1. TANK inputs
a) Wastewater characteristic
Freeboard =
Recator length to width ratio =
Ave solids concentration in process volume, XVSS = =
Design organic loading rate =
Assumed % COD removal =
Assumed Effluent VSS conc =
% COD removal =
2. Calculation ( done by the spreadsheet )
a. Calculation of SRT 25 °C
S = 5844.92 mg/L or g/m3 sCOD eff
COD from VSS = 5267.28 mg/L or g/m3
SRT = 7.37472356943217 d SRT with safety factor
non sCOD = 5844.92 mg/L or g/m3 non sCOD at VSS
Px, VSS = 585,354.507 gVSS/d
Tank Volume = 2,158.414 HRT
Reactor area = 308.344834425947 m2 Reactor width =
Reactor length = 24.8 m Total reator height =
(Table 10.3)
0.2 g/g.d Half velocity constant Ks= 360
0.08 g VSS/ gCOD
0.03 (gVSS/d)g VSS
0.15 g VSS cell debris/g VSS biomass decay
0.4 L CH4/ g COD
38846 kJ/m3
65 %
120 mg COD/L
7m
1m
2
0.6 mgVSS/L
8 (kgCOD/m3.day)
60 %
5844.92 mg/L
60 %
= 4.316827681963 d
V= 2,158.414 m3
Reactor width = 12.4 m
Total reator height = 8m
gNaHCO3/m3
kgNaHCO3/day