You are on page 1of 1

Test Report Page 1 of 1

ULR - TC654624000002874F
Test Report No. 24003230 Report date 20-02-2024
Cust. Name & Add. M/s Fledon Engineering Works
Vasai Municipal Ind.Estate, Plot No.44, Papdy Vasai(W).
Ref./Challan No. 168 Challan Date 20-02-2024 Sample Received On 20-02-2024
Lab No. 24003230 Test Completed On 20-02-2024
Specification IS 2062:2011 Standard Grade E250 Quality A
Sample Description Sheet
Test : CHEMICAL ANALYSIS
Size 5 mm Thk.
ID No: 15
Chemical, Metal & Metal Alloys
CHEMICAL ANALYSIS Test Method : IS 8811:1998 (RA2018)
Result Requirement
% Carbon (C) 0.146 0.230 max.
% Silicon (Si) 0.0185 0.400 max.
% Manganese (Mn) 0.502 1.500 max.
% Phosphorus (P) 0.0137 0.045 max.

*24003230-1-1*
% Sulphur (S) 0.0039 0.045 max.
% Chromium (Cr) 0.0075
% Molybdenum (Mo) 0.0052
% Nickel (Ni) 0.0124
% Vanadium (V) 0.0018
% Copper (Cu) 0.0109
% Carbon Equivalent 0.23 0.420 max.
Remark: The material conforms to IS 2062:2011 Standard Grade E250 Quality A with respect to results of test/s
carried out.
…………..END OF REPORT………….

For BMT INSTRUMENTATION & LABORATORIES

• The above test Results related only to the sample tested in this laboratory.
• This statement of compliance is based on 95% coverage probability for the expanded unceratinty of the measured results.
• This test report is accurate to the best of our knowledge and understanding. Although every effort has been made to ensure accuracy; "BMTIL"
cannot accept responsibility for any loss, damage of other consequences resulting from use of this test report.
• The results reported are valid only at the time of & under the standard conditions of the test. Samples are not drawn by BMTIL
• The report in full or part shall not be reproduced unless written permission is obtained from BMTIL.