You are on page 1of 6

Installation of 19-inch SAU kit and OVP-

ALM8 kit

INSTALLATION INSTRUCTION

1531-NTM 201 3932/1 Uen Rev E


Copyright

© Ericsson AB 2010, 2017. All rights reserved. No part of this document may be
reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to
continued progress in methodology, design and manufacturing. Ericsson shall
have no liability for any error or damage of any kind resulting from the use
of this document.

Trademark List

All trademarks mentioned herein are the property of their respective owners.
These are shown in the document Trademark Information.
Contents
1 Introduction .............................................................................................. 4

2 Included Products ................................................................................... 4


2.1 SAU kit .......................................................................................................4
2.2 OVP-ALM8 kit ............................................................................................4

3 Required Tools......................................................................................... 4

4 Installing the SAU kit............................................................................... 5

5 Installing the OVP-ALM8 kit ................................................................... 6


Installation of 19-inch SAU kit and OVP-ALM8 kit

1 Introduction
This document describes how to install the 19-inch SAU kit for external
alarms. It also describes how to install the OVP-ALM8 kit.

For more information on replacing the SAU, refer to Replacing Alarm


Units.

2 Included Products
The kits include the following products.

2.1 SAU kit


• 1 SAU

• 1 SAU bracket kit

• 1 DIN rail kit for 19-inch rack

• 1 SAU to RBS (SCU) cable

• 1 Installation Instruction

2.2 OVP-ALM8 kit


• 1 OVP-ALM8

• 1 OVP to SAU cable

3 Required Tools
The tools required for this installation are listed below.

• Torx 20 Screwdriver

• Torx 30 Screwdriver

1531-NTM 201 3932/1 Uen Rev E 2010-10-18  Ericsson AB 2010, 2017 4 (6)
Ericsson Internal
Installation of 19-inch SAU kit and OVP-ALM8 kit

4 Installing the SAU kit


1 Attach the 19-inch
mounting brackets
using the 6 screws. Tighten
2 Tighten the screws
using the Torx 20
screwdriver.

3 Attach the cage


nuts in the 19-inch
rack.

4 Attach the SAU


and the DIN rail Tighten
using the 4 screws.

5 Tighten the screws


using the Torx 30
screwdriver.

6 Connect the 17m


cable between the
Power/EC-bus
connector on the
SAU and the SAU
connector on the
SCU in the RBS.

1531-NTM 201 3932/1 Uen Rev E 2010-10-18  Ericsson AB 2010, 2017 5 (6)
Ericsson Internal
Installation of 19-inch SAU kit and OVP-ALM8 kit

5 Installing the OVP-ALM8 kit


1. Attach the OVP
module by pushing it
down and in.

2. Connect the cables


between the SAU and
the OVP module.
Connect Alarm 1-4
on the SAU to 1 on
the OVP and Alarm
5-8 to 2 on the OVP.

3. If more than one OVP


module is installed,
connect Alarm 9-12
and Alarm 13-16 to 1
and 2 respectively on
the following OVP
module and so on.

1531-NTM 201 3932/1 Uen Rev E 2010-10-18  Ericsson AB 2010, 2017 6 (6)