PIER PIER

1
-

CL OF EXP. JOINT
JOINT
L= LENGTH OF I-BEAM

CL OF BEARING
ING

CL OF BEARING
ING
G1 = 26145

L OF BEAR
G2 = 26662

L OF EXP.

F BEAR
G3 = 27179
2 G4 = 27697

CL O
C

C
1000 -
1000
1000 PRE-CAST CONCRETE 1000
PARAPET PRECAST I-BEAM

700

700
700

1480
1480
3 3

2075
1198
- -

1198
2075

825
991

991
866

866
G1

2075
TRACK AXIS

°
2315

2315
2300

83
83

.5
.5

83
83
°
2575

2575
G2

855

10700
10700

9300
9300

855

2575
2315

2315
1525
ALIGNMENT

10700
9300

2300
R125 AXIS

1460
1460

775
2575

G3

2575
450 450
CAST-IN-SITU CAST-IN-SITU
2315

2315
2575
400
END CROSS GIRDER CAST-IN-SITU INTERMEDIATE END CROSS GIRDER

2300
TRACK AXIS
CROSS-GIRDER

2075
2075

G4
875

875
1185

1185
1402

1402
1532

1532
1575
2075
700

700
700
PRE-CAST CONCRETE
14000 PARAPET 14000

28000
1 SPAN LENGTH
-

2 MOTERA
STADIUM
STATION
(Ele.)

-
MAHATMA
1
Koteshwar
CH: 17563.252m
Road

Mandir
CH: 39337.858m
20
Mahatma

Vishwakarma
CH: 2
19016.974m
College

KOTESHWAR MANDIR
PLAN VIEW

CH: 38138.299m
- 24
Sector19
Tapovan
CH: 3

N
19994.376m
Circle

ROAD Narmada
CH: 4
20899.927m
Canal 12
Infocity
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
CH: 28941.692m
11 Circle
SCALE : 1/50

Dholakuva
CH: Koba 5
22050.557m
Circle

CH:
Sector
32791.432m

14
10A
GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
Juna 6
CH: Koba
23056.769m

Sachivalaya

15
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU

1
KEY PLAN

CH: 1749.00m
PDPU
2
NOTES :- Gift City
GIFT CITY

3
CH: 4605.861m

1. NO CONSTRUCTION JOINT SHALL BE PERMITTED DURING CONSTRUCTION OF I GIRDER.


2. CONCRETE FOR PRECAST I-GIRDER SHALL BE DESIGN MIX WITH A MINIMUM 28 DAYS
CHARACTERISTIC STRENGTH OF 50 MPa ON 150mm CUBES.
3. LIFTING ARRANGEMENT OF GIRDERS SHALL BE PROVIDED BY THE CONTRACTOR AND
240

SHOULD BE CHECKED BY ENGINEER IN CHARGE IF ANY CHANGES.


400

REFERENCE DRAWINGS :- 486 (SK.) 721 (SK.) 1208 (SK.)


1. FOR GENERAL NOTES REFER DRAWING DDCP2GMRL-DD-ELV-ST-DW-11001 &11002. 483 (SQ.) 717 (SQ.) 1200 (SQ.)
2. PRECAST I-GIRDER CONCRETE OUTLINE DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09054 & 09055. R0 First Issue MK PB MS 24-09-20
3.
4.
PRECAST I-GIRDER PRESTRESSING LAYOUT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09056 & 09057.
FOR CAST-IN-SITU CROSS GIRDER REINFORCEMENT REFER SEPARATE DRAWING.
SECTION 3-3 REV. PARTICULARS DRN. CHD. VER. DATE

5. FOR CAST-IN-SITU SLAB REINFORCEMENT REFER SEPARATE DRAWING. SCALE : 1/25 PROJECT NAME :
6. FOR DRAINAGE DETAIL REFER SEPARATE DRAWING. DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 GENERAL ARRANGEMENT - PSC I-GIRDER (2.0M DEPTH)
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND 28M CURVED SPAN WITH 4 I-BEAM
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 1 OF 3
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09051
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 24-09-20
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G051_X.DWG


PIER PIER

CL OF EXP. JOINT

CL OF EXP. JOINT
CL OF BEARING

CL OF BEARING

CL OF BEARING

CL OF BEARING
HAUNCH
150X150 (TYP.)

50 EJ 50 EJ

240
450 400 450

1000 1000 1000 1000


14000 14000
28000
SPAN LENGTH

DETAIL -A

LONGITUDINAL SECTION
PIER SCALE : 1/50

CL OF EXP. JOINT
CL OF BEARING CL OF BEARING
1000 1000
50

NOTES :-
1. NO CONSTRUCTION JOINT SHALL BE PERMITTED DURING CONSTRUCTION OF I GIRDER.
2. CONCRETE FOR PRECAST I-GIRDER SHALL BE DESIGN MIX WITH A MINIMUM 28 DAYS
CHARACTERISTIC STRENGTH OF 50 MPa ON 150mm CUBES.
HAUNCH HAUNCH 3. LIFTING ARRANGEMENT OF GIRDERS SHALL BE PROVIDED BY THE CONTRACTOR AND
150X150 (TYP.) 150X150 (TYP.) SHOULD BE CHECKED BY ENGINEER IN CHARGE IF ANY CHANGES.

150 450 225 225 450 150 REFERENCE DRAWINGS :-


1. FOR GENERAL NOTES REFER DRAWING DDCP2GMRL-DD-ELV-ST-DW-11001 &11002.
2. PRECAST I-GIRDER CONCRETE OUTLINE DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09054 & 09055.
240

240
3. PRECAST I-GIRDER PRESTRESSING LAYOUT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09056 & 09057.
4. FOR CAST-IN-SITU CROSS GIRDER REINFORCEMENT REFER SEPARATE DRAWING.
5. FOR CAST-IN-SITU SLAB REINFORCEMENT REFER SEPARATE DRAWING.
6. FOR DRAINAGE DETAIL REFER SEPARATE DRAWING.
150

150
VARIES VARIES
50
1600

1600
2000

2000 MOTERA
STADIUM
STATION
(Ele.)

MAHATMA
1
Koteshwar
CH: 17563.252m
Road

Mandir
CH: 39337.858m
20
Mahatma

Vishwakarma
CH: 2
19016.974m
College

KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
Tapovan
CH: 3

N
19994.376m
Circle

ROAD Narmada
CH: 4
20899.927m
Canal 12
Infocity
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

CH:
Sector
32791.432m

14
10A
GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
Juna 6
CH: Koba
23056.769m

Sachivalaya

15
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU

1
250

250

KEY PLAN

CH: 1749.00m
PDPU
2
PRECAST PRECAST Gift City
GIFT CITY

3
CH: 4605.861m

I-GIREDR I-GIREDR
450 VARIES VARIES 450
1000 1000

R0 First Issue MK PB MS 24-09-20

REV. PARTICULARS DRN. CHD. VER. DATE


PROJECT NAME :

DETAIL-A DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
SCALE : 1/25
DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 GENERAL ARRANGEMENT - PSC I-GIRDER (2.0M DEPTH)
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND 28M CURVED SPAN WITH 4 I-BEAM
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 2 OF 3
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09052
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 24-09-20
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G052_X.DWG


PRE-CAST CONCRETE TRACK AXIS ALIGNMENT AXIS TRACK AXIS PRE-CAST CONCRETE
PARAPET PARAPET
9300

2075 2575 2575 2075

RAIL LEVEL RAIL LEVEL

SLOPE 2.5% SLOPE 2.5%

TYP

TYP
200

200
240
240
TYP
400

240

400
400

400
150 150
CAST-IN-SITU

TYP.
983
END CROSS
GIRDER
450
TYP. 450 450 450

2000
50mm DIA HOLE
FOR FUTURE
PRESTRESSING
PRECAST
I-BEAM
175 175
JACK JACK
PRECAST LOCATION LOCATION

(TYP)
250
PIER CAP 600 600 600 600

855 (SK.) 1460 (SK.)


2315 (SK.) 850 (SQ.) 2315 (SK.) 1450 (SQ.) 2315 (SK.)
VARIES VARIES
2300 (SQ.) 2300 (SQ.) 2300 (SQ.)
700 9300 700
10700

SECTION 1-1
SCALE : 1/25

TRACK AXIS ALIGNMENT AXIS TRACK AXIS


NOTES :-
PRE-CAST CONCRETE PRE-CAST CONCRETE
PARAPET PARAPET 1. NO CONSTRUCTION JOINT SHALL BE PERMITTED DURING CONSTRUCTION OF I GIRDER.
9300 2. CONCRETE FOR PRECAST I-GIRDER SHALL BE DESIGN MIX WITH A MINIMUM 28 DAYS
CHARACTERISTIC STRENGTH OF 50 MPa ON 150mm CUBES.
2075 2575 2575 2075 3. LIFTING ARRANGEMENT OF GIRDERS SHALL BE PROVIDED BY THE CONTRACTOR AND
SHOULD BE CHECKED BY ENGINEER IN CHARGE IF ANY CHANGES.
RAIL LEVEL RAIL LEVEL

REFERENCE DRAWINGS :-
1. FOR GENERAL NOTES REFER DRAWING DDCP2GMRL-DD-ELV-ST-DW-11001 &11002.
2. PRECAST I-GIRDER CONCRETE OUTLINE DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09054 & 09055.
3. PRECAST I-GIRDER PRESTRESSING LAYOUT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09056 & 09057.
4. FOR CAST-IN-SITU CROSS GIRDER REINFORCEMENT REFER SEPARATE DRAWING.
SLOPE 2.5% SLOPE 2.5% 5. FOR CAST-IN-SITU SLAB REINFORCEMENT REFER SEPARATE DRAWING.
TYP

TYP
200

200
6. FOR DRAINAGE DETAIL REFER SEPARATE DRAWING.
240

PRECAST MOTERA
STADIUM
STATION
(Ele.)

I-BEAM MAHATMA
1
Koteshwar
CH: 17563.252m
Road

Mandir
CH: 39337.858m
20
Mahatma

Vishwakarma
CH: 2
19016.974m
College

KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
CAST-IN-SITU
Tapovan
CH: 3

N
19994.376m
Circle

ROAD Narmada
CH: 4
20899.927m
Canal 12
Infocity

INTERMEDIATE
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

CROSS-GIRDER
2000

CH:
Sector
32791.432m

14
10A
GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
Juna 6
CH: Koba
23056.769m

400 400 400


Sachivalaya

15
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU

1
50mm DIA HOLE
KEY PLAN

CH: 1749.00m
PDPU
2
FOR FUTURE GIFT CITY
PRESTRESSING
Gift City

3
CH: 4605.861m
TYP.
150
(TYP)
250

232.5
TYP.
1525 775
TABLE :-
VARIES 2300 2300 2300 VARIES R1 Revised MK PB MS 10/21/2020
700 9300 700 SQ. SQUARE DIMENSION R0 First Issue MK PB MS 9/24/2020
10700 SK. SKEW DIMENSION REV. PARTICULARS DRN. CHD. VER. DATE
PROJECT NAME :
SECTION 2-2 DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
SCALE : 1/25
DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 GENERAL ARRANGEMENT - PSC I-GIRDER (2.0M DEPTH)
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND 28M CURVED SPAN WITH 4 I-BEAM
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 3 OF 3
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09053
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R1
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 9/24/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G053_X.DWG


A B C D E D C B A
- - - - - - - - -

CL OF PIER CL OF BEARING CL OF I-GIRDER CL OF BEARING CL OF PIER


550 1500 1500 VARIES (20145 TO 21697) 1500 1500 550

150

150
150
37

37
100
1750

1750
CAST-IN-SITU INTERMEDIATE

1350

2000
CROSS-GIRDER
2000
1763

1763
450 400 450

250 150
50

50
CAST-IN-SITU CAST-IN-SITU
50 END CROSS-GIRDER END CROSS-GIRDER 50
DETAIL 1
450 VARIES VARIES 450

ELEVATION OF I-BEAM
SCALE : 1/20

A B C D E D C B A
- - - - - - - - -

CL OF PIER CL OF BEARING CL OF I-GIRDER CL OF BEARING CL OF PIER


550 1500 1500 VARIES (20145 TO 21697) 1500 1500 550

400 CAST-IN-SITU INTERMEDIATE


450 CROSS-GIRDER
75

CAST-IN-SITU CAST-IN-SITU
800
650

END CROSS-GIRDER END CROSS-GIRDER


75

450 VARIES VARIES 450

TOP PLAN OF I-BEAM


SCALE : 1/20

MOTERA
STADIUM
STATION
(Ele.)

MAHATMA
1
Koteshwar
CH: 17563.252m
Road

Mandir
CH: 39337.858m
20
Mahatma

650 Vishwakarma
CH: 2
19016.974m
College

KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
25 600 25
Tapovan
CH: 3

N
19994.376m
Circle
25

ROAD Narmada
CH: 4
20899.927m
Canal 12
Infocity
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

CH:
Sector
32791.432m

14
10A
GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
Juna 6
CH: Koba
23056.769m

Sachivalaya

15
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU

1
BEARING WEDGE WILL BE CASTED ALONG WITH THE
UP TO SLOPE

I-BEAM AND ITS SLOPE WILL BE ADJUSTED AS PER


D. VARIABLE

KEY PLAN

CH: 1749.00m
PDPU
2
LONGITUDINAL PROFILE
GIFT CITY
650
600

Gift City

3
CH: 4605.861m

NOTES :-
1. FOR GENERAL NOTES REFER DRAWING DDCP2GMRL-DD-ELV-ST-DW-11001 &11002.
2. NO CONSTRUCTION JOINT SHALL BE PERMITTED DURING CONSTRUCTION OF I GIRDER.
D

25

BEARING WEDGE 3. CONCRETE FOR PRECAST I-GIRDER SHALL BE DESIGN MIX WITH A MINIMUM 28 DAYS
25 600 25 CHARACTERISTIC STRENGTH OF 50 MPa ON 150mm CUBES.
4. LIFTING ARRANGEMENT OF GIRDERS SHALL BE PROVIDED BY THE CONTRACTOR AND
650 SHOULD BE CHECKED BY ENGINEER IN CHARGE IF ANY CHANGES.
X
DETAIL - 1 X
25

- -
PLAN VIEW X-X R0 First Issue MK PB MS 24-09-20
SCALE : 1/10 SCALE : 1/10 REV. PARTICULARS DRN. CHD. VER. DATE
PROJECT NAME :
DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 CONCRETE OUTLINE - PSC I-GIRDER (2.0M DEPTH)
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND 28M CURVED SPAN
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 1 OF 2
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09054
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 24-09-20
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G054_X.DWG


800 800 800 800 800

150

150

100 150

100 150
37

CONSTRUCTION

CONSTRUCTION
130 130 205 390 205 205 390 205
75 75 VARIABLE

JOINT

JOINT
VARIABLE

VARIABLE

1350

1350
2000

2000

2000

2000

2000
1813
VARIABLE
130 130 130 130
50mm DIA HOLE FOR
FUTURE PRESTRESSING

250 150

250 150
37.5
50 50

250
650 650 650 650 650
DETAIL 2

SECTION A-A SECTION B-B SECTION C-C SECTION D-D SECTION E-E
SCALE : 1/20 SCALE : 1/20 SCALE : 1/20 SCALE : 1/20 SCALE : 1/20

CL OF ALIGNMENT
CL OF TRACK AXIS CL OF TRACK AXIS

D. VARIABLE
UP TO SLOPE
INTERMEDIATE INTERMEDIATE
END I-GIRDER END I-GIRDER
I-GIRDER I-GIRDER
D

25 600 25
650

DETAIL - 2 CAST-IN-SITU
SCALE : 1/10 CROSS GIRDER MOTERA
STADIUM
STATION
(Ele.)

MAHATMA
1
Koteshwar
CH: 17563.252m
Road

Mandir
CH: 39337.858m
20
Mahatma

HALF SECTION AT SUPPORT HALF SECTION AT MID SPAN


Vishwakarma
CH: 2
19016.974m
College

KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
Tapovan
CH: 3

N
19994.376m
Circle

ROAD Narmada
CH: 4
20899.927m
Canal 12
Infocity
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
SCALE : 1/40 SCALE : 1/40

CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

CH:
Sector
32791.432m

14
10A
GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
Juna 6
CH: Koba
23056.769m

Sachivalaya

15
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU

1
KEY PLAN

CH: 1749.00m
PDPU
2
Gift City
GIFT CITY

3
CH: 4605.861m

NOTES :-
1. FOR GENERAL NOTES REFER DRAWING DDCP2GMRL-DD-ELV-ST-DW-11001 &11002.
2. NO CONSTRUCTION JOINT SHALL BE PERMITTED DURING CONSTRUCTION OF I GIRDER.
3. CONCRETE FOR PRECAST I-GIRDER SHALL BE DESIGN MIX WITH A MINIMUM 28 DAYS
CHARACTERISTIC STRENGTH OF 50 MPa ON 150mm CUBES. R1 Revised MK PB MS 10/21/2020
4. LIFTING ARRANGEMENT OF GIRDERS SHALL BE PROVIDED BY THE CONTRACTOR AND
R0 First Issue MK PB MS 9/24/2020
SHOULD BE CHECKED BY ENGINEER IN CHARGE IF ANY CHANGES.
REV. PARTICULARS DRN. CHD. VER. DATE
PROJECT NAME :
DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 CONCRETE OUTLINE - PSC I-GIRDER (2.0M DEPTH)
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND 28M CURVED SPAN
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 2 OF 2
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09055
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R1
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 9/24/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G055_X.DWG


1 2 3 4 B
-

X= 10848.5

X= 10848.5

X= 10848.5

X= 10848.5
A
-

Z= 138

Z= 373

Z= 608

Z= 843
L/2
140 C
L OF BEARING

X= 140
4
Z= 1650

1157
X= 140
3
Z= 1250
2000

X= 140
2 4
Z= 850

235
3

235
X= 140
1
Z= 450 2

138 235
Z
1
X

X= 1140
Z= 1512
X= 1140
Z= 1140
X= 1140

X= 1140

DETAIL A
HALF ELEVATION OF I-BEAM
Z= 397

Z= 769

SCALE : 1/20

A 1 2 3 4 B
- -

L/2
140 CL OF BEARING

Y
325

X
650

1
325

2
3
4
X= 140
Y= 0
1 2 3 4 HALF PLAN VIEW OF I-BEAM
SCALE : 1/20

CABLE CO-ORDINATES
CABLE X = 140 X = 1000 X = 1850 X = 2450 X = 3050 X = 3650 X = 4250 X = 4850 X = 5450 X = 6050 X =6650 X = 7250 X = 7850 X = 8450 X = 9050 X = 9650 X = 10250 X = 10848.5
NUMBER Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z Y Z SPECIAL NOTES :-
1 0 450 0 404 0 361 0 332 0 305 0 280 0 257 0 237 0 218 0 201 0 186 0 173 0 163 0 154 0 147 0 142 0 139 0 138
1. FOR THESE SPANS, NON SHRINKABLE CONCRETE SHALL BE USED.
2 0 850 0 780 0 713 0 669 0 628 0 590 0 556 0 524 0 496 0 470 0 447 0 427 0 411 0 397 0 387 0 379 0 375 0 373
2. THE LENGTH OF STRAIGHT PORTION OF THE CABLE SHALL BE
3 0 1250 0 1155 0 1066 0 1006 0 952 0 901 0 854 0 812 0 773 0 738 0 708 0 681 0 659 0 641 0 627 0 616 0 610 0 608
SUITABLY MODIFIED AS PER GIRDER LENGTH.
4 0 1650 0 1531 0 1418 0 1344 0 1275 0 1211 0 1152 0 1099 0 1050 0 1006 0 968 0 935 0 907 0 885 0 866 0 853 0 846 0 843

LEGEND:-
350

MOTERA
STADIUM
STATION
(Ele.)

MAHATMA
1
Koteshwar
CH: 17563.252m
Road

Mandir
CH: 39337.858m
20
Mahatma

4 END OF CABLE
Vishwakarma
CH: 2
19016.974m
College

KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
Tapovan
CH: 3

N
19994.376m
Circle

ROAD
400

1157

Narmada
CH: 4
20899.927m
Canal 12
Infocity
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

CH:
Sector
32791.432m

14
10A
START OF PARABOLIC CURVE GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
Juna 6
CH: Koba
23056.769m

Sachivalaya

15
3
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU

1
400
2000

2000

END OF PARABOLIC CURVE


KEY PLAN

CH: 1749.00m
PDPU
2
2 4 Gift City
GIFT CITY

3
CH: 4605.861m
235
400

3
235

1 NOTES :-
2 1. PRESTRESSING STEEL SHALL BE 15.2MM NOMINAL DIA STRANDS CONFIRMING TO IS:14268-1995,
138 235
450

CLASS-2 LOW RELAXATION UNCOATED STRESS RELIEVED STRANDS.


1 2. ELONGATION IS BASED ON E = 195000 N/MM², K = 0.002/M, µ = 0.17 / RAD., A = 140MM²
3. ANCHORAGES SHALL BE PROCURED FROM APPROVED MANUFACTURES ONLY.
325 325 325 325 4. GROUTING SHALL BE DONE IMMEDIATELY AFTER SATISFACTORY COMPLETION OF PRESTRESSING R0 First Issue MK PB MS 24-09-20
IN ACCORDANCE WITH IRS CBC CODE 2014.
650 650 REV. PARTICULARS DRN. CHD. VER. DATE
PROJECT NAME :
SECTION A-A SECTION B-B DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
SCALE : 1/20 SCALE : 1/20
DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 PRESTRESSING DETAILS - PSC I-GIRDER (2.0M DEPTH)
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND 28M CURVED SPAN
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 1 OF 2
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09056
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 24-09-20
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G056_X.DWG


NOTES:-
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE SPECIFIED. SCHEDULE OF PRESTRESSING CABLES FOR 28.0M 4I-BEAM SPAN
2. FOR GENERAL NOTES PLEASE REFER DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-11001 & 11002.
Exit
3. TYPE OF TENDONS-19K15 STRANDS-UNCOATED STRESS RELIEVED LOW RELAXATION Jacking Force Cable Length Theoretical Elongation at
S.No . Cable No. No. of Strands Anchorage System Angles Stressing
STEEL CONFORMING TO IS:14268 CLASS-II SHALL BE USED. (In Each Strand) (KN) (mm) stressing End (mm)
(degree)
NOMINAL DIA SHALL BE 15.2mm WITH MINIMUM BREAKING STRENGTH OF 260.7KN AND
MINIMUM 0.2% PROOF LOAD OF 234.6 KN. 1 Cable - 1 14 19-K15 195.3 29429 191.3 3.034 One End
4. ALL STRANDS SHALL BE STRESSED SIMULTANEOUSLY FROM ONE END ONLY USING 2 Cable - 2 13 19-K15 195.3 29445 189.6 4.631 One End
MULTISTRAND JACKS.
3 Cable - 3 14 19-K15 195.3 29468 189.8 6.277 One End
5. ALL PRESTRESSING DUCT SHALL BE IN THE FORM OF CORRUGATED HDPE DUCT
OF 110mm INNER DIA. FOR 19K15. 4 Cable - 4 13 19-K15 195.3 29497 188.9 7.857 One End
6. PT DUCTS CAN BE MADE OF ONE SINGLE PIECE.
7. ALL CABLES TO HAVE SMOOTH PROFILE (WITHOUT KINKS) PASSING THROUGH TENDON 800
ORDINATES. FIRM SUPPORTS AT EVERY 0.75m INTERVAL SHOULD BE INSTALLED. 75 125 25 350 25 125 75
TABLE-1 SEQUENCE OF PRESTRESSING
8. THE LENGTH OF CABLES INDICATED ARE INCLUSIVE OF 1000 MILLIMETER
EXTRA LENGTH AT EACH END. THE TOTAL LENGTH OF CABLE SHALL BE SL. NO. ITEM DAY NO.
VERIFIED AT SITE. ADDITIONAL LENGTH BEYOND TRUMPET FACE AT
ENDS REQUIRED FOR ANCHORING CABLES AND ATTACHING JACK IS TO
I GIRDER SEGMENTS ARE CASTED AND LIFTED FROM THE
BE ADDED IN CONSULTATION WITH SYSTEM MANUFACTURER. 1. COMPLETION OF CASTING OF PSC GIRDER
1 2 CASTING BED AFTER GAINING 28 DAYS STRENGTH.
9. EXTRA LENGTH OF STRANDS PROJECTING BEYOND END BLOCK SHALL NOT BE CUT
3 4
AFTER STRESSING PRIOR TO APPROVAL OF STRESSING OPERATION. THESE SHALL BE PRESTRESSING OF CABLES IN FOLLOWING SEQUENCE
CUT ONLY WHEN INSTRUCTIONS FOR GROUTING ARE ISSUED BY ENGINEER INCHARGE. CABLE 2 14 DAYS AFTER CASTING OF GIRDER OR WHEN GIRDER
10. EXTENSION SHALL BE RECHECKED AT 24 HOURS AFTER ANCHORING TO CABLE 3 CONCRETE ATTAINS A STRENGTH OF 40MPa, WHICHEVER IS
2. LATER.

140
OBSERVE SLOW SLIPPAGE. THE MATTER SHALL BE REPORTED FOR CABLE 1
EXCESSIVE SLIPPAGE IF ANY. CABLE 4
11. EXTENSION OF CABLE SHALL BE VERIFIED AT SITE. IN CASE OF VALUE OF µ AND k ARE 28 DAYS (MIN.) AFTER CASTING OF GIRDER OR WHEN GIRDER
10° 10° CASTING OF DECK SLAB AND CROSS GIRDER
FOUND TO BE DIFFERENT THAN THOSE CONSIDERED FOR DESIGN, EXTENSION SHALL 3. CONCRETE ATTAINS A STRENGTH OF 50MPa, WHICHEVER IS
AFTER ERECTION OF ALL GIRDERS IN A SPAN
SECTION 2-2
BE SUITABLY MODIFIED AFTER APPROVAL OF GMRL/GC. LATER.
12. THE FIXING OF WEDGES AT DEAD END SHOULD BE DONE CAREFULLY.
THE SLIP AT DEAD END DURING STRESSING SHOULD ALSO BE SCALE : 1/10
RECORDED.THE NET ELONGATION SHOULD BE ASCERTAINED
CONSIDERING THE SLIP AT DEAD END DURING STRESSING. 1
-

13. THE EXTENSION MENTIONED IN TABLE SHALL BE MODIFIED AT SITE IN 164


CASE ACTUAL VALUE OF AREA OF STRANDS 'A' & MODULUS OF 140
75 125 25 350 25 125 75
ELASTICITY 'E' VARIES FROM THOSE ASSUMED IN DESIGN, REVISED
EXTENSION SHALL BE CALCULATED AS UNDER REVISED
EXTENSION = (19500000) X ORIGINAL EXTENSION (140)
X
(NEW MODULUS) (NEW AREA)

10°
29

350
14. GROUTING SHALL BE DONE AS EARLY AS POSSIBLE AFTER STRESSING THE TENDON.
BUT NOT LATER THAN TWO WEEKS.
15. ALL DIAL GAUGES SHALL BE CALLIBRATED WELL IN ADVANCE OF PRESTRESSING WORK.

350
347

16. JACK EFFICIENCY TESTS SHALL BE CONDUCTED AT SITE AND PRESSURE GAUGE 4
READINGS ADJUSTED SUITABLY. 2 2
- -
17. PRESTRESSING WILL BE EFFECTED SYMMETRICALLY W.R.T. VERTICAL AXIS.
18. ALL PRESTRESSING STEEL SHALL BE SUITABLY CONNECTED TO THE UNTENSIONED 4

400
53

°
7.857
REINFORCEMENT IN ORDER TO AVOID ELECTRIC CORROSION.

68
19. PROTECTION OF END ANCHORAGES WILL BE DONE AS GIVEN IN SPECIFICATIONS OF
VIADUCT.

350
348

20. SYSTEM MANUFACTURER'S CERTIFICATES OF MATERIALS TESTS (NOT OLDER THAN 3


ONE YEAR) SHALL BE OBTAINED PRIOR TO PRESTRESSING OPERATION. THIS WILL
ALSO INCLUDE SATISFACTORY RESULTS OF ANCHORAGE EFFICIENCY AND LOAD
3 SPECIAL NOTE :-
TRANSFER TESTS.

6.277°
400
52
2000

2000

61
21. PRESTRESSING MANUFACTURER'S AUTHORISED TECHNICAL REPRESENTATIVE THE CABLE LENGTH PROVIDED IN THE ABOVE TABLE CORRESPONDS TO THE G4 GIRDER
SHALL BE REQUIRED TO SUPERVISE EVERY OPERATION RELATING TO LAYING AND (INCLUSIVE OF 1000MM EXTRA LENGTH ON EACH END). FOR CABLE LENGTH CORRESPONDING
STRESSING & GROUTING OF PRESTRESSING CABLES. TO G1, G2 & G3 GIRDERS, STRAIGHT PORTION OF THE CABLE SHOULD BE SUITABLY MODIFIED

350
349

1650
ACCORDING TO THE GIRDER LENGTH.

°
4.631
2

400
51

1250

56
MOTERA
STADIUM
STATION
(Ele.)

MAHATMA
1
Koteshwar
CH: 17563.252m
Road

Mandir
CH: 39337.858m
20
Mahatma

Vishwakarma
CH: 2
19016.974m
College

KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
Tapovan
CH: 3

N
19994.376m
Circle

ROAD

350
Narmada
CH: 4
20899.927m
Canal 12
Infocity
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
350

850

CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

CH:
Sector
32791.432m

14
10A
GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
Juna 6
CH: Koba
23056.769m

3.034°
Sachivalaya

15
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU

1
1
23

KEY PLAN
450

450

CH: 1749.00m
PDPU
2
Gift City
GIFT CITY

3
CH: 4605.861m

CASTING OF PT RECESS USING MORTAR 131

VIEW 1-1 END PATCH. MORTAR SHALL BE MADE OF


PORTLAND CEMENT + SAND (CEMENT TO
140
DETAIL A
SCALE : 1/10 SAND RATIO: 1:2) PRIOR TO PLACING MORTAR, SCALE : 1/10
INNER FACES OF RECESS SHALL BE COVERED
1
WITH EPOXY BONDING COMPOUND. - R0 First Issue MK PB MS 24-09-20

REV. PARTICULARS DRN. CHD. VER. DATE


PROJECT NAME :
DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 PRESTRESSING DETAILS - PSC I-GIRDER (2.0M DEPTH)
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND 28M CURVED SPAN
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 2 OF 2
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09057
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 24-09-20
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G057_X.DWG


CL OF BEARING / CL OF BEARING /
DIAPHRAGM CL OF I-GIRDER DIAPHRAGM

4- T15 PT STRAND 4- T15 PT STRAND


2000

2000
ON EACH SIDE ON EACH SIDE

200

200
900 900 900 900

1000 1000

TYPICAL LIFTING ARRANGEMENT


SCALE : 1/20

C
L OF BEARING / C
L OF LIFTING POINT
CL GIRDER
DIAPHRAGM

A
-

250
LIFTING BAR
GROUTED RECESS

NOTES:-
4 NO. 15.2 mm DIA. 1. MINIMUM 28 DAY CHARACTERISTIC COMPRESSIVE STRENGTH OF CONCRETE SHALL BE M50MPa.
STRESS RELIVED 2. GIRDERS SHALL BE CAST HORIZONTALLY.
SUPER GRADE STRANDS 3. CONCRETE SHALL NOT BE DRILLED OR OTHERWISE DISTURBED ONCE INITIAL SET HAS OCCURRED UNTIL AFTER TRANSFER STRENGTH
HAS BEEN ACHIEVED.
4. EACH GIRDER SHALL BE INDEPENDENTLY BRACED AGAINST OVERTURNING PRIOR TO RELEASE BY THE CRANE OR LIFTING DEVICE.
5. LIFTING LOOPS SHALL BE PLACED WITH THE PLANE OF THE LOOP PERPENDICULAR TO THE LONGITUDINAL AXIS OF THE GIRDER.
6. HANDLING & TRANSPORTATION OF PRECAST I-BEAM AT ERECTION SITE REQUIRE CAREFUL OPERATION BY CONTRACTOR.
7. THE LIFTING HOLE LOCATION AND NUMBER SHOWN ON DRAWING MAY BE CHANGES BUT SHOULD BE APPROVED BY THE DDC / GMRL.
2000

8. STRAND USED IN LIFTING HOOK SHOULD BE NEW STRAND.


2NOS. 2NOS.
T15 PT STRAND T15 PT STRAND
4- T15 PT STRAND
ON EACH SIDE

MOTERA
STADIUM
STATION
(Ele.)

MAHATMA
1
Koteshwar
CH: 17563.252m
Road

Mandir
CH: 39337.858m
20
Mahatma

Vishwakarma
CH: 2
19016.974m
College

KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
Tapovan
CH: 3

N
19994.376m
Circle

ROAD Narmada
CH: 4
20899.927m
Canal 12
Infocity
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

CH:
Sector
32791.432m

14
10A
GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
Juna 6
CH: Koba
23056.769m

Sachivalaya

15
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU

1
KEY PLAN

CH: 1749.00m
PDPU
2
Gift City
GIFT CITY

3
CH: 4605.861m

135 135

200
900 900

1000
A
-
VIEW A-A R0 First Issue MK PB MS 10/31/2020
SCALE : 1/10

TYP. SECTION AT LIFTING POINT


REV. PARTICULARS DRN. CHD. VER. DATE
PROJECT NAME :
SCALE : 1/10 DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 PSC I-GIRDER
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND LIFTING ARRANGEMENT
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 1 OF 1
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09064
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/31/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G064_X.DWG


1 2 3
- - -
4
-

ZONE A = 1500(FIXED) ZONE B = 1500(FIXED) ZONE C = 3000(FIXED) ZONE D(VARIES)

ALTERNATE
ALTERNATE

DETAIL 1

ALTERNATE

HALF ELEVATION VIEW A-A


REFER DECK 80 SCALE : 1/20
SLAB DRAWING

600
60 60 60 60 60 60 60 60 60 60 SPECIAL NOTES:-
1. THIS DRAWING SHOWS PRINCIPLE OF REINFORCEMENT ADJUSTMENT FOR VARIABLE I-BEAM LENGTH .

60 60 60 60 60 60 60 60 60 60
2. THIS REINFORCEMENT DRAWING PERTAINS TO A STANDARD I-BEAM OF LENGTH 28M.
3. SAME BAR DIA., SHAPE , SPACING, AS STANDARD I-BEAM FOR 28M SHALL BE FOLLOWED.
REBAR TO BE 4. THE LENGTHS OF LONGITUDINAL BAR MARKS 6,7A,7B,7C,7D,9,10A,10B,11,12A & 12B OF ZONE D ONLY SHALL BE
FOLDED DURING ADJUSTED ACCORDING TO VARIABLE I-BEAM LENGTH.
CASTING AND 5. THE NUMBER OF TRANSVERSE BAR MARKS 1,2,3B & 5A OF "ZONE D" ONLY SHALL BE ADJUSTED ACCORDING TO

600
UNFOLDED VARIABLE I-BEAM LENGTH.
BEFORE 6. FOR REINFORCEMENT CROSS-SECTION 1-1, 2-2, 3-3 & 4-4, REFER DRAWING NO.
CASTING OF PT DDCP2GMRL-DD-ELV-ST-DW-09068 & 09069.
RECESS AT SITE 7. AS PER PT LAYOUT FOR DIFFERENT SPANS, THE REINFORCEMENT SHOULD BE CHANGED.

ANCHORAGE REINFORCEMENT DETAILS (I.E: SPIRAL ETC,)


MESH REINFORCEMENT SHALL BE PROVIDED MAXIMUM OF GIVEN REINFORCEMENT OR
REINFORCEMENT REQUIRED AS PER REQUIREMENT OF PRESTRESSING MOTERA
STADIUM
STATION
(Ele.)

SUPPLIER / CONTRACTOR IN CONSULTATION WITH ENGINEER MAHATMA


DETAIL X
1
Koteshwar
CH: 17563.252m
Road

Mandir
CH: 39337.858m
20
Mahatma

Vishwakarma
CH: 2
19016.974m
College

KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
Tapovan
CH: 3

N
19994.376m
Circle

ROAD Narmada
CH: 4
20899.927m
Canal 12
Infocity

SCALE : 1/10
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

CH:
Sector
32791.432m

14
10A
GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
Juna 6
CH: Koba
23056.769m

NOTES :-
Sachivalaya

15
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU

1
1. CLEAR COVER TO ANY REINFORCEMENT : 40mm.
2. ANCHORAGE LENGTHS, Ld =41Ø,LAP LENGHT=58Ø,WHERE Ø IS THE DIAMETER OF LESSER DIA BAR LAPPED.
SPIRAL REINFORCEMENT AS PER
KEY PLAN

CH: 1749.00m
PDPU
2
PRESTRESSING SUPPLIER 3. LAPPING SHALL BE STAGGERED AND NOT MORE THAN 50% BARS SHALL BE LAPPED AT A SECTION.
GIFT CITY
4. THE DIMENSIONS GIVEN IN BAR BENDING SCHEDULE ARE OUTSIDE DIMENSIONS EXPRESSED IN MM.
Gift City

3
CH: 4605.861m

5. THE ANGLES GIVEN ARE ANGLES OF BENDING EXPRESSED IN DEGREES.


6. WHEREVER REINFORCEMENT FOULS WITH CABLE, REINFORCEMENT SHALL BE SUITABLY MODIFIED.

REFERENCE DRAWINGS :-
1. FOR GENERAL NOTES REFER DRAWING DDCP2GMRL-DD-ELV-ST-DW-11001 &11002.
2. FOR PRECAST I-GIRDER CONCRETE OUTLINE DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09054 & 09055.
3. FOR PRECAST I-GIRDER PRESTRESSING LAYOUT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09056 & 09057. CONCRETE GRADE - M50 R0 First Issue MK PB MS 10/31/2020

4. FOR CAST-IN-SITU CROSS GIRDER REINFORCEMENT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09072 & 09073. REINFORCEMENT GRADE - Fe500 D REV. PARTICULARS DRN. CHD. VER. DATE
20

5. FOR CAST-IN-SITU SLAB REINFORCEMENT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09075 TO 09077. PROJECT NAME :
DETAIL X 6. FOR PRECAST I-GIRDER LIFTING ARRANGEMENT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09064.
DETAIL 1 7. FOR DRAINAGE & PARAPET DETAIL REFER SEPARATE DRAWING.
DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
SCALE : 1/10 DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 PSC I-GIRDER
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND REINFORCEMENT DETAILS
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 1 OF 5
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09065
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/31/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G065_X.DWG


1 2 3 4
-
- - -

CL OF I-GIRDER

ZONE A = 1500(FIXED) ZONE B = 1500(FIXED) ZONE C = 3000(FIXED) ZONE D(VARIES)

END CROSS GIRDER


DOWEL BARS ALTERNATE ALTERNATE
MID CROSS GIRDER
DOWEL BARS

HALF PLAN VIEW B-B (INNER GIRDER)


SCALE : 1/20

1 2 3 4
- - -
-

CL OF I-GIRDER

ZONE A = 1500(FIXED) ZONE B = 1500(FIXED) ZONE C = 3000(FIXED) ZONE D(VARIES)


END CROSS GIRDER
DOWEL BARS

ALTERNATE MID CROSS GIRDER


DOWEL BARS

Ld Ld
ALTERNATE

HALF SECTION C-C (INNER GIRDER) FOR DOWEL BARS, REFER DRAWING NO.
SCALE : 1/20 DDCP2GMRL-DD-ELV-ST-DW-09072
1 2 3 4 DDCP2GMRL-DD-ELV-ST-DW-09073
- - -
-

CL OF I-GIRDER
MOTERA
STADIUM
STATION
(Ele.)

ZONE A = 1500(FIXED) ZONE B = 1500(FIXED) ZONE C = 3000(FIXED) ZONE D(VARIES) 1


Koteshwar
CH: 17563.252m
Road

Vishwakarma
CH: 2
19016.974m
College
MAHATMA 20
Mahatma
Mandir
CH: 39337.858m

KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
Tapovan
CH: 3

N
19994.376m
Circle

ROAD Narmada
CH: 4
20899.927m
Canal 12
Infocity
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

CH:
Sector
32791.432m

14
10A
MID CROSS GIRDER GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
END CROSS GIRDER
Juna 6
CH: Koba
23056.769m

Sachivalaya

15
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

DOWEL BARS
Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

DOWEL BARS
CH: 0.00m
GNLU

1
ALTERNATE

KEY PLAN

CH: 1749.00m
PDPU
2
Gift City
GIFT CITY

3
CH: 4605.861m

Ld

R0 First Issue MK PB MS 10/31/2020

REV. PARTICULARS DRN. CHD. VER. DATE

HALF SECTION D-D (INNER GIRDER) PROJECT NAME :


DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
SCALE : 1/20 MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 PSC I-GIRDER
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND REINFORCEMENT DETAILS
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 2 OF 5
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09066
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/31/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G066_X.DWG


1 2 3 4
- - - -

CL OF I-GIRDER

ZONE A = 1500(FIXED) ZONE B = 1500(FIXED) ZONE C = 3000(FIXED) ZONE D(VARIES)

ALTERNATE ALTERNATE
END CROSS GIRDER MID CROSS GIRDER
DOWEL BARS DOWEL BARS

HALF PLAN VIEW B-B (OUTER GIRDER)


SCALE : 1/20

1 2 3 4
- - -
-

CL OF I-GIRDER

ZONE A = 1500(FIXED) ZONE B = 1500(FIXED) ZONE C = 3000(FIXED) ZONE D(VARIES)

END CROSS GIRDER


DOWEL BARS ALTERNATE MID CROSS GIRDER
DOWEL BARS

Ld Ld
ALTERNATE

HALF SECTION C-C (OUTER GIRDER) FOR DOWEL BARS, REFER DRAWING NO.
DDCP2GMRL-DD-ELV-ST-DW-09072
SCALE : 1/20 DDCP2GMRL-DD-ELV-ST-DW-09073
1 2 3 4
- - -
-

CL OF I-GIRDER
MOTERA
STADIUM
STATION
(Ele.)

MAHATMA
1
Koteshwar
CH: 17563.252m
Road

ZONE A = 1500(FIXED) ZONE B = 1500(FIXED) ZONE C = 3000(FIXED) ZONE D(VARIES)


Mandir
CH: 39337.858m
20
Mahatma

Vishwakarma
CH: 2
19016.974m
College

KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
Tapovan
CH: 3

N
19994.376m
Circle

ROAD Narmada
CH: 4
20899.927m
Canal 12
Infocity
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

CH:
Sector
32791.432m

14
10A
GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
Juna 6
CH: Koba
23056.769m

MID CROSS GIRDER


Sachivalaya

15
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
END CROSS GIRDER
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU

1
DOWEL BARS DOWEL BARS
ALTERNATE
KEY PLAN

CH: 1749.00m
PDPU
2
Gift City
GIFT CITY

3
CH: 4605.861m

Ld

R0 First Issue MK PB MS 10/31/2020

REV. PARTICULARS DRN. CHD. VER. DATE


PROJECT NAME :
HALF SECTION D-D (OUTER GIRDER) DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
SCALE : 1/20
DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 PSC I-GIRDER
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND REINFORCEMENT DETAILS
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 3 OF 5
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09067
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/31/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G067_X.DWG


B
B - B
A -
B A -

- - -

ALTERNATE ALTERNATE

BAR MARK (2A) TO BE CHANGED


AS BAR MARK (2B) SHOWN
WHENEVER CONFLICT WITH PT CABLE

C C
- -

C C
- -

BAR MARK (5A) TO BE CHANGED


AS BAR MARK (5B) SHOWN BELOW
WHENEVER CONFLICT WITH PT
CABLE

D D
D - D -
- -

ALTERNATE
A ALTERNATE
-

SECTION 1-1 A

SECTION 2-2
-

SCALE : 1/10
SCALE : 1/10

MOTERA
STADIUM
STATION
(Ele.)

MAHATMA
1
Koteshwar
CH: 17563.252m
Road

Mandir
CH: 39337.858m
20
Mahatma

Vishwakarma
CH: 2
19016.974m
College

KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
Tapovan
CH: 3

N
19994.376m
Circle

ROAD Narmada
CH: 4
20899.927m
Canal 12
Infocity
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

CH:
Sector
32791.432m

14
10A
GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
Juna 6
CH: Koba
23056.769m

Sachivalaya

15
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU

1
KEY PLAN

CH: 1749.00m
PDPU
2
Gift City
GIFT CITY

3
CH: 4605.861m

R0 First Issue MK PB MS 10/31/2020

REV. PARTICULARS DRN. CHD. VER. DATE


PROJECT NAME :
DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 PSC I-GIRDER
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND REINFORCEMENT DETAILS
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 4 OF 5
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09068
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/31/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G068_X.DWG


REINFORCEMENT DETAIL
BAR SPACING
MARK DIA SHAPE
/ NOS.
B 1 T10 @150 700
- B
A
-
B B 300
- - -
2A T16 @300
A
- 2B T16 @300
ALTERNATE
3A T16 @150 600

3B T10 @150 500

3C T12 @150 500

4A T16 @150

4B T16 @150

4C T10 @300

C C C C 5A T10 @150
- - - -

5B T10 @150

6 T10 5 NO.

ALTERNATE ALTERNATE 7A T12 4 NO.

7B T12 4 NO.

7C T12 1 NO.

7D T12 1 NO.

8A T10 44 NO.

BAR MARK (5A) TO BE CHANGED BAR MARK (5A) TO BE CHANGED 8B T16 8 NO. 300
AS BAR MARK (5B) SHOWN BELOW AS BAR MARK (5B) SHOWN BELOW
WHENEVER CONFLICT WITH PT WHENEVER CONFLICT WITH PT 9 T10 @150
CABLE CABLE
10A T10 @150

10B T10 @150


D D
D - D - 11 T12 7 NO.
- -

ALTERNATE ALTERNATE 12A T16 7 NO. 300

12B T16 7 NO. 300


A A
-
- 13 T16 8 NO.

SECTION 3-3 SECTION 4-4 14 T12 16 NO.


SCALE : 1/10 SCALE : 1/10
15 T10 12 NO.

16 T10 6 NO.

17 T8 4 NO.

18 T10 8 NO.

19A T12 4 NO.

19B T10 2 NO.


500
20 T12 6 NO.

CONCRETE GRADE - M50


REINFORCEMENT GRADE - Fe500 D

MOTERA
STADIUM
STATION
(Ele.)

MAHATMA
1
Koteshwar
CH: 17563.252m
Road

39337.858m
CH:
Mandir
20

Mahatma

Vishwakarma
CH:
2

19016.974m
College

KOTESHWAR MANDIR
38138.299m
- 24
19
Sector
CH:

Tapovan
CH: 3
19994.376m
Circle
N

ROAD Narmada
CH: 4
20899.927m
12

Canal
Infocity
CH: 30280.842m

13
Sector
CH: -1
31557.503m
37100.644m
- 16
Sector
18
CH:

R0 First Issue MK PB MS 10/31/2020


Circle
28941.692m
Dholakuva

Koba
11

CH:
Circle
5

22050.557m
CH:

CH: 32791.432m
Sector14
10A

GNLU REV. PARTICULARS DRN. CHD. VER. DATE


10

Sachivalaya
36008.291m

Randesan
27786.821m
17

CH:
Juna
CH:

6
CH:Juna
23056.769m
Koba

15
Sachivalaya
CH: 33981.620m

Koba Gaam
7
CH: 24066.374m

9
Raysan
CH: 26414.16m

16
Akshardham
CH:
35110.363m

PROJECT NAME :
8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU
1

DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM


MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
KEY PLAN
CH: 1749.00m
PDPU

CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
3
Gift City
CH: 4605.861m
GIFT CITY DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 PSC I-GIRDER
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND REINFORCEMENT DETAILS
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 5 OF 5
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09069
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/31/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G069_X.DWG


REINFORCEMENT DETAIL-
375
BAR NO. DIA. SHAPE SPACING/NOS.
75 75 75 75 75

01 16 2 X 2 X 3 Nos.

75
2
1

75
-
-
1A 16 2 X 2 X 4 Nos.

375

75
1B 16 2 X 2 X 2 Nos.

75
1C 16 2 X 2 X 1 Nos.

75
1D 16 2 X 2 X 8 Nos.

LAYER-1 LAYER-1 02 16 2 X 4 Nos.


LAYER-2 LAYER-2
LAYER-3
MESH DETAIL - A 2A 16 2 X 2 X 4 Nos.
LAYER-3 SCALE : 1/10
LAYER-4 LAYER-4
2B 16 2 X 3 Nos.
LAYER-5 LAYER-5
LAYER-6 LAYER-6 2C 16 2 X 2 X 2 Nos.
LAYER-7 LAYER-7
2D 16 2 X 1 Nos.
LAYER-8 LAYER-8
LAYER-9 LAYER-9 2E 16 2 X 6 Nos.
LAYER-10 LAYER-10
LAYER-11 LAYER-11 2F 16 2 X 6 Nos.
LAYER-12 LAYER-12
03 16 L.V. L.V. 10 Nos.

JACK POSITION 04 16 @ 100C/C


600 (TYP.) 600 2 600 600
- DETAIL-A 05 20 3 x 4 Nos.

1 SECTIONAL VIEW OF END CROSS-GIRDER 5A 20 3 x 4 Nos.


- SCALE : 1/20
(BAR MARKED 7 & 8 NOT SHOWN FOR CLARITY)
06 25 3 x 4 Nos.
Ld
6A 25 3 x 4 Nos.

150
07 10 @ 150C/C
150
LAYER OVERLAP BARS
1 01 + 02 + 2B + 01 08 10 3 x 2 Nos.
2 1D 1A + 2A 2E + 2F 2A + 1A 1D
3 1D 1B + 2C 2F + 2E 2C + 1B 1D 09 8 16 NOS.
4 1C + 02 + 2D + 1C
5 1D 1B + 2C 2F + 2E 2C + 1B 1D
6 1D 1A + 2A 2E + 2F 2A + 1A 1D
7 01 + 02 + 2B + 01
8 1D 1A + 2A 2E + 2F 2A + 1A 1D
9
10 1D
01 + 02 + 2B + 01
1A + 2A 2E + 2F 2A + 1A 1D
TYP JUNCTION DETAIL
11 1D 05 + 5A 05 + 5A 5A + 05 1D (FOR BAR MARK 05, 5A, 06 & 6A)
12 1D 06 + 6A 06 + 6A 6A + 06 1D SCALE : 1/10

MOTERA
STADIUM
STATION
(Ele.)

MAHATMA
1
Koteshwar
CH: 17563.252m
Road

Mandir
CH: 39337.858m
20
Mahatma

Vishwakarma
CH: 2
19016.974m
College

KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
Tapovan
CH: 3

N
19994.376m
Circle

ROAD Narmada
CH: 4
20899.927m
Canal 12
Infocity
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
REFERENCE DRAWINGS :-

CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

CH:
Sector
32791.432m

14
10A
GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
Juna 6
CH: Koba
23056.769m

1. PRECAST I-GIRDER CONCRETE OUTLINE DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09054 & 09055.


Sachivalaya

15
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU

1
2. FOR GENERAL ARRANGEMENT OF SUPERSTRUCTURE DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09051 TO 09053.
3. FOR PRECAST I-GIRDER REINFORCEMENT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09065 TO 09069.
KEY PLAN

CH: 1749.00m
PDPU
2
4. FOR CAST-IN-SITU SLAB REINFORCEMENT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09075 TO 09077.
5. FOR DRAINAGE & PARAPET DETAIL REFER SEPARATE DRAWING. Gift City
GIFT CITY

3
CH: 4605.861m

SPACER BAR 25 DIA SPACER BAR 25 DIA


@ 1000 c/c
NOTES :-
@ 1000 c/c
1) CLEAR COVER TO ANY REINFORCEMENT : 40mm.
2) HYSD REINFORCEMENT BARS CONFORM TO IS : 1786 - GRADE Fe-500D.
3) ANCHORAGE LENGTH & LAP LENGTH (AS PER IRS-CBC-1999 (THIRD REVISION 2004) CLAUSE 15.9)
- MORE THAN 50% LAPPING SHALL NOT BE ALLOWED AT ANY SECTION.
- ANCHORAGE LENGTH = 41*D & LAP LENGTH = 58*D. WHERE D: DIAMETER OF SMALLEST BAR IN OVERLAP
MINIMUM CLEAR DISTANCE BETWEEN TWO ALTERNATE OVERLAPS = 0.3 TIMES THE LAP LENGTH. R0 First Issue MK PB MS 10/31/2020
4) LAPPING SHALL BE STAGGERED AND NOT MORE THAN 50% BARS SHALL
REV. PARTICULARS DRN. CHD. VER. DATE
BE LAPPED AT A SECTION. CONCRETE GRADE - M45
5) WHEREVER REINFORCEMENT FOULS WITH PT CABLE, REINFORCEMENT SHALL BE SUITABLY ADJUSTED. REINFORCEMENT GRADE - Fe500 D PROJECT NAME :
SECTION 1-1 SECTION 2-2 DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
SCALE : 1/10 SCALE : 1/10 CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 END DIAPHRAGM
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND REINFORCEMENT DETAILS
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 1 OF 2
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09072
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/31/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G072_X.DWG


REINFORCEMENT DETAIL-

BAR NO. DIA. SHAPE SPACING/NOS.

01 12 2 X 2 X 4 Nos.

1 1A 12 2 X 2 X 4 Nos.
-
2
-

1B 12 2 X 2 X 1 Nos.
L.V. L.V. L.V. L.V.
1C 12 2 X 2 X 1 Nos.

1D 12 2 Nos.

1E 12 2 Nos.
LAYER-1 LAYER-1
1F 12 2 X 2 X 2 Nos.
LAYER-2 LAYER-2
LAYER-3 LAYER-3
02 12 2 X 2 X 9 Nos.
LAYER-4 LAYER-4
LAYER-5 LAYER-5 2A 12 2 Nos.
LAYER-6 LAYER-6
2B 12 2 Nos.
LAYER-7 LAYER-7
LAYER-8 LAYER-8 03 25 3 X 4 Nos.
LAYER-9 LAYER-9
LAYER-10 LAYER-10 3A 25 3 X 4 Nos.

LAYER-11 LAYER-11 04 25 3 X 4 Nos.


LAYER-12 LAYER-12
4A 25 3 X 4 Nos.
L.V.
05 16 @ 100C/C

1
-
2 06 16 L.V. L.V. 16 Nos.
-

LAYER OVERLAP BARS


SECTIONAL VIEW OF MID CROSS-GIRDER 1 01+02+02+1A Ld
07 10
150
@ 150C/C
SCALE : 1/20 150
(BAR MARKED 7 & 8 NOT SHOWN FOR CLARITY) 2 1A+02+02+01
3 01+02+02+1A 08 10 3 x 2 x 2 Nos.
4 1A+02+02+01
5 01+02+02+1A
6 1A+02+02+01
7 01+02+02+1A
8 1F 1C + 1B 2A + 2B 1C + 1B 1F
9 1F+1D+02+02+1E+1F
10 1A+02+02+01
11 03 + 3A 03 + 3A 3A + 03
12 04 + 4A 04 + 4A 4A + 04

LEGEND:- TYP JUNCTION DETAIL


L.V. - LENGTH VARIES
(FOR BAR MARK 03, 3A, 04 & 4A)
SCALE : 1/10

REFERENCE DRAWINGS :- MOTERA


STADIUM
STATION
(Ele.)

MAHATMA
1
Koteshwar
CH: 17563.252m
Road

Mandir
CH: 39337.858m
20
Mahatma

1. PRECAST I-GIRDER CONCRETE OUTLINE DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09054 & 09055.


Vishwakarma
CH: 2
19016.974m
College

KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
Tapovan
CH: 3

N
19994.376m
Circle

2. FOR GENERAL ARRANGEMENT OF SUPERSTRUCTURE DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09051 TO 09053. ROAD Narmada
CH: 4
20899.927m
Canal 12
Infocity
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
3. FOR PRECAST I-GIRDER REINFORCEMENT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09065 TO 09069.

Sector18
CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

4. FOR CAST-IN-SITU SLAB REINFORCEMENT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09075 TO 09077.

CH:
Sector
32791.432m

14
10A
GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
Juna 6
CH: Koba
23056.769m

Sachivalaya

15
CH:
33981.620m

5. FOR DRAINAGE & PARAPET DETAIL REFER SEPARATE DRAWING.


7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU

1
NOTES :- KEY PLAN

CH: 1749.00m
PDPU
2
1) CLEAR COVER TO ANY REINFORCEMENT : 40mm. Gift City
GIFT CITY

3
CH: 4605.861m

2) HYSD REINFORCEMENT BARS CONFORM TO IS : 1786 - GRADE Fe-500D.


3) ANCHORAGE LENGTH & LAP LENGTH (AS PER IRS-CBC-1999 (THIRD REVISION 2004) CLAUSE 15.9)
SPACER BAR 25 DIA SPACER BAR 25 DIA - MORE THAN 50% LAPPING SHALL NOT BE ALLOWED AT ANY SECTION.
@ 1000 c/c @ 1000c/c - ANCHORAGE LENGTH = 41*D & LAP LENGTH = 58*D. WHERE D: DIAMETER OF SMALLEST BAR IN OVERLAP
MINIMUM CLEAR DISTANCE BETWEEN TWO ALTERNATE OVERLAPS = 0.3 TIMES THE LAP LENGTH.
4) LAPPING SHALL BE STAGGERED AND NOT MORE THAN 50% BARS SHALL
BE LAPPED AT A SECTION.
5) WHEREVER REINFORCEMENT FOULS WITH PT CABLE, REINFORCEMENT SHALL BE SUITABLY ADJUSTED.
R0 First Issue MK PB MS 10/31/2020

REV. PARTICULARS DRN. CHD. VER. DATE


CONCRETE GRADE - M45
REINFORCEMENT GRADE - Fe500 D PROJECT NAME :

SECTION 1-1
DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
SECTION 2-2 MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
SCALE : 1/10 SCALE : 1/10
DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 INTERMEDIATE DIAPHRAGM
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND REINFORCEMENT DETAILS
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 2 OF 2
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09073
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/31/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G073_X.DWG


1 2
-
-

3
-

C
-

C
-

ALT. WITH 2

Ld Ld
TYP. TYP.

ALT. WITH 2A

A Ld Ld A
-
TYP. TYP.
-

B
-

B
-

1 2
-
-

3
-

PLAN VIEW
(BAR MARK 2D, 2E & 11 NOT SHOW FOR CLARITY)
SCALE : 1/50
1 2 3
- -
ALTERNATE -

ALTERNATE LEGEND:-

BAR ON TOP FACE

DETAIL X BAR ON BOTTOM FACE

MOTERA
STADIUM
STATION
(Ele.)

MAHATMA
1
Koteshwar
CH: 17563.252m
Road

Mandir
CH: 39337.858m
20
Mahatma

Vishwakarma
CH: 2
19016.974m
College

ALTERNATE KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
ALTERNATE
Tapovan
CH: 3

N
19994.376m
Circle

ROAD Narmada
CH: 4
20899.927m
Canal 12
Infocity
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

CH:
Sector
32791.432m

14
10A
GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
Juna 6
CH: Koba
23056.769m

Sachivalaya

15
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU

1
1 2
KEY PLAN

CH: 1749.00m
PDPU
3

2
- -

-
Gift City
GIFT CITY

3
CH: 4605.861m

SECTION A-A
(BAR MARK 2D & 2E NOT SHOW FOR CLARITY)
SCALE : 1/50

NOTES :-
1. ALL H.Y.S.D. REINFORCEMENT BARS SHALL CONFIRM TO IS:1786 GRADE Fe-500D. REFERENCE DRAWINGS :-
R0 First Issue MK PB MS 10/31/2020
2. MINIMUM CLEAR COVER TO ANY REINFORCEMENT BARS SHALL BE 40MM. UNLESS OTHERWISE SPECIFIED. 1. FOR GENERAL NOTES REFER DRAWING DDCP2GMRL-DD-ELV-ST-DW-11001 &11002.
REV. PARTICULARS DRN. CHD. VER. DATE
3. ANCHORAGE LENGTHS = 41Ø, LAP LENGTH=58Ø,WHERE Ø IS THE DIAMETER OF LESSER DIAMETER OF BAR LAPPED. 2. FOR PRECAST I-GIRDER CONCRETE OUTLINE DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09054 & 09055. CONCRETE GRADE - M50
3. FOR GENERAL ARRANGEMENT OF SUPERSTRUCTURE DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09051 TO 09053. PROJECT NAME :
4. LAPPING SHALL BE STAGGERED AND NOT MORE THAN 50% BAR SHALL BE LAPPED AT A SECTION. REINFORCEMENT GRADE - Fe500 D
4. FOR PRECAST I-GIRDER REINFORCEMENT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09065 TO 09069. DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
5. WHEREVER DRAINAGE FOULS WITH REINFORCEMENT OF SLAB, REINFORCEMENT SHALL BE SUITABLEY ADJUSTED. MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
6. THE REINFORCEMENT DETAILING AND BAR BENDING SCHEDULE PROPOSED IN THESE DRAWINGS ARE INDICATIVE ONLY. 5. FOR CAST-IN-SITU CROSS GIRDER REINFORCEMENT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09072 & 09073. CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
THE CONTRACTOR SHALL PREPARE DETAILED BAR BENDING SCHEDULES. 6. FOR DRAINAGE & PARAPET DETAIL REFER SEPARATE DRAWING. DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 CAST-IN-SITU SLAB
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND REINFORCEMENT DETAILS
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 1 OF 3
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09075
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/31/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G075_X.DWG


75
75

HALF SECTION 1-1


SCALE : 1/10

75
75

SPECIAL NOTES:-
1. THIS DRAWING IS FOR A TYPICAL SPAN OF 28M.
2. THIS DRAWING IS APPLICABLE TO 4 I-GIRDER ARRANGEMENT IN SPANS.

MOTERA
STADIUM
STATION
(Ele.)

MAHATMA
1
Koteshwar
CH: 17563.252m
Road

Mandir
CH: 39337.858m
20
Mahatma

Vishwakarma
CH: 2
19016.974m
College

KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
Tapovan
CH: 3

N
19994.376m
Circle

ROAD Narmada
CH: 4
20899.927m
Canal 12
Infocity
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

CH:
Sector
32791.432m

14
10A
GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
CH:
Juna 6
CH: Koba
23056.769m

Sachivalaya

15
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

CH: 0.00m
GNLU

1
KEY PLAN

CH: 1749.00m
PDPU
2
Gift City
GIFT CITY

3
CH: 4605.861m

PRECAST PRECAST
I-GIRDER REINF. I-GIRDER REINF.

NOTES :-
HALF SECTION 2-2
1. ALL H.Y.S.D. REINFORCEMENT BARS SHALL CONFIRM TO IS:1786 GRADE Fe-500D. REFERENCE DRAWINGS :- SCALE : 1/10
R0 First Issue MK PB MS 10/31/2020
2. MINIMUM CLEAR COVER TO ANY REINFORCEMENT BARS SHALL BE 40MM. UNLESS OTHERWISE SPECIFIED. 1. FOR GENERAL NOTES REFER DRAWING DDCP2GMRL-DD-ELV-ST-DW-11001 &11002. REV. PARTICULARS DRN. CHD. VER. DATE
3. ANCHORAGE LENGTHS = 41Ø, LAP LENGTH=58Ø,WHERE Ø IS THE DIAMETER OF LESSER DIAMETER OF BAR LAPPED. 2. FOR PRECAST I-GIRDER CONCRETE OUTLINE DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09054 & 09055. CONCRETE GRADE - M50
3. FOR GENERAL ARRANGEMENT OF SUPERSTRUCTURE DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09051 TO 09053. PROJECT NAME :
4. LAPPING SHALL BE STAGGERED AND NOT MORE THAN 50% BAR SHALL BE LAPPED AT A SECTION. REINFORCEMENT GRADE - Fe500 D
DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
5. WHEREVER DRAINAGE FOULS WITH REINFORCEMENT OF SLAB, REINFORCEMENT SHALL BE SUITABLEY ADJUSTED. 4. FOR PRECAST I-GIRDER REINFORCEMENT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09065 TO 09069. MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
6. THE REINFORCEMENT DETAILING AND BAR BENDING SCHEDULE PROPOSED IN THESE DRAWINGS ARE INDICATIVE ONLY. 5. FOR CAST-IN-SITU CROSS GIRDER REINFORCEMENT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09072 & 09073. CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
THE CONTRACTOR SHALL PREPARE DETAILED BAR BENDING SCHEDULES. 6. FOR DRAINAGE & PARAPET DETAIL REFER SEPARATE DRAWING. DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 CAST-IN-SITU SLAB
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND REINFORCEMENT DETAILS
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 2 OF 3
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09076
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/31/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G076_X.DWG


REINFORCEMENT DETAIL-

BAR NO. DIA. SPACING/NOS. SHAPE

01 16 @ 100 C/C

1A 20 2 X 16 NOS.

1B 16 @ 100 C/C

02 16 @ 200 C/C
ALT. WITH 2A

2A 12 @ 200 C/C
ALT. WITH 02

2B 12 @ 100 C/C

2C 10 2 X 4 NOS.

2D 10 4 X 11 NOS. VARIES VARIES

575 1500 2E 10 2 X 3 X 3 NOS.

HALF SECTION 3-3 03 10 @ 100 C/C VARIES


VARIES

SCALE : 1/10
3A 20 @ 100 C/C VARIES

VARIES
04 12 @ 150 C/C

05 12 @ 150 C/C

VARIES
06 12 @ 150 C/C

VARIES
07 10 @ 150 C/C

08 10 @ 150 C/C

PRECAST
SECTION B-B 09 10 @ 150 C/C
VARIES

I-GIRDER REINF. SCALE : 1/10


2000
10 16 @ 150 C/C 100

575 1500 100


10A 10 @ 150 C/C 300

100
100
10B 10 @ 150 C/C OR
100 150

100 100
300 11 16 2 X 4 NOS. OR
100 100

SPECIAL NOTES:-
1. THIS DRAWING IS FOR A TYPICAL SPAN OF 28M.
2. THIS DRAWING IS APPLICABLE TO 4 I-GIRDER ARRANGEMENT IN SPANS.

SECTION C-C
MOTERA
STADIUM
STATION
(Ele.)

MAHATMA
1
Koteshwar
CH: 17563.252m
Road

Mandir
CH: 39337.858m
20
Mahatma

Vishwakarma
CH: 2
19016.974m
College

KOTESHWAR MANDIR

CH: 38138.299m
- 24
Sector19
SCALE : 1/10
Tapovan
CH: 3

N
19994.376m
Circle

575 1500 REFERENCE DRAWINGS :- ROAD Narmada


CH: 4
20899.927m
Canal 12
Infocity
CH: 30280.842m

13
Sector
-1
CH: 31557.503m

CH: 37100.644m
- 16
Sector18
1. FOR GENERAL NOTES REFER DRAWING DDCP2GMRL-DD-ELV-ST-DW-11001 &11002.

CH: 28941.692m
11 Circle
Dholakuva
CH: Koba 5
22050.557m
Circle

CH:
Sector
32791.432m

14
10A
GNLU 10

Sachivalaya
36008.291m
Randesan
27786.821m

17
CH:

Juna
2. FOR PRECAST I-GIRDER CONCRETE OUTLINE DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09054 & 09055.

CH:
Juna 6
CH: Koba
23056.769m

Sachivalaya

15
CH:
33981.620m

7
Koba
CH: 24066.374m
Gaam

9
Raysan
26414.16m
CH:

Akshardham
16
CH: 35110.363m

8
GNLU
CH: 24977.483m

3. FOR GENERAL ARRANGEMENT OF SUPERSTRUCTURE DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09051 TO 09053.


CH: 0.00m
GNLU

1
4. FOR PRECAST I-GIRDER REINFORCEMENT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09065 TO 09069.
5. FOR CAST-IN-SITU CROSS GIRDER REINFORCEMENT DRAWING NO. DDCP2GMRL-DD-ELV-ST-DW-09072 & 09073. KEY PLAN

CH: 1749.00m
PDPU
2
6. FOR DRAINAGE & PARAPET DETAIL REFER SEPARATE DRAWING. GIFT CITY
Gift City

3
CH: 4605.861m

NOTES :-
1. ALL H.Y.S.D. REINFORCEMENT BARS SHALL CONFIRM TO IS:1786 GRADE Fe-500D.
2. MINIMUM CLEAR COVER TO ANY REINFORCEMENT BARS SHALL BE 40MM. UNLESS OTHERWISE SPECIFIED.
3. ANCHORAGE LENGTHS = 41Ø, LAP LENGTH=58Ø,WHERE Ø IS THE DIAMETER OF LESSER DIAMETER OF BAR LAPPED.
4. LAPPING SHALL BE STAGGERED AND NOT MORE THAN 50% BAR SHALL BE LAPPED AT A SECTION.
5. WHEREVER DRAINAGE FOULS WITH REINFORCEMENT OF SLAB, REINFORCEMENT SHALL BE SUITABLEY ADJUSTED.
6. THE REINFORCEMENT DETAILING AND BAR BENDING SCHEDULE PROPOSED IN THESE DRAWINGS ARE INDICATIVE ONLY.
R0 First Issue MK PB MS 10/31/2020
THE CONTRACTOR SHALL PREPARE DETAILED BAR BENDING SCHEDULES.
REV. PARTICULARS DRN. CHD. VER. DATE
CONCRETE GRADE - M50
DETAIL X REINFORCEMENT GRADE - Fe500 D
PROJECT NAME :
DETAIL DESIGN CONSULTANCY SERVICES FOR EXTENSION OF NORTH-SOUTH CORRIDOR FROM
MOTERA STADIUM (CH: 17343.443) TO MAHATMA MANDIR (CH: 39484.360) AND EXTENDED GNLU-GIFT
SCALE : 1/10 CORRIDOR ELEVATED VIADUCT & ELEVATED METRO- RAIL STATIONS- (TWENTY TWO NUMBERS)
DETAILED DESIGN INCLUDING VIADUCT PORTION WITHIN THE STATION AND TRANSITION SPANS ON EITHER SIDE OF
THE STATIONS AND DEPOT CUM WORKSHOP AT INDRODA UNDER METRO RAIL PROJECT - PHASE 2
This Drawings/Design are property of GMRC. The Drawings/Design VIADUCT STRUCTURE DRAWINGS : NOTES : EMPLOYER : PROOF CHECK CONSULTANT DETAIL DESIGN CONSULTANT (DDC) CONTRACT ID : GMRC/DDC/ELEV-VDCT-STNS & DEPOT/N-S/PH-2, Dated 02-07-2019
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS OTHERWISE
cannot be issued by any other person, firm, authority or used by SPECIFIED.
GUJARAT METRO RAIL CORPORATION (GMRC) DRAWING NAME/TITLE : SIZE :
consultant for any other purpose/project without prior written 2. ALL DIMENSIONS ARE TO BE READ AND NOT MEASURED. LIMITED BLOCK-1, FIRST FLOOR, KARMYOGI ELEVATED VIADUCT
3. ANY DISCREPANCIES MUST BE BROUGHT TO THE NOTICE OF THE CONSULTANT BEFORE BHAVAN,BEHIND NIRMAN BHAWAN, SECTOR-10A
permission of GMRC. The consultant shall indemnify GMRC against A1
EXECUTION OF THE WORK AT SITE. GANDHINAGAR - 382010 CAST-IN-SITU SLAB
all claims arisen due to infringement of any right protected by design, 4. ANY DEVIATION FROM APPROVED LAND PLANS TO BE BROUGHT TO THE NOTICE OF THE
INDIA
copyright or other intellectual property rights. CONSULTANT BEFORE EXECUTION. LKT ENGINEERING CONSULTANTS LTD CONSORTIUM OF SYSTRA, SA FRANCE AND REINFORCEMENT DETAILS
5. ANY DEVIATION FROM BOQ DESCRIPTION AND QUANTITY TO BE BROUGHT TO THE NOTICE OF SYSTRA MVA CONSULTING (INDIA) PVT. LTD.
THE CONSULTANT BEFORE EXECUTION. LOCATION:
6. THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURE, THE DESIGN AND DRAWINGS AS CERTIFIED Vatika Mindscapers, Tower-B, 12/3 Floor 9th, 10th
ISSUED FOR AND SUBMITTED BY THE DETAILED DESIGNER & 11th, Mathura Road, NH-2, Sector-27/D, SHEET NO. 3 OF 3
STRUCTURAL, PLUMBING & FIRE FIGHTING, ELECTRICAL AND TRAFFIC MANAGEMENT DRAWING NO : DDCP2GMRL-DD-ELV-ST-DW-09077
DRAWINGS. CONSULTANT HAVE BEEN PROOF CHECKED Faridabad, Haryana-121013 REV NO. R0
CONCEPT DRAWING TENDER DRAWING LEGENDS : ABBREVIATIONS : BY M/S LKT AND RECOMMENDED TO MEGA
SCALE :
DGM Sr.DGM DGM/ DGM/ FOR APPROVAL. THE DESIGN COMPLIES WITH DATE : 10/31/2020
PRELIMINARY DRAWING FINAL DRAWING(GAD) (Lift & Escalator) (SINGALLING) MANAGER MANAGER MANAGER JGM DBR AND ALL RELEVANT CODAL PROVISIONS. THE RESPONSIBILITY OF CONTROL, IT IS CERTIFIED THAT DETAILED DESIGN PREPARED IS COMPLIED WITH THE TERM AND CONDITION OF CONTRACT AND DBR
FIRST SUBMISSION GFC (SYS) DESIGN ARCH (ARCH) CHECK AND VERIFICATION OF ACCURACY PROVISIONS. DDC OWN FULL RESPONSIBILITY FOR DESIGN ADEQUACY AND MEETING FUNCTIONAL, PERFORMANCE AND
NO OBJECTION CORRECTNESS, COMPLETENESS, OPERATIONAL REQUIREMENT INCLUDING CONSIDERATION FOR INTERFACE REQUIREMENT OF OTHER CONCERNED
A1(594x841mm +2mm)

INTEGRATION AND FULL COMPLIANCE DESIGNER/CONTRACTOR AND COMPLIANCE TO STANDARDS, NORMS, SAFETY AND STATUARY RULES & REGULATIONS.
REFERENCE DESIGN DOCUMENT : REVISION AND RESUBMISSION REQUIRED
OF CONTRACT PROVISIONS IN RESPECT
OF DESIGN ANALYSIS AND DRAWING RESTS
GM(Telecom) GM(Traction) CGM(S&T) CGM(SYM) CGM(P&D) WITH THE DDC
REFERENCE DRAWING :
MV HJ PB MS JR
Sign : Sign : CHECKED BY INTERFACE ENGG. DESIGNED BY CHECKED BY APPROVED BY ISSUED BY

FILE NAME: L:\SYSTRA_INDIA\CAD_PROJECTS\IN01T19A03 - GMRL DDC\09G\WORKDIR\09G077_X.DWG