Renewal Parts Manual


Discovery RF180

Discovery RF180
Renewal Parts Manual
5793734-1EN

Revision 7
© 2023 GE Healthcare
All rights reserved

1
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

This page is blank.

2
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Revision history
Revision Date Reason for change

01 March
1 Initial release
2018

01 August
2 Spare parts update
2019

01 January
3 Spare parts update
2020

01 January
4 Spare parts update
2021

01 January New spare parts added, additional feedback


5
2022 from field

New monitor, New video chain and PID HW,


01 new collimator and webcam, tilting inverter,
6 December transformer terminals, grid locking device
2022 updated, FM581 driver change, New Dual LAN
board

01
FL4 panel and cables, table shims, NVDIA
7 september
board T400, full OTS handle
2023

Manufacturer

GENERAL MEDICAL MERATE S.p.A.


Via Partigiani, 25
24068 Seriate (BG) - Italy
Tel. +39 035 45 25 311
Fax +39 035 29 77 87 / 29 95 37
www.gmmspa.com - service@gmmspa.com

Distributor

GE Medical Systems, SCS


283, rue de la Minière,78530 Buc, France

The original version of this publication was drafted in Italian and will be referred to for any controversy regarding interpretation of
the corresponding versions, translated into several foreign languages.

The contents of this publication may not be reproduced in any manner with any electronic or mechanical means. It cannot be
distributed in any manner without written authorization issued by the manufacturer.

The manufacturer reserves the right to modify/update this document without notice.

3
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

This page is blank.

4
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

0. Layout

Item # GE Part # GMM Part # Description Additional Information

1 - - TABLE -

2 - - DIGITAL SYSTEM -

3 - - GENERATOR – X-RAY TUBE -

4 - - OTS KALOS TYPE -

5.1. - - MAVIG SUSPENSION: PORTEGRA 2 / CEILING COLUMN 360° -

5.2. - - MAVIG SUSPENSION: PORTEGRA 2 / EXTENSION - SPRING ARM NOT ELECTRICAL -

6 - - WALLSTAND -

5
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

1. Table

Item # GE Part # GMM Part # Description Additional Information

1.01. ELEVATION/TILTING GROUP

1.02. SID GROUP

1.03. X-RAY TUBE GROUP

1.04. MAIN BEAM GROUP

1.05. SFD GROUP

1.06. TABLETOP GROUP

1.07. COMPRESSOR GROUP

1.08. CONSOLE GROUP

1.09. ACCESSORY

1.10. GE INTERCOM DEVICE

1.11. CABLES

1.12. KIT SERVICE

6
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

1.01 Elevation tilting group

Item # GE Part # GMM Part # Description Additional Information

1 5369098-2 96207 MICROSWITCH TYPE AM1108-11

NEW CALIBRATION NEEDED IN CASE OF


2 5795306 97196 TABLE ELEVATION TRANSLATOR 900mm
REPLACEMENT (TABLE SM)

BRING A SW VERSION PRELOADED. MOVEMENT NEED


TO BE CALIBRATED AS FOR TABLE SM. PLEASE VERIFY
THE SW VERSION INTALLED ON THE DRIVER USING
THE CAHPTER “AKD KOLLAMORGEN DRIVER
3A 5795307 166105 DRIVER KOLLMORGEN AKD FOR ELEVATION MOVEMENT
FIRMWARE UPDATE” IN THE TABLE SM. IT MUST BE
THE 1-19-00-002 OR HIGHER. IF LOWER PLEASE FIND
THE CORRECT VERSION IN THE FOLDER C:\SW
SETUP.AND FLASH IT.

IF 5904272 NCCC TYPE IS NOT AVAILABLE, ORDER


DRIVER KOLLMORGEN AKD FOR ELEVATION MOVEMENT (NCCC
3B 5904272 84811 NBCC TYPE 5795307, DO NOT CHANGE THE SW
MODEL)
LOADED ON IT.

4 5781388 97106 MOTOR GEAR MRIV64UO3AF080B 4230/400

5 5696085-2 R96130A BELT POLY-V 340J 12 KIT

6 5565413-2 95866 SUPPORT MICRO

7 5642172-2 95891A ROLLER

8 5484453-2 127905 ELECTROMAGNETIC BRAKE

NEW CALIBRATION NEEDED IN CASE OF


9 5369131-2 96191 POTENZIOMETER 10 TURNS - 1K - TYPE AL1710M - 1K
REPLACEMENT (TABLE SM)

10 5484425-2 165063 POWER SUPPLY 24V PRO MAX3 120W 5A

11 5369105-2 99076 OMRON RELAY TYPE LY2-24VDC

12 5493505-2 97041 THREE PHASE RECTIFIERS BRIDGE 26A 60V

7
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # GE Part # GMM Part # Description Additional Information

THIS BOARD BRING A SW VERSION PRELOADED. THE


CURRENT SW VERSION SHOULD BE IN THE PATH
13 5369109-2 R96243 CLISIS MAIN CPU BOARD C:\SWSETUP. CHECK THE TABLE SM IN ORDER TO
RESTORE THE CORRECT ONE. ALL MOVEMENT AND
OPTION CALIBRATION AND SETUP NEEDED.

14 5369110-2 R96244 CLISIS INTERFACE BOARD

15A 5696142-2 122618 DRIVER YASKAWA FOR TILTING MOVEMENT MOVEMENT TO BE CALIBRATED AS IN TABLE SM

CHECK JOBCARD T060 IN ORDER TO REPLACE THIS


15B 5934540 84819 TILTING INVERTER REPLACEMENT KIT
DRIVER ON IB.

16 5493600-2 R166299_2 DRIVER FM 581 15/55 FOR PANEL MOVEMENT BRING SW PRELOADED

17 5757015-2 96229A CURTAIN PROTECTION

18 5864800 R162185 BIG LEFT COVER ON THE BACK (TABLE MAIN STRUCTURE)

19 5864802 R162186 BIG RIGHT COVER ON THE BACK (TABLE MAIN STRUCTURE)

20 5864801 81822 POSTERIOR TABLE COVER (TABLE MAIN STRUCTURE)

21 5864803 95852 UPPER MAIN STRUCTURE COVER

22 5864804 82762 FRONT RIGHT MAIN STRUCTURE COVER FOR GE

23 5864805 82763 FRONT LEFT MAIN STRUCTURE COVER FOR GE

24 5864806 160049 LOWER CENTRAL TRASMISSION COVER

25 5864807 160050 UPPER CENTRAL TRASMISSION COVER

26 5883781 96846A MAIN INPUT TRASFORMER

BE AWARE SOME SPECIAL TOOL ARE MANDATORY


27 5883782 97574 ELEVATION ENDLESS SCREWS NEEDED TO PERFORM THE REPLACEMENT OF THIS
ITEM

NOT SHOWN 5369106-2 125257 SET OF FUSES SET OF TABLE FUSES

NEW CALIBRATION OF ELEVATION AND TILTING


NOT SHOWN 5831522 82613 ELEVATION MOTOR AKM44G-ACD2CA00 B'LESS MOTOR 400VAC
MOVEMENT NEEDED AS FOR TABLE SM

NOT SHOWN 5875107 84803 ANCHOR SCREWS KIT FOR BASEPLATE INSTALLATION

NOT SHOWN 5821103 03588 KEY UNI 6614-A 10x8x40 FOR TILTING MOTOR SHAFT

NOT SHOWN 5936162 82327 BASE PLATE SHIM FOR TABLE STRUCTURE 1 MM

NOT SHOWN 5936163 82328 BASE PLATE SHIM FOR TABLE STRUCTURE 2 MM

NOT SHOWN 5936164 82329 BASE PLATE SHIM FOR TABLE STRUCTURE 5 MM

8
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # 10 - 5484425-2 Item # 11 - 5369105-2 Item # 12 - 5493505-2 Item # 13 - 5369109-2 Item # 14 - 5369110-2

Item # 15A - 5696142-2 Item # 15B - 5934540 Item # 16 - 5493600-2

9
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

1.02 SID group

Item # GE Part # GMM Part # Description Additional Information

1 5781393 160211 ALUMINIUM PLATE COLUMN MAIN BEAM

2 5781391 160212 CHAIN JOINT

3 5643006-2 R96157 FFD MOTOR

4 5483873-2 97154 TUBE STAND SID TRANSLATOR NEW CALIBRATION NEEDED IN CASE OF REPLACEMENT (TABLE SM)

5 5536334-2 97142 SID TRANSLATOR EXTENSION

6 5751160-2 96133 CABLES SUPPORT CHAIN

7 5695325-2 96167 LEFT COVER

8 5695326-2 96159 RIGHT COVER

9 5801520 82769 COLUMN FRONT COVER (GE COLOR)

10 5369099-2 167891 MICROSWITCH TYPE AM1108-12 90°

11 5369098-2 96207 MICROSWITCH TYPE AM1108-11

12 5493601-2 R166299_1 DRIVER FM 581 15/55 FOR SID MOVEMENT BRING SW PRELOADED

NEW CALIBRATION NEEDED OF COMPRESSION FORCE IN CASE OF REPLACEMENT


13 5466302-2 R96240B TUBE STAND CONTROL BOARD AND IF COMPRESSOR OPTION PRESENT (TABLE SM) - PROCEDURE SHIPPED WITH
THE PART.

14 5864685 82780 COLUMN BACK COVER JOIN

15 5864808 96170 COVER AND FFD CABLE CHAIN SUPPORT

16 5864693 03799 CIRCULAR BEARING FOR SID ROD SLIDE

10
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # 12 - 5493601-2 Item # 13 - 5466302-2

11
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

1.03 X-ray tube group

Item # GE Part # GMM Part # Description Additional Information

1 5565260-2 97512 COLLIMATOR RAILS

THIS BOARD BRING A SW VERSION PRELOADED. THE CURRENT SW


VERSION SHOULD BE IN THE PATH C:\SWSETUP. CHECK THE TABLE SM
KIT AL COLLIMATOR CONTROL BOARD
2A 5642536-2 122737 IN ORDER TO RESTORE THE CORRECT ONE. FFD MOVEMENT
(CPU+TOUCHSCREEN)
CALIBRATION NEEDED. COLLIMATOR BLADES AND X-RAY FIELD
SHOULD BE CHECKED. OUT OF ORDER.

THIS KIT CAN BE INSTASLLED JUST FROM R7.3 DUE TO INTERNAL


COMPONENT CHANGE. THIS BOARD BRING A SW VERSION
KIT AL COLLIMATOR CONTROL BOARD PRELOADED. THE CURRENT SW VERSION SHOULD BE IN THE PATH
2B 5883790 84814
(CPU+TOUCHSCREEN) FROM R7.3 C:\SWSETUP. CHECK THE TABLE SM IN ORDER TO RESTORE THE
CORRECT ONE. FFD MOVEMENT CALIBRATION NEEDED. COLLIMATOR
BLADES AND X-RAY FIELD SHOULD BE CHECKED.

3A 5642842-2 97543A TAPE AND LASER for COLLIMATOR -AL

3B 5827131 R97931 MEASURE TAPE SOLO for COLLIMATOR -AL

4A 5834639 165059 WEBCAM HP HD2300 - WEBCAM SOLO COMPATIBLE WITH SYSTEM TILL SN 01340

THIS KIT INCLUDE USB AND PROCEDURE IN CASE YOU MUST REPLACE
4B 5864342 R165044B USB CAMERA LOGITECH - CAMERA SOLO OLD MODEL HP HD2300 MODEL. IF REPLACEING AN EXSTING
LOGITECH THOSE ITEM ARE USELESS

4C 5923552 R161478 IP WEBCAM INTEGRATED for colimator R161489 NOT BACKWARD COMPATIBLE WITH USB WEBCAM.

5A 5781947 160193 LEFT/RIGHT TUBE COVER WITHOUT COMPRESSOR

5B 5781948 160326 LEFT/RIGHT TUBE COVER WITH COMPRESSOR

6 5565241-2 122334 LED KIT FOR COLLIMATOR MODEL AL

7 5781949 07559 MICRO SWITCH TYPE V-165-1A5

8 5781950 R81870 BRAKE MECHANISM FOR X-RAY TUBE

12
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # GE Part # GMM Part # Description Additional Information

CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR REPLACEMENT.


OUT OF ORDER. THIS ASSEMBLY BRING A SW VERSION PRELOADED.
AUTOMATIC COLLIMATOR WITH MOTORIZED THE CURRENT SW VERSION SHOULD BE IN THE PATH C:\SWSETUP.
9A 5795308 R82753
FILTER CHECK THE TABLE SM IN ORDER TO RESTORE THE CORRECT ONE. FFD
MOVEMENT CALIBRATION NEEDED. COLLIMATOR BLADES AND X-RAY
FIELD SHOULD BE CHECKED.

TO BE ORDERED IF R82753 NOT AVAILABLE AT STOCK. THIS


COLLIMATOR CAN BE INATALLED ON SYSTEM AT LEAST R7.3 RELEASE.
THIS ASSEMBLY BRING A SW VERSION PRELOADED. THE CURRENT SW
AUTOMATIC COLLIMATOR WITH MOTORIZED
9B 5883791 R82753A VERSION SHOULD BE IN THE PATH C:\SWSETUP. CHECK THE TABLE SM
FILTER FROM R7.3
IN ORDER TO RESTORE THE CORRECT ONE. FFD MOVEMENT
CALIBRATION NEEDED. COLLIMATOR BLADES AND X-RAY FIELD
SHOULD BE CHECKED.

THIS SPARE COLLIMATOR DO NOT INCLUDE IP WEBCAM AND ITS


COVER, YOU NEED TO RECOVER IT FROM THE CURRENTLY INSTALLED.
THIS COLLIMATOR CAN BE INSATALLED ON SYSTEM THAT USE IP
AUTOMATIC COLLIMATOR WITH MOTORIZED INTEGRATED WEBCAM. THIS ASSEMBLY BRING A SW VERSION
9C 5923554 R161489
FILTER SUPPORTING IP WEBCAM PRELOADED. THE CURRENT SW VERSION SHOULD BE IN THE PATH
C:\SWSETUP. CHECK THE TABLE SM IN ORDER TO RESTORE THE
CORRECT ONE. FFD MOVEMENT CALIBRATION NEEDED. COLLIMATOR
BLADES AND X-RAY FIELD SHOULD BE CHECKED.

10 5805836 160195 UPPER COVER FOR X-RAY TUBE

11 5805837 160196A BOTTOM COVER FOR X-RAY TUBE

12 5827128 82758 TUBE ROTATION HANDLE

12A 5883783 82755A TUBE ROTATION HANDLE ASSEMBLY

13 5118676 08665 FAN FOR X-RAY TUBE

POWER SUPPLY MODULE FOR WEBCAM SILEX


14 5838872 R165027
SERVER

CONFIGURED WITH DEFAULT IP 192.168.101.2. MORE INFO IN THE


15 5838873 R165043 SILEX SERVER FOR WEBCAM SIGNAL
DIGITAL SM

16 5839142 160192 REAR TUBE ARM COVER ASSEMBLY

17 5853026 R160194 FRONT TUBE COVER WITH GE LOGO

LATERAL LEFT TUBE COVER WITH DISCOVERY


18 5853027 R160197
LOGO

LATERAL RIGHT TUBE COVER WITH DISCOVERY


19 5853028 R160198
LOGO

10 + 11 +
17 + 18 + 5923556 R160144 FULL TUBE COVER ASSEMBLY
19

13
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

1.04 Main beam group

Item # GE Part # GMM Part # Description Additional Information

1 5781951 97135A BOTTOM COVER MAIN BEAM

2 5781953 95933 BOTTOM COVER MAIN BEAM (FOR CABLES)

BRING A SW VERSION PRELOADED. MOVEMENT NEED TO BE CALIBRATED


AS FOR TABLE SM. PLEASE VERIFY THE SW VERSION INTALLED ON THE
DRIVER KOLLMORGEN AKD FOR COLUMN DRIVER USING THE CAHPTER “AKD KOLLAMORGEN DRIVER FIRMWARE
3A 5795311 166104
MOVEMENT UPDATE” IN THE TABLE SM. IT MUST BE THE 1-19-00-002 OR HIGHER. IF
LOWER PLEASE FIND THE CORRECT VERSION IN THE FOLDER C:\SW
SETUP.AND FLASH IT.

DRIVER KOLLMOGEN AKD FOR COLUMN IF 5883799 NCCC TYPE IS NOT AVAILABLE, ORDER NBCC TYPE 5795311,
3B 5883799 84810
MOVEMENT (NCCC MODEL) DO NOT CHANGE THE SW LOADED ON IT.

BRING A SW VERSION PRELOADED. MOVEMENT NEED TO BE CALIBRATED


AS FOR TABLE SM. PLEASE VERIFY THE SW VERSION INTALLED ON THE
DRIVER USING THE CAHPTER “AKD KOLLAMORGEN DRIVER FIRMWARE
4A 5795310 166103 DRIVER KOLLMORGEN AKD FOR SFD MOVEMENT
UPDATE” IN THE TABLE SM. IT MUST BE THE 1-19-00-002 OR HIGHER. IF
LOWER PLEASE FIND THE CORRECT VERSION IN THE FOLDER C:\SW
SETUP.AND FLASH IT.

DRIVER HOLLMORGEN FOR SFD MOVEMENT IF 5883800 NCCC TYPE IS NOT AVAILABLE, ORDER NBCC TYPE 5795310,
4B 5883800 84809
(NCCC MODEL) DO NOT CHANGE THE SW LOADED ON IT.

BRING A SW VERSION PRELOADED. MOVEMENT NEED TO BE CALIBRATED


AS FOR TABLE SM. PLEASE VERIFY THE SW VERSION INTALLED ON THE
DRIVER KOLLMORGEN AKD FOR LONGITUDINAL DRIVER USING THE CAHPTER “AKD KOLLAMORGEN DRIVER FIRMWARE
5A 5781955 166106
TABLETOP MOVEMENT UPDATE” IN THE TABLE SM. IT MUST BE THE 1-19-00-002 OR HIGHER. IF
LOWER PLEASE FIND THE CORRECT VERSION IN THE FOLDER C:\SW
SETUP.AND FLASH IT.

DRIVER KOLLMORGEN AKD FOR LONGITUDINAL IF 5883801 NCCC TYPE IS NOT AVAILABLE, ORDER NBCC TYPE 5781955,
5B 5883801 84812
TABLETOP MOVEMENT (NCCC MODEL) DO NOT CHANGE THE SW LOADED ON IT.

6 5789022 82334 LINEAR BEARING FOR COLUMN

14
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # GE Part # GMM Part # Description Additional Information

7 5781959 82380 LINEAR BEARING FOR SFD

8 5820794 41028 PLASTIC WHITE CAPS FOR COVER

9 5838307 R160166 FRONT LEFT COVER WITH SAFETY SWITCH

10 5838308 R160167 FRONT RIGHT COVER WITH SAFETY SWITCH

11 5864810 81843 SINGLE DRIVER COVER

12 5864811 81837 DOUBLE DRIVER COVER

13 5864812 81885 COLUMN CABLE CHAIN

14 5696452 96134 SFD CABLE CHAIN

15 5864698 81834 SFD CABLE CHAIN SUPPORT

16 5805627 95902 BACK RIGHT COLUMN CHAIN COVER

17 5805628 95899 BACK LEFT COLUMN CHAIN COVER

18 5883785 81838 LEFT CABLE CHAIN SUPPORT METAL BRACKET THAT HOLD THE CABLE CHAIN

POTENZIOMETER 10 TURNS - 1K - TYPE AL1710M - BOTH FOR COLUMN AND SFD. NEEDED NEW CALIBRATION AS FOR TABLE
19 5369131-2 96191
1K SM.

Item # 8 - 5820794 Item # 19 - 5369131-2

15
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

1.05 SFD group

Item # GE Part # GMM Part # Description Additional Information

1 5781961 R81774 KEYBOARD FRONT COVER

2 5781962 162096 SFD KEYBOARD GE

3 5118699 70545 SFD EMERGENCY SWITCH, TYPE MG9512203

4 5795312 R96263 CARBON FIBER GRID R12/L80/F150

5 5781964 07565 MICROSWITCH

6 5795313 82681 UPPER SFD COVER

7 5369099-2 167891 MICROSWITCH TYPE AM1108-12 90°

9 5781967 R81541 SELF LOCKING DEVICE

10 5781969 48626 LOCKING THOOTH

11 5369103-2 95407 CROUZET MICROSWITCH TYPE 83.106.0 B9 IW2

12 5493510-2 95405 AUTOFOCUSING DEVICE GEARBOX

THIS BOARD BRING A SW VERSION


PRELOADED. THE CURRENT SW VERSION
13 5466234-2 R96241 SFD CPU BOARD SHOULD BE IN THE PATH C:\SWSETUP. CHECK
THE TABLE SM IN ORDER TO RESTORE THE
CORRECT ONE.

14 5493596-2 122718 SFD KEYBOARD INTERFACE BOARD

15 5118706 39650A TABLETOP GEAR MOTOR

16 5781971 162138 PINION M=1.5 Z=15

17 5781970 82624 GRID AUTO FOCUSING WIRE ROPE

18 5827134 81723 SFD BOTTOM COVER

16
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # GE Part # GMM Part # Description Additional Information

NEED TO BE ORDERED IN CAS YOU REPLACE


19 5827139 R82635 METAL BRACKET SUPPORT FOR PIXIUM FL4343 DETECTOR WITH SCREWS
AN RF DETECTOR WITH AN FL

20 5864814 81725 UPPER BACK SFD COVER

IT DOESN’T INCLUDE ROLLER BEARINGS AND


21 5923557 R82616 TABLETOP LATERALMOVEMENT SUPPORT
FRONT COVER

Item # 13 - 5466234-2 Item # 14 - 5493596-2

17
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

1.06 Tabletop group

Item # GE Part # GMM Part # Description Additional Information

1 5369098-2 96207 MICRO SWITCH TYPE AM1108-11

IF YOU WANT TO USE THE TABLETOP IN FLAT


2 5781982 81832 LONGITUDINAL TABLETOP (WHITE COLOR) CONFIGURATION YOU MUST ORDER 2X ITEM 9 “METAL
ADESIVE STRIPE”

3 5781949 07559 MICRO SWITCH TYPE V-165-1A5

NEEDED NEW CALIBRATION OF LATERAL MOVEMENT AS


4 5781981 167054 POTENTIOMETER WITH TRANSLATOR 900 MM
FOR TABLE SM.

NEEDED NEW CALIBRATION OF LATERAL MOVEMENT AS


5 5795316 81899 VIRTUAL SCANNING KIT FOR TABLE SM. IF NEW INSTALLATION OF THE KIT IT MUST
BE ABLED AND SET UPPED IN THE FIELD INTERFACE.

ENTIRE LONGITUDINAL FLAT TABLETOP ASSEMBLY (WHITE


6A 5802250 160065
COLOR)

ENTIRE LONGITUDINAL TABLETOP ASSEMBLY (WHITE


6B 5838305 161312
COLOR) - CONCAVE VERSION

7 5827136 82615 FOOT SAFETY SWITCH COVER

8 5838306 82655 SQUARE SMALL TOP COVER OF THE TABLE ARM

9 5838804 81485 METAL ADESIVE STRIPE ON TABLETOP END X1

IR PHOTOSENSOR FOR OPERATOR DETECT BEHIND CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR
10 5838805 167228
TABLETOP REPLACEMENT

11 5853746 81856 TABLETOP MYLAR PROTECTION 2460 MM LONG

12 5864815 82614 TABLETOP ARM SLIDING COVER

13 5864887 44606 RIGHT END CAP TABLETOP

14 5864888 44607 LEFT END CAP TABLETOP

18
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # GE Part # GMM Part # Description Additional Information

CHECK JOBCARD MANUAL FOR REPLACEMENT


15 5883786 R82741 LONGITUDINAL GEARMOTOR
PROCEDURE. JOBCARD NUMBER T022.

THIS ITEM CONTAIN A FULL TABLETOP ON A PALLET WITH


NOT TWO SET OF TROLLEYES INCLUDED. THE SECOND TROLLY
5883202 83105 ENTIRE TABLETOP ON TROLLEY FOR TOTAL REPLACEMENT
SHOWN SHOULD BE USED IN ORDER TO RETURN THE DEFECTIVE
TABLETOP.

19
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

1.07 Compressor group

Item # GE Part # GMM Part # Description Additional Information

1 5799559 82277 COMPRESSOR GEAR MOTOR NEEDED CHECK OF COMPRESSION FORCE AS DESCRIBED IN TABLE SM

2 5781964 07565 MICRO SWITCH TYPE AVT3452

3 5838874 R160323 WHOLE COMPRESSOR ARM NEEDED CHECK OF COMPRESSION FORCE AS DESCRIBED IN TABLE SM

4 5132187 42145 COMPRESSOR CONE ALONE

5 5864816 160276 FRONT COVER COMPRESSOR ROD

6 5864817 160327 COMPRESSOR ARM COVER ASSEMBLY

TO BE ORDER IF COMPRESSOR NOT PRESENT ON THE SYSTEM. IF


NOT SHOWN 5923558 84801 TOMOBAR WITHOUT COMPRESSOR ASSEMBLY
ORDERED ON SYSTEM BUILD BEFORE SN 01176 ORDER ALSO PN 162189

20
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

1.08 Console group

Item # GE Part # GMM Part # Description Additional Information

1 5781972 R162152 GE GLASS CONSOLE

2 5795314 162165 JOYSTICK ASSEMBLY WITH CABLES FOR COLLIMATOR SHUTTERS

3 5781973 165056 JOYSTICK ASSEMBLY WITH CABLES FOR DFF/INCIDENCE CONTROL JOYSTICK CALIBRATION NEEDED AS FOR TABLE SM

JOYSTICK ASSEMBLY WITH CABLES FOR TUBE LONG.


4 5781974 165055 JOYSTICK CALIBRATION NEEDED AS FOR TABLE SM
SCANNING/TABLE TOP LATERAL CONTROL

JOYSTICK ASSEMBLY WITH CABLES FOR TILTING/ELEVATION


5 5781975 165057 JOYSTICK CALIBRATION NEEDED AS FOR TABLE SM
CONTROL

6 5118253 70547A X-RAY BUTTON ASSEMBLY

7 5781976 56681 EMERGENCY BUTTON

8 5781977 166007 CONSOLE CONTROL BOARD

THIS BOARD BRING A SW VERSION PRELOADED. THE


CURRENT SW VERSION SHOULD BE IN THE PATH
9 5781983 166002A CONSOLE CPU BOARD C:\SWSETUP. CHECK THE TABLE SM IN ORDER TO
RESTORE THE CORRECT ONE. WHOLE JOYSTICK
CALIBRATION AND SETUP NEEDED.

10 5795315 167067 ON/OFF BUTTONS

Item # 1 - 5781972 Item # 2 - 5795314 Item # 3 - 5781973 Item # 4 - 5781974 Item # 5 - 5781975

21
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # 6 - 5118253 Item # 7 - 5781976 Item # 8 - 5781977 Item # 9 - 5781983 Item # 10 - 5795315

22
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

1.09 Accessory

Item # GE Part # GMM Part # Description Additional Information

1 5786406 44226B HANDGRIPS

2 5786407 44225A SHOULDER RESTS

3A 5828621 44227B COMPRESSION BELT

3B 5786409 71481B RESTRAINT STRAP

4 5786410 82720 INTRAVEANUOS INFUSION SUPPORT

5 5786411 82721 ARM SUPPORT

6 5786412 44229A LEG SUPPORTS

7 5786413 82722 SAFETY ARM HOLDER

9 5786415 81450A HEAD SUPPORT

10 5786417 82723 PAPER SUPPORT

11 5786418 44230A CASSETTE SUPPORT

12A 5493491-2 97007A SINGLE FOOTSWITCH PEDAL - CONTROL ROOM

12B 5838213 161315 DOUBLE FOOTSWITCH PEDAL - CONTROL ROOM

12C 5838216 R167440 DOUBLE FOOTSWITCH CONTACT AND CABLES - CONTROL ROOM

13 5829829 96052B DOUBLE FOOTSWITCH PEDAL - EXAM ROOM

14 5464029-2 97088 EXTERNAL XRAY HANDSWITCH WITH CABLE FOR CONSOLE

15 5781978 90221A STANDARD FOOTREST GREY SURFACE

“LEFT” INDICATE THE SIDE


15A 5940312 80831 FOOTREST LEFT FIXATION ASSEMBLY INSTALLING THE FOOTREST AND
FRONTLY FACING THE TABLETOP

23
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # GE Part # GMM Part # Description Additional Information

“RIGHT” INDICATE THE SIDE


15B 5940313 80830 FOOTREST RIGHT FIXATION ASSEMBLY INSTALLING THE FOOTREST AND
FRONTLY FACING THE TABLETOP

16 5786420 96071 MATRESS FOR TABLETOP

17 5838807 82152A INTERCOM DEVICE SEE ALSO GE INTERCOM CHAP 10.1

18 5883787 162258 ARM LATERAL HOLDER

NOT SHOWN 5864886 161574 WIFI DETECTOR HOLDER WITH GRID

24
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

1.10 GE Intercom device

GMM Additional
Item # GE Part # Description
Part # Information

1 5861330 CLARSON PUBLIC IV INTERCOM CONSOLE

2 5861333 CLARSON SURFACE MOUNTED LOUDSPEAKER

3 5861334 CLARSON OMNIDIRECTIONAL MICROPHONE EM 258

4 5861331 CLARSON CONSOLE MICROPHONE

NOT SHOWN 5861338 POWER CABLE EU, 2M, FOR GPP10 POWER SUPPLY, WITH PRIMARY ADAPTER

NOT SHOWN 5861339 POWER CABLE USA, 2M, FOR GPP10 POWER SUPPLY, WITH PRIMARY ADAPTER

NOT SHOWN 5861335 CLARSON POWER SUPPLY AND PRIMARY ADAPTER KIT

NOT SHOWN 5861332 CLARSON CENTRAL UNIT - HUB

NOT SHOWN 5861336 SET OF CABLES, KAT5E- RJ45 MALE/MALE- 1X 30 CM AND 1X 3 M AND 2X 2 M AUDIO CABLE

NOT SHOWN 5464032-2 POWER CABLE UK, 2M, FOR GPP10 POWER SUPPLY, WITH PRIMARY ADAPTER

25
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

1.11 Cables
Additional
Item # GE Part # GMM Part # Description
Information

NOT SHOWN 5494128-2 96212A CONSOLE CABLE 15MT

NOT SHOWN 5494001-2 96534A X-RAY INTERLOCK CABLE 15MT

NOT SHOWN 5786421 165012 PWS AND EMERGENCY CABLE 15MT

NOT SHOWN 5838806 97054A PWS CABLE FOR IQ GENERATOR

NOT SHOWN 5565259-2 96460 CONTROL TABLE GROUND CABLE (6MMQ - 15MT)

NOT SHOWN 5494081-2 96267A ELEVATION MICRO SWITCH E POTENZIOMETER CABLE

NOT SHOWN 5494080-2 96268A TILT MICRO SWITCH E POTENZIOMETER CABLE

NOT SHOWN 5786422 96269B TILTING MOTOR POWER CABLE

NOT SHOWN 5786423 96270A BRAKE CABLE OF TILTING MOTOR

NOT SHOWN 5795340 167102 ELEVATION MOTOR POWER & RESOLVER CABLE FOR DRIVER AKD

NOT SHOWN 5795341 167103 COLUMN MOTOR POWER & RESOLVER CABLE FOR DRIVER AKD

NOT SHOWN 5795342 167104 SFD MOTOR POWER & RESOLVER CABLE FOR DRIVER AKD

NOT SHOWN 5786431 167052 LONGITUDINAL TABLETOP MOTOR POWER CABLE FOR DRIVER AKD

NOT SHOWN 5786432 167053 LONGITUDINAL TABLETOP MOTOR RESOLVER CABLE FOR DRIVER AKD

NOT SHOWN 5494046-2 96246A COLUMN MICRO SWITCH CABLE

NOT SHOWN 5484543-2 96539A COLUMN CONTROL CABLE

NOT SHOWN 5494092-2 96247A SFD CABLE

NOT SHOWN 5494085-2 96248A COLUMN POWER CABLE

NOT SHOWN 5494060-2 96249A LONGITUDINAL SENSORS CABLE

NOT SHOWN 5494059-2 96250A SFD POWER CABLE

NOT SHOWN 5494083-2 96255A COLLIMATOR CABLE

NOT SHOWN 5786433 167021 CLISIS - COMPRESSOR CABLE #1

NOT SHOWN 5853749 167232 CLISIS – COILED COMPRESSOR CABLE FOR COMPRESSOR MOTION

NOT SHOWN 5786434 167024 TBT E.O.T CABLE

NOT SHOWN 5786435 167027 TBT LATERAL MOTOR POWER CABLE

NOT SHOWN 5786436 97726A COLUMN LONGITUDINAL AC POWER CABLE FOR DRIVER AKD

NOT SHOWN 5786437 97727A SFD LONGITUDINAL AC POWER CABLE FOR DRIVER AKD

NOT SHOWN 5786438 167030 LONGITUDINAL TABLETOP AC POWER CABLE FOR DRIVER AKD

NOT SHOWN 5786439 97728B COLUMN DC POWER CABLE FOR DRIVER AKD

NOT SHOWN 5786440 97729B SFD DC POWER CABLE FOR DRIVER AKD

NOT SHOWN 5786441 167031 LONGITUDINAL TABLETOP DC POWER CABLE FOR DRIVER AKD

NOT SHOWN 5786442 97674A SCAN MOTION CAN CABLE FOR DRIVER AKD

NOT SHOWN 5494043-2 96540A CAN CABLE #1

NOT SHOWN 5494044-2 96541A CAN CABLE #2

NOT SHOWN 5786443 96396 SFD KEYBOAD CABLE

NOT SHOWN 5786444 96767A TBT - FOOT SAFETY CABLE

NOT SHOWN 5786445 97325A VIRTUAL SCANNING CABLE

NOT SHOWN 5786446 167026 FOOT SAFETY MICROSWITCH CABLE

NOT SHOWN 5786447 167055 LONGITUDINAL TABLETOP SAFETY CABLE

NOT SHOWN 5786448 167056 LATERAL TABLETOP SAFETY CABLE

26
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Additional
Item # GE Part # GMM Part # Description
Information

NOT SHOWN 5494058-2 96351A DIGITAL SY. CAN BUS CABLE TABLE TO MAIN CONTROLLER

NOT SHOWN 5805293 65017 DIGITAL SY. CAN BUS CABLE MAIN CONTROLLER TO PID/INSIDE

NOT SHOWN 5786449 96361A TUBE ROTATION ENABLE CABLE

NOT SHOWN 5494045-2 96363A TUBE ROTATION POWER CABLE

NOT SHOWN 5484544-2 96576 CLISIS - FFD DRIVER CABLE

NOT SHOWN 5795343 167060A X-RAY LIGHT CABLE ON TUBE

NOT SHOWN 5786450 97662A WEBCAM ETHERNET CABLE (15MT)

NOT SHOWN 5786451 57430 INTERCOM CABLE (10MT)

NOT SHOWN 5494041-2 97145A CONSOLE CABLE (21MT)

NOT SHOWN 5494061-2 97146A X-RAY INTERLOCK CABLE (21MT)

NOT SHOWN 5795344 167203 PWS & EMERGENCY CABLE (21MT)

NOT SHOWN 5494084-2 97148 CONTROL TABLE GROUND CABLE (6MMQ - 21MT)

NOT SHOWN 5130868 55786 X-RAY HOUSING ANODE (21MT)

NOT SHOWN 5130867 55782 X-RAY HOUSING THERMAL

NOT SHOWN 5786452 55797 X-RAY HOUSING FAN (21MT)

NOT SHOWN 5786453 49558 DAP CHAMBER (25MT)

NOT SHOWN 5130866 55783 X-RAY HOUSING GROUND (21MT)

NOT SHOWN 5466187-2 95764 16 MT. HT CABLES PAIR

NOT SHOWN 5466188-2 18877 20 MT. HT CABLES PAIR

NOT SHOWN 5795338 95765 24 MT. HT CABLES PAIR

NOT SHOWN 5838212 57385 POWER SUPPLY CABLE FOR DVD MASTER DICOM

NOT SHOWN 5853748 121048A CABLE FOR VERTICAL WALL STAND POTENCIOMENTER SYNCRHO WITH OTS

NOT SHOWN 5864697 167556 LAN CABLE FOR OTS COMMUNICATION EXTENSION

NOT SHOWN 5864696 97588 LAN TO LAN CABLE JOIN

NOT SHOWN 5867860 57464 A AND B EXTENSION CABLE FOR MAIN MONITOR CONNECTION (KVMRX-I50) - 20MT

CHECK GMM PN
ON INSTALL
NOT SHOWN 5922401 167695 FERRITE 74271221S
MANUAL FOR
DETAILS

CHECK GMM PN
ON INSTALL
NOT SHOWN 5922403 167697 FERRITE 74271131S
MANUAL FOR
DETAILS

NOT SHOWN 5923559 167443 I/O CABLE TO CM6 BETWEEN MAIN CONTROLLER AND GENERATOR CM6

NOT SHOWN 5923560 167442 I/O CABLE TO CM8 BETWEEN MAIN CONTROLLER AND GENERATOR CM8

NOT SHOWN 5923553 167601 IP CAMERA COLLIMATOR AL CABLE

NOT SHOWN 5923058 57512 DISPLAYPORT CABLE

NOT SHOWN 5923561 79379 DETECTOR OPTICAL LINK CABLE

NOT SHOWN 5923562 05118 AEC CHAMBER CABLE

NOT SHOWN 5923563 167036 DIGITAL GENERATOR ETHERNET CABLE

NOT SHOWN 5130846 56232 ACCESS POINT CABLE

NOT SHOWN 5936158 57539 THALES DETECTOR POWER CABLE FOR FL4 PANEL

NOT SHOWN 5936159 41522 NETWORK CABLE CAT.5 RJ45 CROSSED FOR FL4 DETECTOR CONNECTION

NOT SHOWN 5936160 57546 SYNCHRO CABLE FOR FL4 DETECTOR

27
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

1.12 Kit service


Item # GE Part # GMM Part # Description Additional Information

NOT SHOWN 5464032-2 121000 EXTERNAL XRAY HANDSWITCH WITH CABLE FOR CPI GEN

NOT SHOWN 5474728-2 45549 10MM AL FILTER

NOT SHOWN 5464030-2 45540 21MM AL FILTER

NOT SHOWN 5565436-2 97731 CABLE FOR COLLIMATOR CALIBRATION - AL COLLIMATOR

NOT SHOWN 5493526-2 126965A SPECIAL ALLEN KEYS FOR COLLIMATOR

NOT SHOWN 5805738 34162 SPRAY OMNIKOTE 451

NOT SHOWN 5795333 56759 CONSOLE, THREEPHASE, SFD SERVICE CABLE (RS232 F/F)

NOT SHOWN 5804524 30673 ETS SCREWS SET

NOT SHOWN 5822155 39708 HYSTER SILICON SPRAY

NOT SHOWN 5805739 40251 GREASE SYSTEM GBM2ALMoS2 AREXON

NOT SHOWN 5823202 161254 CONTRKOR FLUID H1 SPRAY- KLUBER

NOT SHOWN 5827138 121041A KALOS SERVICE CABLE

THIS CABLE IS USED IN ORDER TO


CONFIGURE THE READOUT OF A NEW
NOT SHOWN 5883789 166061 SIKO MAGNETIC SENSOR SERVICE CABLE SIKO SENSOR ON AN EXISTING
MAGNETIC POSITION BAND OF KALOS
OTS.

NOT SHOWN 5922404 166278 FERRITES KEY TO OPEN THE FERRITES

28
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

2. Digital system

01_LEFT_SIDE 02_BACK_SIDE

Item # GE Part # GMM Part # Description Additional Information

2.1. GROUP 1A-1B – PIXIUM RF4343 DETECTOR UNIT

2.2. GROUP 3 – AEC CHAMBERS

2.3. DAP CHAMBERS

2.4. GROUP 4 – GENERAL AND DETECTOR POWER UNIT

2.5. GROUP 5 – IMAGE PROCESSOR UNITE PID INSIDE

2.6. GROUP 6 – MAIN CONTROLLER MODULE

2.7. GROUP 9 – MONITOR

2.8. GROUP 8, 11, 13 – CABINET AND CONSOLE DEVICES

29
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # GE Part # GMM Part # Description Additional Information

2.9. GROUP 21 – PIXIUM WIFI DETECTOR UNIT

30
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

2.1 Group 1a/1b - PIXIUM RF4343 Detector Unit

Item # GE Part # GMM Part # Description Additional Information

TRIXELL DETECTOR PIXIUM


1+3+5 5475448-2 49397A RF4343 WITH PU UNIT F3/V3 CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR REPLACEMENT
GENERATION

TRIXELL DETECTOR PIXIUM CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR REPLACEMENT FILL AND SEND THE
1A 5642243-2 49395 RF4343 - F3 GENERATION (RF REPORT FOR THE FAILED PART AS EXPLAINED IN TB5464. WITHOUT IT GE CAN'T CLAIM
DETECTOR) WARRANTY AND BE REFUNDED.

CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR REPLACEMENT. IF YOU ARE


TRIXELL DETECTOR PIXIUM REPLACING AN F3 DECTOR BEFORE FMI 10946 DEPLOYMENT CONTACT YOUR SERVICE
1B 5848552 160790 RF4343 - F4 GENERATION (RF SUPPORT ( RSE/RSL FOR EU , TSE’S FOR US ) FOR QUICKWINS SW CHECK. FILL AND
DETECTOR) SEND THE REPORT FOR THE FAILED PART AS EXPLAINED IN TB5464. WITHOUT IT GE
CAN'T CLAIM WARRANTY AND BE REFUNDED.

DETECTOR PIXIUM RF4343 – F4 CHECK JOBCARD D044 (PN 5793733-1EN) FILL AND SEND THE REPORT FOR THE
1C 5922400 160790A GENERATION (FW REV.C) CHECK FAILED PART AS EXPLAINED IN TB5464. WITHOUT IT GE CAN'T CLAIM WARRANTY AND
JOBCARD D044 BE REFUNDED.

CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR REPLACEMENT FILL AND SEND THE
TRIXELL DETECTOR PIXIUM
2 5566092-2 49582 REPORT FOR THE FAILED PART AS EXPLAINED IN TB5464. WITHOUT IT GE CAN'T CLAIM
RF4343FL
WARRANTY AND BE REFUNDED.

CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR REPLACEMENT FILL AND SEND THE
2A 5936157 164321 PIXIUM FL4 DETECTOR (NO PU) REPORT FOR THE FAILED PART AS EXPLAINED IN TB5464. WITHOUT IT GE CAN'T CLAIM
WARRANTY AND BE REFUNDED.

CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR REPLACEMENT. FILL AND SEND THE
TRIXELL DETECTOR PIXIUM
2+4+5 5566090-2 49524A REPORT FOR THE FAILED PART AS EXPLAINED IN TB5464. WITHOUT IT GE CAN'T CLAIM
RF4343FL WITH PU UNIT - FL/V3
WARRANTY AND BE REFUNDED.

31
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # GE Part # GMM Part # Description Additional Information

THIS PU IS USABLE WITH RF THALES DETECTORS PN 5642243-2 OR 5848552. IF OUT OF


STOCK USE 5867604. CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR
PROCESSING UNIT PIXIUM RF4343 REPLACEMENT (US USE JUST RF DETECTORS). IF OUT OF STOCK USE 5867604. ORDER
3A 5762963 49396A
- F3/V3 WITH HDD HD ALSO PN 5922398 IN ORDER TO INSTALL LATEST VERSION FOR GRAB IMAGE PROBLEM
FIX. FILL AND SEND THE REPORT FOR THE FAILED PART AS EXPLAINED IN TB5464.
WITHOUT IT GE CAN'T CLAIM WARRANTY AND BE REFUNDED.

CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR REPLACEMENT (US USE JUST RF
DETECTORS). THIS PU IS USABLE WITH RF THALES DETECTORS PN 5642243-2 OR
PROCESSING UNIT PIXIUM RF4343
3B 5867604 49396B 5848552. ORDER ALSO PN 5922398 IN ORDER TO INSTALL LATEST VERSION FOR GRAB
– (F3,F4)/V3 WITH SSD HD
IMAGE PROBLEM FIX. FILL AND SEND THE REPORT FOR THE FAILED PART AS
EXPLAINED IN TB5464. WITHOUT IT GE CAN'T CLAIM WARRANTY AND BE REFUNDED.

PROCESSING UNIT PIXIUM RF4343 COMPATIBLE ONLY WITH RF_F3/4 DETECTOR CHECK JOBACRD D043 FOR
3C 5922399 49396C - F3/V3 WITH SSD DISK- SW REPLACEMENT PROCEDURE. FILL AND SEND THE REPORT FOR THE FAILED PART AS
REV3.1 EXPLAINED IN TB5464. WITHOUT IT GE CAN'T CLAIM WARRANTY AND BE REFUNDED.

CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR REPLACEMENT. IF OUT OF STOCK


PROCESSING UNIT PIXIUM RF4343
4A 5762964 49583A USE 5865067. FILL AND SEND THE REPORT FOR THE FAILED PART AS EXPLAINED IN
- FL/V3 WITH HDD HD
TB5464. WITHOUT IT GE CAN'T CLAIM WARRANTY AND BE REFUNDED.

CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR REPLACEMENT. FILL AND SEND THE
PROCESSING UNIT PIXIUM RF4343
4B 5865067 49583B REPORT FOR THE FAILED PART AS EXPLAINED IN TB5464. WITHOUT IT GE CAN'T CLAIM
- FL/V3 WITH SSD HD
WARRANTY AND BE REFUNDED.

PROCESSING UNIT PIXIUM COMPATIBLE ONLY WITH RF_F3/4 DETECTOR CHECK JOBACRD D043 FOR
4C 5927403 49583C RF4343FL - FL WITH SSD DISK- REPLACEMENT PROCEDURE. FILL AND SEND THE REPORT FOR THE FAILED PART AS
SW REV3.1 EXPLAINED IN TB5464. WITHOUT IT GE CAN'T CLAIM WARRANTY AND BE REFUNDED.

TRIXELL DETECTOR PIXIUM


RF4343 AND RF4343FL CABLES
5 5466342-2 79374
KIT INCL. POWER CABLE AND
OPTICAL FIBER CABLE

NOT
5922398 84825 USB KEY WITH PU SW 4.3.1.2 FIXING GRAB IMAGE ISSUE ON PU RF.
SHOWN

NOT USB KEY WITH NEW PU 3.1 TO LOAD THE CORRECT SW VERSION ON C:\SW_SETUP AFTER INSTALLATION OF PN
5929827 84822
SHOWN SOFTWARE 5927403

Item # 1A - 5642243-2 Item # 1B - 5848552 Item # 2 - 5566092-2 Item # 2A - 5936157 Item # 3A - 5762963

Item # 3B - 5867604 Item # 4A - 5762964 Item # 4B - 5865067 Item # 5 - 5466342-2

32
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

2.2 Group 3 - AEC chambers

Item # GE Part # GMM Part # Description Additional Information

1 5466191-2 99806 SOLID STATE CHAMBER CLAYMOUNT MODEL 14062 WITH PRE-AMPLIFIER

2 5923564 56721 PREAMPLIFIER COMET AEC CHAMBER

3 5923565 41453 ION CHAMBER SOLO (3 ACTIVE SECTION)

4 5923566 99807 AEC CABLE (CHAMBER TO PREAMP)

Item # 1 - 5466191-2 Item # 2 - 5923564 Item # 3 - 5923565

33
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

2.3 DAP chambers

Item # GE Part # GMM Part # Description Additional Information

1 5780462 49552 DAP CHAMBER, VACUTEC TYPE 158 00 15 HR

Item # 1 - 5780462

34
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

2.4 Group 4 - General and detector power unit

Item # GE Part # GMM Part # Description Additional Information

1 5780463 56806 MAIN POWER SUPPLY FILTER

2 5780464 56785 DIGITAL SYSTEM ISOLATING TRANSFORMER

3 5780465 49543 DIGITAL SYSTEM POWER SUPPLY

4 5780466 52604 MAIN POWER SUPPLY FUSE

5 5780467 57412 MAIN CONTACTOR

6 5780468 57378 DETECTOR POWER SUPPLY FILTER

7 5780470 57373 DETECTOR SYSTEM ISOLATING TRANSFORMER

8 5780471 57371 DETECTOR SYSTEM POWER SUPPLY

9 5780472 1077403 DETECTOR POWER SUPPLY FUSE

Item # 1 - 5780463 Item # 2 - 5780464 Item # 3 - 5780465 Item # 4 - 5780466 Item # 5 - 5780467

35
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # 6 - 5780468 Item # 7 - 5780470 Item # 8 - 5780471 Item # 9 - 5780472

36
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

2.5 Group 5 - Image processor unite PID inside

GMM Part
Item # GE Part # Description Additional Information
#

PID RF43 WITH WINDOWS INSIDE VIDEO PROCESSOR WITHOUT HARDWARE KEY (ONLY HARDWARE). USABLE ONLY
1A 5780473 80163
SEVEN - SERIES 3 FROM PID S-N 5000. CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR REPLACEMENT

PID RF WITH WIN10 – THIS PID CAN BE USED FROM R7 SW RELEASE. THEY HAVE SN>12000. CHECK JOBCARD
1B 5883792 83170
SERIES 4 MANUAL FOR REPLACEMNT. NOT USABLE FROM R9 AND ON.

PID RF WIN10 – FOR FL4 THIS PID CAN BE USED ONLY WITH FL4 PANEL INTRODUCED FROM R9. CHECK JOBCARD
1C 5948988 R84850
DETECTOR MANUAL FOR REPLACMENT.

CPU PCIE-Q870-I2 - INTEL I7


2A 5867612 78347 USABLE ONLY FROM PID S-N 5000 TO PID SN 12000
- RAM: 8GB BOARD

CPU PCIE-Q370 – INTEL I9


2B 5883854 84867 USABLE FROM PID SN 12000
REV 11

CPU PCIE Q370 – INTEL I9 –


2C 5947921 84867A USABLE FROM PID SN 12000
REV 12

3A 5839148 80129 POWER SUPPLY PID USABLE ONLY FROM PID S-N 5000 TO PID SN 12000

POWER SUPPLY PID ATX500


3B 5883855 84864 USABLE FROM PID SN 12000
FSP500-80MPD

4A 5795334 78348 I/O PCI- HIC-02 BOARD REV2 USABLE ONLY FROM PID S-N 5000, REPLACED BY R84880

4B 5948989 R84880 I/O PCI- HIC-02 BOARD REV4 USABLE ONLY FROM PID S-N 5000, CHECK JOBCARD MANUAL FOR REPLACMENT

MATROX M9120 PCLE


5A 5839149 78350 USABLE ONLY FROM PID S-N 5000 TO PID SN 12000
GRAPHICS BOARD

GRAPHICS BOARD NVIDIA


5B 5883856 84858 USABLE FROM PID SN 12000
QUADRO P400

37
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

GMM Part
Item # GE Part # Description Additional Information
#

USABLE FROM PID SN 12000. FIND INSTALLATION DRIVER IN


GRAPHICS BOARD NVIDIA
5C 5936338 84878 https://gehealthcare.box.com/s/l2info57nvekaco0zasbge9qolwq4738 AND CHECK JOBCARD
QUADRO T400
MANUAL FOR INSTALLATION.

TELEDYNE DALSA FRAME


6 5839150 78349 USABLE ONLY FROM PID S-N 5000
GRABBER BOARD

HARD DISK ARCHIVE SSD


7B 5839144 78352 USABLE ONLY FROM PID S-N 5000, DO NOT USE ON SYSTEM WITH 512 GB C:\DISK INSTALLED
250GB (D:\)

HARD DISK ARCHIVE SSD


7C 5839145 78353 USABLE ONLY FROM PID S-N 5000, ARCHIVE ONLY (D:\)
500GB (D:\)

HARD DISK ARCHIVE SSD 1


7D 5839146 78354 USABLE ONLY FROM PID S-N 5000, ARCHIVE ONLY (D:\)
TB (D:\)

HARD DISK ARCHIVE SSD 2


7E 5839147 78355 USABLE ONLY FROM PID S-N 5000, ARCHIVE ONLY (D:\)
TB (D:\)

SSD DISK 512GB INNODISK USABLE FROM PID SN 12000, NEW C:\ DRIVE TO BE USED AS 256 GB OLD DISK, BACKWARD
7F 5948986 84887
3D TLC SATA 3. COMPATIBLE

REMIND TO CHANGE THE HARDWARE SN IN THE FIELD INTERFACE SECTION OF SERVICE


8A 5805294 65010 CAN BUS BOARD IXXAT
APPLICATION USABLE ON PID FROM SN 5000 TO 12000

USABLE FROM R7 SW RELEASE ONLY. TO BE ORDERED IF ITEM 65010 IS NO LONGER


8B 5883793 167672 CAN BUS BOARD SOFTING
AVAILABLE

9 5805625 78378 CPU BATTERY (WEAR PART) FIND IN DIGITAL SM THE BIOS CONFIGURATION IN CASE YOU LOSE IT

PID PASSIVE SHUTDOWN


10 5864694 57376
BOARD

DUAL LAN BRACKET EGPL-


11A 5883857 84859 USABLE FROM PID SN 12000
G201-C2

USABLE FROM PID SN 12000, IN ORDER TO INSTALL IT DOWNLOAD THE DRIVER AT LINK
DUAL LAN BRACKET EGLP-
11B 5936339 84874 https://gehealthcare.box.com/s/l2info57nvekaco0zasbge9qolwq4738 INSTALL THEM AND SAVE
G2S1-C2
IN C:\SW_SETUP

MINI DISPLAY PORT TO DVI


12 5883858 84865 USABLE FROM PID SN 12000
COVERTER

NOT
5864343 83099 HIC BOARD EPLD VER 89 YOU CAN USE THIS EPLD JUST IF R6 IS DEPLOYED ON THE SYSTEM
SHOWN

NOT USB TO LAN ADAPTER FOR


5864695 162884
SHOWN KALOS

NOT
5883203 83147 HIC BOARD PLD VER 90 YOU CAN USE THIS EPLD JUST IF R7 IS DEPLOYED ON THE SYSTEM
SHOWN

NOT
5883859 84860 HW RAM 8 GB
SHOWN

NOT
5914318 84861 HW RAM 16 GB
SHOWN

Item # 1A - 5780473 Item # 2A - 5867612 Item # 3A - 5839148 Item # 4A - 5795334 Item # 5A - 5839149

38
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # 5B - 5883856 Item # 6 - 5839150 Item # 9 - 5805625 Item # 12 - 5883858

39
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

2.6 Group 6 - Main controller module

Item # GE Part # GMM Part # Description Additional Information

REMIND TO FLASH THE BOARD ON SITE WITH ITS CURRENT SW. YOU CAN FIND IT
1 5780474 49546 M.C. CPU BOARD IN C:\SW_SETUP, CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR
REPLACEMENT

2 5780475 49547A M.C. I/O BOARD CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR REPLACEMENT

3 5780476 49548 M.C. AEC BOARD CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR REPLACEMENT

4 5780477 65008 M.C. ON/OFF BOARD

5 5780478 57417 ETHERNET SWITCH

6 5795335 R90534 FULL ASSEMBLED MAIN CONTROLLER

Item # 1 - 5780474 Item # 2 - 5780475 Item # 3 - 5780476 Item # 4 - 5780477 Item # 5 - 5780478

40
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

2.7 Group 9 - Monitor

Item # GE Part # GMM Part # Description Additional Information

1A 5780479 99839A MONITOR LCD 23" TS & LED COLOR DISPLAY – EIZO MS236WT REPLACED BY 5937087

CHECK JOBCARD D0060 FOR REPLACEMENT ON OLD


IB. REMIND THAT THIS MONITOR MUST BE EQUIPPED
MONITOR LCD 23” TS & LED COLOR DISPLAY- EIZO MS236WT-A
1B 5937087 84833 WITH: 2.0 USB CABLE TYPE AB FOR BLACK EXTENDER
With DVI to DP Converter
KVM ROSE BOX, 3.0 USB CABLE AB TYPE FOR SILVER
EXTENDER KVM ROSE BOX

2 5780480 57425A DVI-D EXTENDER WITH CABLES

CHECK THE DIGITAL SM IN ORDER TO CONFIGURE


3 5780481 57426A DVI-D SPLITTER & DVI-D EXTENDER WITH CABLES
CORRECTLY THIS DEVICE.

4 5420926 82378 TABLE TOP LCD SUPPORT

5 5827141 90525 WHEELS FOR DIGITAL CABINET

6 5838214 160919 DIN MONITOR 24” FHD PAX-324-C2B-HAR

7A 5853750 84806 IN ROOM MONITOR CABLE RUBBER COVER

7B 5923567 167806 CABLE SHEATH BLACK - PLASTIC SPIRAL IMPLEMENTED FROM SYS SN 01495

7C 5923568 162488 CABLE SHEATH GREY – EXTERNAL COVER IMPLEMENTED FROM SYS SN 01495

BLACK ETHERNET CABLES BETWEEN TRASMITTER AND RECEIVER


8 5867860 57499
(ALL)

USED ALSO FOR IN-ROOM MONITOR, IMPLEMENTED


9A 5923058 57512 DISPLAY PORT CABLE 20 MT
FROM SYS SN 01495

9B 5923057 57427 POWER SUPPLY MONITOR CABLE 20 MT USED ALSO FOR IN-ROOM MONITOR

9C 5923056 56114 GROUND CABLE 20MT USED ALSO FOR IN-ROOM MONITOR

9D 5923059 57365 AUDIO CABLE 20MT USED ONLY FOR IN ROOM MONITOR

41
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # GE Part # GMM Part # Description Additional Information

10 5923569 57515 DP SPLITTER FOR IN-ROOM AND CONTROL ROOM MONITOR

NOT SHOWN 5883861 57436 USB USER INTERFACE DEVICE PASSIVE DIRECT EXTENDER IMPLEMENTED FROM SYS SN 01495

NOT SHOWN 5883204 30715 GMM REF FOR USB CABLE FROM PID TO KVM , 1,2 M

USED ALSO FOR IN-ROOM MONITOR, IMPLEMENTED


NOT SHOWN 5931751 57514 MINI DP TO DP CONVERTER
FROM SYS SN 01495

Item # 1A - 5780479 Item # 1B - 5937087 Item # 2 - 5780480 Item # 3 - 5780481 Item # 4 - 5420926

Item # 10 - 5923569

42
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

2.8 group 8, 11, 13 - Cabinet and console devices

Item # GE Part # GMM Part # Description Additional Information

1A 5780482 55744A USB ALPHANUMERIC KEYBOARD - ITALIAN

1B 5780483 57217A USB ALPHANUMERIC KEYBOARD - ENGLISH

1C 5780484 57216A USB ALPHANUMERIC KEYBOARD - FRENCH

1D 5780485 57422A USB ALPHANUMERIC KEYBOARD - DUTCH

1E 5780486 57420A USB ALPHANUMERIC KEYBOARD - GERMAN

1F 5780487 57215A USB ALPHANUMERIC KEYBOARD - SPANISH

1G 5780488 57423A USB ALPHANUMERIC KEYBOARD - NORWEGIAN

1H 5780489 57421A USB ALPHANUMERIC KEYBOARD - RUSSIAN

1I 5806964 57453A USB ALPHANUMERIC KEYBOARD - PORTUGUESE

1J 5806965 57454A USB ALPHANUMERIC KEYBOARD - SWEDISH

1K 5883794 90616A USB ALPHANUMERIC KEYBOARD - BRAZILIAN PORTUGUESE

1L 5883795 90612A USB ALPHANUMERIC KEYBOARD - DANISH

1M 5883796 90614A USB ALPHANUMERIC KEYBOARD - FINNISH

1N 5883797 90605A USB ALPHANUMERIC KEYBOARD - HUNGARIAN

2 5780491 57424 USB MOUSE

3 5780492 94707 SWITCH ON DIGITAL SYSTEM

4 5780493 78387 ADDITIONAL EXTERNAL DVD WRITER

NOT USABLE FOR US INSTALLATION. THE INPUT VOLTAGE FOR


5 5484239-2 97082 UPS OP2003 +CABLES
THIS DEVICE IS BETWEEN 210-240 V

43
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # GE Part # GMM Part # Description Additional Information

THE INFORMATION PROVIDED UNDER THE PRESENT


EATON 9SX 1KVA UPS LONG LIFE BATTERY WITHOUT SNMP PARAGRAPH, AS WELL AS THE INSTALLATION, USE,
6 5869178
CARD MAINTENANCE AND DISPOSAL OF THIS DEVICE ARE UNDER
THE EXCLUSIVELY RESPONSIBILITY OF GE HEALTHCARE.

THE INFORMATION PROVIDED UNDER THE PRESENT


PARAGRAPH, AS WELL AS THE INSTALLATION, USE,
7 5871536 UPS HW CABLE KIT FOR XRAY DISCOVERY RF180
MAINTENANCE AND DISPOSAL OF THIS DEVICE ARE UNDER
THE EXCLUSIVELY RESPONSIBILITY OF GE HEALTHCARE.

THE INFORMATION PROVIDED UNDER THE PRESENT


PARAGRAPH, AS WELL AS THE INSTALLATION, USE,
8 5805630 COLLECTOR KIT FOR UPS FOR XRAY DISCOVERY RF180 - 2KVA
MAINTENANCE AND DISPOSAL OF THIS DEVICE ARE UNDER
THE EXCLUSIVELY RESPONSIBILITY OF GE HEALTHCARE.

THE INFORMATION PROVIDED UNDER THE PRESENT


PARAGRAPH, AS WELL AS THE INSTALLATION, USE,
9 5805636 UPS HW CABLE KIT FOR XRAY DISCOVERY RF180 - 2KVA
MAINTENANCE AND DISPOSAL OF THIS DEVICE ARE UNDER
THE EXCLUSIVELY RESPONSIBILITY OF GE HEALTHCARE.

Item # 1A - 5780482 Item # 2 - 5780491 Item # 3 - 5780492 Item # 4 - 5780493 Item # 5 - 5484239-2

44
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

2.9 Group 21 - PIXIUM WIFI detector unit

Item # GE Part # GMM Part # Description Additional Information

FILL AND SEND THE REPORT FOR THE FAILED PART AS EXPLAINED IN
1A 5762966 79388 PIXIUM 3543 WI-FI EZ-G (GADOX)
TB5464. WITHOUT IT GE CAN'T CLAIM WARRANTY AND BE REFUNDED.

FILL AND SEND THE REPORT FOR THE FAILED PART AS EXPLAINED IN
1B 5762968 79384A PIXIUM 3543 WI-FI EZ-C (CESIUM)
TB5464. WITHOUT IT GE CAN'T CLAIM WARRANTY AND BE REFUNDED.

FILL AND SEND THE REPORT FOR THE FAILED PART AS EXPLAINED IN
1C 5762969 79389A PIXIUM 2430 WI-FI EZ (CESIUM)
TB5464. WITHOUT IT GE CAN'T CLAIM WARRANTY AND BE REFUNDED.

PIXIUM 3543EZ WI-FI DETECTOR BATTERY (ONE (OLD MODEL) TO BE ORDERED TILL OUT OF STOCK. REPLACED BY
2A 5762970 99742
PIECE) 5866911 FULL BACKWARD COMPATIBLE.

PIXIUM 3543EZ WI-FI DETECTOR BATTERY (ONE


2B 5866911 99742A
PIECE)

3 5762971 99741 PIXIUM 3543EZ WI-FI BATTERY RECHARGER

PIXIUM EZ WI-FI DETECTOR CABLE (FOR CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR UPGRADE
4 5762972 79383
CONFIGURATION) PROCEDURE

5 5805838 79390 ON/OFF BUTTON FOR EZ PANELS

MUST BE CONFIGURED ON SITE. CHECK JOBCARD MANUAL (PN


6A 5830387 160735 D-LINK MODEM FOR WIFI DETECTOR TYPE 2660
5793733-1EN) FOR UPGRADE PROCEDURE

MUST BE CONFIGURED ON SITE. CHECK JOBCARD MANUAL (PN


6B 5923570 R167648 D-LINK MODEM FOR WIFI DETECTOR TYPE 2610 5793733-1EN) FOR UPGRADE PROCEDURE, CONFIGURATION FILE ON
BOARD AVAILABLE FROM R7.3

NOT INFRARED SENSOR FOR DETECTOR


5838215 82360 CHEK JOBCARD MANUAL FOR INSTALLATION PROCEDURE
SHOWN CONFIGURATION

45
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

3. Generator − X-ray tube

01_LEFT_SIDE 02_RIGHT_SIDE 03_LEFT_SIDE_WITHOUT_CARTER 04_BEHIND_SIDE_WITHOUT_CART Thumbs

Item # GE Part # GMM Part # Description Additional Information

1 5778057 79194 I/P DISTRIBUTION BOARD FOR 65-80 KW

2A 5864762 79195A MEZZANINE BOARD FOR 65-80 KW FUSE INCLUDED (NEW ITEM PICTURE)

2B 5778136 79195 MEZZANINE BOARD FOR 65 80KW REPLACED BY 79195A AFTER GENERATOR SN AMQ02500J20

3A 5866540 79196A GENERATOR RECTIFIER BOARD FULL BACKWARD COMPATIBLE

3B 5778137 79196 GENERATOR RECTIFIER BOARD REPLACED BY 79196A

46
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # GE Part # GMM Part # Description Additional Information

CONFIGURATION MUST BE LOADED FROM PREVIOUS BACKUP AFTER A


FACTORY DEFAULT. ASK TO YOUR OLC TO PROVIDE NEW LICENCE
4 5778138 79197 GENERATOR CPU BOARD
READING THE SN ON THE BOARD (SMALL LABELS ON IT) AND THE SN OF
THE GENERATOR

REFER TO THE JOB CARD MANUAL FOR REPLACEMENT AND SETUP OF


5 5778139 R79198 GENERATOR CONTROL BOARD
THIS PART

6 5778140 79199 CONSOLE CONNECTOR BOARD

7 5778141 79200 AUXILIARY CPU BOARD

8 5778142 79201 ROOM I/O BOARD

9 5778144 79202 TEMPERATURE SENSOR BOARD

TO BE IMPLEMENTED FROM SN - AMQ00932J18 FOR INDICO AS STATED


10 5817469 79233 FILAMENT SUPPLY UNIVERSAL LF-SF ON THE SCR-0080756. REFER TO THE JOB CARD MANUAL FOR
REPLACEMENT AND SETUP OF THIS PART

12 5778148 79203 FAN ASSEMBLY - AXIAL - LARGE

13 5778157 79204 FAN ASSEMBLY - AXIAL - SMALL

14 5778158 79205 TRANSFORMER ROOM POWER

THIS FRU CONTAIN ONLY A SINGLE BOARD. FOR 80KW GENERATOR YOU
15A 5778159 79206 INVERTER BOARD FOR 80 KW
MUST REPLACE ALL THE 3 BOARDS TOGETHER

THIS FRU CONTAIN ONLY A SINGLE BOARD. FOR 65KW GENERATOR YOU
15B 5778160 79207 INVERTER BOARD FOR 65 KW
MUST REPLACE THE 2 BOARDS TOGETHER

16A 5778162 79209 RESONANT ASSEMBLY FOR 65 KW

USABLE ON GENERATOR TILL SN XXXXXXXXA18. ORDER PART 79210A


16B 5778163 79210 RESONANT ASSEMBLY FOR 80 KW FOR NEWER GENERATOR. THE GENERATOR SN INDICATE THE AGE OF IT. -
-------A18 MEAN PRODUCED IN JANUARY 2018.

16C 5865066 79210A RESONANT ASSEMBLY FOR 80 KW USABLE ON GENERATOR AFTER SN XXXXXXXXA18.

17A 5778164 79213 HV TANK - 65 kW 2 TUBES

17B 5778165 79214 HV TANK - 80 kW 2 TUBES

17C 5778167 79217 HV TANK - 65 kW - 1 TUBE

17D 5778168 79218 HV TANK - 80 kW - 1 TUBE

NOT COMPATIBLE ON GENERATOR FROM SN AMQ04458L22 TO SN


18 5778170 79224 DUAL SPEED STARTER BOARD AMQ5104F23. USE INSTEAD DSS AND CAPACITOR PANEL FULL ASSEMBLY
PN 5948987.

19 5220037 56556 TDI 1 BOARD - INTERFACE BOARD

21 5778173 79066 FUSE FNQ2 TYPE

22 5778174 34984 FUSE GDC1.6 TYPE

CAN’T BE USED ON NEW BOARD 5864762. USABLE WITH OLDER


23A 5756827-2 79074 MAIN LINE FUSE, 60 AMPS
MEZZANINE BOARD 5778136

23B 5864763 79244 MAIN LINE FUSES, 80A (KIT OF 3 FUSES) USABLE FROM CPI IQ SN AMQ02500J20

24 5778177 79097 FUSE A70QS10-14F TYPE

25 5800062 166148 IQ GENERATOR INTERFACE BOARD

CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR REPLACEMENT. FILL


X-RAY TUBE G292 (INSERT)+ B130 (HOUSING)
26A 5642608-2 41242 AND SEND THE REPORT FOR THE FAILED PART AS EXPLAINED IN TB5464.
WITHOUT SUPPORT
WITHOUT IT GE CAN'T CLAIM WARRANTY AND BE REFUNDED.

X-RAY TUBE SG1096 (INSERT)+ B190 (HOUSING)


26B 5795337 96791
WITHOUT SUPPORT

X-RAY TUBE RTM101 (INSERT)+ C52S (HOUSING) FILL AND SEND THE REPORT FOR THE FAILED PART AS EXPLAINED IN
26C 5779653 95770
WITHOUT SUPPORT TB5464. WITHOUT IT GE CAN'T CLAIM WARRANTY AND BE REFUNDED.

NOT COMPATIBLE ON GENERATOR FROM SN AMQ04458L22 TO SN


27 5853025 79241 DSS CAPACITOR PANEL AMQ5104F23. USE INSTEAD DSS AND CAPACITOR PANEL FULL ASSEMBLY
PN 5948987.

47
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # GE Part # GMM Part # Description Additional Information

DSS FULL ASSEMBLY FOR CPI TEMPORARY TO BE USE FOR GENERATORS WITH SN IN BETWEEN SN AMQ04458L22
28 5948987 79254
SHORTAGE - TAB 76 AND SN AMQ5104F23.

Item # 1 - 5778057 Item # 2A - 5864762 Item # 2B - 5778136 Item # 3A - 5866540 Item # 3B - 5778137

Item # 4 - 5778138 Item # 5 - 5778139 Item # 6 - 5778140 Item # 7 - 5778141 Item # 8 - 5778142

Item # 9 - 5778144 Item # 10 - 5817469 Item # 12 - 5778148 Item # 13 - 5778157 Item # 14 - 5778158

Item # 15A - 5778159 Item # 15B - 5778160 Item # 16A - 5778162 Item # 16B - 5778163 Item # 16C - 5865066

48
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Item # 17A - 5778164 Item # 17B - 5778165 Item # 17C - 5778167 Item # 17D - 5778168 Item # 18 - 5778170

Item # 19 - 5220037 Item # 21 - 5778173 Item # 22 - 5778174 Item # 23A - 5756827-2 Item # 23B - 5864763

Item # 24 - 5778177 Item # 25 - 5800062 Item # 26A - 5642608-2 Item # 27 - 5853025

49
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

4. OTS kalos type

Item # GE Part # GMM Part # Description Additional Information

4.1. CONTROLS PANEL

4.2. SUSPENSION ARM

4.3. TELESCOPE

4.4. RAILS

N.B. CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR UPGRADE PROCEDURE

50
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

4.1 Controls panel

Item # GE Part # GMM Part # Description Additional Information

1 5781394 122735 CAPACITIVE 3-SENSOR BOARD

2 5781395 122736 CAPACITIVE 2-SENSOR BOARD

3 5781396 122586A TFT LCD 10.4” 800x600 G104STN01.0

4 5493982-2 96956 TOUCH SCREEN ELO E458225

5 5781397 82038 TOUCH SCREEN BOARD BRING A SW VERSION PRELOADED

6 5781398 122728 KALOS CAN I/F INTERFACE BOARD BRING A SW VERSION PRELOADED

7 5493511-2 96947 EMERGENCY BUTTON

8 5493504-2 96949 EMERGENCY BUTTON CONTACT ASSEMBLY

9 5493536-2 122479 TOUCH SCREEN CPU ASSEMBLY BRING A SW VERSION PRELOADED

10 5827132 122192A RALCO COLLIMATOR MANUAL KALOS OTS

THIS PART INCLUDE ALSO ITEM 1 AND 2. PLEASE ORDER ALSO PART
11 5934542 R160878 ASSEMBLED OTS FRONT HANDLE
5934541 (GMM 160455) IN ORDER TO STICK A NEW GE LOGO LABEL.

NOT SHOWN 5934541 160455 GE LOGO ON FRONT HANDLE

51
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

4.2 Suspension arm

Item # GE Part # GMM Part # Description Additional Information

1 5781453 166053 KIT STRINGAUGE NEEDED NEW CALIBRATION AS FOR KALOS OTS SM

2 5781454 122727 KALOS TBS INTERFACE

3 5781455 121090B PROXIMITY SENSOR (ANTI-COLLISION)

TO BE USED IN CASE OF ANY COVER REPLACEMENT ON KALOS OTS IF SN


4 5867156 162922 REPLACEMENT KIT FOR KALOS ARM COVER LOWER THEN 37506. IF THE NEW SET IS ALREDY DEPLOYED YOU CAN USE
SINGLE COVER PN HERE BELOW.

5 5864690 162901 KALOS OTS FRONT ARM COVER

6 5864689 160839 KALOS OTS RIGHT ARM COVER

7 5864688 160838 KALOS OTS LEFT ARM COVER

8 5864687 160837 KALOS OTS PLASTIC JOIN COVER ONTUBE ARM

52
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

4.3 Telescope

Item # GE Part # GMM Part # Description Additional Information

THIS BOARD BRING A SW. YOU NEED TO CHECK THE SW VERSION


AND RESTORE THE PREVIOUS CONFIGURATION BACKUP. IF THE SW
1 5781456 122730 KALOX ARM CPU BOARD
LOADED IS NOT CORRECT YOU CAN LOAD THE CORRECT ONE
PRESENT IN C:\SW_SETUP

2 5780309 122725 KALOS MAIN CPU

3A 5780310 122620 TELESCOPES BRUSHLESS MOTOR DRIVE

DRIVER AKD FOR KALOS VERTICAL MOVMENT (NCCC IF 5883798 NCCC TYPE IS NOT AVAILABLE, ORDER NBCC TYPE
3B 5883798 84813
MODEL) 5780310, DO NOT MODIFY THE SW VERSION OF THIS ITEM.

4 5369098-2 96207 MICROSWITCH TYPE AM1108-11

5 5781459 122582 24V dc MAGNETIC BRAKE

6 5788608 160574 KALOX BELTS REPLACEMENT KIT

7 5864819 121839 BACK OTS CARRIAGE COVER

8 5864818 121838 FRONT OTS CARRIAGE COVER

53
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

4.4 Rails

Item # GE Part # GMM Part # Description Additional Information

NEW POSITION CALIBRATION NEEDED AS FOR KALOS OTS SM, CHECK ALSO
1 5781461 121887A MAGNET SIKO MSA 510-1-0001 REPLACEMENT PROCEDURE ON KALOS OTS SM. USE KALOS SERVICE
PROGRAM VER 6.3 OR HIGHER

NEW POSITION CALIBRATION NEEDED AS FOR KALOS OTS SM, CHECK ALSO
2 5781462 121888A MAGNETIC BAND DETECTOR MT. 3 REPLACEMENT PROCEDURE ON KALOS OTS SM. USE KALOS SERVICE
PROGRAM VER 6.3 OR HIGHER

NEW POSITION CALIBRATION NEEDED AS FOR KALOS OTS SM, CHECK ALSO
3 5781463 121889A MAGNETIC BAND DETECTOR MT. 4,4 REPLACEMENT PROCEDURE ON KALOS OTS SM. USE KALOS SERVICE
PROGRAM VER 6.3 OR HIGHER

NEW POSITION CALIBRATION NEEDED AS FOR KALOS OTS SM, CHECK ALSO
4 5781464 121921 MAGNETIC BAND DETECTOR MT. 3,6
REPLACEMENT PROCEDURE ON KALOS OTS SM.

5 5781459 122582 24V dc MAGNETIC BRAKE

6 5369098-2 96207 MICROSWITCH TYPE AM1108-11

7 5838875 40833A UNISTRUT KIT FOR LOGITUDINAL RAILS

NOT FOLLOW INSTRUCTION ON KALOS SM AND WITH THE KIT ITSELF. THIS KIT CAN
5864684 162900A KALOS SMALL ELEVATOR/ROOM KIT
SHOWN BE USED FOR LET KALOS OTS IN ROOM WITH LIMITED ACCESS

54
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

5.1 Portegra 2 / ceiling column 360°

Item # GE Part # GMM Part # Description Additional Information

1 E-7110980 NA POST PLASTIC COVER ASSEMBLY

2 E-7110905 NA BEARING SNAP RING ASSEMBLY WITH PAIR OF PLIER

3 E-7110914 NA POST FALL ARRESTER ASSEMBLY

4 E-7110637 NA POST AND ARM PLASTIC COVER ASSEMBLY

5 E-6080179 NA SAFETY SNAP HOOK AND CEILING ANCHOR

6 E-TS20918 NA PLASTIC LOWER COVER MOUNTING POST

7 E-TS20B05 NA INSULATING KIT

8 E-7110918 NA PLASTIC UPPER COVER MOUNTING POST

9 E-7110208 NA CANOPY FOR PORTEGRA 2 STATIONARY COLUMNS

55
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

5.2 Portegra 2 / extension spring - spring arm not electrical

Item # GE Part # GMM Part # Description Additional Information

1 E-7110636 NA ARM PLASTIC COVER ASSEMBLY

2 E-0T25B10 NA COUPLING ASSEMBLY

3 E-7110219 NA COUPLING CLIP AND SAFETY SPRING

4 E-6080192 NA SAFETY COLLAR AND COUPLING ASSEMBLY

5 E-7110922 NA PAIR OF PLIERS FOR SNAP RING

6 E-7110692 NA SET PLASTIC BACK COVER FOR SPRING ARM

7 E-7110698 NA SET FRONT COVER SPRING ARM

8 E-7110690 NA WHOLE COVER SET LONG AND CAP

9 E-GD40B006 NA RINSTRAP FOR CABLES X2

56
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

6. Wallstand

Item # GE Part # GMM Part # Description Additional Information

6.1. STAND GROUP

6.2. BUCKY GROUP

6.3. TILTING STAND GROUP WTS

6.4. OPTIONALS

N.B. CHECK JOBCARD MANUAL (PN 5793733-1EN) FOR UPGRADE PROCEDURE

57
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

6.1 Stand group

Item # GE Part # GMM Part # Description Additional Information

1 5119059 03715 BEARING

2 5119058 39735 IDLE PIN

3 5119056 R46887 BEARING FIXED PIN

4 5119057 R46886 ECCENTRIC PIN

VERIFY THAT BRAKE ASSEMBLY IS CENTERED ON


5 5119023 R46655 POTTER BRAKE ASSEMBLY
THE RAIL WHEN TIGHTENING SCREWS.

6 5119024 46839 CABLE SUPPORT ASSEMBLY

7 5119071 46479 LEFT COVER

8 5119072 46480 RIGHT COVER

9 5119069 46826A LOWER COLUMN COVER

10 5794771 46742 UPPER COLUMN COVER

11 5119073 46979A COLUMN TOP COVER

NEW CALIBRATIOIN FOR OTS TRANCKING


NOT SHOWN 5838808 166018 WALL STAND UP/DOWN YOYO POTENCIOMETER FOR OTS SYNCHRO
NEEDED AS FOR KALOS OTS SM

58
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

6.2 Bucky group

Item # GE Part # GMM Part # Description Additional Information

1 5119068 R46658B CASSETTE RELEASE GROUP – TILTING

2 5171929 46585B FRONT PANEL W/ CHIN SUPPORT SECTION

3 5466273-2 46587 POTTER BUCKY COMPLETE

4 5466272-2 30631 CASSETTE TRAY WITH SIZING

5 5466224-2 04909A SOLID STATE CHAMBER (WALLSTAND) NEEDED NEW CALIBRATION OF AEC SECOND CHAMBER AS FOR DIGITAL SM

6 5883788 73103 WALL BUCKY GRID

59
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

6.3 Tilting stand group WTS

Item # GE Part # GMM Part # Description Additional Information

1 5119060 R46665 POTTER ORIENTATION LEVER – TILTING

2 5119063 46447 POTTER ROTATION DISK – TILTING

3 5119061 4647400 GAS SPRING – TILTING

4 5119062 46446 POTTER ROTATION PIVOT – TILTING

5 5119059 03715 BEARING

6 5119064 46534 RELEASE LEVER SUPPORT - TILTING

7 5119066 46453 RELEASE PIN – TILTING

8 5119067 46454 POTTER ROTATION RELEASE LEVER – TILTING

9 5119065 1400746 SPRING – TILTING

10 5119074 46552 POTTER ROTATION RIGHT COVER – TILTING

11 5119075 46553 POTTER ROTATION LEFT COVER - TILTING

12 5145875 46536 POTTER ROTATION BEARING

60
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

6.4 Optionals

Item # GE Part # GMM Part # Description Additional Information

6.4.1. 5119028 46892A ARM REST - NON TILTING

6.4.2. 5119033 46670A ARM REST - TILTING

61
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

6.4.1 Arm rest WS

Item # GE Part # GMM Part # Description Additional Information

1 5119032 46809 ARM REST FIXATION – NON TILTING

2 5119030 46815 ARM REST SUPPORT – NON TILTING

3 5119029 46799 POSITIONING HANDLE

62
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

6.4.2 Arm rest WST

Item # GE Part # GMM Part # Description Additional Information

1 5119029 46799 POSITIONING HANDLE

2 5119037 46488 ARM REST FIXATION - TILTING

3 5119052 46500 SUPPORT FOR FIXATION OF ARM REST - TILTING

4 5119036 46504A ARM REST SUPPORT - TILTING

63
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

Index
0. Layout 5

- 0. Layout 5

1. Table 6

- 1. Table 6

- 1.01 Elevation tilting group 7

- 1.02 SID group 10

- 1.03 X-ray tube group 12

- 1.04 Main beam group 14

- 1.05 SFD group 16

- 1.06 Tabletop group 18

- 1.07 Compressor group 20

- 1.08 Console group 21

- 1.09 Accessory 23

- 1.10 GE Intercom device 25

- 1.11 Cables 26

- 1.12 Kit service 28

2. Digital system 29

- 2. Digital system 29

- 2.1 Group 1a/1b - PIXIUM RF4343 Detector Unit 31

- 2.2 Group 3 - AEC chambers 33

- 2.3 DAP chambers 34

- 2.4 Group 4 - General and detector power unit 35

- 2.5 Group 5 - Image processor unite PID inside 37

- 2.6 Group 6 - Main controller module 40

- 2.7 Group 9 - Monitor 41

- 2.8 group 8, 11, 13 - Cabinet and console devices 43

- 2.9 Group 21 - PIXIUM WIFI detector unit 45

3. Generator - X-ray tube 46

- 3. Generator − X-ray tube 46

4. OTS kalos type 50

- 4. OTS kalos type 50

- 4.1 Controls panel 51

- 4.2 Suspension arm 52

64
GE Healthcare Discovery RF180
5793734-1EN, Revision 7 Renewal Parts Manual

- 4.3 Telescope 53

- 4.4 Rails 54

5. Mavig Suspension 55

- 5.1 Portegra 2 / ceiling column 360° 55

- 5.2 Portegra 2 / extension spring - spring arm not electrical 56

6. Wallstand 57

- 6. Wallstand 57

- 6.1 Stand group 58

- 6.2 Bucky group 59

- 6.3 Tilting stand group WTS 60

- 6.4 Optionals 61

- 6.4.1 Arm rest WS 62

- 6.4.2 Arm rest WST 63

This document applies to any replacement linked to product Discovery RF180, its subassembly and accessories. All replacements
parts must be performed in accordance to this document.

65