Error Codes - Sandpiper II
Code Type Description Comment Tip 1 Tip 2 Tip 3
Error Codes, blinking in the money display
E1 SU W&M RAM Database Corrupted Warmstart (F1, F2)
E4 SU One or more tasks not started Warmstart (F1, F2) Check hardware and configuration
Pulsar Disconnected or SIP Magnet Check Pulsar for Tempering, Reboot Check pulser connection on the IS-
20 ME Pulser Disconnected Change the IS-HUB
Dropout for SIP, Check HW HUB
5118 ME PPU Board Communication Failure Check PPU board connections Check CC91.15
Additional release signal from printer
5120 ME Fiscal Printer release lost Check transaction records Check printer
(option Poland). Transaction fault!
Density, Transaction or Preset
5124 ME Multi PPU Display error Check connections Check CC91
Display Communication Failure
5130 MA Display Board Error Warmstart (F1, F2) Check the eventlog change the display
Preset Keypad enabled but not
5131 ME Check connection Check Command Code 22.1 Check/change keypad
connected
Stop button configured but hardware Check Connection and Configuration
5137 MA
not present (CC91 FC5)
5139 MA STOP-Button stuck Check button and wiring
5147 MA Vibration Sensor Alarm (UK) Check Vibration Sensor Connection
Too many nozzle signals at the
5150 ME Change the IS-HUB board
same time
Check connection between Display
5174 ME Totalizer board not present Check CC 91.11
and EMT Board
Open the Security Switch +
5175 MA Etote Board retrofitted
Warmstart (F1, F2)
5176 ME Etote Board exchanged Warmstart (F1, F2)
5182 ME Communication error to Etote Board
Totalizer connected but no return Check Totalizer, Display Board and
5183 ME Check Totalizer Check Display Board
pulse control Connections
In use for Satellite with display and
5211 MA Slave display communication fault Check Command Code 92 and 91.4 Check connections
dispenser with 4 displays
Open the Security Switch +
5230 ME Totalizer CRC per nozzle corrupted CRC-Checksumm Test
Warmstart (F1, F2)
5413 ME Unit price on zero Check POS setting Check Command Code 20 Check Command Code 94
Fuel Density not set but Vapour
5600 SU Check Command Code 75
Recovery and/or ATC is set
Range: -50°C bis +70°C. Typical
ATC = Automatic Temperatur
measuring values: 5°C = 101,95
5601 ME ATC Temperatur out of range Compensation. PT100 (0°C = 100Ohm). Check connections Change ATC Hub and/or probe
Ohm, 10°C = 103,9 Ohm, 15°C =
Resitor values don't change proportional!
105,85 Ohm, 20°C = 107,79 Ohm
Display Board software error or Open the Security Switch +
5603 MA Comes up after display change F1, 0, 1, 2, 8, Enter then F2 Check Display Board and CPU
version changed Warmstart (F1, F2)
ATC = Automatic Temperatur
5604 ME ATC probe short cut Compensation. PT100 (0°C = 100Ohm). Check connections Change probe among each other Change probe
Resitor values don't change proportional!
Multi-Wire Board communication
5700 MA Check board and connections Check Command Code 24
failure
5701 MA Multi-Wire-Board unconfigured Check Command Code 24 Check Command Code 40.6-40.13
Check Multiwire Board Hardware and
5702 MA Multi-Wire Board device error Check board and connections
Connections
INFO 1: Within the error codes we distinguish between different types (second column): INFO (IN), MINOR (MI), MEDIUM (ME), MAJOR (MA) and SUPERMAJOR (SU). INFO and MINOR events are no real errors
and will not blink in the PPU display, but will be saved in the eventlog. MEDIUM and MAJOR events are real errors and will flash in the PPU display, if they appear. SUPERMAJOR events are real errors as well, but
they will flash in the money display and will be indicated with an E.. (Example: E10).
MEDIUM events will get a reset by nozzle out and will not appear again, if the causer was eliminated. MAJOR and SUPERMAJOR events will get a reset by power reset or warmstart (press F1+F2, one after another)
and will not appear again, if the causer was eliminated.
INFO 2: Errors which are indicated by CNG*: will flash in the PPU display and generate an error signal for the compressor control system, when the error appeared 3 times. This must not be the same 3 times the
same error. Example 1: three times error 5804 = error signal. Example 2: one time error 5804, one time error 5807 and one time error 5808 = error message. Errors which are indicated by CNG: will generate
immediately an error signal for the compressor control system.
For further questions regarding error codes, please contact Gilbarco Techsupport in Salzkotten (Mail: emea.techsupport@gilbarco.com , Phone: 0049 (0) 5258 13 444)