In some cases it may be necessary to replace the reversing relay by an FI in order to realize
different speeds.
For a troublefree replacing of an MKM with electronic reversing relay by an inverter, the
response of the output shall have the same meaning for the operating condition.
Normally the inverter appropriately signals the status „ ready to operate“.
NORDAC SK500E
For a certain period NORDAC inverters had been used, because Emerson devices were not
available.
The output with NORDAC is normally switched to „ready to operate“ (view below).
To invert the signal also in this case the relay polarity is to be altered (Par. 442). Normally this
is not made at the time of pre-parameterization.
7 = Trouble (opens),
Total trouble message, trouble is active or not yet acknowledged.
Æ ready to operate - closes
Æ The setting for the output should better read „ready to operate“.