Professional Documents
Culture Documents
T1-01T1-02 T1-03 T1-04 T1-05 T1-06 T1-07 T1-08 T1-09 T1-10 T1-11 T1-12T1-13T1-14T1-15 T1-16T1-17T1-18 T1-19 T1-20T1-21 T1-22 T1-23T1-24 T1-25 T1-26 T1-27 T1-28 T1-29 T1-30T1-31T1-32 T1-33T1-34 T1-35T1-37T2-01T2-02
565 4680 50 1615 2925 1145 1130 3290 1840 3300 315 135 1415 445 2830 640 1825 640 2830 445 1415 450 3300 1840 3340 1080 2060 1695 295 1590 710 1410 1335 1330 1600
75
T1 T2
NT-1A NT-2A NT-3A NT-4A NT-5A NT-6A NT-7A
7900 7900 7900 7900 7900 7900
T3
375
3635
01
01
01
01
300
01
300
PC
PC
PC
PC
1. THIS DRAWING IS THE COPYRIGHT OF WME CONSULTANTS, AND
01
01
PC
01
PC
PC
NT-A1 MUST NOT BE RETAINED, COPIED OR USED WITHOUT THE ABOVE
PC
300
CONSULTANT'S AUTHORITY.
300
300
300
300
2. DO NOT SCALE FROM THE DRAWINGS.
3. ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS IN METRES
UNLESS NOTED OTHERWISE. ALL DIMENSIONS TO BE VERIFIED ON
375 SITE AND APPROVED BY THE ENGINEER.
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER
RELEVANT ARCHITECTURAL, STRUCTURAL, MECHANICAL AND
ELECTRICAL DRAWINGS AND ALL RELEVANT SECTIONS OF THE
SPECIFICATIONS. ANY DISCREPANCIES ARE TO BE BROUGHT TO
THE ATTENTION OF THE ENGINEER AND RESOLVED BEFORE
COMMENCEMENT OF ANY WORK.
7990
7990
04
RP-WME-ST-TWR1-00-300-01 FOUNDATION GA SECTION
02
-C
05
07
08
06
-C
T1
03
-C
-C
-C
RP-WME-ST-COMM-00-000-03 STANDARD DETAILS GENERAL NOTES - 01
01
775
775
775
775
775
775
775
775
T1
-C
-C
1125
1125
1125
T1
T1
T1
-C
T1
T1
RP-WME-ST-COMM-00-000-04 STANDARD DETAILS GENERAL NOTES - 02
T1
T1-A
350
2175
2175
1400
1045
1050
T1-B
1880
175 200 50
835
830
830
830
100
T1-C ARCH. REFERENCE DRAWING
2920
1465
3005
3005
09
11
12
915
375
10
525 525
T1
-C
-C
T1-E
-C
T1
T1
T1
375
250
375
780
780
850
1080
1080
500 930
300 1130
525 1590 500 8990
1125 485 1060 50 1180
925 830 500 3645 300 1925 450 2370 MEP. REFERENCE DRAWING
700
150
T1-G
350
2490
T1-H
350
350
300
300
350
650 650
300
350
1150
750
660
200
250
375
13
450 855
1325
-C
T1-J
T1
2850
2850
2850
T1-K
350 300
905 450 650
325
250
700 450
125
450 2700 300 300 300 300 300 200 300 450
T1-L 850
975
1075
1225
1225
300
300 1440
300
300
650 650
200
14780
200
1850
T1-M
970
350
14
450 2700
1265190 900
415
T1-N
250
2370
-C
300
500
500
14975
300
800 6090
200
T1
2750
2750
T1-P
2250
750 3345 450
T1-Q
380 730
1090 300 450
1115
850 800 8190 500 1755
500
200
275
300
325
300
100
2440
700
T1-R
830 300
325
T1-S
17
1590
250 1180
1130
1755 2730 600 300 300 600 2730 300
300
16
100
-C
250
930
15
250 250
290
-C
375
T1
50
-C
300
375
T1
1825
1825
1825
T1
18
375
300
-C
T1-T
T1
250
250
T1-U
1930
1930
130 535 1075 315 465 250 450
2920
600
T1-V 250
850
250
305
2730
19
200 50
1695
-C
T1-X 400
1285
1285
20
21
-C
-C
1790
1790
100
105
T1
T1
2775
24
25
22
775
775
-C
-C
-C
510
T1-Y
T1
T1
T1
23
26
1200
-C
-C
775
775
T1
T1
3085
2535
280
T1-Z
2110
2110
2110
700 1315 100 700
2760
700 700
02
02
02
02
02
02
02
PC
PC
PC
PC
PC
PC
600
600
600
600
600
600
02
PC
02
PC
03
02
02
NT-A
PC
PC
PC
PC
600
600
600
600
600
600
R0 06.04.2023 ISSUED FOR CONSTRUCTION RK
265 225 225 225 225 225 REV NO. DATE DESCRIPTION BY.
225 225 225 225 225 225
STATUS:
5275 5735 6260 5610 3405 1950 3405 5610 6260 5635 3380 ISSUED FOR CONSTRUCTION
PROJECT:
NT-01 NT-02 NT-03 NT-04 NT-05 NT-06 NT-07 NT-08 NT-09 NT-10 NT-11 NT-12
RIVALI PARK, PHASE III
Mumbai, India
CLIENT:
ARCHITECT:
DRAWING TITLE:
TOWER-01
BASEMENT 02- COLUMN AND WALL
SETTING OUT PLAN
DATE: SCALE @ A1: DRN BY: CHKD BY: APP BY: REVISION
06-04-2023 1 : 100 RK SP NR R0
PROJECT No: DRAWING No:
P550012 RP-WME-ST-TWR1-B2-450-00