You are on page 1of 18

Siemens Healthcare

Training Center Erlangen

Biograph mMR: PET technology

Copyright © Siemens AG 2010. All rights reserved.


Please note: The only released document for end customer training is the user manual.
Page 1 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
two is now one.
The inside story on mMR technology

The mMR technology includes:

 The first whole-body MR-


friendly PET architecture

This product may not have been licensed in accordance with Canadian law.
Please note: The only released document for end customer training is the user manual.
Page 2 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
two is now one.
The inside story on mMR technology

This product may not have been licensed in accordance with Canadian law.
Please note: The only released document for end customer training is the user manual.
Page 3 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
two is now one.
The first whole-body MR-friendly PET architecture

This product may not have been licensed in accordance with Canadian law.
Please note: The only released document for end customer training is the user manual.
Page 4 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
two is now one.
The first whole-body MR-friendly PET architecture

This product may not have been licensed in accordance with Canadian law.
Please note: The only released document for end customer training is the user manual.
Page 5 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
two is now one.
The first whole-body MR-friendly PET architecture

This product may not have been licensed in accordance with Canadian law.
Please note: The only released document for end customer training is the user manual.
Page 6 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
two is now one.
The first whole-body MR-friendly PET architecture

This product may not have been licensed in accordance with Canadian law.
Please note: The only released document for end customer training is the user manual.
Page 7 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
Challenge: Space - Static Magnetic Field
Avalanche Photo Diodes (APD) vs. Photo Multiplier Tubes (PMT)
PMTs APDs

Size 10-52mm dia. 5x5mm

Gain Up to 106 Up to 200

Risetime ~1 ns ~5 ns

QE 20 % 70 %

Magnetically sensitive insensitive

Please note: The only released document for end customer training is the user manual.
Page 8 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
two is now one.
The first whole-body MR-friendly PET architecture

Preliminary PET specifications:

 LSO crystal material

 4 x 4 x 20 mm Crystal element dimension

 ≤4.7 mm transverse spatial resolution


(FWHM @ 1 cm)

 ≥12 cps/kBq sensitivity

 ≥155 kcps peak NEC rate (@ 21.8 kBq/cc)

 25.8 cm FoV in z-direction

(Based on NEMA 2007)

This product may not have been licensed in accordance with Canadian law.
Please note: The only released document for end customer training is the user manual.
Page 9 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
two is now one.
The first whole-body MR-friendly PET architecture

Biograph mMR detector integration enables the industries’ largest PET field of view*

 Eight detectors aligned axially to form one detector head


 Up to 25.8 cm axial (z) field of view!
* Based on Competitive Literature available at time of Publication. Data on file.

This product may not have been licensed in accordance with Canadian law.
Please note: The only released document for end customer training is the user manual.
Page 10 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
two is now one.
Fully optimized for a strong signal

Attenuation Correction Optimization

 µ maps are derived from MRI data –


no additional acquisitions necessary

 MR-based segmentation and


truncation correction methods

 Attenuation correction of the whole


human body

 User customized µ maps are possible

This product may not have been licensed in accordance with Canadian law.
Please note: The only released document for end customer training is the user manual.
Page 11 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
Main Components:
System Overview, changes, adaptions

Biograph mMR is a
new development
based on and
using Verio
components.

(internal name:
Mondrian or
Proj. 018)

Please note: The only released document for end customer training is the user manual.
Page 12 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
System Diagram

Biograph mMR PET


is divided into two
1
main components:

1 PET Detector
Electronics

2 PET Electronic
Cabinet

Please note: The only released document for end customer training is the user manual.
Page 13 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
PET Detector Electronics

Gantry Tunnel
without Detector • PET Gantry
Electronic tunnel isocentric
in the MR tunnel
white pockets for
PET detector
cassettes

56 water-cooled
detector
cassettes with 8
crystal blocks
each

Please note: The only released document for end customer training is the user manual.
Page 14 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
Subcomponents:
Detector Electronic Assembly

• located at the
backside of the
PET Gantry
• each of the 28
water-cooled
DEA supports 2
detectors
( DEA is also
sometimes
named as
DAU = Detector
Acquisition Unit)

Please note: The only released document for end customer training is the user manual.
Page 15 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
Main Components:
PET Filter Plate

from
magnet There is a second
room filter plate to
connect the
detecting PET
gantry with the
evaluating PET
Electronics

from
technical
room

Please note: The only released document for end customer training is the user manual.
Page 16 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
Main Components:
PET Electronic Cabinet

• located in the
technical room
• uses same base
cabinet as
MR-ACC

PRS

ACS

Please note: The only released document for end customer training is the user manual.
Page 17 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center
Siemens Healthcare Training Center
Your global partner for excellence in education.

Copyright © Siemens AG 2010. All rights reserved.


Please note: The only released document for end customer training is the user manual.
Page 18 For internal use only. Copyright © Siemens AG 2010. All rights reserved.
Siemens Healthcare Training Center