2,000 P + PE
Treatment Plant mec2000wwtp2 page 2
Aqua Designer mec2000wwtp2.ad2 7/6/2021
1. Basic Data
Municipal Wastewater
QS,aM =
11.75 m3/h
= 1.18 m3/h
12.93 m3/h
310.20 m3/d
QT,h,max = QF,aM +
Daily peak for dry weather, yearly average: QT,h,max = 8.84 l/s
31.83 m3/h
The hourly values are calculated with the hour index for domenstic and extraneous water
mg/l kg/d
Method of Calculation
Cleaning Process
- Intermitted Denitrification
Chosen Design
2. Biological Stage
2.1.1 Construction
Intermittend Aeration.
Concentrations
Nitrogen Balance
kg/d mg/l
Sludge Load:
Volume Load:
tRmin = = 0.753 d
= 18.08 h
Width: b = 8.00 m
Length: l = 11.80 m
Retention Time
tRmin = = 0.761 d
= 18.26 h
Verification
BR = = 0.317 kg/(m³*d)
BR = = 0.275 kg/(m³*d)
The remaining acid capacity in the outflow falls not below the recommended value of 1,5 mmol/l
according DWA..
OVd,N =
OVd,D =
Oxygen Concentrations
Standard Value for the Saturation Concentration of Oxygen (T=10°C, He=0 m):
Cs,T =
Cs = Cs,T*(1+He/20,7)
Treatment Plant mec2000wwtp2 page 14
Aqua Designer mec2000wwtp2.ad2 7/6/2021
OVh =
aOC =
Oxygen Consumption
kgO2/kgBOD5
Oxygen Transfer
The required hourly oxygen inflow will be calculated for the most unfavourable load.
= 0.65
QL = = 355.02 m³/h
Activated Chamber
Aeration
Machine data
Loads
2.2.1 Construction
Wastewater Inflow
TSBB =
Treatment Plant mec2000wwtp2 page 20
Aqua Designer mec2000wwtp2.ad2 7/6/2021
Chosen Dimensions
h1 = const. = 0.50 m
Dividing Zone:
h2 = = 2.00 m
Storage Zone:
h3 = = 0.89 m
Thickening Zone:
h4 = = 1.57 m
2.24 l/(m*s)
Treatment Plant mec2000wwtp2 page 23
Aqua Designer mec2000wwtp2.ad2 7/6/2021
Discharge Pipe
Wastewater Inflow
Values of Design
Machine data