Regulation and Control Division

Mooney® New Products

Gleb Maksimov
3/17/2011
Mooney® Slam Shut

Dresser, Inc. introduces the


Mooney® Slam Shut
Available with or without the Flowgrid® Regulator
Patents Pending

1” Mooney®
Flowgrid®
Slam Shut 2” Mooney®
Regulator and Flowgrid®
Series 41D Slam Shut
Controller Regulator and
series 50D
Controller

1
Mooney® Slam Shut

Examples of 2” units, both shown with the Series 50D (Dual Function)
Controller

Mooney® Flowgrid® Mooney® Slam Shut


Slam Shut Regulator
2
Mooney® Slam Shut

2” – 4” Controllers

Series 50 Single
Function Controller Series 50D Dual
For under pressure OR Function Controller
over pressure protection For under pressure AND/OR
over pressure protection
(Dual Sense Ports Available) 3
Mooney® Slam Shut

2”, 3” and 4” Shut Off Valve Assemblies

4
Mooney® Slam Shut - Features of the 1” design

• Easy to maintain; only two bolts required to remove


entire Slam Shut assembly
• Resistant to sticking due to freezing water or debris
in pipeline
• Excellentperformance and accuracy across a large
pressure range with a simple spring change.
• External visual indicator to show when unit is
tripped.
• Easy to reset; only three caps need to be removed
for complete reset.
• No pressure differential requirements for full shutoff.

5
Mooney® Slam Shut - Features of the 2” – 4” design

• Bubble tight shutoff with floating flapper valve


design.
• Water tight for below grade vault installations.
• Can be ordered with or without an integral
Flowgrid® regulator.
• Can be retrofitted to existing 2” – 4” Flowgrid®
regulators.
• Resistant to vibration and inlet pressure
variation eliminating nuisance trips.
• Available with over pressure protection, under
pressure protection, or a combination of both.
• High Accuracy

6
Mooney® Slam Shut

1” and 1 ¼” Design
• Linear actuation.
• Unique body casting and unique
controller.
• Can not be retrofitted to existing
Flowgrid Regulators
• Multiple connection options
NPT, SWE and RF Flange
(up to Class 300 only)
• Available with a Single or Dual
Function Controller
(Series 41 or 41D).

7
Mooney® Slam Shut

2” – 4” Design
• Same modular design as existing
Flowgrid® models.

• Can be retrofitted to existing


Flowgrid® Regulators
(up to Class 300 only)

• Multiple
Flange Options
(up to Class 300 only)
*exceptions include flangeless, and
type A.

8
Mooney® Slam Shut Retrofit

• 2”through 4” Flowgrid ®

regulators can be retrofitted


with the Slam Shut
Retrofit Kits Include;
•Body Seal
•Shutoff Valve Assembly
•Fasteners
•Series 50 or 50D Controller

9
Mooney® Slam Shut - Set Point Ranges
1” Sizes.

2” – 4” Sizes.

10
Mooney® Slam Shut Operation

Slam Shut Operation (1”)

The spring
then forces
the linear
plug to close

Upset
condition is
sensed, latch
mechanism
is retracted

11
Mooney® Slam Shut Operation

Slam Shut Operation (2” – 4”)


Over
ValvePressure
Normal or Under Pressure
Operation
has Slammed Shut
Condition Occurs

Upset
Condition is
Sensed

Actuator releases Upstream


Causing Pressure Assists
the Flapper
the Pawl Lever in Valve
Sealing
to the Flapper
Close 12
Mooney® Slam Shut - False Trip Prevention

Normal
Pressure Operating
slowly
returns Condition
increases,
to normal nearly reaching the trip pressure

Latch Mechanism Controller


remains stationary begins to vent

13
Mooney® Slam Shut - False Trip Prevention

In this situation, the design of our competitor’s latching


mechanism may not reseat itself and is now susceptible to
false trip due to vibration.

14
Mooney® Slam Shut - False Trip Prevention

Dresser’s snap acting latch has no intermediate position.


This unique feature prevents future false trips!

15
Mooney® Slam Shut Resetting
After an upset condition has occurred
• Close
Open the
••Reset block Shuttowith
valves
Slam restore flow.
common * Reset lever is also
• upstream
The Slam
hand Shutdownstream
toolsand is once accessible on the opposite
again providing
• Then downstream
equalize the line side of the Slam Shut.
pressure protection
pressure

16
Mooney® Slam Shut Resetting

Resetting the 1” is similar with


the exception that the reset
motion is linear vs. rotary.
After the upstream and downstream
block valves are closed, remove the
bleed cap and depress the bleed valve
with a screwdriver to equalize the line
pressure
With the reset shaft held down,
depress the reset pin contained
beneath the reset cap.
A simple tool (such as a screwdriver)
is inserted in the reset shaft and is
then used as a handle to pull the
shaft downward.

17
Mooney® Slam Shut - Standards & Certifications

Designed to EN-14382
In process of obtaining EN-14382 certification.

ASME B16.34

18
2” Flowgrid AC Port Regulator

•Dresser, Inc. introduces the 2” Flowgrid AC Port regulator to


it’s Flowgrid family.

•This valve combines a 2” body with a 3” port producing a


very strong piping installation with low regulator outlet
velocity.

19
2” Flowgrid AC Port Regulator

• Cg of 1970 meets or
exceeds competitors
capacity.

• Capacity is second only to


that of the Dual LP in the
2” Flowgrid product line.

• 100% Throttle Plate only.

• Low Differential

20
2” Flowgrid AC Port Regulator

• Soft goods consist of standard 2”


and 3” Flowgrid components.

• Available with RF Flange


(Class 150, 300 and 600)
SWE, NPT, BWE (Class 600).

• Same top entry design as existing


Flowgrid models for ease of
maintenance.

21
3D Model Library Overview

•220+ 3D models
• Comprised of Mooney® and Flexflo® regulators

•Alsocontains a 2D library and a color PDF index for


easier choice of model

CONFIDENTIAL: FOR INTERNAL USE ONLY 22


How Our Library Is Setup

• Our library is setup in such a way that the customer can add, remove,
or change the layout however they need

• We have supplied the most common layouts for ease of use

• Models are compatible with Metric and Standard

CONFIDENTIAL: FOR INTERNAL USE ONLY


Customer Benefits

Saves time/money

• Saves hours of design time

• Convenient access from one source

• More realistic/more accurate drawings


• With Dresser models in place, piping layouts are easier to convey to technicians
in the field

• Receive updates about new products

CONFIDENTIAL: FOR INTERNAL USE ONLY 24


3D Model Library

Questions?

CONFIDENTIAL: FOR INTERNAL USE ONLY 25


Mooney® Slam Shut
Product Launch