Professional Documents
Culture Documents
HPS Express G Energy Efficient Commercial Distribution Transformer Brochure
HPS Express G Energy Efficient Commercial Distribution Transformer Brochure
Typical Applications
The new HPS Express G is best suited to satisfy the needs of
typical electrical power distribution applications including:
Energy Efficiency
Small Power Shopping
Lighting HVAC
This product line meets or exceeds the latest energy efficiency Distribution Plazas
requirements prescribed by the Natural Resources Canada (NRCan),
and the Ontario Green Energy Act.
2
Data subject to change without notice.
Installation made fast and easy!
Separate High Voltage &
Wall Mounting Conduit Low Voltage Terminal Boards
Brackets Standard Type Knock-Outs for Safe & Easy Wiring
(Optional) 3R Enclosure (Where Applicable) Drip Shield (Where Applicable)
Factory Installed Innovative Cost Vibration Isolation Pads Floor Installer Friendly Outward Pre-Installed Lugs
Grounding Lugs Saving Design Mounting Feet Facing Offset Enclosure (Standard)
(Standard) Mounting Holes
kVA: 15-250kVA single phase; Termination: Front accessible high and low voltage
15-450kVA three phase terminals; lugs provided standard;
connectors suitable for aluminum and
UL Listed: File: E112313
copper are provided for easy cable
CSA Certified: File: LR3902 installation.
Conduit Side knock-outs provided where
Frequency: 60 Hz
applicable
Entry:
Insulation 220°C (150°C rise)
Impedance: Typically 3% to 6.5%
System:
Mounting: Floor mounting standard/wall
Enclosure Type: Heavy duty ventilated Type 3R mounting optional.
standard Refer to selection tables for details.
Enclosure Finish: ANSI 61 Grey, UL50 Sound Level: Meets NEMA ST-20 standards
3
Data subject to change without notice.
Selection Tables
HPS Express G
Single Phase
4
Data subject to change without notice.
Selection Tables
HPS Express G
Three Phase
5
Data subject to change without notice.
Enclosure Drawings
CN Series
[1422]
[1422]
[1422]
[1422]
6
Data subject to change without notice.
[50.8]
[1422]
37.8 30.0 26.0 48.4 33.40 3.00 23.4 6.8 1.0 2.0 x 3.0 K.O. 24 28
CN6 [960] [762] [660] [1229] [848] [76] [594] [172] [25] [50 x 76 K.O.] [609] [711]
[50.8]
[50.8]
[1727]
Dimensions in Inches [mm]
41.80 36.0 32.0 56.1 30.0 8.0 8.0 5.0 5.9 0.8 30.0 34.5
CN7 [1061] [914] [812] [1429] [762] [203] [203] [127] [149] [20] [762] [876]
7
Data subject to change without notice.
Single Phase Three Phase
1A = 0.28” Dia.
1B = 0.44” Dia.
0.56” x 1.0 Slot (Qty. 4)
0.56” Dia. (Qty. 2)
8
Data subject to change without notice.
Wall Mounting Kits
The CN1, CN2 and CN3 enclosures are designed with optional wall mounting capabilities. The “MB” dimensions listed in the
table below indicate the location for the wall mounting hardware. The “MA” dimensions shown in the figure indicate the
locations for the drip plate mounting hardware.
Note: When mounting the CN1, CN2, or CN3 type enclosures on the wall, a bottom drip plate must also be installed as shown
in the attached drawing. Please refer to CSA 22.2 No. 47-2013 requirements. The installation of these transformers above floor
level without a bottom drip plate is not permitted. All mounting hardware should be rated Grade 8 or higher.
9
Data subject to change without notice.
Anti-Vibration Pad &
Vibration Isolator Kits
Transformer
Part No. Description
Weight Lbs [kg]
NMP1 Up to 340 lbs
[154]
NMP2 341 to 680 lbs
[341 to 308]
NMP3 681 to 1040 lbs
[809 to 471]
Set of four (4) molded neoprene and steel plate
NMP4 1041 to 1740 lbs
assemblies that virtually eliminate vibration noise
[472 to 789]
between the transformer and the mounting surface.
NMP5 1741 to 2330 lbs
[789 to 1056]
NMP6 2331 to 3450 lbs
[1057 to 1564]
NMP7 3451 to 4690 lbs
[1565 to 2127]
10
Data subject to change without notice.
Electrical Schematics &
Connection Drawings
SCD 1E
SCHEMATIC CONNECTIONS
% Voltage Primary Volts Connect lines to Inter-connect
HV/HT HV/HT 105.0% 504 630 H1, H2 1-2
H1 H2 H1 H2 102.5% 492 615 H1, H2 2-3
100.0% 480 600 H1, H2 3-4
5 3 1 2 4 6 5 3 1 2 4 6
97.5% 468 585 H1, H2 4-5
95.0% 456 570 H1, H2 5-6
Secondary Volts Connect lines to Inter-connect
X4 X2 X3 X1 X4 X2 X3 X1
240 X1, X4 X2-X3
120 X1 & X3, X2 & X4 X2-X4, X1-X3
120/240 X1, X2, X4 X2-X3
SCD 2E
SCHEMATIC CONNECTIONS
% Voltage Primary Volts Connect lines to Inter-connect
H2 H2 105.0% 504 630 H1, H2 1
H1 H1
102.5% 492 615 H1, H2 2
100.0% 480 600 H1, H2 3
5 4 3 2 1 5 4 3 2 1 97.5% 468 585 H1, H2 4
95.0% 456 570 H1, H2 5
Secondary Volts Connect lines to Inter-connect
X4 X2 X3 X1 X4 X2 X3 X1 240 X1, X4 X2-X3
120 X1 & X3, X2 & X4 X2-X4, X1-X3
120/240 X1, X2, X4 X2-X3
SCD 3E
SCHEMATIC CONNECTIONS
% Voltage Primary Volts Connect lines to Inter-connect
1 X2 105.0% 504 630 H1, H2, H3 1
2
3 H2
4 102.5% 492 615 H1, H2, H3 2
5
100.0% 480 600 H1, H2, H3 3
H1 X0 97.5% 468 585 H1, H2, H3 4
X1 95.0% 456 570 H1, H2, H3 5
X3 Secondary Volts Connect lines to
H3 208 X1, X2, X3
120 X1,X0 X2,X0 X3,X0
SCD 4E
SCHEMATIC CONNECTIONS
H2 % Voltage Primary Volts Connect lines to Inter-connect
X2
105.0% 630 H1, H2, H3 1-2
6
4 102.5% 516 H1, H2, H3 2-3
2
1 100.0% 600 H1, H2, H3 3-4
5
3 X0 97.5% 585 H1, H2, H3 4-5
X1 95.0% 570 H1, H2, H3 5-6
X3 Secondary Volts Connect lines to
H1 H3 208 X1, X2, X3
120 X1,X0 X2,X0 X3,X0
11
Data subject to change without notice.
EUROPE
CANADA UNITED STATES
MEXICO ASIA
MEXICO ASIA
Hammond Power Solutions Latin America S. Hammond Power Solutions Pvt. Ltd.
Av. No. 800, Parque Industrial Guadalupe Plot No 6A, Phase -1, IDA, Pashamylaram,
Guadalupe, NL, Mexico, C.P. 67190. Patancheru (M) Sangareddy, 502 307, India
Tel: (819) 690-8000 Tel: +91-994-995-0009
sales@hammondpowersolutions.com marketing-india@hammondpowersolutions.com
EXPSEL17
Feb 2023