Air consumption per blast

For Air Blaster of 150 Ltrs. capacity at pressure : 7 Kgf/Cm2.

Considering 1 atmospheric pressure : 1 Kgf/Cm2.

Free Air required per blaster : 150 x 6 = 900 Ltrs.

Considering 10 minutes blast cycle i.e. 6 blasts per hour

= 900 x 6 = 5400 Ltr/Hr.


= 5.4 M3/Hour

For a set of 10 Nos. 150 Ltrs. Cap. Air Blaster = 5.4 x10 = 54 M3/Hour.

Electrical requirements

Power supply to AMS/SQT - 110 / 230 V AC

The Coil of Solenoid Valve (24 V DC).


Cable requirement
1 AMS/SQT to pneumatic panel 4/5 core armed 1.5 Sq.mm
2 Power supply to AMS/SQT 3 core armed 1.5 sq mm

Note : The length of the cable required shall be decided as per the
location of the pneumatic panels and AMS/SQT.