You are on page 1of 11

LGaN 50W / 100W / 200W Outdoor BUC

Appendix B – PRE-SHIP TEST DATA SHEET


Supplement to CAT Station Data Revision-
Model Number Serial Number Plinear Frequency Range

LGAN / LGK0-11 231578368 200W 950-1700 MHz

Unit Options 13.750-14.500 GHz

BUC Int Ref LNB Bias T Bias T Gain Date Tested By

YES YES YES 10.6 dB Oct. 03, 2023 C. Hernandez

9.4 Pre-Ship Testing


(Attach CAT Data Sheet)
See automated test station data sheet for:
 Gain
 Spectral Regrowth
 Third Order Intermodulation
 Customer Attenuation
 Power Monitor

9.4.1 VSWR (Return Loss)


Step Item Specification Condition Measurement Status

1 Input 14 dB R.L. 950 MHz 1700 MHz 15.8 PASS


2 Output 18 dB R.L. 13.75 GHz 14.5 GHz 19.8 PASS

9.4.2 Noise Figure


Step Item Specification Condition Measurement Status

1 Start Freq 20.0 dB max @ Max Gain GHz 17.2 PASS


Mid Freq 20.0 dB max @ Max Gain GHz 16.0 PASS
End Freq 20.0 dB max @ Max Gain GHz 16.5 PASS

TP-0020665 Rev A Production Acceptance Test Procedure Page 35 of 40


Copyright © Comtech EF Data Corporation, 2023. All rights reserved.
WARNING - This document contains U.S.-origin data, the re-transfer of which is restricted by
the Export Administration Act and Export Administration Regulations (15 C.F.R. 770, et seq.)
LGaN 50W / 100W / 200W Outdoor BUC

9.4.3 Spurious
Step Item Specification Condition Measurement Status

1 Line Related < -50.0 dBc 14125 MHz -52.7 PASS


Carrier Related < -60.0 dBc @ Rated Power 14125 MHz -71.8 PASS
Non-Carrier
< -60.0 dBm 14125 MHz -75.4 PASS
Related
RFLO Leakage < -25.0 dBm 12800 MHz -41.0 PASS

9.4.4 Mute
Step Item Specification Condition Measurement Status

1 < -60.0 dBc 14125 MHz 76.2 PASS

9.4.5 Power Consumption


Step Item Specification Condition Measurements Status

2 Power Line V - 180 V to 264 V


No RF/Prated 209 209 PASS
(Vrms if AC) 48 VDC
Power Line A - <1700 W/Vrms
No RF/Prated 5.95 7.59 PASS
(Arms if AC)
Power Line kW - <1.300 / <1.700
No RF/Prated 1.19 1.53 PASS
(kW if AC)
Power Line kVA - < 1.300 / <1.700
No RF/Prated 1.24 1.58 PASS
(N/A if DC unit)
Power Line PF - >0.95
No RF/Prated .96 .97 PASS
(N/A if DC unit)

TP-0020665 Rev A Production Acceptance Test Procedure Page 36 of 40


Copyright © Comtech EF Data Corporation, 2023. All rights reserved.
WARNING - This document contains U.S.-origin data, the re-transfer of which is restricted by
the Export Administration Act and Export Administration Regulations (15 C.F.R. 770, et seq.)
LGaN 50W / 100W / 200W Outdoor BUC

9.4.6 Communication and Discrete Control


Step Item Specification Condition Measurement Status
2 RS-485 Verify √ PASS

3 RS-232 Verify √ PASS

4 a. IP Address IPA=192.168.1.4.24 Verify √ PASS

b. IP Gateway IPG=192.168.1.5 Verify √ PASS

c. Local/Remote
LRS=3 Verify √ PASS
Setting

d. MAC Address Verify 0006B004DAD0 PASS

5 a. Date & Time DAT, TIM Verify √ PASS

b. Serial Number SNO Verify √ PASS


c. Exit Redundancy ESW=0 Verify √ PASS
Mode (ESW = 0)
d. Equipment Equipment odometer
Verify √ PASS
odometer set at zero (EOD=0)

e. Maximum
MOP=1 Verify √ PASS
operating point
cleared (MOP=1)
6 FSK > 10.0 dB Verify √ PASS

Set FFF=1, pin M to


pin K is a short
7 Summary Fault Relay Verify √ PASS
Set FFF=0, pin M to
pin K is open

Voltage on pin-R to
8 Level of voltage Verify √ PASS
pin K is 24V +/-10%

9.4.7 Redundancy Check


Step Specification Condition Measurement Status

Verify proper redundancy operation using units/cables/switches, etc.


9 Verify PASS
planned for shipment.

TP-0020665 Rev A Production Acceptance Test Procedure Page 37 of 40


Copyright © Comtech EF Data Corporation, 2023. All rights reserved.
WARNING - This document contains U.S.-origin data, the re-transfer of which is restricted by
the Export Administration Act and Export Administration Regulations (15 C.F.R. 770, et seq.)
LGaN 50W / 100W / 200W Outdoor BUC

9.4.8 Waveguide Pressure Check (If Applicable)


Step Specification Condition Measurement Status

5 psi for 30 minutes (< 0.5 psi drop after 0.5 hour, or no visible drop
3 √ PASS
after 5 minutes)

9.4.9 Unit Pressure Check


Step Specification Condition Measurement Status

30 inches H20 (1.08 psi) for 15 minutes (< 1.0 in. H20 drop after 15
3 √ PASS
minutes)

9.4.9 LNB Bias Check (If Option Included)


Step Specification Condition Measurement Status

1a Gain Level (10.0 dB +/- 2 dB) 10.6 PASS

1b Gain Flatness (+/- 1.0 dB) 1.67 PASS

1c Online Input Return Loss (< -15 dB) 15.3 PASS

1d Offline Isolation (> 55 dB) 91.1 PASS

2 10 MHz LNB Ref Osc Level (0.0 dBm +/- 5 dBm) -2.38 PASS

2 Check Spurious Signals Verify √ PASS

3 LNB Bias V (17.5 +/- 1V) 18.3V PASS

3 LNB Current Bias (500.0 mA +/- 25 mA) 517 mA PASS

4 LNB Bias Calibration and Window Check Verify √ PASS

9.4.10 10 MHz External and Internal Reference Check and Setup (If Option
Included)

Step Specification Condition Measurement Status

1 REF Control Value and Output Frequency 0539 14.500000003 PASS

2 Verify 10 MHz external lock, Correct M&C rdg -5 dBm to +5 dBm Verify PASS

3 Verify 5 MHz external lock, Correct M&C rdg -5 dBm to +5 dBm Verify PASS

TP-0020665 Rev A Production Acceptance Test Procedure Page 38 of 40


Copyright © Comtech EF Data Corporation, 2023. All rights reserved.
WARNING - This document contains U.S.-origin data, the re-transfer of which is restricted by
the Export Administration Act and Export Administration Regulations (15 C.F.R. 770, et seq.)