Installation and operating instructions
English (GB)
Installation and operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3
English (GB)
5. Electrical connection . . . . . . . . . . . . 8
5.1 Motor protection. . . . . . . . . . . . . . . . 8
5.2 Self-regulating heat-tracing cable . . . . . . 8 http://net.grundfos.com/qr/i/96462123
6. Starting up the product . . . . . . . . . . . 9
Related information
7. Servicing the product . . . . . . . . . . . . 10 4. Mechanical installation
7.1 Maintaining the product . . . . . . . . . . . . 10 5. Electrical connection
7.2 Other documentation . . . . . . . . . . . . . 10
WARNING
Indicates a hazardous situation which, if
not avoided, could result in death or
serious personal injury.
CAUTION
Indicates a hazardous situation which, if
not avoided, could result in minor or
moderate personal injury.
4
English (GB)
SIGNAL WORD 2. Product introduction
Description of the hazard
Consequence of ignoring the warning
2.1 Product description
• Action to avoid the hazard. Incorrect operation of the pump can result
in malfunction or damage to the pump and
1.3 Notes damage to the surrounding property.
The symbols and notes below may appear in
Grundfos installation and operating instructions, Grundfos CRN MAGdrive pumps are semi-hermetic
safety instructions and service instructions. and essentially leakage-free. The motor torque is
transmitted to the pump shaft by means of magnetic
force.
Observe these instructions for explosion-
proof products.
1
A blue or grey circle with a white graphical
symbol indicates that an action must be
taken.
TM039119
1.4 Permanent magnets
CRN MAGdrive pump
WARNING
Magnetic field
Death or serious personal injury
Pos. Description
‐ Persons with pacemaker or other
magnet-sensitive medical devices must 1 Motor
not handle this pump. They must keep 2 Magnetic drive
a distance of at least 1 metre from the
product, as there is a risk of influence 3 Pump
from the magnetic fields of the pump.
‐ Credit cards, computers, watches and 2.2 Pumped liquids
other magnet-sensitive objects should The pump is suitable for pumping the following
not be kept close to the pump. liquids:
‐ The pump contains powerful magnets • aggressive or corrosive liquids
that may pose a risk of personal injury • toxic liquids
when servicing the pump. The pump • volatile liquids
must therefore only be dismantled and
assembled by authorised persons. • flammable liquids.
5
English (GB)
C CR compact Materials
J E-pump with a different maximum speed Motor stool, base plate and flanges EN
L
1.4408
K Pump with low NPSH
Motor stool, base plate, coupling and
Pump including Grundfos CUE and flanges EN 1.4408 and coupling guards in
L M
certificate cobber. Bolts, nuts and spacing pipes EN
1.4401 or higher grade
M Magnetic drive
N Flanges EN 1.4408
N With sensor
P PEEK neck ring
O Cleaned and dried
Silicon carbide/silicon carbide bearing in
P Undersize motor
Q pump and silicon carbide/silicon carbide
High-pressure pump with high-speed MGE seal faces in thrust-handling device
Q
motor
R Silicon carbide/silicon carbide bearing
R Belt-driven pump
S PTFE neck rings
S High-pressure pump
T Base plate EN 1.4408
T Thrust-handling device
6
English (GB)
Code Description 4. Mechanical installation
Silicon carbide/silicon carbide bearing in WARNING
U pump and silicon carbide/tungsten carbide Magnetic field
seal faces in thrust-handling device Death or serious personal injury
W Tungsten carbide/tungsten carbide ‐ Persons with a pacemaker or other
magnet-sensitive medical devices must
X Special version not handle this pump. They must keep
Rubber parts in pump a distance of at least 1 metre from the
product, as there is a risk of influence
E EPDM from the magnetic fields of the pump.
F FXM (Fluoraz®)
WARNING
K FFKM (Kalrez®) Falling objects
Death or serious personal injury
N CR (Neoprene)
‐ Fasten the pump securely to a solid
V FKM (Viton®) and even foundation according to the
specifications stated in the installation
Shaft seal type designation
and operating instructions.
A O-ring seal with fixed driver
H Balanced cartridge seal with O-ring The pump must not be installed in ATEX
zones 2D, 3D and M2 (dust and mining
O Double seal, back-to-back zones).
P Double seal, tandem
If the pump is installed in ATEX zones 2G
X Special version
or 3G, an ATEX-approved flow sensor
Seal face material (rotating and stationary seal must be installed to protect the pump
face) against dry running.
B Carbon, synthetic resin-impregnated
Installation and operation must comply
U Cemented tungsten carbide with local regulations and accepted codes
Q Silicon carbide of good practice.
X Other ceramics
Follow the installation and operating
Secondary seal material (rubber parts) instructions for the standard CR, CRI,
E EPDM CRN pump.
1) The temperature rise is measured on the surface of the can which is located between the pump and the magnetic drive.
7
English (GB)
CRN MAGdrive Surface temperature rise [°C] 1. Set the overload protection to the rated full-load
current (I1/1) of the motor.
Maximum 10 degrees above the
All sizes
liquid temperature 2. Start the pump, and let it run for half an hour at
the required duty point.
4.2 Connection of a sensor 3. Measure the motor current. If not possible, slowly
A pressure sensor or a Grundfos LiqTec dry-running grade down the scale indicator until the motor trip
protection unit can be fitted in the threaded hole in the point is reached.
pump head.
4. The setting of the motor protection must be 5 %
higher than this value. The highest permissible
Description Dimension setting of the motor protection is the rated full-load
current (I1/1) of the motor.
Threaded connection: RG 1/2
Max. installation length, sensor: 20 mm 5.2 Self-regulating heat-tracing cable
WARNING
5. Electrical connection Electric shock
Death or serious personal injury
WARNING
‐ More than one power source.
Electric shock
Death or serious personal injury ‐ Make sure to fix the power cable in a
‐ Switch off the power supply before you tray.
start any work on the product.
If the pump is supplied with a self-regulating heat-
‐ Make sure that the power supply tracing cable, make sure that the cable is connected
cannot be switched on accidentally. to a 1 x 220-240 V, 50 Hz power supply.
‐ Connect the pump to an external main If the pump operates with liquids below 0 °C, ensure
switch close to the pump and to a that the power supply is switched on, even if the
motor-protective circuit breaker or a pump is stopped. The power supply must not have a
CUE frequency converter. Make sure fuse size larger than 13 A.
you can lock the main switch in OFF
position (isolated). Type and
Heat-tracing-cable color codes
requirements as specified in EN
60204-1, 5.3.2. Brown, blue Power supply
Green, yellow Ground
Follow the installation and operating
instructions for the standard CR, CRI,
CRN pump.
Related information
1.1 Related instructions
8
English (GB)
6. Starting up the product 2. Close the isolating valve on the outlet side of the
pump.
DANGER
3. Loosen the vent screw in the pump head.
Explosion risk
Death or serious personal injury 4. Slowly fill the pump with liquid.
‐ Always fill the pump with liquid and
ensure that the required minimum flow 5. Tighten the vent screw when the pump has been
rate is obtained. completely filled with liquid.
WARNING 10. When liquid runs out, tighten the vent screw
Toxic liquids securely.
Death or serious personal injury
Related information
‐ Operation and servicing of the pump
9.1 Minimum flow rate
may pose a risk to the life and health of
the persons involved if the pumped
liquid is flammable, aggressive,
corrosive, toxic, or in any other way
harmful.
‐ Wear personal protective equipment.
CAUTION
Hot or cold liquids
Minor or moderate personal injury
‐ Wear personal protective equipment.
CAUTION
Hot or cold surface
Minor or moderate personal injury
‐ Make sure that no one can accidentally
come into contact with hot or cold
surfaces.
9
English (GB)
CAUTION 10
Crushing of hands
TM045693
Minor or moderate personal injury 0
‐ The pump contains powerful magnets 40 50 60 70 80 90 100 110 120 t [ C]
O
9. Technical data
10
English (GB)
10. Disposing of the product
This product or parts of it must be disposed of in an
environmentally sound way.
1. Use the public or private waste collection service.
11
Grundfos companies
Poland Switzerland
GRUNDFOS Pompy Sp. z o.o. GRUNDFOS Pumpen AG
ul. Klonowa 23 Bruggacherstrasse 10
Baranowo k. Poznania CH-8117 Fällanden/ZH
PL-62-081 Przeźmierowo Tel.: +41-44-806 8111
Tel.: (+48-61) 650 13 00 Fax: +41-44-806 8115
Fax: (+48-61) 650 13 50 Taiwan
Portugal GRUNDFOS Pumps (Taiwan) Ltd.
Bombas GRUNDFOS Portugal, S.A. 7 Floor, 219 Min-Chuan Road
Rua Calvet de Magalhães, 241 Taichung, Taiwan, R.O.C.
Apartado 1079 Tel.: +886-4-2305 0868
P-2770-153 Paço de Arcos Fax: +886-4-2305 0878
Tel.: +351-21-440 76 00 Thailand
Fax: +351-21-440 76 90 GRUNDFOS (Thailand) Ltd.
Romania 92 Chaloem Phrakiat Rama 9 Road
GRUNDFOS Pompe România SRL Dokmai, Pravej, Bangkok 10250
S-PARK BUSINESS CENTER, Clădirea Tel.: +66-2-725 8999
A2, etaj 2 Fax: +66-2-725 8998
Str. Tipografilor, Nr. 11-15, Sector 1, Cod
013714
Bucuresti, Romania
Tel.: 004 021 2004 100
E-mail: romania@grundfos.ro
96464310
ECM: 1386855
www.grundfos.com
01.2024
Trademarks displayed in this material, including but not limited to Grundfos and the Grundfos logo, are registered trademarks owned by The Grundfos Group. © 2024 Grundfos Holding A/S, all rights reserved.