You are on page 1of 3

ARCHITECT:

ARCHITECTURE | PLANNING | INTERIORS


9201 CORPORATE BLVD. SUITE 150
ROCKVILLE, MD. 20850
301-590-8900 FAX: 301-590-8620
EMAIL: INFO@VSW-ARCH.COM

MEP:

1577 Spring Hill Road, Suite 510


Tysons, VA 22182
shumateengineering.com

STRUCTURAL:

A-301
-
1 1.2 2 3 4 4.8 5 5.2 6 7 7.7 8
1 1-
A-304
336'-0"
48'-0" 48'-0" 48'-0" 48'-0" 48'-0" 48'-0" 48'-0" CIVIL:

10'-8" 144'-0" 36'-7 1/4" 22'-9 5/8" 132'-7 1/8" 10'-8"

A CANOPY
BELOW

FUTURE OFFICE WOMENS TOILET MENS TOILET


37'-11"

37'-11"
39'-0"

2100 2035 SHOWER MMR CHASE


MMR CHASE 2030
2041 2230
2210

FRONT

FRONT
FRONT

FRONT
EL-2 HOUSE ELEC. STAIR 3
STAIR 2 SPR
HOUSE ELEC. 2000 2220 ST3.2
ST2.2 2126
2205
A'
CORRIDOR

10'-0"
JAN. CLOS.
2045
23'-0"

23'-0"
R3 2227
30'-9"

B
CANOPY CANOPY
BELOW BELOW
65'-0"
116'-10"

R3 06/30/2023 REVISION 3
R2 05/15/2023 REVISION 2
245'-9"

2
151'-3 3/8"

129'-5"
R1 04/24/2023 REVISION 1
A-304 FUTURE DATA HALL 1 A-302 1 03/13/2023 ISSUED FOR PERMIT AND CONSTRUCTION
2305 NO. DATE ISSUE
A-302 2

H5
9'-8" 21800 BEAUMEADE CIR,
ASHBURN, VA 20147
65'-0"

STAIR 1
ST1.2
9'-8"

STAIR 4
ST4.2
23'-0"

23'-0"
D
SPR
10'-0"

SHEAR WALL PER PRECAST DWGS. SHEAR WALL PER PRECAST DWGS.
2251
D'
EMR EL-1
R2 2252 2005
46'-0"
48'-7"

CANOPY CANOPY
BELOW FUTURE ELEC. RM. ELECTRICAL RM 6 FUTURE ELEC. RM. BELOW EXPIRATION DATE: 08.31.2023
ELEC.

36'-0"
SEAL
2400 2425 2435
FRONT

2255

PROJECT
FRONT

NORTH
EMER
2040
FRONT
FRONT

TRUE
E NORT
H

SEGMENT A SEGMENT B
12'-0" 39'-0" 71'-4" 71'-4" 71'-4" 59'-0" 10'-7"

SEGMENT C SEGMENT D
1 1.2 2.1 3.5 5.1 6.5 7.7 7.9

SEGMENT E SEGMENT F

KEY PLAN

"CONFIDENTIAL
PROPIETARY
RECORD"
JOB NO. DESIGNED BY
H5-210904 VSW
3-
FILE DRAWN BY
A-301
- SK & MG

SCALE APPROVED BY
1/16" = 1'-0" TV

TITLE

OVERALL 2ND FLOOR


PLOT DATE: 7/3/2023 10:48:22 AM

DRAWING NO

1 2ND FLOOR PLAN


A-102 SCALE: 1/16" = 1'-0" A-102
ARCHITECT:

ARCHITECTURE | PLANNING | INTERIORS


9201 CORPORATE BLVD. SUITE 150
ROCKVILLE, MD. 20850
301-590-8900 FAX: 301-590-8620
EMAIL: INFO@VSW-ARCH.COM

MEP:

1577 Spring Hill Road, Suite 510


Tysons, VA 22182
shumateengineering.com

STRUCTURAL:

A-301
-
1 2 3 4 4.8 5 5.2 6 7 7.7 8
1 1-
A-304

CIVIL:
336'-0"
48'-0" 48'-0" 48'-0" 36'-0" 12'-0" 11'-8" 36'-4" 48'-0" 48'-0"
R2

1'-0"

1'-0"
2'-0"
A

3'-7 1/4"
2'-0"

3'-5"
2'-0" 332'-0" 2'-0"

5'-9"

5'-9"
NOTE: GREEN ROOF,
REFER TO CIVIL DWGS.

28'-11"

25'-3 3/4"
9'-8" 155'-3" 14'-11" 167'-10" 9'-8"
36'-11"

36'-11"
29'-3 3/4"
23'-2"

23'-2"
39'-0"

29'-6"
12'-0" 24'-0" 8'-9 5/8" 38'-9 1/2" 31'-4 7/8" 6'-0" 29'-1" 19'-3" 3'-8" 38'-0" 6'-0" 37'-1" 28'-0 3/8" 21'-10 5/8" 24'-0" 4'-0"

6'-7"
14'-7"
EL-2

8'-0"

8'-0"

8'-0"
3000
6'-0"

A'
CORRIDOR
3045
23'-0"

23'-0"
30'-9"

GALLERY FOR EQUIPMENT IN GALLERY, REFER TO MECHANICAL AND ELECTRICAL DWGS, TYP.
LOCATION OF EQUIPMENT IS TO BE VERIFIED IN FIELD BY GC AND MEP
3300
STAIR 2 STAIR 3
ST2.3 ST3.3
B

UNISEX
RESTROOM
3309
65'-0"

MIXING BOWL
3306
116'-10"

R3 06/30/2023 REVISION 3
245'-9"

129'-5"
R2 05/15/2023 REVISION 2
A-304 1 A-302 1 03/13/2023 ISSUED FOR PERMIT AND CONSTRUCTION
DATA HALL
NO. DATE ISSUE
A-302 2 3305
C
MEDIA DCOM

3308A
3307
3307

3308B
CICO
3308
H5
9'-8" 21800 BEAUMEADE CIR,
STAIR 1 ASHBURN, VA 20147
65'-0"

ST1.3
9'-8"

STAIR 4
ST4.3
23'-0"

GALLERY FOR EQUIPMENT IN GALLERY, REFER TO MECHANICAL AND ELECTRICAL DWGS, TYP.
3310 LOCATION OF EQUIPMENTIS TO BE VERIFIED IN FIELD BY GC AND MEP

23'-0"
D
JAN. CLOS. TOILET
3105 3110 SHEAR WALL PER PRECAST DWGS. SHEAR WALL PER PRECAST DWGS.

D'
EL-1
3005
46'-0"

SPR
48'-7"

3115 FUTURE ELEC. RM. EXPIRATION DATE: 08.31.2023

36'-0"
3400 SEAL
STORAGE

PROJECT
NORTH
3100

TRUE
E NORT
H

12'-0" 39'-0" 71'-4" 71'-4" 71'-4" 59'-0" 10'-7" SEGMENT A SEGMENT B

SEGMENT C SEGMENT D
1.2 2.1 3.5 5.1 6.5 7.9 8

SEGMENT E SEGMENT F

KEY PLAN

"CONFIDENTIAL
PROPIETARY
RECORD"
JOB NO. DESIGNED BY
H5-210904 VSW
3-
FILE DRAWN BY
A-301
- SK & MG

SCALE APPROVED BY
1/16" = 1'-0" TV

TITLE

OVERALL 3RD FLOOR


PLAN
PLOT DATE: 7/3/2023 10:48:30 AM

DRAWING NO

1 3RD FLOOR PLAN


A-103 SCALE: 1/16" = 1'-0"
A-103
ARCHITECT:

ARCHITECTURE | PLANNING | INTERIORS


9201 CORPORATE BLVD. SUITE 150
ROCKVILLE, MD. 20850
301-590-8900 FAX: 301-590-8620
EMAIL: INFO@VSW-ARCH.COM

MEP:

1577 Spring Hill Road, Suite 510


Tysons, VA 22182
shumateengineering.com

STRUCTURAL:

A-301
-
1 2 3 4 4.8 5 5.2 6 7 8
1-

1
A-304
CIVIL:
336'-0"
48'-0" 48'-0" 48'-0" 36'-0" 12'-0" 11'-8" 36'-4" 48'-0" 48'-0"

1'-0"
A

1'-0"
ROOF
BELOW
9'-8" 155'-3" 14'-11" 167'-10" 9'-8"
36'-11"

36'-11"
39'-0"

24'-0" 44'-1" 51'-11" 52'-0" 44'-0" 48'-0" 48'-0" 12'-0"

A'
23'-0"

23'-0"
30'-9"

B
65'-0"

CHILLER
PLATFORM
ABOVE
116'-10"
245'-9"

129'-5"
R3 06/30/2023 REVISION 3

1/4" / 1'-0"
A-304 1 A-302 1 03/13/2023 ISSUED FOR PERMIT AND CONSTRUCTION
NO. DATE ISSUE
A-302 2

1/4" / 1'-0"
H5
21800 BEAUMEADE CIR,
ASHBURN, VA 20147
65'-0"

12'-0" 48'-0" 48'-0" 48'-0" 54'-0" 42'-0" 48'-0" 12'-0"


24" WIDE SHIPS
LADDER. ACCESS
TO HIGH ROOF
23'-0"

A-303

23'-0"
D
STAIR 1 SPR
CORRIDOR
ST1.4 4115 SHEAR WALL PER PRECAST DWGS. SHEAR WALL PER PRECAST DWGS.
4045
D' 12

12 24

ELE-1 STAIR 4
CL.
12
12

4005 ST4.4
46'-0"
48'-7"

4441
12 24

12

EXPIRATION DATE: 08.31.2023

36'-0"
SEAL
STORAGE ELECTRICAL RM 1 ELECTRICAL RM 2 ELECTRICAL RM 3 ELECTRICAL RM 4 ELECTRICAL RM 5 ELECTRICAL RM 6 ELECTRICAL RM 7 ELECTRICAL RM 8

PROJECT
4440 4400 4405 4410 4415 4420 4425 4430 4435

NORTH
E TRUE
H
NORT

12'-0" 39'-0" 71'-4" 71'-4" 71'-4" 59'-0" 10'-7" SEGMENT A SEGMENT B

1.2 2.1 3.5 5.1 6.5 7.7 7.9 SEGMENT C SEGMENT D

SEGMENT E SEGMENT F

KEY PLAN

"CONFIDENTIAL
PROPIETARY
RECORD"
JOB NO. DESIGNED BY
H5-210904 VSW
3-
FILE DRAWN BY
A-301
- SK & MG

SCALE APPROVED BY
1/16" = 1'-0" TV

TITLE

OVERALL MECHANICAL
PENTHOUSE FLOOR
PLOT DATE: 7/3/2023 10:48:40 AM

DRAWING NO

1 PH FLOOR PLAN
A-104 SCALE: 1/16" = 1'-0"