during operation, it may plant. or vegetables or loss of
cause injury. property.
Stop operation and close Hold the plug by the head of Turn off the main power
the window in storm or the power plug when taking switch when not using it for
hurricane. it out. a long time.
?
Operation with windows opened ?
It may cause electric shock and ?
It may cause failure of product
may cause wetting of indoor and damage. or fire.
soaking of household furniture.
Do not place obstacles Ensure that an installation console of Always insert the filters
around the absorption inlet or the outdoor appliance is not damaged securely. Clean it once
instead of blowing-out inlet. due to the use for a long time. every two weeks.
?
It may cause failure of appliance ?
Ifleaving appliance damaged, ?
Operation without filters may
or accident. there is concern of damage due cause failure.
to the falling of product.
Do not use strong detergent Do not place heavy object on the Do not drink water drained
such as wax or thinner but power cord and take care so that from air conditioner.
use a soft cloth. the cord should not be pressed.
?
Appearance may be deteriorated ?
There is danger of fire or electric ?
It contains contaminants and will
due to change of product color or shock. make you sick.
scratching of its surface.
Use caution when unpacking and installing. If water enters the
product, turn the power
Sharp edges could cause injury. switch of the main body of appliance off. After
taking the power-plug out from the socket,
contact with the service center.
3
Preparation before operation
How to Insert the Batteries
Insert new batteries making sure that the (+) and (-) of
battery are installed correctly.
NOTES:
TroubleshtingpCadMcOISfyP
?
Use 2 AAA(1.5volt) batteries. Do not use rechargeable
batteries.
Signal Receptor
Receives the signals from the remote control.(Signal receiving sound: two short beeps or one long beep.)
Operation Indication Lamps
Plasma : The function illustrates its dynamic mode by using a multiple lighting system.
4
About the remote control on the system
The remote control transmits the signals to the system.
2
1
START/STOP BUTTON
Operation starts when this button is pressed
and stops when the button is pressed again.
5
How to use the Operation Mode Selection button
Cooling Operation
Press the Start/Stop button.
1 The unit will respond with
a beep.
TroubleshtingpCadMcOISfyP
Open the door on the remote control. To select Cooling
2 Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
6
Auto Operation
1
Press the
The unit will
a beep.
Start/Stop button.
respond with
ENGLISH
Open the door on the remote control. To select Auto
2 Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
7
Healthy Dehumidification Operation
Press the Start/Stop button.
1 The unit will respond with
a beep.
TroubleshtingpCadMcOISfyP
Open the door on the remote control. To select Healthy
2 Dehumidification Operation, press the Operation Mode
Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
During the healthy dehumidification function, the airflow volume is automatically set according to the
optimization algorithm responding to the current room temp. status which makes the room condition
healthy and comfortable even in the high humidity season.
8
Heating Operation(Heat pump model only)
1
Press the
The unit will
a beep.
Start/Stop button.
respond with
ENGLISH
Open the door on the remote control. To select Heating
2 Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
9
Jet Cool Operation
TroubleshtingpCadMcOISfyP
Press the Jet Cool button to operate
2 the speed cooling mode and the unit
will operate in super high fan speed
on cooling mode for 30 minutes.
To cancel the Jet Cool mode, press the Jet Cool button or
3 the fan speed button or the
room temperature setting button
again and the unit will operate in high fan speed on cooling
mode.
or or
NOTE:
During the JET COOL function at any moment, the A/C starts to blow the cool air at
extremely high speed for 30 minutes setting the room temp. automatically to 18°C. It is
especially used to cool the room temp. in the shortest time in a hot summer.
In heat pump mode or neuro fuzzy mode, however, the JET COOL function is not available.
In order to return to the normal coolingmode from the JET COOL mode, you just press
either the operation mode selection button, airflow volume selection or temp. setting button
or the JET COOL button again.
10
PLASMA Purification Operation(Optional)
1
Press the
The unit will
beep.
Start/Stop button.
respond with a
ENGLISH
Open the door on the remote control.
2 Press the PLASMA air purifying
operation ON/OFF button.
Operation will start when the button is PLASMA
pressed and stop when the button is
pressed again.
Set the fan speed again with door of the remote control
3 closed. You can select the fan speed in four steps-low,
medium, high or CHAOS. Each time the
button is pressed, the fan speed mode
is shifted.
11
Additional features
Sleep Mode
Press the Sleep Mode Auto button to set the To cancel theSleep Mode, press the sleep
1 time you want the unit to turn off Mode Auto button several times until the star
automatically.
( ) disappears from the operation display.
The Timer is programmed in one-hour
2 increments by pressing the Sleep Mode Auto Note: The Sleep Mode will be operated at
button 1 to 7 times. slow fan speed (cooling) or medium fan
The sleep mode is available for 1 to 7 times. To speed (heat pump only) for quiet sleeping.
alter the time period in steps of 1 hour, press
TroubleshtingpCadMcOISfyP
the Sleep Mode Button while aiming at air IN COOLING MODE OR HEALTHY
conditioner. DEHUMIDIFICATION MODE:
The temperature will automatically rise by 1°C
3 Make sure the Sleep Mode Auto LED lights up. over the next 30 minutes and by 2°C in 1 hour
for comfortable sleeping.
Time can be set only when you have pressed Press the Time Setting buttons until the
1 the Reset button. If you have just replaced the 2 desired time is set.
batteries, the Reset button should be pressed
to reset the time.
Press the Start/Stop button. Press the Timer SET button. SET
3
Note: Check the indicator
for A.M. and P.M.
Delay OFF Timer Delay ON Timer Delay OFF and ON Timer Delay ON and OFF Timer
12
Vertical Airflow Direction Control
ENGLISH
The up/down airflow (Vertical Airflow) can be Note:
adjusted by using the remote control. If you press the CHAOS swing button, the horizontal
airflow direction is changed automatically based on
the CHAOS algorithm to distribute the air in the room
evenly and at the same time to make the human body
feel most comfortable, if
enjoying a natural breeze.
as
1 Press the Start/Stop button. the unit will respond with a beep.
Open the door on the remote control. Press the Air Circulation button. Close the door on the
2 remote control. Now each time that you press the Indoor Fan the fan is
Speed Selector, speed
shifted from low to CHAOS and back to low again.
CHAOS Air Fan speed is on low. Fan speed is on medium. Fan speed is on high.
Note:
CHAOS Air economizes power consumption and prevents overcooling. The fan speed is
automatically changed from high to low or vice versa, depending on the ambient temperature.
13
Forced Operation
Operation procedures when the remote
control can't be used.
The operation will be started if the power
button is pressed.
If you want to stop operation, re-press
the button.
Power
TroubleshtingpCadMcOISfyP
button
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of
room temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, open the front panel upward and Press the power button let it be
pressed for about 3 seconds.
If you want to stop the operation, re-press the button.
Auto restart
In case the power comes on again after
power failure, Auto Restarting Operation is the function to
a
Helpful information
Fanspeed and cooling capacity.
Thecooling capacity indicated in the specification is the
value when the fan speed is set to high, and the capacity will
be lower at low or medium fan speed. High
High fan speed is recommended when you wish to cool the
room quickly.
Speed
14
Telephone Control Operation
Calling from outside, you can start the air conditioner to keep the room comfortable.
1
Even though you went out with the air conditioner on, you can turn it off using the phone
TURN ON
Dial the number which is connected with the air
conditioner.
outside.
ENGLISH
After ringing 5 times.
You can hear the "Beep" sound (if the air conditioner
is off), then press "0" "0" "7" "8" accordingly.
When using along with ARS telephone
OGM is
provided after signal sound rings four
guide
times and then "Beep"(sounds from telephone itself)
sounds so that outside recording can be done.
ON
ON Slowly press password "0" "0" "7" and "8" in order.
You can hear the "Beep Beep" sound (if the air
conditioner is on), then press "0" "0" "7" "9" accordingly.
When using along with ARS telephone
OGM guide is
provided after
signal sound rings four
times and then "Beep"(sounds from telephone itself)
sounds so that outside recording can be done.
OFF
OFF Slowly
order.
press password "0" "0" "7" and "9" in
Note:
This product works after telephone rings 5 times.
If internal user picks up the phone before 5 rings, Telephone control function does not work.
If user doesn't push the telephone button 25 seconds after beep, Telephone control function doesn't work.
When using along with ARS telephone
The numbers of response bell should be adjusted to four times if pressing "Out-of-office" button or taking
other action for automatic response.
The recording time of OGM (Outgoing Message) should be less than approximately 15 seconds.
15
Care and maintenance of the air conditioner
CAUTION: Before performing any maintenance, turn off the main power to the system.
Indoor Unit
Never any of the
Grille, Case, and Remote Control use followings:
Turn the
?
Water hotter than 40°C
system off before cleaning. To
Could cause deformation and/or
clean, wipe with a soft, dry cloth. Do not
discoloration.
use bleach or abrasives.
?
Volatile substances
NOTE: Could the surfaces of the air
damage
Supply power must be disconnected before conditioner.
TroubleshtingpCadMcOISfyP
cleaning the indoor unit.
P
owder
Gasoline
may be deformed.
After washing with water, dry well in the
3
shade.
PLASMA FILTER, DEODORIZER the PLASMA filter into the water mixed
2 Dip
FILTER(OPTIONAL) with neutral detergent, for 20~30minutes.
The PLASMA filter behind the air filters should be
checked and cleaned once in every 3 months or
3 Dry the PLASMA filter in the shade for a day
more often if necessary. (Especially, the humidity must be removed
perfectly on this parts).
4 Note the cuts of electric discharge lines.
16
Replacement of Purifying Filter(Option)
?
Recomended use period : About 2 years
1 Open
filters.
front panel and remove air 2
3
Remove air
Insert new
purifying
air purifying
filters.
filters.
ENGLISH
Air filter
Outdoor Unit
(Rear)
(Rear)
(Side) (Side)
Air intake vents Air intake
Piping Piping
vents
Drain Hose
Drain Hose
Air outlet vents
Air outlet
vents
17
When the air conditioner is not going to be used for a long time.
Operate the air conditioner on Air circulation Clean the air filter and install it in the indoor
mode (Refer to page 13) for 2 to 3 hours. unit.
(Refer to page 16 for cleaning filters.)
?
This will dry out the internal mechanisms.
TroubleshtingpCadMcOISfyP
Turn off the circuit breaker, and disconnect
the plug.
Check that the air inlet and outlet of the
Operation Tips
Do not overcool the room. Keep blinds or curtains Keep the room temperature
closed. uniform.
This is not good for the health Do not let direct sunshine enter Adjust the vertical and
and wastes electricity. the room when the air horizontal airflow direction to
conditioner is in operation. ensure a uniform temperature
in the room.
Make sure that the doors Clean the air filter regularly. Ventilate the room
and windows are shut tight. occasionally.
Avoid doors and Blockages in the air filter Since windows kept closed,
opening are
windows much reduces the airflow and lowers it is idea to open them
as as possible a good
to the cool air in the the cooling and dehumidifying and ventilate the room now and
keep room.
effects. Clean at least once in then.
every two weeks.
18
Before you call for service...
ENGLISH
following points requesting repairs or persists, please
contact your dealer or service center.
operate. ?
Has the fuse blown or has the circuit breaker
been tripped?
-
room.
warm room
conditioner.
NOTE
WATER RESISTANT: The outdoor side of this appliance is WATER RESISTANT.
The indoor side is not water resistant and should not be exposed to excess water.
19
MEMO
20
P/No.: 3828A20075G Printed in Korea
After reading this manual, keep it in a place easily accessible to the user for future reference.