You are on page 1of 1

1.

50M HEIGHT BOUNDARY WALL S


VACANT LAND W
39.02M
P
ADEE
L.P TO PR

1.5
L.P
L.P
39.58 E
N
5A
N.H -

12.86
R4
LAND

20.29
.00

9.93
1314
SPACE FOR 1301

12.60M
SCAPING

M
STORAGE OF 5KGS
E.V-1,2,3,4

12.86
1313

6.0
LPG CYLINDER

71
1300 13
15 VACANT LAND

9.
VACANT LAND
1325 1323
1316
SITE FOR I.O.C.L R/O

20.29
L.O.C

1.50 3.50 PLOT NO - 1314 (P), 1315(P)


.L
SITE FOR I.O.C.L R/O

62
13
0.25 M X 0.25 HEIGHT PLOT NO - 1314(P),1315(P)

20.95
KHATA NO. 135,166 17

11.
ROAD
DRIVE WAY

2.50
KHATA NO - 135,166

M
13
GUARD WALL LEV.
18
13
19 22.20
13
L.P 20

30.72
13
FRONT ELEVATION 13
21

Y
5.26 32

20 KL HSD TANK

20 KL HSD TANK

TO REFINER
PE
T-2 T-1 T-1T-4

20 KL HSD TANK

20 KL HSD TANK
T-3 T-3 T-2 WATER TAP
3.50

20 KL MS TANK

20 KL MS TANK
POINT

20 KL XP TANK

20 KL XP TANK

O
MH MH MH MH MH MH MH 1327

22.70
S
2%
71

D.G
8.25M
V V V V V V S
7.80M PLOT LIMIT

9.
S S S SS S S SS S S SS V
F D D
F F D D
F F D F DF D

3.20
R4 R4

14.80
MOUZA MAP

RECEPTION
CUSTOMER
.00 .0

TECHNICIAN
0.90 4.00 0.90
0 DRIVE WAY

3.0 X 1.80
LOUNGE
1.6 X 3.0
26.70

3.0 X1.80

3.0x1.75
LUBE D

PARTS
SPARE
12.24 SCALE - NTS 54.73M

ROOM
ROOM 2.90

D3
D3
E.V-1,2,3,4 E.V-1,2,3

2.0 X 1.68M

2.0 X 1.68M
TOILET

TOILET
PLOT LIMIT

8.00

6.60

L.C

2% SLOPE

2% SLOPE

2% SLOPE

2% SLOPE
S.T
APPROVED FACILITY

2.50 X 3.50M
OFFICE D

ROOM
ELEC.
FIRE EXSITINGUISHER

37.50M
20
ROOM

S.P

34.30M
12.

SAMPLE

4.00
MPD - 2 MPD - 1

4.80
MS/HSD XP MS/HSD XP CONTAINER RACK
SAMPLE
PROPOSED FACILITY
0.5

3.00 X 3.50 M
CONTAINER RACK

11.50M
1.50M HEIGHT 0 13.52

14.75M
F.G.W

SALES
ROOM
1.00
BOUNDARY WALL
19.68 S.B
7.50
F.E
19.60 DELETED FACILITY 1X1.0M Ø HUME PIPE CULVERT NP-4 1.0M WIDE OPEN DRAIN

17.75M
DRAIN 1X1.0M Ø HUME PIPE CULVERT NP-4 DRAIN

3.65 X 8.0

3.65 X 8.0
1.65 CANOPY

D1
22.20M

BAY - 2
BAY - 1
10.25 COLUMN

D1
MS STRUCTURAL FLANK WIDE 1.5M

3.0 X 3.50M
CANOPY

OFFICE
ROOM
2.20

14.0M X 18.0M

F.G.W
L.P

18.00

10.00
ROAD

9.00
C/L OF ROAD TO REFINERY
2% SLOPE

D1
DEVIDER WIDE 2.0M

30.72M
D1
4.25M X 2.50 M

7.50M
SHOP AREA
4.0M X 7.0M
LUBRICANT

3.0 X 3.50M

DEALERS
TO N.H 5A
18.52M

ROOM
F.G.W1
OFFICE

R.S
F.G.W2

MPD - 4 MPD - 3 1.0 C/L OF ROAD ROAD

0.90M

0.90M
HSD HSD 3.68
FLANK WIDE 1.5M
C C A.T.M-1 STORE

3.00
DRIVE WAY
9.75

3.50 X 2.50M 3.50 X 2.50M 1.3


DRIVE WAY 1.00
S.B F.E D1 R.S SITE PLAN
18.00 7.50 19.60
OFFICE
5.0M X 2.50 M

TYRE SHOP

5.0 M X7.0M

4.00 6.00 4.00 OFFICE SCALE- NTS

4.00
OFFICE

7.75M
AREA

R.S

4.0M X 2.50 M
F.G.W1

4.0M X 2.50 M
1.50
22.70

7.20M

RAMP UP
10.40 8.75 1.08M INDIAN OIL
14.00 AIR TOWER WITH

11.42M
1.25 0.3M HIGH KERB
COMPRESSOR
1.20 M X X1.0 M
GROUND FLOOR PLAN (3) F.G.W1 F.G.W1 PUBLIC INFORMATION

WALL 0.25 THICK (WORKSHOP)

5.88M
SPARE
PARTS
3.0x1.75
BAY - 2 EMBLEM Indian oil
RED SIGN

10.25M
1.80

GL GL GL GL GL GL GL
POLE
3.65 X 8.0
EXIT
AS ASS AS AS AS ASS AS
S S S S S
TECHNICIAN DRIVE WAY FOR LAND
TYRE SHOP TYRE SHOP
RAMP UP

ROOM
NO ENTRY
7.80

3.0 X1.80
GREEN SIGN BUFFER SCAPING
AREA AREA
7.50M

RECEPTION FOR ENTRY STRIP DRIVE WAY


L.P L.P LEV.
5.0 M X7.0M
3.0 X 1.80

CUSTOMER
BAY - 1
L.P

5.0 M X7.0M
1.65 LOUNGE 3.65 X 8.0
3.20

1.6 X 3.0

11.50 FRONT ELEVATION


L.P

ENTRY FIRE EXSITINGUISHER


SCALE - N.T.S 3.00
12.25M 18.48M 12.0M 12.0M

3.50 X 2.50M
26.70 54.73M
SAMPLE

STORE
1.50M HEIGHT R.S R.S CONTAINER RACK
0.25MX0.25M HEIGHT

3.68

R.S
BOUNDARY WALL

1.71M
GAURD WALL
APPROACH APPROACH 14.75M

0.90
ROAD - 1 ROAD - 2 Indane
PLINTH PROTECTION

7.75M
GROUND FLOOR PLAN (2) D1

SCALE - NTS

D1

D1
TOILET
5KG

3.50 X 2.50M
2.0 X 1.68M

ELEC. SALES
2% SLOPE

2% SLOPE

2% SLOPE

2% SLOPE
OFFICE

A.T.M-1
4.00
D3 ROOM DEALERS
ROOM ROOM
3.00 X 3.50 M ROOM
D3
TOILET
2.50 X 3.50M 3.0 X 3.50M 3.0 X 3.50M
I.S.I CLASS NP-4 2.0 X 1.68M
ELEVATIONAL VIEW OF HUME PIPE
5KGS LPG CYLINDER 0.30 0.30 F.G.W
D1
F.G.W D1 F.G.W1
1.10M

0.90
SCALE - N.T.S
30.80M

37.50M
0.90M
COMPCTED
34.30M

GRANULAR
MATERIAL 17.75M
Indane
BED LEVEL BED LEVEL GROUND FLOOR PLAN
Indane
5KG

SCALE :-NTS
5KG

M 0.475
R=

0
.0
13

14 NOTES :-
.0

R
0M

Indane
5KG
Indane 1.70 M 1. The vent pipes of the tanks are 6 mts above the ground and their ends are covered 2 layers of brass wire gauge 11 mesh per
5KG

1X1.0M Ø HUME PIPE CULVERT NP-4 1.0M WIDE OPEN DRAIN


linear centimeters.
DRAIN 1X1.0M Ø HUME PIPE CULVERT NP-4 DRAIN
R
3.
SECTION THROUGH CULVERT 2. Fill points of tanks are provided with cam lock couplings and are provided with air tight threaded brass caps.
00 00
3. SCALE : 1:50 3. All electrical fittings provided are flameproof confirming to IS:2148.
R
4. All the doors and windows of the buildings are provided to open outwards
Indane
5KG
Indane
5. Dip pipe of the tanks are provided with cap assembly.
10.0M

5KG

FLANK WIDE 1.50M 6. No sewer or surface drains are within 6 mts of underground tanks and DUs.
7. The premises to be used only for storage of petroleum products.
ELEVATIONAL VIEW OF 8. Tanks are painted with 2 coats of bituminous paint over 2 coats of red oxide primer to protect corrosions.
5KGS LPG STORE ROOM ON 9. Fabrication design of u/g storage tanks are confirming to IS:10987 (1998) as per CCOE, Nagpur approval ref P-6(3)51 Dt
TO REFINERY
6.87M

STEEL STRUCTURE 04.05.2006


C/L OF ROAD ROAD 10.
11.
Sand Buckets and fire extinguishers are provided as per petroleum norms.
Tank testing has been done by providing controlled pressure of 0.36 Kg/Sqcm for 2 hours.
AREA CHART 12. Dip rods provided are 3280 mm long.
13. Thickness of shell and end plates of the 20 KL tanks are - [Shell - 6 mm] [Ends - 8 mm].
DEVIDER WIDE 2.0M
S.NO. PARTICULARS AREA (Sqm.) 14. Tanks conform to clause 124, 125 & 131 of the petroleum rules 2002.
15. All light poles fitted as per approval of CCE Nagpur vide letter no PL-III (MBI) Dt 26/11/2003. Adequate arrangements have
1. TOTAL LICENCE AREA- 3114.95 SQM been made for proper light at the premises.
TO N.H 5A 16. Natural down slope from edge of the metallic road to culvert on approaches are maintained for free flow of water towards drains.
6.87M

2. PLOT PERIMETER- 254.31 SQM 17. Site meets applicable IRC 1983 norms with latest amendments.
ROAD 3. GROUND FLOOR AREA(1)- 18. The proposed site is free from any type of litigation and no court case is pending in any court of law.
C/L OF ROAD 82.25 SQM
(FOR SALES BUILDING) 19. No high tension line passes through the premises.
4. GROUND FLOOR AREA(2)- 20. Tanks are fed by tank lorry only.
FLANK WIDE 1.50M (OFFICE, TYRE SHOP, LUBRICANT SHOP) 99.93 SQM 21. All electric fittings of E/O dispensing units confirms to IS:2148.
25 MM Ø BOLTS 540 LONG
WITH H.P THREADS 5. GROUND FLOOR AREA(3)- 22. Tank capacity of 20 KL = 3.14x(2.1/2)x(2.1/2)x6.25x1000=21636 Lts. Less Air Capacity = 1636 Lts. Actual Product Storage
LAYOUT PLAN 99.93 SQM
(WORK SHOP) Capacity = 20000 Lts.
SCALE- 1:250 TURN BUCKEL 23. The construction of RO/KSK as per IRC approval no 12/83 and IRC recommendation are being followed.
G.I. SHEET 24. Flex Hoarding may not be used; Tin board hoarding will be used for display advertisement or govt. schems.
GIRDER PURLIN
6.0 M HIGH PLASTERING CM 1 : 3 MIX
50 MM Ø
KERB WALL AROUND THE PIT VENT PIPE
KERB WALL AROUND THE PIT
250 MM THK. BRICK WALL IN CM 1 : 6 PLATE
900
25 MM Ø BOLTS 540 LONG
WITH H.P THREADS
LICENCE NO-P/EC/OR/14/1341(P155841)
12MMØ BAR 2NOS
150

MANHOLE
250 MM THK. BRICK WALL IN CM 1 : 6 300x300x12 G.I. PLAIN SHEET
75X50X6MM THK 200 LONG
MANHOLE (4 NOs.) FOR FALSE CEILING
INDIAN OIL CORPORATION LIMITED
300

72 MM
115 LONG M.S. SOCKET 80 MM Ø G.L G.L 4.00M 6.00M 4.00M SITE INFORMATION
THREADED TO SUIT 80Ø FILL PIPE
MANHOLE COLUMN (Marketing Division)
SAND FILLING
300

FILL PIPE 175


600

G.L
6.0M

250 MM
300 MM 85
EASTERN REGION
900

P.C.C ( 1 : 4 : 8 ) PLOT NO- 1314 (P), 1315(P)


600

100 MM THK.
300

50 MM Ø
Layout Plan of Retail Outlet
900

DIP PIPE P.C.C ( 1 : 4 : 8 ) 50


SAND FILLING
100 MM THK. GUSSET BASE 50MM 300 MM 300 MM 50MM KHATA NO- 135, 166 Location
300

PLATE
PLATE
700 MM
MOUZA- UDAYBAT, OVER PLOT NO- 1314 (P), 1315(P)
SAND FILLING
3350 MM

DRIVEWAY
, KHATA NO- 135, 166, TAHASIL- .........., P.S- TIRTOL NO-257
SAND FILLING

750 EARTHING
EARTHING LEVEL DETAILS OF HOLDING DOWN MOUZA - UDAYBAT
600 BOSS
SAND FILLING

CANOPY DETAILS
BOSS 50 MM Ø BOLTS &TURN BUCKEL , NO-34, DISTT.- JAGATSINGHPUR, STATE-ODISHA
3350 MM

2110

50 MM Ø HOLDING DOWN DIMENSIONS ARE IN MM , SCALE -N.T.S


SUCTION
PIPE 3 NOS SUCTION TANK POSITIONS SCALE - NTS. TAHSIL- .. M/S. COASTAL TRADING COMPANY
PIPE
2110

HOLDING DOWN C.C PEDESTAL


POSITIONS ( 1: 2 :4 )
DETAIL OF TANKS P.S. TIRTOL NO-257 Scale - 1:250
R.C.C MAT RAFT
340

C.C PEDESTAL ( 1: 1. 5 :3 )
( 1: 2 :4 ) TK.NO ITEM QUANTITY DIMENSION PRODUCT CAPACITY CLASS
NEAR. RAIL. STN.
265

P.C.C ( 1 : 4 : 8 ) UNDER GROUND TANK 2.11 M Ø X 6.25 M LONG


PARADEEP
R.C.C MAT RAFT T1 01 MS 20000 LTR CLASS - A ARD ASSOCIATES
75

IN EARTH PIT WITH MAT RAFT


265

( 1: 1. 5 :3 ) 8 TOR @ 300 C/C


P.C.C ( 1 : 4 : 8 ) 12 TOR @ 140 C/C 12 TOR @ 70 C/C 8 TOR @ 90 C/C ( BOTHWAYS ) T2 UNDER GROUND TANK 01 2.11 M Ø X 6.25 M LONG HSD 20000 LTR CLASS - B DISTRICT - JAGATSINGHPUR PREPARED BY
8 TOR @ 300 C/C 8 TOR @ 90 C/C IN EARTH PIT WITH MAT RAFT
75

2110 MM
( BOTHWAYS ) PAD PLATE 200 X200 X6 THK. 12 TOR @ 70 C/C
3310 MM T3 UNDER GROUND TANK 01 2.11 M Ø X 6.25 M LONG HSD 20000 LTR CLASS - B Drawing No.
TOBE WELDED INSITE SHELL PLATE IN EARTH PIT WITH MAT RAFT STATE - ODISHA MO
T/IC/UDAYBAT EO/AM(Engg.)
600 6250 MM 600 CROSS SECTION OF 20 KL U/G TANK T4 UNDER GROUND TANK 01 2.11 M Ø X 6.25 M LONG XP 20000 LTR CLASS - A CONSULTANT Mgr.(R.S.)/SM(R.S) (D.R.S.H.)