Professional Documents
Culture Documents
National foreword
This Published Document is the UK implementation of
CEN/TR 10367:2019.
The UK participation in its preparation was entrusted to Technical
Committee ISE/102, Methods of Chemical Analysis for Iron and Steel.
A list of organizations represented on this committee can be obtained on
request to its secretary.
This publication does not purport to include all the necessary provisions
of a contract. Users are responsible for its correct application.
© The British Standards Institution 2019
Published by BSI Standards Limited 2019
ISBN 978 0 539 02919 2
ICS 77.080.20
Compliance with a British Standard cannot confer immunity from
legal obligations.
This Published Document was published under the authority of the
Standards Policy and Strategy Committee on 30 June 2019.
ICS 77.080.20
English Version
This Technical Report was approved by CEN on 19 May 2019. It has been drawn up by the Technical Committee CEN/TC 459/SC
2.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, North
Macedonia, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. CEN/TR 10367:2019 E
worldwide for CEN national Members.
PD CEN/TR 10367:2019
CEN/TR 10367:2019 (E)
Contents Page
European foreword....................................................................................................................................................... 3
1 Scope .................................................................................................................................................................... 4
2 Normative references .................................................................................................................................... 4
3 Terms and definitions ................................................................................................................................... 4
4 Principle ............................................................................................................................................................. 5
5 Reagents ............................................................................................................................................................. 5
6 Apparatus........................................................................................................................................................... 6
7 Sampling ............................................................................................................................................................. 6
8 Procedure........................................................................................................................................................... 7
9 Determination .................................................................................................................................................. 9
10 Expression of the results ........................................................................................................................... 10
11 Test report ...................................................................................................................................................... 11
Annex A (informative) Plasma optical emission spectrometer - Suggested performance
criteria to be checked ................................................................................................................................. 13
Annex B (informative) Composition of the samples used for the validation precision test............. 15
Bibliography ................................................................................................................................................................. 17
2
PD CEN/TR 10367:2019
CEN/TR 10367:2019 (E)
European foreword
This document (CEN/TR 10367:2019) has been prepared by Technical Committee CEN/TC 459/SC 2
“Methods of chemical analysis for iron and steel”, the secretariat of which is held by SIS.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
3
PD CEN/TR 10367:2019
CEN/TR 10367:2019 (E)
1 Scope
This document specifies an inductively coupled plasma optical emission spectrometric method for the
determination of the chromium content (mass fraction) between 5,0 % (m/m) and 27,0 % (m/m) in
alloyed steels.
The method doesn't apply to alloyed steels having carbon contents higher than 1 % and niobium and/or
tungsten contents higher than 0,1 %.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN ISO 648, Laboratory glassware — Single-volume pipettes
EN ISO 14284, Steel and iron — Sampling and preparation of samples for the determination of chemical
composition (ISO 14284)
4
PD CEN/TR 10367:2019
CEN/TR 10367:2019 (E)
4 Principle
Dissolution of a test portion with hydrochloric and nitric acids. Filtration and ignition of the acid
insoluble residue. Removal of silica with hydrofluoric acid. Fusion of the residue with potassium
hydrogen sulphate (or with potassium disulphate), acid dissolution of the melt and addition of this
solution to the reserved filtrate.
After suitable dilution and, if necessary, addition of an internal reference element, nebulisation of the
solution into an inductively coupled plasma optical emission spectrometer and measurement of the
intensity of the emitted light (including, where appropriate, that of the internal reference element).
The method uses a calibration based on a very close matrix matching of the calibration solutions to the
sample and bracketing of the mass fractions between 0,95 to 1,05 of the approximate content of
chromium in the sample to be analysed. The content of all elements in the sample has, therefore, to be
approximately known. If the contents are not known, the sample has to be analysed by some
semi-quantitative method. The advantage with this procedure is that all possible interferences from the
matrix will be compensated, which will result in high accuracy. This is most important for spectral
interferences, which can be severe in very highly alloyed matrixes. All possible interferences shall be
kept at a minimum level. Therefore, it is essential that the spectrometer used meets the performance
criteria specified in the method for the selected analytical lines.
The wavelengths reported in Table 1 have been investigated and the strongest possible interferences
are given. If other wavelengths are used, they shall be carefully checked. The wavelength for the
internal reference element should be selected carefully. The use of scandium at 363,1 nm or yttrium at
371,0 nm is recommended. These wavelengths are interference-free for the elements and contents
generally found in alloyed steels.
5 Reagents
During the analysis, use only reagents of recognized analytical grade and only distilled water or water
of equivalent purity.
The same reagents should be used for the preparation of calibration solutions and of sample solutions.
5.1 Hydrochloric acid, HCl (ρ20 = 1,19 g/ml).
WARNING — Hydrofluoric acid is extremely irritating and corrosive to skin and mucous membranes,
producing severe skin burns which are slow to heal. In the case of contact with skin, wash well with
water, apply a topical gel containing 2,5 % (mass fraction) calcium gluconate, and seek immediate
medical treatment.
5
PD CEN/TR 10367:2019
CEN/TR 10367:2019 (E)
Weigh, to the nearest 0,001 g, 2 g of high purity chromium [min 99,9 % (mass fraction)], place it in a
beaker and add 100 ml of hydrochloric acid (5.1). Cover with a watch glass and heat gently until
chromium is completely dissolved. After cooling, transfer the solution quantitatively into a 200 ml one-
mark volumetric flask, dilute to the mark with water and mix well.
1 ml of this solution contains 10 mg of chromium.
5.8 Chromium standard solution, 5 g/l
Weigh, to the nearest 0,001 g, 1 g of high purity chromium [min 99,9 % (mass fraction)], place it in a
beaker and add 50 ml of hydrochloric acid (5.1). Cover with a watch glass and heat gently until
chromium is completely dissolved. After cooling, transfer the solution quantitatively into a 200 ml one-
mark volumetric flask, dilute to the mark with water and mix well.
1 ml of this solution contains 5 mg of chromium.
5.9 Standard solutions of matrix elements
Prepare standard solutions for each element whose content (mass fraction) in the test sample is higher
than 1 %. Use pure metals or chemical substances with chromium contents (mass fractions) less than
100 μg/g.
5.10 Internal reference element solution, 1 g/l
Choose a suitable element to be added as internal reference and prepare a 1 g/l solution.
NOTE Elements such as Sc and Y are often used for this purpose.
6 Apparatus
All volumetric glassware shall be class A and calibrated in accordance with EN ISO 648 or EN ISO 1042
as appropriate.
6.1 Fine texture filter paper.
This shall be equipped with a nebulisation system. The instrument used will be satisfactory if, after
optimizing in accordance with the manufacturer’s instructions, it meets the performance criteria given
in Annex A.
The spectrometer can be either a simultaneous or a sequential one. If a sequential spectrometer can be
equipped with an extra arrangement for simultaneous measurement of the internal reference element
intensity, it can be used with the internal reference method. If the sequential spectrometer is not
equipped with this arrangement, an internal reference cannot be used and an alternative measurement
technique without internal reference element shall be used.
7 Sampling
Sampling shall be carried out in accordance with EN ISO 14284 or with an appropriate national
standard for steels.
6
PD CEN/TR 10367:2019
CEN/TR 10367:2019 (E)
8 Procedure
NOTE 2 Depending on the composition of each sample, larger amounts of potassium hydrogen sulphate or
potassium disulphate (5.6) can be used, provided the same amount is added to the corresponding calibration
solutions.
Allow the crucible to cool and add about 10 ml of water and 2 ml of hydrochloric acid (5.1) to the
solidified melt. Heat gently, in order to dissolve the fusion products. Allow the crucible to cool and
quantitatively add the solution to the filtrate in the 200 ml one-mark volumetric flask.
NOTE 3 The volume of hydrochloric acid (5.1) can be increased, provided the same volume is added to the
corresponding calibration solutions.
NOTE 4 If an internal reference element is used, an appropriate volume of the internal reference element
solution (5.10) can be added at this stage. In this case, omit this operation when diluting the sample solution.
7
PD CEN/TR 10367:2019
CEN/TR 10367:2019 (E)
If an internal reference element is used, add, with a calibrated pipette, 10 ml of the internal reference
element solution (5.10).
NOTE 6 Depending on the instrument performances, the volume and/or the concentration of the internal
reference element solution could be different.
Prepare two calibration solutions labelled K28 and K0, matrix matched to the test sample solution as
follows:
Add 14 ml of the chromium standard solution (5.7) in a 400 ml beaker, labelled K28.
In each 400 ml beaker, K28 and K0, add the volumes of the standard solutions (5.9) necessary to match
the sample matrix to be tested, for each element whose content is above 1%.
The matrix shall be matched to the nearest percent.
Add in each 400 ml beaker, 15 ml of hydrochloric acid (5.1) and 10 ml of nitric acid (5.2). Cover with a
watch glass and boil until nitrous fumes have been expelled and, if necessary, until the volume of the
solutions is sufficiently reduced. After cooling, add about 20 ml of water and transfer each solution into
a 200 ml one-mark volumetric flask.
Dissolve into each flask 1,00 g of potassium hydrogen sulphate or potassium disulphate (5.6) and add
2 ml of hydrochloric acid (5.1).
Dilute to the mark with water and mix.
Transfer 20 ml of each solution K28 and K0 into two 100 ml one-mark volumetric flasks and add 10 ml
of hydrochloric acid (5.1).
If an internal reference element is used add 10 ml of the internal reference element solution (5.10).
NOTE Depending on the instrument performances, the volume and/or the concentration of the internal
reference element solution could be different.
For each test solution TCr, prepare two matrix matched calibration solutions, Tl,Cr and Th,Cr with
chromium concentrations in Tl,Cr slightly below and in Th,Cr slightly above the concentration in the
unknown test solution as follows:
Add the chromium standard solution (5.7 or 5.8) in a 400 ml beaker marked Tl,Cr so that the mass
fraction of chromium Kl,Cr, in %, is approximately KCr x 0,92 < Kl,Cr < KCr x 0,98. Select Kl,Cr in such a
way to take an easy volume with a pipette.
8
PD CEN/TR 10367:2019
CEN/TR 10367:2019 (E)
Add the chromium standard solution (5.7 or 5.8) in a 400 ml beaker marked Th,Cr so that the mass
fraction of chromium Kh,Cr, in %, is approximately KCr x 1,02 < Kh,Cr < KCr x 1,08. Select Kh,Cr in such a
way that the corresponding volume can be easily pipetted.
Add to the calibration solutions Tl,Cr and Th,Cr all matrix elements whose contents (mass fractions) are
above 1 % in the test solution, using the appropriate volume of standard solutions (5.9) to match the
equivalent matrix composition to the nearest %.
Continue as specified in 8.3: “Add in each 400 ml beaker 15 ml of hydrochloric acid (5.1), 10 ml of nitric
acid (5.2)…”
9 Determination
Depending on the instrument configuration, these parameters may include the outer, intermediate or
central gas flow-rates; the torch position; the entrance slits; the exit slits and the photomultiplier tubes
voltage.
Other wavelengths may be used provided that interferences, sensitivity, resolution and linearity criteria
have been carefully investigated.
Prepare the software for measurements of the intensity, and for the calculation of the mean value and
relative standard deviation corresponding to the appropriate wavelength.
Each time the internal reference element is used, prepare the software to calculate the ratio between
the intensity of the analyte and the intensity of the internal reference element.
9.2 Measurement of test solutions
Measure the absolute or ratioed intensity of the analytical line for the low calibration solution Tl,Cr
firstly, then for the test sample solution TCr and finally for the high calibration solution Th,Cr. Repeat this
sequence three times and calculate the mean intensities Il,Cr and Ih,Cr for the low and high calibration
solutions and ICr for the test solution respectively.
9
PD CEN/TR 10367:2019
CEN/TR 10367:2019 (E)
Calculate the concentration of chromium KCr in %, in the test solution TCr, using Formula (2):
10.2 Precision
Ten laboratories in six European countries participated in an inter laboratory validation test
programme under the auspices of ECISS/TC 102/WG 10, involving three determinations of chromium
at twelve content levels (samples).
Each laboratory carried out two determinations under repeatability conditions as defined in
ISO 5725-1, i.e. one operator, same apparatus, identical operating conditions, same calibration and a
minimum period of time. The third determination was carried out on a different day using the same
apparatus with a different calibration.
The compositions of the samples used are given in Annex B.
The results obtained were statistically evaluated in accordance with ISO 5725-2, ISO 5725-3 and
CEN/TR 10345 and are reported in Table 2.
Although the reproducibility appears satisfactory as most of the “experimental” CV(R) values are
situated between the Aim and the Max CV (R) or even below Aim CV (R) several anomalies are to be
underlined:
— for five samples “r” is greater than “Rw”;
— for the same level of content (samples Cr-6 to Cr-8), the reproducibility varies from 0,21 % to
0,66 %.
Moreover, the logarithmic relationships between chromium content levels and the corresponding
precision parameters have nearly no correlation as shown below:
— lg r = 0,698 lg m – 1,695 [correlation coefficient = 0,38];
10
PD CEN/TR 10367:2019
CEN/TR 10367:2019 (E)
11 Test report
The test report shall contain the following information:
a) identification of the test sample;
c) results;
e) any operation not included in this document or in the document to which reference is made or
regarded as optional;
f) date of the test and/or date of preparation or signature of the test report;
11
CEN/TR 10367:2019 (E)
SAMPLE Cr-1 Cr-2 Cr-3 Cr-4 Cr-5 Cr-6 Cr-7 Cr-8 Cr-9 Cr-10 Cr-11 Cr-12
PD CEN/TR 10367:2019
Mean (%) 4,974 7,949 11,978 14,714 16,818 18,048 18,097 18,344 20,887 22,288 24,654 26,720
σ (r), % 0,026 0,026 0,064 0,071 0,020 0,051 0,035 0,048 0,061 0,076 0,062 0,138
σ (Rw), % 0,042 0,045 0,047 0,046 0,023 0,055 0,045 0,042 0,043 0,088 0,064 0,116
σ (R), % 0,088 0,119 0,072 0,054 0,048 0,101 0,076 0,237 0,143 0,140 0,115 0,165
r, % 0,074 0,071 0,178 0,199 0,055 0,143 0,097 0,134 0,171 0,213 0,175 0,385
Rw, % 0,106 0,126 0,133 0,129 0,065 0,155 0,125 0,118 0,120 0,246 0,181 0,325
R, % 0,246 0,332 0,202 0,151 0,135 0,281 0,214 0,633 0,401 0,393 0,324 0,462
CV (R) 1,76 1,49 0,60 0,37 0,29 0,56 0,42 1,29 0,69 0,63 0,47 0,62
Aim CV (R) 0,85 0,72 0,62 0,58 0,56 0,54 0,54 0,54 0,52 0,50 0,49 0,47
Max CV (R) 1,86 1,58 1,37 1,28 1,22 1,19 1,19 1,18 1,13 1,11 1,07 1,04
12
PD CEN/TR 10367:2019
CEN/TR 10367:2019 (E)
Annex A
(informative)
(
FWHM (d λ / dx ) w i + w u / 2
= ) (A.1)
where
wi and wu are the widths of the entrance slit and exit slit respectively; and
where
L is the focal length of the spectrometer;
13
PD CEN/TR 10367:2019
CEN/TR 10367:2019 (E)
In inductively coupled plasma optical emission spectrometry, for solutions with concentrations of at
least twice the background-equivalent concentration (BEC), RSDI values between 0,3 % and 1,0 % are
generally accepted. Multi-elemental calibration solutions may be used for measurement at various
analytical lines present in simultaneous spectrometers.
Long term stability assessment is a measurement of the instrument drift. This is only required if the
spectrometer is set up to work for long intervals of time. It consists of carrying out the same short-term
stability tests at specific intervals of time, 15 min to 1 h, and plotting the deviation of the average found
for every short-term test against time. Deviations of more than 2 % per hour should not be accepted. In
case the instrument is not able to perform better, a control calibration solution should be measured
more often during the analysis and the mean results of the test solutions should be recalculated by
interpolation between two consecutive control calibration solutions.
Values of short-term stability from 0,15 % to 0,99 % were obtained during the precision test program.
where
IBG is the intensity of the background;
Inet is the intensity of the analyte (overall intensity minus intensity of the background);
CAnalyte is the concentration of analyte that yields Inet.
Background equivalent concentration values for the elements to be analysed can be found in
wavelength tables (usually part of the instrument software). The background equivalent concentration
is the better the smaller its numerical value is.
Values of background equivalent concentration between 0,08 mg/l and 1,3 mg/l were obtained during
the precision test program.
14
PD CEN/TR 10367:2019
CEN/TR 10367:2019 (E)
Annex B
(informative)
15
CEN/TR 10367:2019 (E)
Table B.1 — Compositions of the samples used for the validation precision test
Sample n° Cr C Si Mn P S Mo Ni Al As B Co Cu N Nb Sn Ti V Others Fe
W
PD CEN/TR 10367:2019
Cr-1 approximately
5,0 0,37 0,92 0,44 0,012 0,000 5 1,3 0,16 0,023 0,006 0,014 0,14 0,014 0,008 0,002 0,85 approximately
[ECRM 271-1] 91,0
0,005
W
Cr-2 approximately
8,0 1,6 1,1 0,40 0,015 0,010 1,5 0,08 0,028 0,077 4,0 approximately
[ECRM 274-1] 83,5
0,009
0,004 0,020
W
Cr-3 approximately
12,0 2,1 0,26 0,29 0,024 0,001 0,11 0,30 0,012 0,007 0,018 0,060 0,055 approximately
[ECRM 288-1] 84,0
0,68
Cr-4 approximately
14,7 0,034 0,38 0,78 0,013 0,000 4 0,25 4,9 0,003 0,039 3,05 0,044 0,22 0,002 0,051
[ECRM 273-1] 75,5
Cr-5 approximately
16,8 0,020 0,54 1,75 0,026 0,024 2,1 10,7 0,003 0,006 0,003 0,053 0,18 0,015 0,005 0,19 0,043
[ECRM 284-2] 68,0
W
Cr-6 approximately
18,1 0,014 0,37 1,3 0,018 0,025 0,30 10,1 0,003 0,005 0,002 0,040 0,094 0,044 0,004 0,001 0,070 approximately
[ECRM 231-2] 69,5
0,015
Cr-7 approximately
18,1 0,10 1,9 0,026 0,28 0,33 8,5 0,15 0,043 0,008
[ECRM 286-1] 70,5
Cr-8 approximately
18,4 0,022 0,34 0,90 0,014 0,010 0,29 12,3 0,020 0,004 1,15 0,041 0,20 0,015 0,007 0,054
[ECRM 297-1] 66,0
Cr-9 approximately
20,9 0,074 1,5 0,54 0,020 0,000 7 0,21 10,9 0,069 0,11 0,14 0,026
[ECRM 270-1] 65,5
Zr
Cr-10 approximately
22,3 0,015 0,30 0,27 0,015 0,000 2 0,019 0,17 5,3 0,005 0,000 2 0,019 0,038 0,02 0,13 0,033 approximately
[ECRM 299-1] 71,0
0,18
Cr- approximately
24,7 0,015 0,26 0,40 0,020 0,000 6 3,8 7,1 0,029 0,002 0,055 0,20 0,26 0,004 0,004 0,001 5 0,060
11[ECRM 298-1] 63,0
Cr-12 approximately
26,8 0,012 0,39 1,8 0,017 0,000 6 3,3 30,8 0,002 0,039 0,98 0,055 0,002 0,066
[ECRM 379-1] 35,5
16
PD CEN/TR 10367:2019
CEN/TR 10367:2019 (E)
Bibliography
[1] EN 10188, Chemical analysis of ferrous materials — Determination of chromium in steels and
irons — Flame atomic absorption spectrometric method
[2] CEN/TR 10345, Guideline for statistical data treatment of inter laboratory tests for validation of
analytical methods
[3] EN 10361, Alloyed steels — Determination of nickel content — Inductively coupled plasma optical
emission spectrometric method
[4] EN ISO 3696, Water for analytical laboratory use — Specification and test methods (ISO 3696)
[5] ISO 5725-1, Accuracy (trueness and precision) of measurement methods and results — Part 1:
General principles and definitions
[6] ISO 5725-2, Accuracy (trueness and precision) of measurement methods and results — Part 2:
Basic method for the determination of repeatability and reproducibility of a standard measurement
method
[7] ISO 5725-3, Accuracy (trueness and precision) of measurement methods and results — Part 3:
Intermediate measures of the precision of a standard measurement method
[8] ISO 11435, Nickel alloys — Determination of molybdenum content— Inductively coupled
plasma/atomic emission spectrometric method
[9] ISO 13899-2, Steel — Determination of Mo, Nb and W contents in alloyed steel — Inductively
coupled plasma atomic emission spectrometric method — Part 2: Determination of Nb content
[10] ISO 22033, Nickel alloys — Determination of niobium — Inductively coupled plasma atomic
emission spectrometric method
17
NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW
Buying standards PLUS is an updating service exclusive to BSI Subscribing Members. You will
automatically receive the latest hard copy of your standards when they’re
You can buy and download PDF versions of BSI publications, including British revised or replaced.
and adopted European and international standards, through our website at
bsigroup.com/shop, where hard copies can also be purchased. To find out more about becoming a BSI Subscribing Member and the benefits
of membership, please visit bsigroup.com/shop.
If you need international and foreign standards from other Standards Development
Organizations, hard copies can be ordered from our Customer Services team. With a Multi-User Network Licence (MUNL) you are able to host standards
publications on your intranet. Licences can cover as few or as many users as you
Copyright in BSI publications wish. With updates supplied as soon as they’re available, you can be sure your
documentation is current. For further information, email subscriptions@bsigroup.com.
All the content in BSI publications, including British Standards, is the property
of and copyrighted by BSI or some person or entity that owns copyright in the Revisions
information used (such as the international standardization bodies) and has
formally licensed such information to BSI for commercial publication and use. Our British Standards and other publications are updated by amendment or revision.
Save for the provisions below, you may not transfer, share or disseminate any We continually improve the quality of our products and services to benefit your
portion of the standard to any other person. You may not adapt, distribute, business. If you find an inaccuracy or ambiguity within a British Standard or other
commercially exploit, or publicly display the standard or any portion thereof in any BSI publication please inform the Knowledge Centre.
manner whatsoever without BSI’s prior written consent.
Useful Contacts
Storing and using standards Customer Services
Standards purchased in soft copy format: Tel: +44 345 086 9001
• A British Standard purchased in soft copy format is licensed to a sole named Email (orders): orders@bsigroup.com
user for personal or internal company use only. Email (enquiries): cservices@bsigroup.com
• The standard may be stored on more than 1 device provided that it is accessible Subscriptions
by the sole named user only and that only 1 copy is accessed at any one time. Tel: +44 345 086 9001
• A single paper copy may be printed for personal or internal company use only. Email: subscriptions@bsigroup.com
• Standards purchased in hard copy format:
Knowledge Centre
• A British Standard purchased in hard copy format is for personal or internal Tel: +44 20 8996 7004
company use only.
Email: knowledgecentre@bsigroup.com
• It may not be further reproduced – in any format – to create an additional copy.
This includes scanning of the document. Copyright & Licensing
If you need more than 1 copy of the document, or if you wish to share the Tel: +44 20 8996 7070
document on an internal network, you can save money by choosing a subscription Email: copyright@bsigroup.com
product (see ‘Subscriptions’).
BSI Group Headquarters
389 Chiswick High Road London W4 4AL UK