LONG TRAVEL DRIVE ACS 850

Gr. No. Parameter No. Parameter Name Value Changed on 15.07.2019


1 0101 Motor speed rpm 0.00 RPM
0102 Motor speed % 0.00 %
0103 Output frequency 0.00 Hz
0104 Motor current 0.00 Amp
0105 Motor current % 0.00 %
0106 Motor torque 0.00 %
0107 Dc-voltage 550 V
0108 Encoder1 speed 0.00 RPM
0109 Encoder1 pos 0.00 REV
0110 Encoder2 speed 0.00 RPM
0111 Encoder2 pos 0.00 REV
2 0201 DI Status 0-0100-0100 BIN
0202 RO Status
0203 DIO Status
0204 AI1
0205 AI1 scaled
0206 AI2
0207 AI2 scaled
0208 AI3
0209 AI3 scaled
0210 AI4
0211 AI4 scaled
0212 AI5
0213 AI5 scaled
0214 AI6
0215 AI6 scaled
0216 AO1
0217 AO2
0218 AO3
0219 AO4
0220 Freq in
0221 Freq out
0222 FBA main cw
0224 FBA main sw
0226 FBA main ref1
0227 FBA main ref2
0230 D2D main cw
0231 D2D follower cw
0232 D2D ref1
0233 D2D ref2
0234 Panel ref
0235 FEN DI status
0236 EFB main cw
0237 EFB main sw
0238 EFB main ref1
0239 EFB main ref2
10 1001 Ext1 start func In1FIn2R
1002 Ext1 start in1 DI1
1003 Ext1 start in2 DI2
1004 Ext2 start func In1FIn2R
1005 Ext2 start in1 DI1
1006 Ext2 start in2 DI2
1007 Jog1 start C.False
1008 Jog2 start C.False
1009 Jog enable C.False
1010 Fault reset sel DI6
1011 Run enable C.True
1013 Em stop off3 C.True
1015 Em stop off1 C.True
1017 Start enable C.True
1019 Start inhibit Disable
1020 Start intrl func Off3 stop
11 1101 Start mode
1102 Dc-magn time
1103 Stop mode Coast Ramp
1104 Dc hold speed
1105 Dc hold curr ref
1107 Autophasing mode
12 1201 Ext1/Ext2 sel
1203 Ext1 ctrl mode
1205 Ext2 ctrl mode
1207 Local ctrl mode
13 1301 AI1 filt time 0.1 sec
1302 AI1 max 20 mA
1303 AI1 min 4 mA
1304 AI1 max scale 1500
1305 AI1 min scale 0
1306 AI2 filt time 0.100 sec
1307 AI2 max 20.00 mA
1308 AI2 min 4.0 mA
1309 AI2 max scale 1500 rpm
1310 AI2 min scale 0rpm
1311 AI3 filt time 0.100 sec
1312 AI3 max 22.00 mA
1313 AI3 min 4.00 mA
1314 AI3 max scale 1500
1315 AI3 min scale 0
1316 AI4 filt time 0.100 sec
1317 AI4 max 22.00 mA
1318 AI4 min 4.00 mA
1319 AI4 max scale 1500
1320 AI4 min scale 0
1321 AI5 filt time 0.100 sec
1322 AI5 max 22.00 mA
1323 AI5 min 4.00 mA
1324 AI5 max scale 1500
1325 AI5 min scale 0
1326 AI6 filt time 0.100 sec
1327 AI6 max 22.00 mA
1328 AI6 min 4.00 mA
1329 AI6 max scale 1500
1330 AI6 min scale 0
1331 AI tune No action
1332 AI superv func No
1333 AI superv cw 0000 bin
14 1401 DI invert mask 000 bin
1402 DIO1 conf Output
1403 DIO1 out src Ready relay
1404 DIO1 Ton 0s
1405 DIO1 Toff 0s
1406 DIO2 conf Output
1407 DIO2 out src Running relay
1408 DIO2 Ton 0s
1409 DIO2 Toff 0s
1410 DIO3 conf Output
1411 DIO3 out src Fault (-1)
1414 DIO4 conf Output
1415 DIO4 out src Ready relay
1418 DIO5 conf Output
1419 DIO5 out src Ref running
1422 DIO6 conf Output
1423 DIO6 out src Fault (-1)
1426 DIO7 conf Output
1427 DIO7 out src Alarm
1430 DIO8 conf Output
1431 DIO8 out src Ext2 active
1434 DIO9 conf Output
1435 DIO9 out src At setpoint
1438 DIO10 conf Output
1439 DIO10 out src Zero speed
1442 RO1 src Ready relay
1443 RO1 Ton 0s
1444 RO1 Toff 0s
1445 RO2 src Running relay
1448 RO3 src Fault
1451 RO4 src P.06.02.02
1454 RO5 src P.06.02.04
1457 Freq in max 1000Hz
1458 Freq in min 3Hz
1459 Freq in max scal 1500
1460 Freq in min scal 0
1461 Freq out src P.01.01
1462 Freq out max src 1500
1463 Freq out min src 0
1464 Freq out max sca 1000Hz
1465 Freq out min sca 3Hz
1466 RO6 src P.06.02.04
1469 RO7 src P.06.02.04
1472 DIO invert mask 000 bin
15 1501 AO1 src Speed rpm
1502 AO1 filt time 0.1s
1503 AO1 out max 20mA
1504 AO1 out min 4mA
1505 AO1 src max 1455rpm
1506 AO1 src min 0rpm
1507 AO2 src Current
1508 AO2 filt time 0.100 sec
1509 AO2 out max 20mA
1510 AO2 out min 4mA
1511 AO2 src max 100A
1512 AO2 src min 0A
1513 AO3 src Frequency
1514 AO3 filt time 0.100 sec
1515 AO3 out max 22 mA
1516 AO3 out min 4 mA
1517 AO3 src max 50.00
1518 AO3 src min 0.00
1519 AO4 src Frequency
1520 AO4 filt time 0.100 sec
1521 AO4 out max 22 mA
1522 AO4 out min 4 mA
1523 AO4 src max 50.00
1524 AO4 src min 0.00
1525 AO ctrl word 0000 bin
1530 AO calibration No action
16 1601 Local lock C.False
1602 Parameter lock Open
1603 Pass code 0
1604 Param restore Done
1607 Param save Done
1609 User set sel No request
1610 User set log Not available
1611 User IO sel lo C.False
1612 User IO sel hi C.False
1614 Reset ChgParLog Done
1615 Menu set sel No request
1616 Menu set active Long menu
1617 Power unit kW
1618 Fan ctrl mode Normal
1620 Drive boot No action
1623 120 s
1624 120 s
19 1901 Speed scaling 1500 rpm
1902 Speed fb sel Estimated
1903 MotorSpeed filt 8 m/sec
1906 Zero speed limit 30 rpm
1907 Zero speed delay 0 ms
1908 Above speed lim 0 rpm
1909 Speed TripMargin 500 rpm
1910 Speed window 100 rpm
1913 Speed fbk fault Fault
1914 Speed superv est 450 rpm
1915 Speed superv enc 15 rpm
1916 Speed fb filt t 15 ms
20 2001 Maximum speed 1500 rpm
2002 Minimum speed 1500 rpm
2003 Pos speed ena C.True
2004 Neg speed ena 120A
2005 Maximum current 42A
2006 Torq lim sel C.False
2007 Maximum torque1 300%
2008 Minimum torque1 300%
2009 Maximum torque2 Max torque1
2010 Minimum torque2 Min torque1
2012 P motoring lim 300 %
2013 P generating lim 300 %
21 2101 Speed ref1 sel MOT POT
2102 Speed ref2 sel AI1 scaled
2103 Speed ref1 func Ref1
2104 Speed ref1/2 sel DI3
2105 Speed share 1
2107 Speed ref jog1 0rpm
2108 Speed ref jog2 0rpm
2109 SpeedRef min abs 0rpm
2110 Mot pot func Reset
2111 Mot pot up DI4
2112 Mot pot down DI5
22 2201 Acc/Dec sel C.True
2202 Acc time1 3 ms
2203 Dec time1 10 s 60 s
2204 Acc time2 60 s
2205 Dec time2 60 s
2206 Shape time acc1 0.1s
2207 Shape time acc2 0.1s
2208 Shape time dec1 0.1s
2209 Shape time dec2 0.1s
2210 Acc time jogging 0
2211 Dec time jogging 0
2212 Em stop time 3s
30 3001 External fault C.True
3002 Speed ref safe 0
3003 Local ctrl loss Fault
3004 Mot phase loss No
3005 Earth fault Fault
3006 Suppl phs loss Fault
3007 Sto diagnostic Fault
3008 Wiring or earth No
3009 Stall function 111
3010 Stall curr lim 200%
3011 Stall freq hi 15Hz
3012 Stall time 20s
3013 13%
3014 Fault
31 3101 Mot temp1 prot
3102 Mot temp1 src
3103 Mot temp1 almLim
3104 Mot temp1 fltLim
3105 Mot temp2 prot
3106 Mot temp2 src
3107 Mot temp2 almLim
3108 Mot temp2 fltLim
3109 Mot ambient temp
3110 Mot load curve
3111 Zero speed load
3112 Break point
3113 Mot nom tempRise
3114 Mot therm time
47 4701 Overvolt ctrl Enable
4702 Undervolt ctrl Enable
4703 SupplyVoltAutoId Enable
4704 Supply voltage 400 V
4705 C.False
4706 250 V
4707 81 V
4708 C.False
48 4801 Bc enable EnableTherm
4802 Bc run-time ena Running
4803 BrThermTimeConst 300 s
4804 Br power max cnt 9 kW
4805 R br 4.4 ohm
4806 Br temp faultlim 105%
4807 Br temp alarmlim 95%
55 5501 01
5502 Auto
99 9901 Language English
9904 Motor type AM
9905 Motor ctrl mode Scalar
9906 Mot nom current 98.4 A
9907 Mot nom voltage 415V
9908 Mot nom freq 50Hz
9909 Mot nom speed 1425rpm
9910 Mot nom power 48kW
9911 Mot nom cosfii 0
9912 Mot nom torque 0
9913 IDrun mode No
9916 Phase inversion No