You are on page 1of 2

Guideline: FX-B/GX-B/GP-B/FP-B from serial number 8669 00001 Design State FX-18-01 EN

Wash programmes/wash times E11 X 12 : 6 Reserve A11 1A3 X 1 : 2 Softener valve drain Y10.3
GX GP FX FP FXCV FPCV Bäko& FXNB FXTD E12 X 12 : 7 Reserve A12 1A3 X 1 : 3 Softener valve boiler Y10.2
1 Short 60 90 80 100 100 90 E13 X 13 : 2 Reserve A13 2A3 X 1 : 1 Reserve
2 Standard 90 180 150 190 190 180 X E14 X 13 : 3 Reserve A14 2A3 X 1 : 2 Reserve
3 Intensive 120 250 250 Austria E15 X 15 : 1/2 Hall sensor S15 A15 2A3 X 1 : 4 Reserve
4 ECO 170 with steam E16 X 17 : 2 Reserve A16 3A4 X 1 : 1 Drying power supply unit
5 cold 120 120 AE1 X 8 : 1/2 Boiler temperature B1 A17 3A4 X 1 : 2 Topdry heating E3 / K3
6 Intensive with 360 360/no AE2 X 8 : 3/4 Wash tank temperature B2 A18 3A4 X 2 : 3 Topdry M6
water exchange detergent
AE3 X8:6 Boiler pressure B3 A19 4A4 X 1 : 1 ROI pump M12
7 Continuous X X
AE4 X8:9 Wash tank pressure B4 A20 4A4 X 1 : 2 ROI valve Y8
8 Cutlery 360 360 with steam
AE5 X7:9 Turbidity B5 A21 4A4 X2 : 1 Reserve
9 Hygiene X X/off X /X2:3
Basic cleaning X X AE6 X 14 : 4/5 Temperature wash chamber A22 5A5 X 1 : 1 PFR contact 1
Descaling* X X B6/ Topdry / X1 : 2
Coffee cups X A23 5A5 X 2 : 1 PFR contact 2
/X2:2
* only possible in the service menu *The wash pump can only be actuated via A24 5A5 X 3 : 1 PFR contact 3
Display explanation diagnosis mode / soft start mode
/X3:2
**Actuate the filling valve via the menu item AA1 A1 X 7 : 10 LED turbidity sensor
diagnosis boiler filling on machines with AA2 A1 X 15 :3/4 PWM drying M6
softener
AA3 Soft start M1
Machine numbers
Type Maschine El. A Maschine El. A Maschine El. A
➀ CANCEL button: With this button the machine can be switched into off mode at any time. machine El. C
Type
machine El. C
Type
machine El. C
Active programmes are aborted. After switch off, however, the machine is not voltage 101 GXC-11B ABCD 151 FP-10B / 3P 6,8kW 14,2A A 505 FX-B-SEF SEF-18/068 A
free! Pressing and holding the button for 5 sec takes you to the login level. 101 GX-10B ABCD 152 FP-10B / 1P 3,3kW 14,2A C 506 FX-B-SEF SEF-18/069 A

➁ ON/OFF button: Pressing this button switches the machine on. In addition, the button 102 GXCS-11B ABCD 153 FP-10B / 1P 4,7kW 20,3A D 507 GX-B-SEF SEF-18/069 A

indicates the current operating status through different colours. GREEN (increasing sec- 102 GXS-11B ABCD 154 FPS-10B / 3P 6,8kW 14,2A A 508 FX-B-SEF SEF-18/070 A

tors) = machine is being filled and is heating. GREEN (permanent) = machine is ready for 103 GXCROI-11B ACD 155 FPS-10B / 1P 3,3kW 14,2A C 509 FX-B-SEF SEF-18/058 A

operation. BLUE (sectors) = wash programme running. RED (permanent) = critical fault.
104 GXC-80B A 156 FPS-10B / 1P 4,7kW 20,3A D 510 FX-B-SEF SEF-18/059 AB
105 GXC-90B AC 199 Prüfstand / internal 511 FX-B-SEF SEF-18/061 / 085 / 075 AB
GREEN/RED (alternating) = uncritical failure. Pressing and holding (3 sec.) activates the 106 GXCROI-90B AC 201 GC-10B ABC 512 FX-B-SEF SEF-18/097 AB
automatic drain and self-cleaning programme and the machine switches off afterwards. 111 GP-10B (3P 6,8kW) A 202 GC-10B D 513 FX-B-SEF SEF-18/100 A

➂ DISPLAY: Message 111 GPC-50B (3P 6,8kW) A 203 GCROI-10B ABC 514 FX-B-SEF SEF-18/098 A
112 GP-10B (1P 3,3kW) C 204 Nicht verwendet / not used 515 FX-B-SEF SEF-18/098 C

➃+➅ Display navigation buttons/display setting buttons 112 GPC-50B (1P 3,3kW) C 205 GCS-20B ABC 516 FX-B-SEF SEF-18/098 D
113 GP-10B (1P 4,7kW) D 206 GCS-20B (1P/5,6kW) D 517 GP-B-SEF SEF-18/099 A
➄ Display navigation buttons menu level change/acknowledgement (save but- 113 GPC-50B (1P 4,7kW) D 207 GC-90B ABC 518 GP-B-SEF SEF-18/099 C
ton) /return/fault acknowledgement 114 GPS-10B (3P 6,8kW) A 208 Nicht verwendet / not used 519 GP-B-SEF SEF-18/099 D

Display test By simultaneously pressing and holding the buttons ➃ + ➄ + ➅ (5s) you can skip
115 GPS-10B (1P 3,3kW) C 209 GCROI-90B AC 520 GX-B-SEF SEF-18/108 A

➃+ ➄+ to BAE test mode. The test starts with 2 acoustic signals and ends after approx. 1
116 GPS-10B (1P 4,7kW)
117 GPCROI-10B (3P 7,0kW)
D
A
210 Nicht verwendet / not used
241 GCP-10B ABC
521 FP-B-SEF SEF-18/111
522 GP-B-SEF SEF-18/111
A
A
➅ / reset minute with 2 acoustic signals. 118 GPCROI-10B (1P 3,5kW) C 242 GCP-10B D 523 FP-B-SEF SEF-18/112 D
display test 119 GPCROI-10B (1P 4,9kW) D 243 GCPROI-10B AB 524 GP-B-SEF SEF-18/114 A
120 GPC-60B D 243 GCPROI-10B (S08=1) D 525 GX-B-SEF SEF-18/140 A
Login PINs 121 FX-10B ABCD 299 Prüfstand / internal 526 FX-B-SEF SEF-18/159 A

PIN 1111 Chef login General settings: Language/date/time/temperature unit. Display message: 121 FXL-10B ABCD 301 CareS-10B (Q1 2019) A 527 FP-B-SEF SEF-19/004 A

For Chef Customer Programme representation/brightness/contrast. Acoustic signal. Chemical 122 FXS-10B ABCD 302 CareS-10B (Q1 2019) C 528 FX-B-SEF SEF-18/078 ABCD
ABCD
login menu settings: Detergent dosing/rinse aid dosing/chemical hoses. External water 122 FXLS-10B ABCD 303 CareS-10B (Q1 2019) D 529 FXS-B-SEF SEF-18/078

treatment system: setting/resetting counters, remaining water quantity.


123 FXLSBäko-10B ABCD 304 Care-11B (Q1 2019) A 530 GX-B-SEF SEF-18/064 ABCD
124 FX-13B A 305 Care-11B (Q1 2019) C 531 FX-B-SEF SEF-19/078 ABCD
Degree of hardness. Drying assistant. Operating/hygiene data. Timer. 125 FXS-15B ABCD 306 Care-11B (Q1 2019) D 532 FP-B-SEF SEF-19/112 A
PIN 9999 External Detergent / rinse aid concentration, hose filling, actuation deter- 126 FX-40B (2P 4,3kW) B 307 Care-90B (Q1 2019) A 533 GP-B-SEF SEF-19/112 A

for service chemicals gent/rinse aid dosing. Detergent/rinse aid detection. Signal in 127 FX-40B (3P/7,7kW 3P/5,9kW) AC 308 Care-90B (Q1 2019) C 534 FP-B-SEF SEF-19/135 A

login case of chemical deficiency. Detergent/rinse aid density 128 FX-80B FX-B-SEF-18/046 A 309 Care-90B (Q1 2019) D 535 GP-B-SEF SEF-19/135 A
128 FXL-81B FX-B-SEF-18/047 B 401 Nicht verwendet / not used 536 FX-B-SEF SEF-20/011 A
PIN 0022 Service Parameters. Activate/deactivate programmes. Reset service 129 FX-B-SEF SEF-18/049 AC 402 Nicht verwendet / not used 537 GX-B-SEF SEF-18/068 A
menu interval. Software version/update. Select machine type. Diagnosis 130 FXSTD-10B / 3P 6,8kW A 501 FX-B-SEF SEF-18/062 A 601 GCP-B-SEF SEF-20/031 A

mode. Unlock in case of salt deficiency. Reset fault memory/des- 131 FXSTD-10B / 1P 2,7kW C 502 FX-B-SEF SEF-18/063 / 067 A 602 GC-B-SEF SEF-20/056 ABC

caling programme/change info/service display/Vapostop Top Dry 132 FXSTD-10B / 1P 4,7kW D 503 FX-B-SEF SEF-18/064 / 065 / 081 A 603 GC-B-SEF SEF-20/056 D

unlock (only if S54 to „2“)


504 FX-B-SEF SEF-18/066 A

Important switching functions


Dosing units chemicals
S1 = hood start 0 = function off/1 = function on
Profi dosing units Profi dosing units
S4 = thermostop wash tank: The thermo stop wash tank for the cold program was
Detergent dosing unit: 01-515268-002 Rinse aid dosing unit: 01-515269-006 (important on machines with changed. The switching function S4 was enhanced for
Flow rate: 3.0l/h (50Hz) 3.6l/h (60Hz) Flow rate: 1.6l/h cold rinse programmes) this. With switch position S4=2 (previously 1 and thus
Hose inside as 01-515268-012 black Hose inside as service 775608-003 always active), the thermostop tank is only carried out
service kit: carrier plate kit: during the cold programmes and during the first wash
01-515268-020 programme after a cold programme.
yellow carrier plate S11 = softener 0 = function off/1 = function on
Parameters chemicals monitoring (login PIN 9999) S19 = external demineralisation 0 = function off/1 = function on
S21 Signal in case of chemical deficiency S20 = connected load / 1 = Connection value A207; 2 = Connection value A208
boiler capacity 3 = Connection value A209; 4 = Connection value A210
0 = Signal in case of chemical deficiency "0" (default)
S21 = signal in case of chemical 0 = negated (default) / 1 = not negated
1 = Signal in case of chemical deficiency "1"
deficiency
S65 Detergent/rinse aid detection
S23 = actuation detergent pump 0 = no actuation; 1 = actuation Hobart
0 = No detection active (default) M4 2 = actuation parallel to rinse pump M2
1 = Detergent and rinse aid detection active 3 = actuation parallel to wash pump M1
4 = actuation parallel to filling valve Y1
2 = detergent detection active
S24 = actuation rinse aid pump M3 0 = no actuation; 1 = actuation Hobart
3 = rinse aid detection active
2 = actuation parallel to the rinse pump M2
Diagnosis mode inputs/outputs (analogue/digital) 3 = actuation parallel to wash pump M1
4 = actuation parallel to filling valve Y1
In- Terminal: Assignment Out- Terminal: Assignment soft start/
puts Pin (A1) puts Pin diagnosis S47 = turbidity sensor response 1 = Level1<1.75V / Level2<1.50V / Level3 < 1.00V
2 = Level 1 < 2.25V / Level2 < 2.00V / Level 3 < 1.75V
E01 X 7 : 1/2 Door switch S1 A01 A1 X 4 : 1 Wash pump M1* 3 = Level 1 < 2.75V / Level2 < 2.50V / Level 3 < 2.00V
E02 X 7 : 5/6 Impeller sensor S2 A02 A1 X 4 : 3 Reserve 4 = Level 1 < 3.25V / Level2 < 3.00V / Level 3 < 2.75V
E03 X 7 : 7/8 Strainer switch S3 A03 A1 X 4 : 4 Detergent dosing pump M4 S50 = Demo programme: If S50 on 1, then 3 further log-ins are possible:
E04 X 10 : 1/2 Salt deficiency S4 A04 A1 X 5 : 3 Rinse aid dosing pump M3 1001 Commissioning and demo mode
E05 X 12 : 2 Reserve A05 A1 X 4 : 6 Filling valve Y1** 2001 Here you can select all error message texts that are displayed to the outside.
E06 X 9 : 1/2 Detergent deficiency S6 A06 A1 X 3 : 5 Drain pump M5 2002 Here you can select all error message texts that are shown in the fault memory.
S51 = service level for all analogue 0 = function off/1 = function on
E07 X 9 : 1/3 Rinse aid deficiency S7 A07 A1 X 4 : 5 Rinse pump M2
values on display
E08 X 12 : 1/2 Leakage sensor (ROI) S8 A08 A1 X 5 : 2 Boiler heating E1 / K1
S52 = permanent temperat. display 0 = function off/1 = permanent temperatur off/menu
E09 X 12 : 1/4 Low pressure (ROI) S9 A09 A1 X 6 : 2 Tank heating E2 item/2 = permanent temperatur on
E10 X 12 : 5 Reserve A10 1A3 X 1 : 1 Softener valve salt dosing S53 = turbidity sensor 0 = function off/1 = function on
Y10.1

© HOBART GmbH, Offenburg GL-22772-001-EN / 07.09.2020 Page 1


Guideline: FX-B/GX-B/GP-B/FP-B from serial number 8669 00001 Design State FX-18-01 EN
S54 = Zeo Drying/Vapostop 0 = TopDry conditionally off (heating switches nevertheless) 029 Programme interruption by door/hood switch, opening of door/hood (E01=0)
1 = TopDry function fully on  Programme is interrupted.
2 = TopDry function fully off
030 D
 oor/hood switch (E01) does not switch E01 within 20 wash programmes ≥ opened once
S63 = signal sensor 0 = function off/1 = function on
 Filling valve (A05) remains actuated.
S65 = inputs chemicals monitoring 0 = function off / 1 = detergent + rinse aid on / 031 Filling monitoring by impeller sensor, only on S18 = 1 and T84 ≠ 0
2 = only detergent /3 = only rinse aid
 Filling valve (A05) remains actuated
S67 = prompt for hygiene programme 0 = function off/1 = function on
032 Filling monitoring by measuring the water level in the boiler, voltage change at AE3
S68 = strainer monitoring 0 = function off/1 = function on ≤ A59 after T84
S69/70/71 Switch for floating contacts on additional PCB  Filling valve (A05) remains actuated
S72 = language 1 = German/ 2 = English/ 3 = French….. 033 Filling valve monitoring, A05 ≥ T122 at S82 = 0 or > T174 at S82 = 1
S73 = prompt initial start-up 0 = no prompt for initial start-up/  Machine is switched off / display remains switched on
1 = prompt 034 Service interval, only if S66 = 1; counter C46 ≤ 0
S79 = mask menu item service 0 = service contact address is displayed in case of fault mes-  Is shown on the display when the machine is switched on
hotline sages and at info level / 1 = no service number and info level
035 Strainer not inserted, S68 = 1, E03 for ≥ 5 seconds "0"
S82 = reverse osmosis 0 = function off/1 = function on
 A wash programme is aborted and the machine switched to standby mode. A filling pro-
S83 = soft start 0 = function off/1 = function on gramme is interrupted. The display remains switched on. The fault is only entered in the fault
S89 = temperature monitoring in 0 = no entry in the hygiene report in case of tempe- memory if the door is closed and a fill, wash or pump-out programme is active !!!
the hygiene report rature shortfall 036 Detergent deficiency: if E06 / S06 for 900s at "1"
1 = Wash and rinse temperature shortfalls are logged in for float switch: S21=0 / S65=1 and E06=1
the hygiene report  After acknowledgement without eliminating the deficiency, the message reappears after 10 cyc-
2 = Wash and rinse temperature shortfalls are logged in les. The message appears immediately after machine OFF/ON. The machine remains in active
the hygiene report and message 070/071 mode. Top up detergent.
S134 WLAN 0 = aus / 1 = ein 037 Rinse aid deficiency: if E07 / S07 for 900s at "1"
S137 WLAN in customer menu 0 = aus / 1 = ein for float switch: S21=0 / S65=1 and E07=1
 After acknowledgement without eliminating the deficiency, the message reappears after 10
Selected possible fault messages cycles. The message appears immediately after machine OFF/ON. The machine remains in
Possible fault messages 001 Temperature boiler sensor exceeded, AE1 is ≥ 115°C active mode. Top up rinse aid.
Machine reaction  Machine is switched off / display remains switched on 038 Input voltage of control too high, voltage ≥ 10 seconds > 253V
002 Temperature boiler sensor undercut, AE1 is ≤ 0°C  Machine is switched off
 Machine is switched off / display remains switched on 039 Hood/door open during filling programme, S13 = 1 active
003 Boiler thermostop in filling programme exceeded, S7 = 2/3, AE1 is not reached in T54  The filling programme is interrupted as long as the door is open
 Filling program is continued. Monitoring of boiler heating continues. 040 INTENSIVE machine care prompt, error message at C95 ≤ 0 / S67 = 1
004 Boiler thermostop in wash programme exceeded, S7 = 2/3, AE1 is not reached in T55  Is shown on the display when the machine is switched on/filling programme starts 10s later
 Wash programme is continued. 041 Capacity external water treatment exhausted, counter reading C44 ≤ 0 / S19 = 1
005 No boiler heating enabling, heating enabling level not reached for more than T143, and boiler  Display in standby mode after every wash programme. Can be masked for 10 washing
heating request is pending operations by acknowledging. (See message 037)
 Boiler level AE3 is checked. If it is within a valid range (no fault code 014 or 015), the boiler is topped up to the 042 Shelf life of osmosis pre-filter exceeded, remaining time A122≤0 and S82=1/ S19=1
set-point value. An active regeneration may not be interrupted by this.  Display in standby mode after every wash programme. Can be masked for 10 washing
006 Temperature tank sensor exceeded, AE2 is ≥ 115°C operations by acknowledging.
 Machine is switched off, display remains switched on 043 Regenerating salt depleted, S11 = 1 and S14 ≠ 0, input E04 = 1 for ≥ T134
007 Temperature tank sensor undercut, AE2 is ≤ 0°C  Display in standby mode after every wash programme. Can be masked for 10 washing
operations by acknowledging. (See message 037)
 Machine is switched off, display remains switched on
044 Critical fault: salt deficiency, reverse counter C8 ≤ 0 and input E04 = 1 / S11 = 1 / S14 = 2/3
003 Tank thermostop in filling programme exceeded, AE2 is not reached in T57
 Can be masked for one washing operation by acknowledging
 Filling programme is aborted. The machine goes into standby mode.
045 Lock the machine for salt deficiency, reverse counter C10 ≤ 0, E04 = 1, S11 = 1/S14=3
009 Tank heating thermostop in wash programme exceeded, AE2 is not reached in T57
 An already active wash or filling programme is completed. The message is then shown on the
 Wash programme is aborted. The machine goes into standby mode. display in standby mode
010 No tank heating enabling, AE2 + AE4 undercut during the thermostop time 1/2 (T57/T58) 047 fault USB
 No reaction  Outputs are switched off
011 Temperature wash chamber sensor exceeded, S85 on 1, AE6 is ≥ 115°C 048 USB flash drive not detected
 Machine is switched off, display remains switched on  Error is triggered during the transfer of the hygiene report and the firmware update
012 Temperature wash chamber sensor undercut, S85 on 1, AE6 is ≤ 0°C 049 Communication fault STE with BAE
 Machine is switched off, display remains switched on  Machine is switched off
013 Thermostop wash chamber in wash programme exceeded, the setpoint tempera- 050 Zero point adjustment pressure transmitter B3 failed, A56 > 0.06V or A56 < -0.06
ture at AE6 was not reached within the thermostop time 3 wash chamber T59.
 Acknowledgement -0.06V ≤ A56 ≤ 0.06V, no restriction
 The thermostop is aborted, the wash programme completed.
051 Zero point adjustment pressure transmitter B4 failed, A96 > 0.06V or A96 < -0.06
014 Total value pressure sensor boiler exceeded, AE3 is ≥ 4.5 V
 Acknowledgement -0.06V ≤ A96 ≤ 0.06V, no restriction
 Machine is switched off, display remains switched on
052 Water level control in wash tank failed, AE4 is > A92
015 Total value pressure sensor boiler undercut, AE3 is ≤ 0.30 V
 Machine is switched off (off mode). The display remains switched on. A06 is switched on
 Machine is switched off, display remains switched on until the voltage at AE4 < A91
016 Total value pressure sensor tank exceeded, AE4 is ≥ 4.5 V 057 Fill level wash tank too low at programme start, A97 > 0.00; A79 is ≤ A97; S100 = 1
 Machine is switched off, display remains switched on  The wash programme is stopped. It is followed by a filling programme. The started wash
017 Total value pressure sensor tank undercut, AE4 is ≤ 0.30 V programme is then continued after the filling programme.
 Machine is switched off, display remains switched on 063 Fault - osmosis system water supply pressure too low
018 Overflow protection pressure sensor tank, AE4 is ≥ A92  Check water supply
 Machine is switched off, display remains switched on. A06 (M5) is switched on until the 064 Fault - osmosis system is leaking
voltage at AE4 ≤ A91.  Close water supply, check leakage sensor
020 Filling programme monitor pressure sensor tank, AE4 ≤ (A95 + the saved initial value). On 065 Drying heater restricted or faulty
starting the filling programme, the voltage value at AE4 is saved internally. (no temperature change in the Topdry unit)
After a number of C58 rinsing steps, the voltage at AE4 ≤ A95, thus a fault is triggered. S54 is then "2" (drying without function, procedure see service manual chapter
 Machine is switched off, display remains switched on 8.11.7 ff.)
021 Wash tank draining in pump-out programme pressure sensor tank, AE4 ≥ A93 066 Drying fan motor restricted or faulty (speed smaller than 50Hz)
 Machine is switched off, display remains switched on S54 is then "2" (drying without function, procedure see service manual chapter
022 Wash tank draining during wash programme pressure sensor tank, A84, A85, 8.11.7 ff.)
A72, A73, A74, A75 is not reached within T73 067 Maximum duty cycle of the drying heater exceeded
 Machine is switched off, display remains switched on (if E3 is still active after 110s)
024 Analogue current of turbidity sensor exceeded, current AA1 > 20mA S54 is then "2" (drying without function, procedure see service manual chapter
8.11.7 ff.)
 The AA1 is switched off. No machine reaction
068 Temperature drying heater sensor exceeded (temperature at B6 >=140°C)
025 Analogue current of turbidity sensor undercut, current AA1 ≤ 4mA
S54 is then "2" (drying without function, procedure see service manual chapter
 The AA1 is switched off. No machine reaction 8.11.7 ff.)
026 Calibration value deviation turbidity sensor exceeded, deviation AA1 ≥ +/- A128 % 069 Temperature drying heater sensor undercut (temperature at B6 <=0°C)
of the saved calibration value A125.
S54 is then "2" (drying without function, procedure see service manual chapter
 The AA1 is switched off. No machine reaction. 8.11.7 ff.)
027 Calibration of turbidity sensor failed, calibration within T139 failed. 070 Temperature in the wash programme not reached only if S89 at "2"
 The AA1 is switched off. No machine reaction. 071 Temperature in rinse programme not reached only if S89 at "2"
028 Calibration of turbidity sensor failed repeatedly C6 ≤ 0
 The AA1 is switched off. Further fault messages and description are listed in the service manual/troubleshooting list for
service technicians. Messages not listed are not active, e.g. 019.

© HOBART GmbH, Offenburg GL-22772-001-EN / 07.09.2020 Page 2