Rating details of Fan/Blowers millwide Fan/Blower Details

Sr.No. Area Application KW RPM VFD/DOL Voltage Flow Head


1 KPM-5 PV fan No.1 55 1475 VFD 415
2 KPM-5 PV fan No.2 132 1475 VFD 415
3 KPM-5 PV fan No.3 90 1475 VFD 415
4 KPM-5 PV fan No.4 110 985 VFD 415
5 KPM-5 PV fan No.5 75 1475 VFD 415
6 KPM-5 Exhaust fan no.1 75 1475 VFD 415
7 KPM-5 Exhaust fan no.2 45 1475 VFD 415
8 KPM-5 Exhaust fan no.3 75 1475 VFD 415
9 KPM-5 Vacuum shoe exhaust air fan 110 2980 VFD 415
10 KPM-5 vacuum balance exhaust air fan 110 2980 VFD 415
11 KPM-5 Vacuum fabric cleaner air fan 45 2980 VFD 415
12 KPM-5 Press Nip fan 18.5 2950 DOL 415
13 KPM-5 Press run fan 30 2950 DOL 415
14 KPM-5 Rewinder-1 trim blower 45 2950 DOL 415
15 KPM-5 Rewinder-2 trim blower 18.5 2950 DOL 415
16 KPM-5 Cooling tower fan 22 1475 DOL 415
17 UT-1 UT-1ID-1 75 980 DOL 415
18 UT-1 UT-1ID-2 75 980 VFD 415
19 UT-1 UT-1 FD -1 200 1465 DOL 415
20 UT-1 UT-1 FD -2 200 1465 DOL 415
21 UT-1 UT-1 FD -3 200 1465 DOL 415
22 UT-1 UT-1-1PA-1 75 2900 DOL 415
23 UT-1 UT-1-1PA-2 75 2900 DOL 415
24 UT-1 UT-1 Dust Collector Blower 18.5 1455 DOL 415
25 UT-1 Pressurization Blower 11 1440 DOL 415
26 UT-2 UT-2 FD -1 500 1480 DOL 3300
27 UT-2 UT-2 FD -2 500 1480 DOL 3300
28 UT-2 UT-2 PA-1 75 1485 DOL 415
29 UT-2 UT-2 PA-2 75 1485 DOL 415
30 UT-2 UT-2 ID-1 200 980 DOL 415
31 UT-2 UT-2 ID-2 200 980 DOL 415
32 UT-2 UT-2 Dust Collector Blower 15 1460 DOL 415

33 DIP Dust colector blower at drum pulper 5.5 1460 DOL 415
34 KPM # 1 Mould Blower no.1 55 1440 DOL 415 40000 m3/hr 300 MM WG
35 KPM # 1 Mould Blower no.2 55 1440 VFD 415 40000 m3/hr 300 MM WG
36 KPM # 1 Section blower no.1 22 2900 DOL 415 3200 m3/hr 1150 mm WG
37 KPM # 1 Section blower no.2 22 2900 DOL 415 3200 m3/hr 1150 mm WG
38 KPM # 1 Coating blower new no.1 55 1440 VFD 415 35000 m3/h 3000 Pa
39 KPM # 1 Coating blower new no.2 45 1440 VFD 415 27272 m3/ hr 3200 Pa
40 KPM # 1 Coating Blower No. 1 75 1500 DOL 415 42000 m3/hr 350 mm of WG
41 KPM # 1 Coating Blower No 2 75 1500 DOL 415 42000 m3/hr 350 mm of WG
42 KPM # 1 Coating Blower No 3 75 1500 DOL 415 42000 m3/hr 350 mm of WG
43 KPM # 1 Exhaust Blower for coaters 11 1,500 DOL 415 10,000 m3/hr 350 mm of WG
44 KPM # 1 Coating Exhaust Blower 5.5 1440 DOL 415 4252 m3/hr 2058 Pa
45 KPM # 1 Blower of cooling tower motor 2.2 1440 DOL 415
46 KPM # 1 Blower of cooling tower motor 2.2 1440 DOL 415
47 KPM # 1 Trim blower for Milltex cutter 37 2940 DOL 415 1400 kg/hr
48 KPM # 1 Trim blower for Rewinder 22 1440 DOL 415 1200 kg/hr
49 KPM # 1 Trim blower for New Milltex cutter 18.5 2940 DOL 415
50 KPM # 2 Mould Blower No.1 18.5 2900 DOL 415 30000 m3/hr 300 MM WG
51 KPM # 2 Mould Blower No.3 18.5 2900 VFD 415 30000 m3/hr 300 MM WG
52 KPM # 2 Blower at MG 3.7 1440 VFD 415
53 KPM # 2 Trim blower JG 30 cutter 37 2900 DOL 415 1200 kg/hr
54 KPM # 2 Suction Blower No. 2 30 1,440 DOL 415 2300 m3/hr 900 mm WG
55 KPM # 2 Suction Blower No. 4 30 1,440 DOL 415 2300 m3/hr 900 mm WG
56 KPM # 2 New Coating blower no.1 ( drive) 45 1,440 VFD 415 27272 m3/hr 3200 Pa
57 KPM # 2 New Coating blower no.2 (drive) 30 1,440 VFD 415 27272 m3/hr 3200 Pa
58 KPM # 2 Coating blower No.1 45 1440 DOL 415 27272 m3/hr 3200 Pa
59 KPM # 2 Coating blower No.2 45 1440 DOL 415 27272 m3/hr 3200 Pa
60 KPM # 2 Coating blower No.3 45 1440 DOL 415 27272 m3/hr 3200 Pa
61 KPM # 2 Coating Exhaust Blower no.1 5.5 1400 DOL 415 4252 m3/hr 2060 pa
62 KPM # 2 Coating Exhaust Blower no.2 5.5 1400 DOL 415 4252 m3/hr 2060 pa
63 KPM # 2 Coating Exhaust Blower no.3 5.5 1,440 DOL 415 4252 m3/hr 2060 pa
64 KPM # 4 Pv Fan no-1 55 1440 VFD 415
65 KPM # 4 Pv Fan no-2 75 1440 VFD 415
66 KPM # 4 Pv Fan no-3A 132 1440 VFD 415
67 KPM # 4 Pv Fan no-3B 132 1440 VFD 415
68 KPM # 4 Pv Fan no-4 90 1440 VFD 415
69 KPM # 4 Exhaust fan no-1 37 1440 VFD 415
70 KPM # 4 Exhaust fan no-2 37 1440 VFD 415
71 KPM # 4 Exhaust fan no-3A 30 1440 VFD 415
72 KPM # 4 Exhaust fan no-3B 30 1440 VFD 415
73 KPM # 4 Exhaust fan no-4 45 1440 VFD 415
74 KPM # 4 Trim Blower Rewinder-1 22 1440 DOL 415
75 KPM # 4 Trim Blower Rewinder-2 22 1440 DOL 415
76 KPM # 4 Trim Blower Miltex Cutter-1 22 1465 DOL 415
77 KPM # 4 Trim Blower Miltex Cutter-2 37 1470 DOL 415
78 KPM # 4 Trim Blower Pizzaloto Cutter 18.5 2900 DOL 415
79 KPM # 4 Trim Blower A-4 Cutter 30 1470 DOL 415
80 KPM # 4 Qcs Blower 3.7 1440 DOL 415
81 KPM # 4 Calcoil Blower(Near Calendar) 3.7 2900 DOL 415
82 KPM # 4 Pope Reel Blower(Hood room) 9.3 1440 DOL 415
83 KPM # 4 Flat Boxes Blower 5.5 2900 DOL 415
84 KPM # 4 Third Press Blower 37 1475 DOL 415
85 KPM # 4 False ceiling Hot Blower 3.7 1440 DOL 415
86 KPM # 4 Transfer Foil Blower 15 1455 DOL 415
87 KPM # 4 Vacc Blower -2 top former 15 2900 DOL 415
88 KPM # 4 Vacc Blower -1 top former 30 1475 DOL 415
89 KPM # 4 Mist Free Blower 37 1440 DOL 415
90 KPM # 4 Qcs Blower(near size press) 7.5 2900 DOL 415
91 KPM # 4 Speed SizerFalse ceiling Supply fan 2.2 1475 DOL 415
92 KPM # 4 Air turn Fan 22 1476 VFD 415
93 KPM # 4 Cooling Tower fan 22 1475 VFD 415
KW Qty 15KW onwards
DOL KW 3569 62 46
VFD KW 1956 31 30
TOTAL 5525 93 76
Fan/Blower Details
Efficiency Type Make Remarks

VFD trial taken app 5 kw saving


(1Drive+1DOL)

VFD trial taken app 2 kw saving

Energy conservation fan installed.


VFD trial taken app 20 kw saving
(1Drive+1DOL)
VFD trial taken app 20 kw saving
(1Drive+1DOL)

20-710 Vacunair 56 86
20-710 Vacunair
SP-300/45 Vacunair
SP-300/45 Vacunair
Y8-18-1000C SLMC to be installed
Y5-47 900 C SLMC to be installed
18-710 DNB
18-710 DNB
18-710 DNB
18-400 DNB
Y-47 500 C SLMC to be installed

22-355-26 Vacunair
22-300 Vacunair
Miltex
Vacunair
Vacunair

22-300 Vacunair
Vacunair
Vacunair
Y5-47-900 C SLMC
Y5-47-900 C SLMC
Y5-47-900 C SLMC
Y5-47-900 C SLMC
Y5-47-900 C SLMC
Y5-48-400 C SLMC
Y5-48-400 C SLMC
Y5-48-400 C SLMC

All Running on vfd during Sept-18


shutdown(Hood Area)

TRIM BLOWER F/H