Gr. No. Parameter No. Parameter Name Value Changed on 15.07.2019
1 0101 Motor speed rpm 0.00 RPM 0102 Motor speed % 0.00 % 0103 Output frequency 0.00 Hz 0104 Motor current 0.00 Amp 0105 Motor current % 0.00 % 0106 Motor torque 0.00 % 0107 Dc-voltage 550 V 0108 Encoder1 speed 0.00 RPM 0109 Encoder1 pos 0.00 REV 0110 Encoder2 speed 0.00 RPM 0111 Encoder2 pos 0.00 REV 2 0201 DI Status 0-0100-0100 BIN 0202 RO Status 0203 DIO Status 0204 AI1 0205 AI1 scaled 0206 AI2 0207 AI2 scaled 0208 AI3 0209 AI3 scaled 0210 AI4 0211 AI4 scaled 0212 AI5 0213 AI5 scaled 0214 AI6 0215 AI6 scaled 0216 AO1 0217 AO2 0218 AO3 0219 AO4 0220 Freq in 0221 Freq out 0222 FBA main cw 0224 FBA main sw 0226 FBA main ref1 0227 FBA main ref2 0230 D2D main cw 0231 D2D follower cw 0232 D2D ref1 0233 D2D ref2 0234 Panel ref 0235 FEN DI status 0236 EFB main cw 0237 EFB main sw 0238 EFB main ref1 0239 EFB main ref2 10 1001 Ext1 start func In1FIn2R 1002 Ext1 start in1 DI1 1003 Ext1 start in2 DI2 1004 Ext2 start func In1FIn2R 1005 Ext2 start in1 DI1 1006 Ext2 start in2 DI2 1007 Jog1 start C.False 1008 Jog2 start C.False 1009 Jog enable C.False 1010 Fault reset sel DI6 1011 Run enable C.True 1013 Em stop off3 C.True 1015 Em stop off1 C.True 1017 Start enable C.True 1019 Start inhibit Disable 1020 Start intrl func Off3 stop 11 1101 Start mode 1102 Dc-magn time 1103 Stop mode Coast Ramp 1104 Dc hold speed 1105 Dc hold curr ref 1107 Autophasing mode 12 1201 Ext1/Ext2 sel 1203 Ext1 ctrl mode 1205 Ext2 ctrl mode 1207 Local ctrl mode 13 1301 AI1 filt time 0.1 sec 1302 AI1 max 20 mA 1303 AI1 min 4 mA 1304 AI1 max scale 1500 1305 AI1 min scale 0 1306 AI2 filt time 0.100 sec 1307 AI2 max 20.00 mA 1308 AI2 min 4.0 mA 1309 AI2 max scale 1500 rpm 1310 AI2 min scale 0rpm 1311 AI3 filt time 0.100 sec 1312 AI3 max 22.00 mA 1313 AI3 min 4.00 mA 1314 AI3 max scale 1500 1315 AI3 min scale 0 1316 AI4 filt time 0.100 sec 1317 AI4 max 22.00 mA 1318 AI4 min 4.00 mA 1319 AI4 max scale 1500 1320 AI4 min scale 0 1321 AI5 filt time 0.100 sec 1322 AI5 max 22.00 mA 1323 AI5 min 4.00 mA 1324 AI5 max scale 1500 1325 AI5 min scale 0 1326 AI6 filt time 0.100 sec 1327 AI6 max 22.00 mA 1328 AI6 min 4.00 mA 1329 AI6 max scale 1500 1330 AI6 min scale 0 1331 AI tune No action 1332 AI superv func No 1333 AI superv cw 0000 bin 14 1401 DI invert mask 000 bin 1402 DIO1 conf Output 1403 DIO1 out src Ready relay 1404 DIO1 Ton 0s 1405 DIO1 Toff 0s 1406 DIO2 conf Output 1407 DIO2 out src Running relay 1408 DIO2 Ton 0s 1409 DIO2 Toff 0s 1410 DIO3 conf Output 1411 DIO3 out src Fault (-1) 1414 DIO4 conf Output 1415 DIO4 out src Ready relay 1418 DIO5 conf Output 1419 DIO5 out src Ref running 1422 DIO6 conf Output 1423 DIO6 out src Fault (-1) 1426 DIO7 conf Output 1427 DIO7 out src Alarm 1430 DIO8 conf Output 1431 DIO8 out src Ext2 active 1434 DIO9 conf Output 1435 DIO9 out src At setpoint 1438 DIO10 conf Output 1439 DIO10 out src Zero speed 1442 RO1 src Ready relay 1443 RO1 Ton 0s 1444 RO1 Toff 0s 1445 RO2 src Running relay 1448 RO3 src Fault 1451 RO4 src P.06.02.02 1454 RO5 src P.06.02.04 1457 Freq in max 1000Hz 1458 Freq in min 3Hz 1459 Freq in max scal 1500 1460 Freq in min scal 0 1461 Freq out src P.01.01 1462 Freq out max src 1500 1463 Freq out min src 0 1464 Freq out max sca 1000Hz 1465 Freq out min sca 3Hz 1466 RO6 src P.06.02.04 1469 RO7 src P.06.02.04 1472 DIO invert mask 000 bin 15 1501 AO1 src Speed rpm 1502 AO1 filt time 0.1s 1503 AO1 out max 20mA 1504 AO1 out min 4mA 1505 AO1 src max 1455rpm 1506 AO1 src min 0rpm 1507 AO2 src Current 1508 AO2 filt time 0.100 sec 1509 AO2 out max 20mA 1510 AO2 out min 4mA 1511 AO2 src max 100A 1512 AO2 src min 0A 1513 AO3 src Frequency 1514 AO3 filt time 0.100 sec 1515 AO3 out max 22 mA 1516 AO3 out min 4 mA 1517 AO3 src max 50.00 1518 AO3 src min 0.00 1519 AO4 src Frequency 1520 AO4 filt time 0.100 sec 1521 AO4 out max 22 mA 1522 AO4 out min 4 mA 1523 AO4 src max 50.00 1524 AO4 src min 0.00 1525 AO ctrl word 0000 bin 1530 AO calibration No action 16 1601 Local lock C.False 1602 Parameter lock Open 1603 Pass code 0 1604 Param restore Done 1607 Param save Done 1609 User set sel No request 1610 User set log Not available 1611 User IO sel lo C.False 1612 User IO sel hi C.False 1614 Reset ChgParLog Done 1615 Menu set sel No request 1616 Menu set active Long menu 1617 Power unit kW 1618 Fan ctrl mode Normal 1620 Drive boot No action 1623 120 s 1624 120 s 19 1901 Speed scaling 1500 rpm 1902 Speed fb sel Estimated 1903 MotorSpeed filt 8 m/sec 1906 Zero speed limit 30 rpm 1907 Zero speed delay 0 ms 1908 Above speed lim 0 rpm 1909 Speed TripMargin 500 rpm 1910 Speed window 100 rpm 1913 Speed fbk fault Fault 1914 Speed superv est 450 rpm 1915 Speed superv enc 15 rpm 1916 Speed fb filt t 15 ms 20 2001 Maximum speed 1500 rpm 2002 Minimum speed 1500 rpm 2003 Pos speed ena C.True 2004 Neg speed ena 120A 2005 Maximum current 42A 2006 Torq lim sel C.False 2007 Maximum torque1 300% 2008 Minimum torque1 300% 2009 Maximum torque2 Max torque1 2010 Minimum torque2 Min torque1 2012 P motoring lim 300 % 2013 P generating lim 300 % 21 2101 Speed ref1 sel MOT POT 2102 Speed ref2 sel AI1 scaled 2103 Speed ref1 func Ref1 2104 Speed ref1/2 sel DI3 2105 Speed share 1 2107 Speed ref jog1 0rpm 2108 Speed ref jog2 0rpm 2109 SpeedRef min abs 0rpm 2110 Mot pot func Reset 2111 Mot pot up DI4 2112 Mot pot down DI5 22 2201 Acc/Dec sel C.True 2202 Acc time1 3 ms 2203 Dec time1 10 s 60 s 2204 Acc time2 60 s 2205 Dec time2 60 s 2206 Shape time acc1 0.1s 2207 Shape time acc2 0.1s 2208 Shape time dec1 0.1s 2209 Shape time dec2 0.1s 2210 Acc time jogging 0 2211 Dec time jogging 0 2212 Em stop time 3s 30 3001 External fault C.True 3002 Speed ref safe 0 3003 Local ctrl loss Fault 3004 Mot phase loss No 3005 Earth fault Fault 3006 Suppl phs loss Fault 3007 Sto diagnostic Fault 3008 Wiring or earth No 3009 Stall function 111 3010 Stall curr lim 200% 3011 Stall freq hi 15Hz 3012 Stall time 20s 3013 13% 3014 Fault 31 3101 Mot temp1 prot 3102 Mot temp1 src 3103 Mot temp1 almLim 3104 Mot temp1 fltLim 3105 Mot temp2 prot 3106 Mot temp2 src 3107 Mot temp2 almLim 3108 Mot temp2 fltLim 3109 Mot ambient temp 3110 Mot load curve 3111 Zero speed load 3112 Break point 3113 Mot nom tempRise 3114 Mot therm time 47 4701 Overvolt ctrl Enable 4702 Undervolt ctrl Enable 4703 SupplyVoltAutoId Enable 4704 Supply voltage 400 V 4705 C.False 4706 250 V 4707 81 V 4708 C.False 48 4801 Bc enable EnableTherm 4802 Bc run-time ena Running 4803 BrThermTimeConst 300 s 4804 Br power max cnt 9 kW 4805 R br 4.4 ohm 4806 Br temp faultlim 105% 4807 Br temp alarmlim 95% 55 5501 01 5502 Auto 99 9901 Language English 9904 Motor type AM 9905 Motor ctrl mode Scalar 9906 Mot nom current 98.4 A 9907 Mot nom voltage 415V 9908 Mot nom freq 50Hz 9909 Mot nom speed 1425rpm 9910 Mot nom power 48kW 9911 Mot nom cosfii 0 9912 Mot nom torque 0 9913 IDrun mode No 9916 Phase inversion No