Professional Documents
Culture Documents
New Developments in Regulators 1
New Developments in Regulators 1
Gleb Maksimov
3/17/2011
Mooney® Slam Shut
1” Mooney®
Flowgrid®
Slam Shut 2” Mooney®
Regulator and Flowgrid®
Series 41D Slam Shut
Controller Regulator and
series 50D
Controller
1
Mooney® Slam Shut
Examples of 2” units, both shown with the Series 50D (Dual Function)
Controller
2” – 4” Controllers
Series 50 Single
Function Controller Series 50D Dual
For under pressure OR Function Controller
over pressure protection For under pressure AND/OR
over pressure protection
(Dual Sense Ports Available) 3
Mooney® Slam Shut
4
Mooney® Slam Shut - Features of the 1” design
5
Mooney® Slam Shut - Features of the 2” – 4” design
6
Mooney® Slam Shut
1” and 1 ¼” Design
• Linear actuation.
• Unique body casting and unique
controller.
• Can not be retrofitted to existing
Flowgrid Regulators
• Multiple connection options
NPT, SWE and RF Flange
(up to Class 300 only)
• Available with a Single or Dual
Function Controller
(Series 41 or 41D).
7
Mooney® Slam Shut
2” – 4” Design
• Same modular design as existing
Flowgrid® models.
• Multiple
Flange Options
(up to Class 300 only)
*exceptions include flangeless, and
type A.
8
Mooney® Slam Shut Retrofit
• 2”through 4” Flowgrid ®
9
Mooney® Slam Shut - Set Point Ranges
1” Sizes.
2” – 4” Sizes.
10
Mooney® Slam Shut Operation
The spring
then forces
the linear
plug to close
Upset
condition is
sensed, latch
mechanism
is retracted
11
Mooney® Slam Shut Operation
Upset
Condition is
Sensed
Normal
Pressure Operating
slowly
returns Condition
increases,
to normal nearly reaching the trip pressure
13
Mooney® Slam Shut - False Trip Prevention
14
Mooney® Slam Shut - False Trip Prevention
15
Mooney® Slam Shut Resetting
After an upset condition has occurred
• Close
Open the
••Reset block Shuttowith
valves
Slam restore flow.
common * Reset lever is also
• upstream
The Slam
hand Shutdownstream
toolsand is once accessible on the opposite
again providing
• Then downstream
equalize the line side of the Slam Shut.
pressure protection
pressure
16
Mooney® Slam Shut Resetting
17
Mooney® Slam Shut - Standards & Certifications
Designed to EN-14382
In process of obtaining EN-14382 certification.
ASME B16.34
18
2” Flowgrid AC Port Regulator
19
2” Flowgrid AC Port Regulator
• Cg of 1970 meets or
exceeds competitors
capacity.
• Low Differential
20
2” Flowgrid AC Port Regulator
21
3D Model Library Overview
•220+ 3D models
• Comprised of Mooney® and Flexflo® regulators
• Our library is setup in such a way that the customer can add, remove,
or change the layout however they need
Saves time/money
Questions?