You are on page 1of 59

Drawing Plotted: 15/10/2021 9:23:51 AM

DRAWING INDEX DRAWING INDEX


DRAWING NO. REV. NO. TITLE 3000 FOUNDATION AND RETENTION DETAILS
2790300-SE-0000 0 COVER SHEET DRAWING NO. REV. NO. TITLE
2790300-SE-0001 0 DRAWING INDEX 2790300-SE-3100 0 FOUNDATION SCHEDULE
2790300-SE-0201 0 STANDARD DRAWINGS SHEET 1 OF 9 2790300-SE-3111 0 SCHEDULE OF STRUCTURAL MEMBERS
2790300-SE-0202 0 STANDARD DRAWINGS SHEET 2 OF 9 2790300-SE-3112 0 STRIP FOOTING DETAIL (SF-1)
2790300-SE-0203 0 STANDARD DRAWINGS SHEET 3 OF 9 2790300-SE-3113 0 STRIP FOOTING DETAIL (SF-2)
2790300-SE-0204 0 STANDARD DRAWINGS SHEET 4 OF 9 2790300-SE-9302 0 RETAINING WALL DETAIL
2790300-SE-0205 0 STANDARD DRAWINGS SHEET 5 OF 9

www.beca.com
2790300-SE-0206 0 STANDARD DRAWINGS SHEET 6 OF 9
2790300-SE-0207 0 STANDARD DRAWINGS SHEET 7 OF 9
2790300-SE-0208 0 STANDARD DRAWINGS SHEET 8 OF 9
2790300-SE-0209 0 STANDARD DRAWINGS SHEET 9 OF 9
2000 PRIMARY STRUCTURE PLANS, BUILDING ELEVATINS AND SECTIONS
DRAWING NO. REV. NO. TITLE
2790300-SE-2000 0 GENERAL ARRANGEMENT KEY PLAN
2790300-SE-2100 0 OVERALL FOUNDATION LAYOUT
2790300-SE-2110 0 MAIN WAREHOUSE (WH) FOUNDATION LAYOUT (SHEET 1 OF 4)
2790300-SE-2111 0 MAIN WAREHOUSE (WH) FOUNDATION LAYOUT (SHEET 2 OF 4)
2790300-SE-2112 0 MAIN WAREHOUSE (WH) FOUNDATION LAYOUT (SHEET 3 OF 4)
2790300-SE-2113 0 MAIN WAREHOUSE (WH) FOUNDATION LAYOUT (SHEET 4 OF 4)
2790300-SE-2120 0 MAIN OFFICE AND AMENITIES (MA) BUILDING FOUNDATION LAYOUT
2790300-SE-2130 0 INBOUND DOCK OFFICE (ID) BUILDING FOUNDATION LAYOUT
2790300-SE-2140 0 OUTBOUND DOCK OFFICE (OD) BUILDING FOUNDATION LAYOUT
2790300-SE-2160 0 RETAINING WALL LAYOUT PLAN
2790300-SE-2310 0 OVERALL COLUMN LAYOUT
2790300-SE-2311 0 MAIN WAREHOUSE COLUMN LAYOUT SHEET 1 OF 4
2790300-SE-2312 0 MAIN WAREHOUSE COLUMN LAYOUT SHEET 2 OF 4
2790300-SE-2313 0 MAIN WAREHOUSE COLUMN LAYOUT SHEET 3 OF 4
2790300-SE-2314 0 MAIN WAREHOUSE COLUMN LAYOUT SHEET 4 OF 4
2790300-SE-2315 0 MAIN WAREHOUSE MEZZANINE VAZ AREA BEAM LAYOUT
2790300-SE-2316 0 MAIN WAREHOUSE ROOF CANOPY LAYOUT
2790300-SE-2318 0 MAIN WAREHOUSE ROOF LAYOUT
2790300-SE-2320 0 MA BUILDING GROUND FLOOR COLUMN LAYOUT
2790300-SE-2321 0 MA BUILDING 2ND FLOOR COLUMN LAYOUT
2790300-SE-2322 0 MA BUILDING 2ND FLOOR BEAM LAYOUT
2790300-SE-2323 0 MA BUILDING ROOF BEAM LAYOUT
2790300-SE-2330 0 INBOUND OFFICE BUILDING GROUND FLOOR COLUMN LAYOUT
2790300-SE-2331 0 INBOUND OFFICE BUILDING 2F AND 3F FLOOR COLUMN LAYOUT
2790300-SE-2333 0 INBOUND OFFICE BUILDING 2F AND 3F FLOOR BEAM LAYOUT
2790300-SE-2335 0 INBOUND OFFICE BUILDING ROOF BEAM LAYOUT
2790300-SE-2340 0 OUTBOUND OFFICE BUILDING GROUND FLOOR COLUMN LAYOUT
2790300-SE-2341 0 OUTBOUND OFFICE BUILDING 2ND FLOOR COLUMN LAYOUT
2790300-SE-2342 0 OUTBOUND OFFICE BUILDING 2ND FLOOR BEAM LAYOUT
2790300-SE-2343 0 OUTBOUND OFFICE BUILDING ROOF FRAMING LAYOUT
2790300-SE-2510 0 MAIN WAREHOUSE ELEVATION
2790300-SE-2511 0 MAIN WAREHOUSE SECTIONS SHEET 1 OF 2
2790300-SE-2512 0 MAIN WAREHOUSE SECTIONS SHEET 2 OF 2
2790300-SE-2520 0 MA BUILDING ELEVATION AND SECTION
Client:
2790300-SE-2521 0 OFFICE & AMENITIES, GENSET, MATERIALS RECYCLING FACILITY SECTIONS
2790300-SE-2530 0 INBOUND OFFICE BUILDING ELEVATIONS ORIGINAL DRAWING
IN COLOUR
2790300-SE-2531 0 INBOUND OFFICE BUILDING SECTIONS PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Document No. 2790300-SE-0001.DWG


2790300-SE-2540 0 OUTBOUND OFFICE BUILDING ELEVATIONS Project:

2790300-SE-2541 0 OUTBOUND OFFICE BUILDING SECTIONS FOR TENDER SOLID LF


Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. CIVIL INFRASTRUCTURE
0 ISSUED FOR TENDER EFG FF JG 26.05.2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
DRAWING INDEX Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-0001 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

CONSTRUCTION NOTES 3.2.5 UNLESS INDICATED OTHERWISE, SPLICING OF REINFORCEMENT SHALL BE IN ACCORDANCE 7.5 NO LOADS IN ANY MANNER WILL BE ALLOWED AT LEAST FOR THE FIRST WEEK AFTER THE SLAB HAS BEEN NON-STRUCTURAL ATTACHMENT, I.E. MEPF UTILITIES, ARCHITECTURAL AND INTERIOR ATTACHMENT,
WITH ACI STANDARD 318-2014. POURED. AFTER 7 DAYS, ONLY CONSTRUCTION LIGHT TRAFFIC WITH PNEUMATIC TIRES WILL BE PERMITTED. FOR ENGINEER OF RECORD'S APPROVAL.
1.0 GENERAL : 3.2.6 UNLESS SHOWN OTHERWISE ON PLANS, SPLICES SHALL BE AS FOLLOWS : 7.6 A PRE-CONSTRUCTION MEETING TO DISCUSS SLAB GUIDELINES IS TO BE SCHEDULED PRIOR TO SLAB POUR 12.2 DESIGN SHALL CONFORM NSCP 2015 SECTION 208.8.
A. BEAMS: TOP AND BOTTOM BARS SHALL NOT BE SPLICED WITHIN THE COLUMN BETWEEN THE RESIDENT, THE CONCRETE SUB-CONTRACTOR, THE SPECIAL INSPECTOR, THE STRUCTURAL
1.1 ALL FLOOR FINISH LEVELS ARE REFERENCED FROM PRECOS WAREHOUSE BUILDING. ENGINEER, THE SOILS ENGINEER, THE CONCRETE PRE-MIX SUPPLIER AND THE MATERIALS TESTING LOADING CRITERIA :
OR WITHIN A DISTANCE OF TWICE THE MEMBER DEPTH FROM THE FACE
1.2 ALL DIMENSIONS ARE SHOWN IN MILLIMETERS, ELEVATIONS ARE IN METERS, UNLESS NOTED OTHERWISE. OF THE COLUMN; AT LEAST TWO EXTRA STIRRUP-TIES SHALL BE LABORATORY. 1. DEAD LOADS
1.3 THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE, AND SHALL PROVIDED AT ALL SPLICES, THE SPLICE LENGTH SHALL NOT BE LESS 7.7 VIBRATORY SCREENING SHOULD BE USED. - REINFORCED CONCRETE = 24.0 KN/m3
NOTIFY THE STRUCTURAL CONSULTANT OF DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND INFO- THAN THE LENGTH IN ITEM 3.2.9 BELOW. 7.8 PROVIDE THE CAPACITY TO SPRAY MIST DURING THE POURING, FINISHING AND CURING OF THE CONCRETE.
RMATION SHOWN ON THE DRAWINGS BEFORE PROCEEDING WITH THE WORK. THIS SHALL INCLUDE THE - STEEL = 77.0 KN/m3
3.2.7 UNLESS INDICATED OTHERWISE ALL BEAMS TERMINATING AT THE COLUMN SHALL HAVE TOP AND BOTTOM 7.9 ALL EQUIPMENT SHALL HAVE PROTECTION TO PREVENT LEAKAGE FROM EQUIPMENT ONTO THE
LOCATION AND DIMENSIONS OF GROOVES, REGLETS, SLEEVES, CURBS, OPENINGS, EMBEDDED OR BARS EXTENDING TO THE FARFACE OF THE COLUMN, TERMINATING IN A STANDARD 90° HOOK LENGTH CONCRETE SLABS. - SOIL = 19.0 KN/m3
ATTACHED ITEMS, ETC. REFER TO ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS. OF ANCHORAGE NOT LESS THAN 600MM. 7.10 SLAB REINFORCEMENT IS TO BE CHAIRED IN PLACE AT 900mm CENTERS PRIOR TO CONCRETE PLACEMENT. - WATER = 9.81 KN/m3
1.4 SECTIONS OR DETAILS. SPECIFIC NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER 3.2.8 SHOP DRAWINGS FOR BENDING AND CUTTING OF REINFORCEMENT SHALL BE SUBMITTED FOR APPROVAL AT NO TIME SHALL CONCRETE TRUCKS BE ALLOWED TO DRIVE ON CHAIRED REINFORCEMENT. 2. SUPER IMPOSED DEAD LOADS
GENERAL NOTES AND TYPICAL DETAILS. TO THE ENGINEER PRIOR TOFABRICATION. 7.11 NO PIPES, DUCTS OR CONDUITS SHALL BE PLACED IN THE FLOOR SLAB UNLESS SPECIFICALLY DETAILED IN - FLOOR FINISH & 50mm THK FLOOR TOPPING - 1.20 kPa
1.5 THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURES. 3.2.9 SPLICE LENGTH OF REINFORCING BARS SHALL BE AS SHOWN IN TABLE 4 OF DWG NO. 2790300-DWG-00-SE-8009. THESE PLANS OR UNLESS PRIOR WRITTEN APPROVAL IS GIVEN BY THE STRUCTURAL ENGINEER. - MEMBRANE WATER PROOFING (INCLUDING TOPPING) - 1.25 kPa
THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION UNLESS SO STATED. THE GENERAL CONTRACTOR 3.3 STRUCTURAL STEEL/ANCHOR BOLTS/BOLTS/WELDS & WELDMENTS: 7.12 SPECIAL EFFORT SHALL BE PROVIDED TO MAINTAIN A LOWER TEMPERATURE LESS THAN 27 DEGREE - CEILING WITH LIGHT FRAMING - 0.25 kPa
SHALL PROVIDE ALL NECESSARY MEASURES TO PROTECT THE STRUCTURES, ADJACENT PROPERTIES, CENTIGRADE ON THE CONCRETE DURING THE INITIAL POURING AND DURING THE FIRST 48 HOURS OF CURING. - EE/ME LIGHT UTILITIES - 0.25 kPa
WORKMEN AND OTHER PERSONS DURING ALL PHASES OF CONSTRUCTION. 3.3.1 ALL STRUCTURAL STEEL SHALL HAVE A MINIMUM YIELD STRENGTH, fy = 248 MPa (36 ksi) AND SHALL - MOVABLE PARTITION - 1.00 kPa
CONFORM TO ASTM A36 SPECIFICATIONS, UNLESS NOTED OTHERWISE. - 100MM THK PRE-CAST WALL - 2.40 kPa
1.6 THE GENERAL CONTRACTOR SHALL IMMEDIATELY NOTIFY THE CLIENT OWNER AND/OR THE STRUCTURAL 8.0 CONSTRUCTION JOINTS :
CONSULTANT OF ANY CONDITION WHICH IN HIS OPINION MIGHT ENDANGER THE STABILITY OF THE 3.3.2 ALL STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE AISC - 150MM THK PRE-CAST WALL - 3.60 kPa
STRUCTURES OR CAUSE DISTRESS IN THE STRUCTURES. SPECIFICATIONS (14TH EDITION) AND CODE OF STANDARD PRACTICE AS AMENDED TO DATE. 8.1 CONSTRUCTION JOINTS NOT INDICATED ON PLANS SHALL BE MADE SO AS TO LEAST IMPAIR THE - 100MM CHB WALL WITH PLASTER (25MM MAX) BOTH FACE - 2.46 kPa

www.beca.com
3.3.3 NO STEEL SHALL BE FABRICATED OR ERECTED UNTIL SHOP DRAWINGS HAVE BEEN APPROVED STRENGTH OF THE STRUCTURE AND SHALL BE SUBJECT TO APPROVAL OF THE STRUCTURAL CONSULTANT. - 150MM CHB WALL WITH PLASTER (25MM MAX) BOTH FACE - 3.45 kPa
1.7 CONSTRUCTION MATERIALS SHALL NOT BE STORED ON POURED FLOORS. IT IS THE GENERAL
CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THE SUB-CONTRACTORS ARE INFORMED AND DO NOT BY THE STRUCTURAL CONSULTANT. 8.2 STANDARD REQUIREMENTS AND LOCATIONS OF JOINTS, CONTROL JOINTS AND ISOLATION JOINTS MUST
VIOLATE THIS IMPORTANT REQUIREMENT. 3.3.4 ALL SHOP AND FIELD WELDING SHALL BE IN ACCORDANCE WITH AWS D.1.1-2010 AND PERFORMED REFER TO ACI 224.3R, ACI 302.1R,ACI 318, AND ACI 360R. 3. LIVE LOADS
1.8 THE GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY ERECTION BRACINGS AND SHORINGS FOR ALL BY QUALIFIED WELDERS. - DRIVEWAY AND RAMP - 4.80 kPa
3.3.5 UNLESS INDICATED OTHERWISE, WELDING ELECTRODES SHALL BE E70XX. MINIMUM THICKNESS 9.0 NOTES ON STRUCTURAL STEEL : - LOBBY, HALLWAY AND STAIR - 4.80 kPa
THE STRUCTURAL MEMBERS AS REQUIRED FOR STRUCTURE STABILITY DURING ALL PHASES OF
CONSTRUCTION. OF WELD SHALL BE AS FOLLOWS: - ADMIN/ENGINEERING OFFICE - 2.90 kPa
9.1 WORK POINT DIMENSION SHALL BE LOCATED WITHIN ±6mm OF LOCATION SHOWN IN DRAWING, ANY - GENSET/TRANSFORMERS - 12.0 kPa
1.9 THE GENERAL CONTRACTOR SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE PROPER ALIGNMENT OF 5mm CONTINUOUS FOR 10mm PLATE AND THINNER CHANGE IN STRUCTURAL GEOMETRY RESULTING IN MEMBER WHOSE LENGTH CHANGES BY MORE THAN 5 - ELECTRICAL/MECHANICAL ROOM - 6.00 kPa
THE STRUCTURES DURING AND AFTER THE INSTALLATION OF ALL STRUCTURAL AND FINISH MATERIALS. 6mm CONTINUOUS FOR 12mm PLATE PERCENT SHALL REQUIRE. APPROVAL BY THE STRUCTURAL CONSULTANT - RESTROOM - 2.40 kPa
1.10 STANDARD DETAILS AND CONSTRUCTION NOTES ON DWG NO. ST0-02.01 TO ST0-02.08 AND ST0-01.01 APPLY 8mm CONTINUOUS FOR 16mm PLATE 9.2 ALL DIMENSIONS IN THE PLANS SHALL BE VERIFIED BY THE FABRICATOR IN THE FIELD IN COORDINATION - ROOF DECK - 4.80 kPa
TO ALL PARTS OF THE WORKS UNLESS OTHERWISE SHOWN ON THE DRAWING. 10mm CONTINUOUS FOR 20mm PLATE AND THICKER WITHIN THE GENERAL CONTRACTOR. - FUNCTION/CONFERENCE ROOM - 4.80 kPa
1.11 THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL OTHER RELEVANT DRAWINGS 3.3.6 UNLESS OTHERWISE INDICATED ALL CARBON STEEL BOLTS AND STUDS SHALL CONFORM TO 9.3 ALL CONNECTION DETAILS SHOWN ARE CONCEPTUAL ONLY ALL CONNECTION DETAILS ARE
AND SPECIFICATIONS AND WITH SUCH WRITTEN INSTRUCTIONS AS MAY BE ISSUED DURING THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 4. LATERAL LOADS (NSCP 2015)
COURSE OF THE CONTRACT. ASTM A307 SPECIFICATION.
3.3.7 STRUCTURAL BOLT FOR MEMBER CONNECTIONS SHALL BE HEAT-TREATED STEEL STRUCTURAL BOLTS 9.4 MATERIAL OR WORKMANSHIP NOT ON REASONABLE CONFORMANCE WITH PROVISIONS OF THIS - WIND LOAD
1.12 WORKMANSHIP AND MATERIALS ARE TO BE IN ACCORDANCE WITH THE RELEVANT CODES OF PRACTICE SPECIFICATION MAY BE REJECTED AT ANY TIME DURING THE PROGRESS OF WORK. DESIGN CODE: = NSCP 2015/ ASCE7-10
AND THE LOCAL STATUTORY AUTHORITIES' REGULATIONS INCLUDING ALL AMENDMENTS, EXCEPT WHERE CONFIRMING TO ASTM A325 AND ASTM A490.
9.5 ALL STRUCTURAL STEEL MEMBERS SHALL BE APPLIED WITH PRIMER PAINT OR ANY OCCUPANCY CATEGORY (I-V): = IV

ORIGINAL IN COLOUR
VARIED BY THE CONTRACT DOCUMENTS. 3.3.8 ALL BUTT WELDS SHALL BE FULL PENETRATION CONTINUOUS USING E70XX ELECTRODES. EQUIVALENT BRAND (2 COATS). BASIC WIND SPEED, V: = 270 kph
1.13 SUBSTITUTIONS MUST BE APPROVED BY THE EMPLOYERS REPRESENTATIVE . 3.3.9 WELD TESTING SHALL BE AS FOLLOWS: VELOCITY PRESSURE, q: 2
= 0.613 Kz Kzt KdV
9.6 APPLY FIRE PROOFING MATERIAL ON ALL EXPOSED STRUCTURAL MEMBERS CONNECTED
1.14 ANY ARCHITECTURAL ITEMS THAT REQUIRES STRUCTURAL DETAILS SHALL BE BROUGHT TO THE - BUTT WELDS TEST 100% OF WELDS USING ULTRASONIC TESTING, SELECTED AT RANDOM. TO CONCRETE STRUCTURES. EXPOSURE CATEGORY: =C
STRUCTURAL DESIGNER'S ATTENTION, OTHERWISE IT WILL BE ASSUMED THAT COSTING HAD BEEN - FILLET WELDS TEST 5% WELDS USING MAGNETIC PARTICLE TESTING, SELECTED AT RANDOM. 9.7 SUBMIT SHOP DRAWING FOR REVIEW AND APPROVAL PRIOR TO FABRICATION WORK. FABRICATION MUST DESIGN WIND PRESSURE, P: P = qGCp - qi (GCpi)
CONSIDERED BY THE CONTRACTOR. - VISUAL INSPECTION OF ALL WELD PREPARATIONS PRIOR TO WELDING. NOT START UNLESS SHOP DRAWING HAVE BEEN APPROVED. - EARTHQUAKE LOAD
- VISUAL INSPECTION OF ALL WELDS AFTER WELDING. 9.8 ALL STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC SPECIFICATION SEISMIC CODE: = NSCP 2015
2.0 FOUNDATIONS : 4TH EDITION FOR DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL BUILDING. SEISMIC ZONE: = ZONE 4, Z = 0.4
3.3.10 ALL WELDERS SHALL BE PREQUALIFIED PERFORM PRE-QUALIFICATION TEST. SOIL PROFILE TYPE: = SD
2.1 FOUNDATION SUPPORTS DESIGN WAS BASED ON THE ALLOWABLE SOIL BEARING CAPACITY OF 125 KPa 9.9 ALL STRUCTURAL STEEL SHAPES, PIPES, ANGLE, PLATES AND RODS SHALL CONFORM TO ASTM A36
3.4 COLD FORMED STRUCTURAL STEEL: STANDARD SPECIFICATION FOR CARBON STRUCTURAL STEEL (LATEST REVISION). BUILDING BASE: = BASEMENT LEVEL
ON ENGINEERED FILLED MATERIAL AT SUB-GRADE LEVEL UNLESS NOTED OTHERWISE. CONFIRMATION SEISMIC SOURCE PROXIMITY: = >9 km FROM FAULT LINE
OF ACTUAL SOIL BEARING CAPACITY SHALL BE DONE PRIOR TO CONSTRUCTION OF FOUNDATION, 3.4.1 ALL COLD FORMED STEEL SHALL CONFORM TO THE LATEST EDITION OF THE AISI-2007 SPECIFICATIONS 9.10 STRUCTURAL BOLTS FOR MEMBER CONNECTIONS SHALL BE HEAT-TREATED STEEL STRUCTURAL BOLTS
FOR THE DESIGN OF COLD STEEL STRUCTURAL MEMBERS. CONFIRMING TO ASTM A325 AND ASTM A490, BEARING TYPE CONNECTION WITH TRENDS INCLUDED IN THE SEISMIC SOURCE TYPE: = TYPE BETWEEN A & B
INCREASE IN. FOUNDATION SIZE SHALL BE DONE WHEN ACTUAL SOIL BEARING CAPACITY, CONFIRMED (AS PER GEOTECHNICAL ENGINEER'S RECOMMENDATION)
DURING EXCAVATION, WARRANTS REVISION OF FOUNDATION SIZES. 3.4.2 STEEL SHEET ZINC COATED (GALVANIZED) OR ZINC IRON ALLOY COATED (GALVANNEATED) BY THE HOT SHEAR PLANE UNLESS OTHERWISE, THE MINIMUM NUMBER OF BOLTS PER CONNECTION IS TWO (2).
2.2 WHERE LOOSE/SOFT MATERIAL IS ENCOUNTERED AT DEPTH OF FOOTING/FOUNDATION INDICATED WHICH
DIP PROCESS SHALL CONFORM TO ASTM A653. 9.11 BOLTED CONNECTION FOR BEAM/ PURLINS SHALL BE DESIGNED TO SUPPORT HALF OF THE TOTAL DESIGN BASE SHEAR FOR STATIC FORCE PROCEDURE:
fy = 450 MPa FOR PURLINS AND GIRTS UNIFORM LOAD CAPACITY AS GIVEN BY THE AISC MANUAL OF STEEL CONSTRUCTION (14TH EDITION).
DOES NOT MEET THE SOIL BEARING CAPACITY NOTED ABOVE, CONTRACTOR TO EXCAVATE TO FIRM LAYER 2.5 Ca I W
AND REPLACE LOOSE/SOFT MATERIALS UNDERNEATH THE FOOTING WITHIN THE FOOTING AREA WITH 3.4.3 ALL REPLACEABLE CHANNELS SHALL BE EQUAL OR WITH EQUIVALENT SECTION APPROVED 9.12 WELDED CONNECTIONS AT END OF TENSION OR COMPRESSION MEMBER SHALL BE DESIGNED TO DEVELOP V = CvI WD D
BY THE ENGINEER BEFORE INSTALLATION. RT R
MASS CONCRETE. THE CAPACITY OF THE SECTION.
3.4.4 ROOF GALVANIZED DECK SHALL BE 24 GAUGE WITH NO.10 SCREWS U.O.N. 0.11 Ca I W
2.3 ALL FOUNDATIONS SHALL REST ON 75MM THICK GRAVEL OR 50mm THK BLINDING CONCRETE, 9.13 COMPRESSION MEMBERS OR PLATES TRANSMITTING COMPRESSION FORCES TO BEARING PLATES SHALL D
f'c = 10.5 MPa (1500 psi). 3.4.5 ALL MACHINE BOLTS SHALL COMPLY WITH ASTM A307. BE MILLED FOR FULL BEARING. 0.8 ZNv I W
2.4 BACKFILL SHALL BE PLACED IN 200mm LAYERS AND EACH LAYER SHALL BE COMPACTED TO 95% MAXIMUM 3.4.6 ALL SHEET METAL SCREWS SHALL BE NO.14 GALVANIZED LAG SCREWS WITH STEEL WASHER AND 9.14 WELDING PROCEDURES AND MATERIALS SHALL BE IN ACCORDANCE WITH AWS D1.1 (LATEST REVISIONS) R D
DRY DENSITY BEFORE SUBSEQUENT LAYERS ARE TO BE LAID. NEOPRENE, SELF-DRILLED OR COMMON, OF 50mm OR SIMILAR. "STRUCTURAL WELDING CODE" WELDING ELECTRODE SHALL BE E70xx. WHERE:
2.5 GENERAL CONTRACTOR TO PROVIDE FOR DE-WATERING OF EXCAVATION FROM EITHER SURFACE WATER, 3.4.7 ALL THE WALL METAL TRACKS SHALL BE 16 GAUGE MINIMUM U.O.N. 9.15 FOR ALL STRUCTURAL MEMBERS (BEAMS, COLUMNS, PLATES, ETC.) THAT ARE REQUIRED AND SPECIFIED IN V = TOTAL DESIGN LATERAL FORCE OR SHEAR AT THE BASE
GROUND WATER OR SEEPAGE. 3.4.8 ALL BLOCKING SHALL BE WITH LIGHT STEEL STUD OF MIN. WIDTH OF 38mm WITH 14mm LIP AND WITH A MAX. SOME STRUCTURAL DETAILS THAT NEED TO BE ANCHORED TO THE ADJACENT MASONRY WALL, THE GAP Z = SEISMIC ZONE FACTOR
SPACING OF 1.20M O.C. BETWEEN THEM VERTICALLY. PROVIDE DOUBLE STUD IN ALL DOOR JAMBS, BETWEEN THE MEMBER AND THE WALL (IF IT EXIST), SHALL BE FILLED WITH NON-EXPANSIVE CONCRETE.
2.6 GENERAL CONTRACTOR SHALL PROVIDE FOR DESIGN AND INSTALLATION OF CRIBBING, SHEATING AND I = IMPORTANCE FACTOR
SHORING REQUIRED TO SAFELY RETAIN THE EARTH BANKS. BORDERS AND WALL CORNERS.
10.0 MASONRY : =1.0
2.7 EXCAVATION AND COMPACTING IF REQUIRED, SHALL BE APPROVED BY THE GOVERNING AGENCY AND THE 3.4.9 ALL WELDING OF MATERIALS WITH THICKNESS LESS THAN 5mm SHALL BE MADE IN ACCORDANCE WITH THE T = C t (hn) 34 ELASTIC FUNDAMENTAL PERIOD OF VIBRATION OF THE
FOUNDATION ENGINEER PRIOR TO PLACING THE CONCRETE AND REINFORCING. FOUNDATION ENGINEER AWS D-1.3. WELDERS AND WELDING PROCEDURES SHALL BE QUALIFIED AS SPECIFIED IN AWS D-1.3. 10.1 CONCRETE BLOCK MASONRY UNITS SHALL COMPLY WITH THE FOLLOWING. STRUCTURE, IN SECONDS, IN THE DIRECTION UNDER CONSIDERATION.
TO SUBMIT LETTER OF COMPLIANCE TO EMPLOYER. a. LOAD BEARING CONCRETE MASONRY UNITS: Ct = NUMERICAL COEFFICIENT FOR STRUCTURE
4.0 NOTES ON CONCRETE SLAB : ASTM C90, GRADE N-I OR N-II, MADE WITH NORMAL WEIGHT AGGREGATES AND WITH MINIMUM - 0.0731 FOR REINFORCED CONCRETE MOMENT RESISTING FRAMES.
2.8 FOOTINGS SHALL BE PLACED AND ESTIMATED ACCORDING TO DEPTHS SHOWN ON DRAWINGS. SHOULD COMPRESSIVE STRENGTH OF f'c = 7 MPa (1000 psi) AT 28 DAYS. hn = THE HEIGHT OF THE STRUCTURE
SOIL ENCOUNTERED AT THESE DEPTHS NOT BE APPROVED BY THE FOUNDATION ENGINEER, FOOTING 4.1 ALL SLAB REINFORCEMENTS SHALL BE 30mm CLEAR FROM BOTTOM OF SLAB. b. NON-LOAD BEARING CONCRETE MASONRY UNITS: Ca = 0.44 Na , SEISMIC COEFFICIENT FOR STRUCTURE
ELEVATION WILL BE ALTERED AS REQUIRED. 4.2 LENGTH OF BAR CUT-OFF SHALL BE SPECIFIED AS NOTED IN SLAB SCHEDULE. ASTM C129 MADE WITH NORMAL WEIGHT AGGREGATES AND WITH MINIMUM COMPRESSIVE STRENGTH OF Cv = 0.64 Nv , SEISMIC COEFFICIENT FOR STRUCTURE
2.9 FOOTING BACKFILL AND UTILITY TRENCH BACKFILL WITHIN THE BUILDING AREA SHALL BE MECHANICALLY 4.3 IF BARS ARE REINFORCED BOTHWAYS, BARS ALONG THE SHORT SPAN SHALL BE PLACED BELOW THOSE f'c = 4.9 MPa (700 psi) AT 28 DAYS. Na = 1.04
COMPACTED IN LAYERS, IN ACCORDANCE WITH SOIL REPORT. FLOODING WILL NOT BE PERMITTED. ALONG THE LONG SPAN CENTER AND OVER THE LONGER SPAN BARS NEAR THE SUPPORT. 10.2 MORTAR SHALL TYPE S AND SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 12.4 MPa WITHIN 28 Nv = 1.16
2.10 ALL ABANDONED FOOTING, UTILITIES, ETC., THAT INTERFERE WITH NEW CONSTRUCTION SHALL BE REMOVED. 4.4 TEMPERATURE BARS FOR SLAB SHALL BE GENERALLY PLACED NEAR THE FACE IN TENSION AND SHALL DAYS TO CONFORM TO ASTM C270 SPECIFICATION FOR MORTAR FOR UNIT MASONRY. R = NUMERICAL COEFFICIENT REPRESENTATIVE OF THE INHERENT
2.11 ALL EARTHWORK SHALL BE DONE IN ACCORDANCE WITH SOIL REPORT RECOMMENDATION. NOT BE LESS THAN 0.0018 BT. GROUT SHALL CONFORM TO MINIMUM COMPRESSIVE STRENGTH OF 14.0 MPA WITHIN 28 DAYS TO OVER STRENGTH AND GLOBAL DUCTILITY CAPACITY OF THE
4.5 UNLESS OTHERWISE NOTED IN THE PLANS, ALL BEDDED SLABS ARE TO BE REINFORCED WITH CONFORM TO ASTM C476 SPECIFICATION FOR GROUT OF MASONRY. LATERAL-FORCE RESISTING SYSTEM
3.0 MATERIALS : Ø10MM AT 250MM O.C. 10.3 ALL CELLS CONTAINING REINFORCING OR ANCHOR BOLTS SHALL BE GROUTED SOLID. WHEN WALLS ARE = A. FOR WAREHOUSE: ORDINARY STEEL MOMENT FRAMES: R = 3.5
4.6 PROVIDE EXTRA REINFORCEMENT FOR CORNER SLAB (2 ADJACENT DISCONTINUOUS EDGE SHOWN TO BE SOLID GROUTED, ALL CELLS SHALL BE FILLED WITH GROUT. WHEN WALL CANNOT BE LIGHT STEEL FRAMED BEARING WALL WITH TENSION ONLY BRACING: R = 2.8
3.1 CONCRETE COMPLETED IN ONE POUR OR WHEN CONCRETE SLAB IS TO BE CAST OVER WALL, STOP POUR 40mm B. FOR VAS MEZZANINE: SPECIAL STEEL MOMENT FRAMES: R= 8.0
AS SHOWN ON DWG NO. 2790300-DWG-00-SE-8005).
3.1.1 SRENGTH OF NORMAL WEIGHT CONCRETE VIBRATOR, MINIMUM 4,000 R.P.M., 20mm HEAD. SOLID GROUT ALL AREA BELOW GRADE. LIFTS SHALL NOT SPECIAL STEEL CONCENTRIC BRACED FRAMES: R= 6.0
-FOUNDATIONS f'c = 27.7 MPa (3000 psi) 5.0 NOTES ON CONCRETE BEAM : EXCEED 2400MM IN HEIGHT PROVIDE INSPECTION AND CLEAN OUT HOLES FOR GROUT LIFTS EXCEEDING C. FOR OFFICE / AMENITIES BUILDING: SPECIAL STEEL MOMENT FRAMES: R=8
-RETAINING WALLS f'c = 27.7 MPa (3000 psi) 1200MM IN HEIGHT. REMOVE OVERHANGING MORTAR, PROVIDE INSPECTION AND CLEAN OUT HOLES FOR D. FORKLIFT RECHARGE AND TRANSFORMER/SWITCHROOM/GENSET MASONRY SHEAR WALLS: R=4.5
5.1 UNLESS OTHERWISE NOTED IN PLANS OR SPECIFICATIONS, CAMBER ALL BEAMS AND GIRDERS AT LEAST GROUT LIFTS EXCEEDING 1200MM IN HEIGHT. REMOVE OVERHANGING MORTAR, DROPPINGS AND ALL E. GUARDHOUSE, MATERIALS RECYCLING FACILITY AND REJECTED GOODS STORAGE
TOF TO UNDERSIDE OF ROOF DECK LEVEL: 6MM FOR EVERY 4500MM OF SPAN EXCEPT CANTILEVERS FOR WHICH THE CAMBERS SHALL BE AS NOTED DEBRIS FROM CELLS TO BE GROUTED. ON ALL REQUIRED MASONRY ANCHORS, ADDITIONAL TO THE CELL ORDINARY MOMENT RESISTING FRAMES: R=3.5
-COLUMNS AND PEDESTAL f'c = 27.7 MPa (3000 psi) IN THE PLANS OR AS ORDERED BY THE STRUCTURAL CONSULTANT, BUT IN NO CASE LESS THAN 18MM WHERE THE ANCHOR OCCURS, AT LEAST ONE CELL ABOVE & ONE CELL BELOW SHALL BE GROUTED. ORDINARY CONCENTRICALLY BRACED FRAMES: R=3.2
-GIRDERS/BEAM/SLABS/STAIRS f'c = 27.7 MPa (3000 psi) FOR EVERY 3000mm OF FREE SPAN.
10.4 MORTAR JOINTS SHALL BE STRAIGHT, CLEAN AND UNIFORM IN THICKNESS, AND SHALL BE TOOLED AS WD = TOTAL SEISMIC DEAD LOAD
-LEAN CONCRETE f'c = 10.5 MPa (1500 psi) 5.2 IF THERE ARE TWO OR MORE LAYERS OF REINFORCING BARS, USE SEPARATORS OF SAME SIZE BUT NOT
LESS THAN 25MM BARS SPACED ABOUT 1.00M ON CENTER AND PLACED DIAGONALLY. IN NO CASE SHALL SHOWN ON PLANS (TOOL JOINTS TO INSIDE, IF NO SPECIAL TREATMENT SPECIFIED SEE DETAIL A ON THE
3.1.2 ALL CONCRETE SHALL BE DEPOSITED, VIBRATED AND CURED IN ACCORDANCE WITH ACI STANDARD 318-2014. SIDE). UNLESS OTHERWISE SPECIFIED OR DETAILED ON THE PLAN, HORIZONTAL AND VERTICAL MORTAR
3.1.3 MINIMUM CONCRETE COVER FOR REINFORCING BARS SHALL BE AS FOLLOWS: THERE BE LESS THAN TWO (2) SEPARATORS BETWEEN LAYERS OF BARS.
5.3 WHEN A BEAM CROSSES A GIRDER, REST BEAM BARS ON TOP OF GIRDER BARS. REINFORCING BARS SHALL JOINTS SHALL BE 10MM WITH FULL MORTAR COVERAGE ON THE FACE SHELL. VERTICAL HEAD HEAD JOINTS
A. FOOTINGS AND BOT. OF FOOTING TIE BEAMS = 75mm (CAST AGAINST EARTH) BE SYMMETRICAL ABOUT THE CENTER LINE WHENEVER POSSIBLE. UPPER LAYER SHALL BE PLACED SHALL BE BUTTERED WELL FOR A THICKNESS EQUAL TO THE FACE SHELL OF THE BLOCK AND THESE
B. SIDES OF FOOTING TIE BEAMS = 50mm (CAST AGAINST FORMS) DIRECTLY ABOVE THOSE IN THE BOTTOM LAYER. SPACING OF BARS IN LAYER SHALL NOT BE LESS THAN JOINTS SHALL BE SHOVED TIGHTLY SO THAT THE MORTAR BONDS WELL TO BOTH BLOCKS. IF IT IS
C. BEAMS AND COLUMNS = 40mm (TO STIRRUPS AND TIES) 0.025M NOR ONE BAR DIAMETER. NECESSARY TO MOVE A BLOCK SO AS TO OPEN A JOINT, THE BLOCK SHALL BE REMOVED FROM THE WALL,
D. SLABS AND WALLS = 30mm (CAST AGAINST FORMS, UNLESS NOTED OTHERWISE)5.4 GENERALLY, NO SPLICE SHALL BE PERMITTED ON BEAM AT POINT WHERE CRITICAL BENDING STRESSES CLEANED AND SET IN FRESH MORTAR.
OCCUR. WELDED SPLICES SHALL DEVELOP IN TENSION AT LEAST 125% OF THE SPECIFIED STRENGTH OF 10.5 REINFORCING SHALL BE AS SPECIFIED FOR CONCRETE WORK, EXCEPT LAPS SHALL BE 50 BAR
E. BOTTOM SLAB AND WALLS = 50mm (INSIDE SURFACE OF WATER RETAINING STRUCTURE) THE BAR, NOT MORE THAN 50% AT ANY ONE SECTION SHALL BEALLOWED TO BE SPLICED THEREIN. DIAMETERS OR 600mm MIN. U.O.N.
3.1.4 BEFORE CONCRETE IS POURED, CHECK WITH ALL TRADES TO ENSURE PROPER PLACEMENT OF ALL 5.5 FOR BAR TERMINATIONS OF TOP BARS AT SUPPORT AND MIDSPAN BARS, CUT-OFF ONLY TWO BARS AT 10.6 HORIZONTAL REINFORCING SHALL BE PLACED IN BOND BEAM UNITS ONLY. PROVIDE ONE BAR MAXIMUM IN
OPENINGS, SLEEVES, CURBS, CONDUITS, ETC. RELATIVE TO THE WORK. EVERY 0.3M INTERVAL (UNLESS REQUIRED IN SPECIFICATIONS, OR NOTED OTHERWISE.) EACH BLOCK EXCEPT AT SPLICES.
3.1.5 WHEN CONCRETE WILL BE EXPOSED TO EXTERNAL SOURCES OF CHLORIDES IN SERVICES, SUCH AS 10.7 VERTICAL BARS IN WALLS ARE TO BE PLACED IN CENTER OF WALL UNLESS OTHERWISE SHOWN.
DEICINGS, SALTS, BRACKISH WATER, SEAWATER OR SPRAY FROM THESE SOURCES, CONCRETE MUST BE 6.0 NOTES ON CONCRETE COLUMN : 10.8 C.M.U. WALL PATTERN SHALL BE COMMON BOND UNLESS OTHERWISE SPECIFIED.
PROPORTIONED TO SATISFY THE SPECIAL EXPOSURE REQUIREMENTS OF ACI STANDARD 318-2014. 6.1 CONFINEMENT TIES SHALL BE PROVIDED ON ALL COLUMNS AT BEAM COLUMN JOINTS UNLESS OTHERWISE 10.9 CONDUITS OR PIPES SHALL NOT OCCUR IN SAME CELL AS REINFORCED BARS UNLESS
3.1.6 MAXIMUM AMOUNT OF WATER AND ADMIXTURES SHALL BE 175 kg/cu.m. SHOWN IN PLAN. APPROVED BY ENGINEER.
3.2 REINFORCING BARS: 6.2 COLUMN TIES AND SPIRALS SHALL BE PROTECTED UNIFORMLY BY A COVERING OF CONCRETE 11.0 PENETRATIONS AND CAST-IN ITEMS :
3.2.1 ALL REINFORCING BARS SHALL BE DEFORMED AND CONFORM WITH ASTM A706 (PNS 49) WELDABLE, MONOLITHICALLY WITHIN THE CORE OF MINIMUM THICKNESS OF 40mm AND NOT LESS THAN 1 1/2 TIMES 11.1 IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO COORDINATE THE LOCATION OF ALL
WITH MINIMUN YIELD STRENGTH THE SIZE OF COARSE AGGREGATES. REQUIRED PENETRATIONS AND CAST-IN ITEMS IN THE CONCRETE INCLUDING BOLTS, BRACKETS,
fy = 414 MPa (60000 psi) FOR 16mm dia & LARGER STARTER BARS, POCKETS AND THE LIKE.
fy = 275 MPa (40000 psi) FOR 10mm dia & SMALLER 7.0 INTERIOR FLOOR SLAB : 11.2 WHERE ANY PENETRATIONS OR CAST-IN ITEMS DISPLACE THE REINFORCEMENT, THE ARRANGEMENT OF
3.2.2 ALL REINFORCING BARS SHALL BE CLEANED OF RUST, 7.1 ALL INTERIOR FLOOR SLABS SHALL BE AS INDICATED ON PLANS, OVER 95% COMPACTED BASE (CLASS II THE REINFORCEMENT SHALL BE APPROVED BY THE STRUCTURAL CONSULTANT. UNDER NO
GREASE OR OTHER MATERIALS WHICH TEND TO IMPAIR BOND. BASE WITH A MIN. DEPTH OF 450mm U.O.N.). SOIL ENGINEER IS TO VERIFY THAT THE FINISHED PAD IS CIRCUMSTANCES IS REINFORCEMENT TO BE DISPLACED INTO THE COVER ZONE.
PROPERLY COMPACTED AND IS TO SUBMIT WRITTEN VERIFICATION TO THE ENGINEER PRIOR TO SLAB 11.3 NO HOLES, CHASES OR EMBEDMENT OF PIPES OTHER THAN THOSE SHOWN ON THE STRUCTURAL
3.2.3 ALL REINFORCING BARS SHALL BE ACCURATELY AND SECURELY PLACED BEFORE POURING PLACEMENT. BACK FILL SOIL SHALL BE SANDY SOIL. DRAWINGS SHALL BE MADE WITHOUT THE APPROVAL OF THE STRUCTURAL CONSULTANT.
CONCRETE OR APPLYING MORTAR OR GROUT. 7.2 ALL THE WORK PHASES SHALL BE DONE UNDER A SPECIAL INSPECTOR SUPERVISION WITH A SLAB 11.4 SERVICE CONDUITS IN THE SLABS ARE TO BE PLACED IN THE MIDDLE THIRD OF THE SLAB.
3.2.4 LAPPED SPLICES SHALL BE STAGGERED WHERE POSSIBLE. QUALIFICATION. SUCH INSPECTOR SHALL BE PROVIDED BY THE OWNER. 11.5 TEMPLATES SHALL BE USED TO CORRECTLY LOCATE AND HOLD IN POSITION ALL CAST-IN BOLTS Client:
7.3 NO ADMIXTURE WILL BE ALLOWABLE IN CONCRETE SLABS. ALL THE CONCRETE MIXTURE DESIGNS WILL BE DURING PLACEMENT OF CONCRETE.
SUBMITTED TO THE STRUCTURAL ENGINEER FOR APPROVAL. ALL MIXTURE DESIGNS WILL HAVE A MINIMUM 11.6 ALL POST-INSTALLED REBARS/ANCHOR BOLTS TO THE STRUCTURAL ELEMENTS, i.e. COLUMNS, BEAMS, ORIGINAL DRAWING
OF 360 KG. OF CEMENT FOR EVERY CUBIC METER OF CONCRETE-APPLICABLE FOR CONCRETE TOPPINGS. FOUNDATIONS, SHEARWALLS, SHALL BE INSTALLED WITH HILTI HIT-RE 500-V3 STRUCTURAL EPOXY
7.4 APPLY CURING COMPOUND (TWO LAYERS MINIMUM APPLIED IN DIFFERENT DIRECTIONS) IMMEDIATELY OR APPROVED EQUAL.
AFTER THE SLAB IS FINISHED.
IN COLOUR PRECOnISc., Green Sun (formerly Solid House), 2285 Don Chino
Roces Avenue Extension, 1231 Makati City, Philippines
12.0 NON-STRUCTURAL ELEMENT ATTACHMENT :

Document No. 2790327-SE-0201.DWG


Project:
12.1 CONTRACTOR TO PROVIDE DESIGN AND DETAILS OF SUPPORTING ELEMENTS AND CONNECTION OF
FOR TENDER SOLID LF
Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. STANDARD DRAWINGS STRUCTURAL
0 ISSUED FOR TENDER EFG FTF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SHEET 1 OF 9 Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-0201 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

150mm 150mm 150mm


CHB WALL CHB WALL CHB WALL 12.50mm
R.C. WALL
(MIN.)
REBAR
REBAR (REFER TO SCHEDULE) EXPANSION JOINT FILLER
(REFER TO SCHEDULE) BAR TO MATCH SLAB
REBAR W/ JOINT SEALANT
R.C. WALL REINFORCEMENT REINFORCING
SLAB REINFORCEMENTS SLAB REINFORCEMENTS (REFER TO SCHEDULE)
(SEE NOTES) SLAB REINFORCEMENTS
(REFER TO SCHEDULE) (REFER TO SCHEDULE) 200
(REFER TO SCHEDULE) 600
GROUND FLOOR SSL GROUND FLOOR SSL TOP OF SLAB ON GRADE

150 MIN.
VERIFY
(MAX.)

(MAX.)
1000

1000
Ø10-400 VERT. & Ø10-400 HOR.

VERIFY
FGL FGL FGL
VARIES

VARIES

VERIFY
DOWEL BARS TO MATCH SLAB 150mm THK SLAB
REINFORCEMENT ROUGHEN JOINT W/ Ø10-300 E.W. (UNLESS NOTED OTHERWISE)
TOP OF SLAB ON GRADE
600

600

600
250
SEE NOTES ON FOOTING SEE NOTES ON FOOTING SEE NOTES ON FOUNDATION

www.beca.com
250

250

t
Ø10-300 O.C. Ø10-400
3-Ø10mm 3-Ø10mm BOTTOM BARS
Ø10-300 O.C. Ø10-300 O.C. 3-Ø10 BOTTOM BARS
400 400 150 300 150 TOP MOST LAYER 3-Ø16mm CONT. BARS 200
TOP MOST LAYER 600
TOP MOST LAYER TOP MOST LAYER OF COMPACTED BASE Ø12-250 O.C.
OF COMPACTED BASE
OF COMPACTED BASE OF COMPACTED BASE WIDTH OF FOOTING TOP MOST LAYER
(SEE NOTES ON FOOTING) 400 OF COMPACTED BASE

CANTILEVER EXTERIOR INTERIOR

ORIGINAL IN COLOUR
1 2 3
NTS
TYPICAL CHB WALL FOOTING DETAILS NTS
TYPICAL R.C. WALL FOOTING DETAIL NTS
SECTION AT PIT DETAIL

NOTE : NOTE :
FOOTING MAY BE RETURNED TO ORIGINAL THE CONTRACTOR SHALL BE RESPONSIBLE FOR 7A SLEEVE 50mm LARGER
DEPTH BY PLACING LEAN CONCRETE ON TOP SHEATING OR OTHERWISE MAINTAINING THE THAN O.D. OF PIPES
OF LAYER OR SUITABLE MATERIAL. SIDES OF THE EXCAVATION FROM CAVE-INS
UNTIL ALL BACKFILL IS COMPLETED AS PER PIPE THRU FOOTING WALL
SPECIFICATION.
FOOTING DOWELS SHALL MATCH WALL
3000 MIN. TRENCH

LOWER FOOTING SO PIPES


REINFORCING IN GRADE, SIZE AND NUMBER

FOR PIPES IN THIS AREA


EXCAVATION

CAN PASS THRU WALL


LOCATION OR DEPTH OF
FOOTING AS PER PLAN
2d MIN. HORIZONTAL LAP GROUND LEVEL
SPLICE
REINFORCING SHALL MATCH

250
LONGITUDINAL FOOTING BARS
BACKFILL PER SPECS.
IN SIZE AND NUMBER
300 MIN.

FOOTING

900
d

LAYER OF UNSUITABLE SLEEVE


MATERIAL 450
1:8 MAX. SLOPE 2
450 MAX.

1
H

150
TOP MOST LAYER LAYER OF SUITABLE MATERIAL BOTTOM OF TRENCH EXCAVATION SHALL
OF COMPACTED BASE FGL
NOT EXTEND BELOW THIS LINE 1
HORIZONTAL LAP 900 MIN.
2
SPLICE SECTION - 7A
WHERE SHOWN ON PLAN INDICATES THE Ø OF SLEEVE
POINT OF STEPPED FOOTING OVER EXCAVATE AND LOWER FOOTING TO COMPACTED FILL EQ. EQ.
ELEV. OF SUITABLE MATERIAL AS DIRECTED SOIL DEPOSIT NOTE :
BY C.M. 450 MIN. FOR PIPE LOCATED 900mm OR LESS BELOW
FTG. PROVIDE SLEEVE AND CONCRETE AS
SHOWN; MORE THAN 900mm COMPACT
BACKFILL OVER PIPE TO 90% AS APPROVED
BY SOIL ENGINEER OR USE STEPPED FOOTING
BELOW PIPE.

4 5 6 7
NTS
STEPPED FOOTING DETAIL NTS
FOOTING CONSTRUCTION AT UNSUITABLE MATERIAL DETAIL NTS
EXCAVATIONS PARALLEL TO FOOTING NTS
EXCAVATIONS PERPENDICULAR TO FOOTING
NOTES : NOTE :
SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR THE FOLLOWING: * FOR TRENCH LOCATION AND SIZE, SEE
DEPRESSION, D

1. LOCATION AND DIMENSION OF PADS AND BASES. PLANS AND/ OR APPLICABLE ARCH'L, MECH'L
6t OR 2. DETAILS OF STRUCTURAL SLABS, SUPPORTS AND ISOLATORS. AND ELEC'L DWGS.
450 (MIN.) 3. LOCATION AND SIZE OF BOLTS.
PROVIDE LAP WHERE
DEPRESSION >100

CONCRETE INERTIA BLOCK


150 MIN.
W/ Ø10-300 O.C. U.N.O. PROVIDE ANGLE BAR (6mm THK)
VERIFY BASE WITH 10mm DOWELS @ 400mm O.C.
PROVIDE 90° HOOK REQUIREMENTS ANCHOR BOLT ISOLATOR PAD
WHERE D EXCEEDS 50mm FOR GRATING AND GRATING SUPPORT
TRENCH* 600mm HOOKS TYP.
(VERIFY)

DETAILS, SEE ARCH'L DETAILS


MIN.
100

SLAB REINFORCEMENTS GROUND BEAM REINFORCEMENTS


(REFER TO SCHEDULE) (REFER TO SCHEDULE)

(SEE PLAN)
150
(VERIFY)

TRENCH*
Ø10 AS SHOWN

t
250 MIN.
250
h<600

t
LEAN CONCRETE
100
75 CLEAR

Ø10-400 O.C. 50mm THK, f'c=10.5 MPa


Ø10-300 E.W.

70mm CLEAR
12mm THK COMPRESSIBLE TYPICAL U.N.O.
200
MATERIAL ALL AROUND
(MIN.)
VERIFY BASE TYPE - A TYPE - B 11
REQUIREMENTS
NTS
GROUND BEAM DETAIL
Client:

ORIGINAL DRAWING
IN COLOUR PRECOnISc., Green Sun (formerly Solid House), 2285 Don Chino
Roces Avenue Extension, 1231 Makati City, Philippines

Document No. 2790327-SE-0202.DWG


Project:

FOR TENDER SOLID LF


8 9 10 Solid Integrated Logistics Facility
NTS
DEPRESSED ON-GRADE SLAB & EDGE DETAILS NTS
CONCRETE BASE AND SLAB FOR EQUIPMENT NTS
TYPICAL ON-GRADE TRENCH DETAIL CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. STANDARD DRAWINGS STRUCTURAL
0 ISSUED FOR TENDER EFG FTF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SHEET 2 OF 9 Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-0202 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

BENTONITE
WATERSTOP
BENTONITE BENTONITE
RETAINING WALL
SSL WATERSTOP WATERSTOP

BENTONITE
BASEMENT WALL
SSL WATERSTOP

WALL
SSL
LIFTWELL SUMP SSL

www.beca.com
WATER TANK
LEAN CONCRETE
50mm THICK,
f'c=10.5 MPa (1500 psi)

LEAN CONCRETE
LEAN CONCRETE 50mm THICK,
50mm THICK, f'c=10.5 MPa (1500 psi)
f'c=10.5 MPa (1500 psi)

ORIGINAL IN COLOUR
1 2 3 4
NTS
TYPICAL CORNER AT WATER TANK LIFT PIT/ SUMP DETAIL NTS
TYPICAL BASEMENT SLAB CONSTRUCTION JOINT DETAIL NTS
TYP. CORNER AT WATER TANK & EXTERNAL WALL DETAIL NTS
TYPICAL CORNER DETAIL

NOTES : NOTES : NOTES : NOTES :


1. ALL REINFORCEMENTS ARE Ø10-200 O.C. 1. ALL REINFORCEMENTS ARE Ø10-200 O.C. 1. ALL REINFORCEMENTS ARE Ø10-200 O.C. 1. ALL REINFORCEMENTS ARE Ø10-200 O.C.
2. ALL DIMENSIONS ARE TO BE VERIFIED. 2. ALL DIMENSIONS ARE TO BE VERIFIED. 2. ALL DIMENSIONS ARE TO BE VERIFIED. 2. ALL DIMENSIONS ARE TO BE VERIFIED.
PROVIDE ANGLE
3. a = VERIFY 3. a = VERIFY 3. a = VERIFY 3. a = VERIFY
BAR (6mm THK)
WITH 10mm MIN. 75x75 RECESS FOR PROVIDE ANGLE
PROVIDE ANGLE
MIN. 75x75 RECESS DOWELS @ MANHOLE COVER BAR (6mm THK)
BAR (6mm THK)
FOR MANHOLE 400mm O.C. (ACTUAL DIMENSION TO SUIT WITH 10mm
WITH 10mm
COVER (ACTUAL DOWELS @ MANHOLE COVER DETAILS). DOWELS @
DIMENSION TO SUIT 400mm O.C. 400mm O.C.
GROUND FLOOR LEVEL GROUND FLOOR LEVEL
MANHOLE COVER t VERIFY t
a VERIFY a
a

DETAILS).
PAVING LEVEL
GROUND FLOOR LEVEL
a

Ø20-500 DOWEL BARS

a
TO BE PROVIDED AT ALL
TRENCH JUNCTIONS

a
VOID
a
a

WITH SLAB, PLINTH AND


GROUND BEAMS
a

a
t

a a a

t CHANNEL WIDTH t

5 6 7 8
NTS
TYPICAL CONCRETE CABLE WAY DETAIL NTS
TYPICAL SAND TRAP DETAIL NTS
TYPICAL TRENCH DETAIL NTS
TYPICAL MANHOLE DETAIL

NOTE :
1. WHERE h<cl, DETAIL SHALL BE SUBJECT TO
THIS APPROVAL OF THE STRUCTURAL ENGINEER.
h = HEIGHT OF BEAM
d = DEPRESSION Ld
2 SETS OF STIRRUPS
TOP BARS
SUMP PIT
DIMENSIONS TOP BARS
25mm CONC. COVER

(REFER TO PLANS)

d
SUMP PIT DIMENSIONS ARCHITECTURAL

h
(REFER TO PLANS) TYP. REINF. NOT FINISH Ld
2-Ø10 @ 300 E.W. 300 150 R.C. WALL 300 150 Ld
150 (MIN.) 150 (MIN.) SHOWN PREMOLDED JOINT (REFER TO
(MIN.) VERIFY Ld

h
VERIFY OR COLUMN MATERIAL
ALL AROUND ALL AROUND ARCHITECTURAL

d
PLANS)
BOTTOM BARS
150
150

1-Ø10 NOSING BAR BOTTOM BARS


2-Ø10 @ WITH Ø10-300 O.C.
2 SETS OF h d
2200 (MAX.)

VARIES

300 (MIN.) STAIR TIES (TYP.) PROVIDE


VARIES

Ø12-300 O.C. E.F. STIRRUPS


VOID
POLYETHYLENE
Ø12-300 O.C. E.F.

(VE
9A SHEETING VAPOR

RIF
TOP OF FTG. BARRIER
POUR TO

Y)
150

400

TOP OF SLAB ON GRADE


(VERIFY)

FOOTING Ø10-300 O.C.


BELOW IF ONE Ø10-300 O.C.
(MIN.)

R.C. WALL
150

EXIST & IS OR COLUMN TOP MOST LAYER


WITHIN 150mm OF COMPACTED 12
BASE NTS
TYPICAL BEAM CHANGE OF SOFFIT DETAIL
PLAN SECTION - 9A TYPE - A TYPE - B Client:

ORIGINAL DRAWING
IN COLOUR PRECOnISc., Green Sun (formerly Solid House), 2285 Don Chino
Roces Avenue Extension, 1231 Makati City, Philippines

Document No. 2790327-SE-0203.DWG


Project:

FOR TENDER SOLID LF


9 10 11 Solid Integrated Logistics Facility
NTS
TYPICAL SUMP PIT DETAIL NTS
TYPICAL OPEN CANAL DETAILS NTS
TYPICAL STAIR ON-GRADE DETAIL CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. STANDARD DRAWINGS STRUCTURAL
0 ISSUED FOR TENDER EFG FTF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SHEET 3 OF 9 Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-0203 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

TOOLED JOINT 2-EQUAL SPACES


NOTES : dsc = LARGER OF HORIZONTAL LAP
1. LOCATIONS OF CONSTRUCTION JOINT, IF REQUIRED,
ARE SUBJECT TO THE APPROVAL OF THE ENGINEER.
t
4 OR 25mm CONTINUE 50% OF TRANSVERSE NOTES ON CONSTRUCTION /
REINFORCEMENT THRU JOINT
2. PROVIDE BENTOSEAL/ WATERSTOP @ JOINTS FOR 3mm MAXIMUM FOR CONTRACTION JOINT IN SLAB & BEAMS
WATER RETAINING STRUCTURES. SEMI-RIGID JOINT
3. SEE NOTES ON CONSTRUCTION JOINTS. SEALANT 6mm FOR 1.0 GENERAL NOTES :
ELASTOMERIC SEALANT
1.1 SLAB SECTIONS BE PLACED IN AREAS AS SQUARE AS POSSIBLE AND THAT LENGTH TO WIDTH RATIOS SHOULD NOT
ROUGHEN EXISTING CONCRETE PROVIDE 0.20mm THK EXCEED 1.50 TO 1.0 RATIOS:
SURFACES THAT WILL BE JOINED POLYETHYLENE 1:1 A = B LENGTH OR WIDTH
WITH FRESH CONCRETE TO AN SHEETING
AMPLITUDE OF APPROXIMATELY 6mm. 7575 1:1.5 A = 1.5 B OR
CONTINUOUS BARS TYPICAL REINFORCEMENT VAPOR BARRIER
30 BAR DIA. 30 BAR DIA. 30 BAR DIA. 30 BAR DIA. B = 1.5 A
FOR TOP & BOTTOM
75 75 TOP MOST LAYER 1.2 WHEN USING SHRINKAGE COMPENSATING CEMENT, SLAB LOCATED INSIDE ENCLOSED STRUCTURES, ON WHERE TEMPERATURE
25mm OF COMPACTED BASE CHANGES ARE SMALL, MAXIMUM AREA OF POURING IS 16,000 ft 2 1500m 2.
CONTINUOUS BARS 40
1.3 AND IN AREAS WHERE TEMPERATURE CHANGES ARE LARGER, OR WHERE SLABS ARE NOT UNDER ENCLOSED STRUCTURES,
CONSTRUCTION JOINT MAXIMUM AREA OF POURING IS FROM 7000 ft2 TO 12000 ft2 (650m2 TO 1110m ).2
t\3

D\3

t\3
t\3

REBAR 2.0 SLAB ON GRADE :

THK
D\3

t\3
D
SAW-CUT WITHIN 4-8 HOURS AFTER
t\3

POURING PLACING CONCRETE 2.1 CONTRACTION JOINTS SHALL BE PROVIDED AT 24 TO 36 TIMES THE SLAB THICKNESS IN BOTH DIRECTION OR

D\3

t\3

www.beca.com
Ø10x1000 LONG MAXIMUM AT EVERY 6m.
@ 300 O.C. 40 1-Ø16 E.W. FOR MEMBERS 2.2 RE-ENTRANT CORNER SHOULD BE AVOIDED, IN CASE CANNOT BE AVOIDED, RE-ENTRANT CORNER SHOULD BE
WHERE JOINT IS AT POINT OF UP TO 175mm WIDE 2-Ø20 E.W. FOR MEMBERS CONTINUOUS BARS PROVIDED WITH REINFORCEMENT TO LIMIT THE CRACKING AT THIS LOCATION.
Ø25-200

t
STRESS, PROVIDE SHEAR RODS 200 TO 350mm WIDE 4-Ø20 E.W. FOR MEMBERS FOR TOP & BOTTOM 150mm THK BASE COURSE COMPACTED TO 2.3 REFER TO DETAIL 3, 5, 6 & 7 FOR LOCATION OF ISOLATION & CONTRACTION JOINT.
WITH ENGINEERS APPROVAL 375 TO 600 WIDE Ø20-200 E.W. FOR ROUGHEN EXISTING CONCRETE SURFACES AT LEAST 95% MDD 2.4 CONSTRUCTION JOINT CAN BE LOCATED SAME AS FOR CONTRACTION JOINT.
MEMBERS WIDER THAN 600 THAT WILL BE JOINED WITH FRESH SUBGRADE COMPACTED TO
ROUGHEN EXISTING CONCRETE CONCRETE AT LEAST 95% MDD 3.0 SUSPENDED SLABS AND BEAMS :
SURFACES THAT WILL BE TO AN AMPLITUDE OF APPROXIMATELY 6mm.
JOINED WITH FRESH CONCRETE PROVIDE 0.20mm THK POLYETHYLENE 3.1 CONSTRUCTION JOINTS IN SUSPENDED SLAB SHALL BE LOCATED WITHIN THE MIDDLE HALF OF THE SLAB CLEAR
TYPICAL REINFORCEMENT SHEETING VAPOR BARRIER SPAN OR AT LEAST AT SLAB 1/3 SPAN, WHERE CONCRETE POURING OPERATIONS ENDED FOR THE DAY.
TO AN AMPLITUDE OF APPROXIMATELY 6mm. 3.2 CONSTRUCTION JOINT IN BEAMS SHALL BE NEAR THE 1/3 OF SPAN, AT LEAST 300mm CLEAR FROM LAP SPLICE.
SLAB BEAM MAT/FOOTING
3.3 WHEN A BEAM INTERSECTS A GIRDER, CONSTRUCTION JOINT IN THE GIRDER SHALL BE OFFSET A DISTANCE
SAW JOINT EQUAL TO TWICE (2X) THE WIDTH OF THE INCIDENT BEAM.
(WHERE CONTINUOUS POUR IS USED) NOTES :
1. SEE NOTES ON CONSTRUCTION JOINT.
2. REINFORCEMENT TO BE AT MID DEPTH OF SLAB. 4.0 STANDARD REFERENCES FOR CONSTRUCTION JOINTS :
4.1 ACI 224.3R, ACI 302.1R, ACI 360R, ACI 318.

ORIGINAL IN COLOUR
1 2
NTS
TYPICAL SLAB, BEAM, & MAT/FOOTING CONSTRUCTION JOINT DETAILS NTS
SLAB-ON-GRADE JOINT DETAILS

NOTE : NOTE :
12.5mm d = 2x WIDTH OF THE INCIDENT BEAM
PROVIDE BENTOSEAL/ WATERSTOP @ JOINTS.
(MIN.)

ELASTOMERIC JOINT SEALANT Y Y Y Y Y


EQUIPMENT FOUNDATION L L L L
SLAB ON GRADE
ISOLATION JOINT ISOLATION JOINT L/3 RANGE OF C.J. L/3 RANGE OF C.J. L/3 L/3 RANGE OF C.J.
(TYPICAL) (TYPICAL) L/3 L/3 L/3
d d

X
(M 00
.)
3
IN

PREFORMED JOINT FILLER


90°

90°

INCIDENT

L
BEAM
CASE - 1 CASE - 2
CONTRACTION
JOINT (TYPICAL) 5
CONTRACTION OR
CONSTRUCTION JOINT NTS
ISOLATION JOINT AT EQUIPMENT PAD / FOUNDATION
(TYPICAL)

X
CONTRACTION JOINT (TYPICAL)

L/3

L/3
12.5mm
(MIN.)
PLAN

RANGE OF C.J.

d
ELASTOMERIC JOINT SEALANT

L/3

L/3
L
SLAB ON GRADE
3
NTS
ISOLATION JOINT AT COLUMNS / WALLS OF SLAB-ON-GRADE
WALL WITH SEPARATE FOUNDATION

L/3
X
NOTES : PREFORMED JOINT FILLER
1. THERE SHALL BE A MINIMUM OF 24 HOURS BETWEEN
POURS 1 AND 2.
2. SEE NOTES ON CONSTRUCTION JOINT.

CONSTRUCTION JOINT

L
GRID (SEE NOTES ON
CONSTRUCTION JOINT (C.J.) 6 CONSTRUCTION JOINTS)
A A A A
NTS
ISOLATION JOINT AT WALL
GRID
B

X
B
B

ELASTOMERIC OF SEMI-RIGID
JOINT SEALANT
B

VARIES SLAB ON GRADE


1 2 1 2 1
B
B

8
POUR SEQUENCE CONTRACTION JOINT PREFORMED JOINT FILLER
NTS
SUSPENDED SLABS & BEAMS CONSTRUCTION JOINT LOCATION PATTERN
Client:

ORIGINAL DRAWING
IN COLOUR PRECOnISc., Green Sun (formerly Solid House), 2285 Don Chino
Roces Avenue Extension, 1231 Makati City, Philippines

Document No. 2790327-SE-0204.DWG


Project:

FOR TENDER SOLID LF


4 7 Solid Integrated Logistics Facility
NTS
SLAB-ON-GRADE POUR PATTERN DETAILS NTS
ISOLATION JOINT AT COLUMN CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. STANDARD DRAWINGS STRUCTURAL
0 ISSUED FOR TENDER EFG FTF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SHEET 4 OF 9 Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-0204 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTE :
NOT APPLICABLE TO SHEARWALL. ALL
OPENINGS BEYOND 1200mm SHALL BE FOR
NOTES : APPROVAL OF THE STRUCTURAL ENGINEER.

40 D
1. ALL WALLS SHALL BE REINFORCED ACCORDING TO THE FOLLOWING SCHEDULE
SCHEDULE OF CONCRETE WALL UNLESS OTHERWISE SHOWN IN THE DRAWINGS. REINFORCING BARS SHALL ALTERNATE BARS SPLICE
HAVE 25mm MIN. CLEAR CONCRETE COVER FROM FACE OF WALL EXCEPT FOR IN 40D SPLICE LENGTH 3A
WALLS IN CONTACT WITH THE GROUND WHERE A MINIMUM OF 62.50mm WITH CENTER TO CENTER DIAGONAL BARS

1500mm
R.C. WALL REINFORCEMENT VERTICAL SHALL BE PROVIDED. AND FOR FORMED SURFACES EXPOSED TO WEATHER MIDDLE OF SPLICE
t (mm) REMARKS SECTION
HORIZONTAL VERTICAL WHERE THE MINIMUM SHALL BE 50mm CLEAR. 1500mm.
2. CARRY VERTICAL BARS AT LEAST 600mm ABOVE FLOOR LEVEL TO PROVIDE
100mm Ø10-300 O.C. Ø10-300 O.C. VERTICAL BARS @ CENTER FOR SPLICES. ELSEWHERE STOP AT 50mm BELOW THE TOP OF THE SLAB OR

40 D
HORIZONTAL BARS STAGGERED OUTSIDE SOLID BOND WHERE THE WALLS ENDS. HORIZONTAL AND VERTICAL BARS
130mm Ø10-300 O.C. Ø10-225 O.C. SHALL BE SPLICED BY LAPPING A DISTANCE EQUAL TO FORTY (40) BAR

40 db
150mm Ø10-300 O.C. Ø10-200 O.C. DIAMETER AND WIRED SECURELY WITH NO.16 G.I. WHERE PROVIDED THAT THE
ADJACENT BARS ARE STAGGERED AT LEAST 1500mm O.C.
180mm Ø10-250 O.C. Ø10-150 O.C. 3. U.N.O. ALL OPENINGS IN WALLS SHALL BE REINFORCED AS FOLLOWS.
4. DIAGONAL REINFORCEMENTS SHALL BE 2-Ø16 AT 75mm O.C. PLACED AT
200mm Ø10-250 O.C. Ø10-150 O.C. HORIZONTAL BARS EACH FACE MID-DEPTH OF SLAB EACH CORNER OF THE OPENINGS. SEE NOTE ON
5. ALL WALLS SPANNING OPENINGS SHALL HAVE VERTICAL REINFORCEMENTS BENT CONCRETE WALL

www.beca.com
230mm Ø10-200 O.C. Ø10-125 O.C. TO A-U- FORM LIKE STIRRUPS AND SPACED ACCORDING TO SCHEDULE U.N.O.
6. SEE TYPICAL DETAIL OF CONCRETE WALL OPENING.
250mm Ø10-200 O.C. Ø12-175 O.C.
THK WALL REINFORCEMENTS
280mm Ø12-250 O.C. Ø12-150 O.C.
250mm 40
250mm : 2-Ø20 E.F. db
300mm Ø12-250 O.C. Ø12-150 O.C. 40
db
175mm 40 db

600mm
350mm Ø12-200 O.C. Ø12-125 O.C. 150mm : 2-Ø16 E.F.

400mm Ø16-300 O.C. Ø16-200 O.C. 125mm


100mm : 2-Ø12 E.F. FLOOR LEVEL
ALL VERTICAL SECTION - 3A
BARS SPLICE
ABOVE FLOOR ELEVATION

ORIGINAL IN COLOUR
1 2 3
NTS
SCHEDULE OF CONCRETE WALL NTS
ELEV. OF CONCRETE WALL SHOWING VERT. SPLICE DETAIL NTS
TYPICAL CONCRETE WALL OPENING DETAIL

NOTES : NOTE :
NOTE : 1. ALL TOP AND BOTTOM SLAB BARS INTERRUPTED BY FOR OTHER PIPE PENETRATIONS GREATER
THIS DETAIL DOES NOT APPLY TO SHEARWALLS OPENING SHALL BE REPLACED BY ADDITIONAL THAN THE MAXIMUM REQUIRES SLAB
AND SLAB ON METAL DECK. REINFORCEMENTS EQUAL TO THAT INTERRUPTED. PLACE OPENINGS, TYPICAL SLAB OPENING DETAIL
HALF OF THE ADDITIONAL REINFORCEMENT PLUS ONE ON SHOULD BE USED. 100mm 100mm COMPRESSIBLE MATERIALS
(MIN. TYP.) (MIN. TYP.) CHB "t"
EACH SIDE OF OPENING AND EXTEND SAME LENGTH AS IN (REFER TO ARCH'L. FOR
BAR DEVELOPMENT LENGTH, Ld SEE ARCHITECTURAL & FIRE RATING)
OPENING MECHANICAL PLANS FOR SLAB OPENING LOCATION. CMU WALL
2. OMIT TRIMMER BARS WHERE OPENING IS FRAMED BY BEAMS.
CONCRETE SLAB 3. BOXED OUT OPENINGS, RECESSES AND PIPE SLEEVE 2-Ø16 @ 75 75mm PIPE SLEEVE
OR WALL BEYOND CLUSTERS SHALL BE TREATED AS FRAMED SLAB OPENING. (TYP.) Ø10 DOWELS CONCRETE FILLER
DIAGONALS AT
4. MAXIMUM DIMENSION FOR EACH SIDE OF OPENING SHALL BE WELDED (CAST-IN-PLACE
75mm 75mm MID-DEPTH OF Ø10 DOWELS
1000mm OPENINGS BEYOND THE SAID DIMENSION ARE TO PIPE SLEEVE

75mm
50mm CLEAR SLAB AT EACH OR PRE-MOLDED)
TYPICAL TYPICAL SUBJECT TO THE APPROVAL OF THE ENGINEER. 40 WELDED
TYPICAL CORNER db TO PIPESLEEVE
5. NOT APPLICABLE TO SHEARWALL AND SLAB ON METAL DECK.
PIPE

(MAX.)

(MAX.)
250

250
40 CONCRETE FILLER
(T db (CAST-IN-PLACE
YP
.) OR PRE-MOLDED) PIPE

12mm GAP MIN.


MASTIC SEALANT

(TYP.)
40db
PIPE SLEEVE 2-Ø10 PIPE EACH SIDE
SEE SLAB SCHEDULE 75mm
(G.I. SCHED 40) CONCRETE FILLER
SEE SLAB SCHEDULE
(CAST-IN-PLACE
STANDARD 90 1-Ø16 TOP & BOT. BARS FOR SINGLE OR PRE-MOLDED)
BARS ADDED FOR OPENING (ADD 1/2 DEGREE HOOK 40mm CLEAR (TYP) (TYP. ALL AROUND)
VOID
THE NUMBER OF BARS INTERRUPTED PIPE CAST-IN
BY OPENING PLUS ONE EACH SIDE SLAB REBARS NOT CUT,
75mm MAX.
AT 75mm O.C.- ADDED BAR SIZE TO BENT ONLY TO GIVE
PIPE
MATCH INTERRUPTED BAR SIZE) WAY TO PIPE SLEEVE ELEVATION SECTION
EXTEND BARS UP PIPE SLEEVE
TO BEAM SUPPORT (G.I. SCHED 40)

40db FOR MUTIPLE PIPES CAST-IN


NOTE (1) AT (TYP.)
75mm SPACING

4 5 6 7
NTS
TYPICAL SECTION OF SLAB OPENING NTS
TYPICAL SLAB OPENING DETAIL NTS
PIPE SLEEVE THRU SLAB DETAIL NTS
PIPE SLEEVE THRU CHB DETAIL

SLAB REINFORCEMENTS
NOTE :
* DEPTH AS PER DRAINAGE LAYOUT DWG.
(REFER TO SCHEDULE) EDGE BEAM
10-Ø20 @ 150 O.C.
L
BOTTOM BARS
H\3

2H LIMIT LOCATION OF PIPE SLEEVE 2H


(SEE NOTE 4)

(NO PIPE SLEEVE SHALL (NO PIPE SLEEVE SHALL DISCONTINUOUS EDGE BENT DOWN (TYP.)
2 - EXTRA STIRRUPS
BE ALLOWED WITHIN BE ALLOWED WITHIN ON CORNER COLUMN
H\3

H\5

EACHSIDE OF SLEEVE EDGE BEAM


H

THIS ZONE, TYP.) THIS ZONE, TYP.)


SCHED. 40 G.I.
SCHED. 40 G.I.
H/2

PIPE SLEEVE ZONE OF PENETRATION


PIPE SLEEVE
H\3

EDGE BEAM
8A BEAM REINFORCEMENTS
4-Ø12 @ 400 O.C.
(REFER TO SCHEDULE)
BOT. BARS
H\3

TOP BARS TOP BARS B

10-Ø20 1200mm
H\3
H

EDGE BEAM SHORTEST @ 150 O.C.


SECTION - 8A TOP BARS
(SEE NOTE 4)
H\3

BOTTOM BARS 500 500 BOTTOM BARS


H/5

FACE OF SUPPORT (TYP.) (TYP.) NOTES :


2 EXTRA BARS 1. SEEK STRUCT'L. ENGINEER'S APPROVAL FOR PIPE 6-Ø12 @ 150 O.C.
E.F. (DIAGONAL) SLEEVES W/ DIAMETERS BIGGER THAN THE MAXIMUM BY 1200mm LONG
ALLOWABLE PENETRATION ZONE 4D (MIN.) STIPULATED. TOP BARS
2. PIPE SLEEVES SHALL BE LOCATED WITHIN TENSION
ZONES OF BEAMS.
10
3. NO PIPE SLEEVE SHALL BE ALLOWED AT TWICE THE
BEAM DEPTH (2H) FROM THE SUPPORT. NTS
PLAN OF SLAB AT TWO ADJACENT DISC. EDGE DETAIL
4. PIPE SLEEVE MAX DIAMETER IS: (LEAST GOVERNS)
Client:
A. 1/5 OF BEAM DEPTH
B. STANDARD PIPE SLEEVE DETAIL FOR 150mm
DIAMETER PIPE ON 600mm BEAM IS 175mm. ORIGINAL DRAWING
IN COLOUR PRECOnISc., Green Sun (formerly Solid House), 2285 Don Chino
Roces Avenue Extension, 1231 Makati City, Philippines

Document No. 2790327-SE-0205.DWG


Project:

FOR TENDER SOLID LF


8 9 Solid Integrated Logistics Facility
NTS
PIPE SLEEVE THRU BEAM DETAIL NTS
TYPICAL REINFORCEMENT AT SLAB CORNER CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. STANDARD DRAWINGS STRUCTURAL
0 ISSUED FOR TENDER EFG FTF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SHEET 5 OF 9 Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-0205 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

LINTEL BEAM REINF. SYM.

SCHEDULE OF MASONRY WORKS


LINTEL BEAM
MASONRY

(TYP.)
CHB WALL

600
HEIGHT OF WALL Hw EXCEEDING 3000mm
t (mm) SSL
HORIZONTAL BARS VERTICAL BARS Ø10-400 O.C.
100 Ø10-600 O.C. Ø10-400 O.C. EXPANSION JOINT DOWEL BARS (TYP.)
VERTICAL SIDES OF
150 Ø10-600 O.C. Ø10-400 O.C. DOORS AND WINDOWS
MORTAR FILLER W/
LINTEL COLUMN
200 Ø10-600 O.C. Ø10-400 O.C. 1-Ø10 HOR.
BAR (TYPICAL) 100
NOTES : WINDOW DOOR

3000
1. REFER TO ARCHITECTURAL PLANS FOR EVERY LOCATION OF ALL CMU AND R.C. NON
STRUCTURAL WALLS. EXPANSION JOINT Ø10-400 O.C.
2. REFER THICKNESS OF FINISHED TO ARCHITECTURAL PLANS. VERT. BARS (TYP.)

www.beca.com
3. 20mm THICK GAP SHALL BE PROVIDED IN BETWEEN WALLS AND COLUMNS, WALLS AND
BEAMS, WALLS AND BEAM/SLAB SOFFIT.
4. SEALANT SHALL BE PROVIDED FOR ALL EXTERNAL WALL (CMU OR R.C.) FOR INTERNAL
WALLS, SEALANT NEED BE PROVIDED.
5. STRUCTURAL R.C. WALLS (l.a WATER etc.) SHALL NOT BE PROVIDED WITH 20mm THK MORTAR FILLER
GAPS ALL AROUND. W/ 1-Ø10
6. STRUCTURAL GAPS SHALL IN NO CASE BE COVERED W/ PLASTER. SSL
HOR. BAR (TYPICAL)
7. ALL CELLS SHALL BE FILLED WITH MORTAR.

(TYP.)
Ø10 HOR. BARS

300
EXPANSION JOINT
@ EVERY 3 LAYERS
OF CHB

SSL
200

ORIGINAL IN COLOUR
1 2 3 4
NTS
SCHEDULE OF MASONRY WORKS NTS
TYPICAL MASONRY ELEVATION NTS
TYP. ELEV. OF MASONRY SHOWING VERT. SPLICE & DOWELS NTS
WINDOW/ DOOR OPENING AT MASONRY WALL

NOTE : B
UNLESS OTHERWISE NOTED IN THE PLAN, PROVIDE
FRAMING STIFFENER COLUMNS & STIFFENER
SCHEDULE OF LINTELS U.N.O.
WALL "t"
BEAMS NOT MORE THAN 3.0M APART.
CLEAR SPAN LINTEL SIZE REINFORCEMENT
Ø10-200 O.C.
STIRRUPS
WIDTH WIDTH (B) DEPTH (H) A B STIRRUPS
>2500 SAME CHB THICKNESS 200 2-Ø12 2-Ø12 Ø10-125
250

STIFFENER BEAM STIRRUPS


>2500 <4500 SAME CHB THICKNESS 300 2-Ø16 2-Ø16 Ø10-175 A
2-Ø10mm CLEAR SPAN
MAIN BARS >4500 <6500 200 400 2-Ø20 2-Ø16 Ø10-200
1-Ø10
NOTES :
STIFFENER BEAM 1. BEARING ON BLOCK WALL ON EITHER SIDE OF OPENING SHALL BE AT LEAST EQUAL TO THE OVERALL DEPTH OF THE LINTEL. 200 200
STIFFENER 2. OVERALL LINTEL DEPTHS COULD BE INCREASED TO SUIT BLOCK WORKING COURSING (NON LOAD BEARING WALLS).
h<3000

BEAMS 3. FOR BLOCK WALLS WITH HEIGHT MORE THAN 3.0M, PROVIDE LINTEL BEAM WITH THE SAME SCHEDULE AS IN SPAN > 4500.
300 B

200
B 40db
Ø10-200 O.C. 200
FFL

SAME AS IN WALL THICKNESS


TIES
STIFFENER WALL OR COLUMN
h<3000

VARIES
H

COLUMNS
150-200

HORIZONTAL BARS (100 TO 150)


STIFFENER
COLUMN CONTRACTOR TO ENSURE
CMU WALL REBARS CORRECT STARTER BARS
STIRRUPS
WALL 4-Ø12 ARE CAST INTO CONCRETE
L<3000 L<3000 A CONCRETE FACE
BASE ELEMENTS AS NECESSARY.
MAIN BARS CLEAR SPAN
2-Ø10 VERTICAL BARS W/
Ø10 TIES @ 150mm O.C.
ELEVATION STIFFENER COLUMN
CMU
THICKNESS 200

5 6 7
NTS
TYPICAL STIFFENER BEAMS & COLUMNS NTS
TYPICAL STANDARD LINTEL BEAMS NTS
TYPICAL ZOCALLO DETAIL

CMU WALL

POLYURETHANE
ELASTIC SEALANT
BOTTOM OF
POLYURETHANE OR APPROVED EQUAL CONCRETE SLAB/BEAM
BACKING ROD (NON-COMBUSTIBLE) 2-Ø16 EXTRA
POLYURETHANE VERT. BARS

20
ADDITIONAL
FLOOR LEVEL ELASTIC SEALANT
Ø10-400 O.C.
OR APPROVED EQUAL CMU VERT. REINF. POLYURETHANE
(NON COMBUSTIBLE) CMU WALL ELASTIC SEALANT
POLYURETHANE (SEE SCHED. OF REINF.)
BACKING ROD OR APPROVED EQUAL
20 600 CMU WALL (NON-COMBUSTIBLE)
PVC PIPE SLEEVE CMU VERT. REINF.
(SEE SCHED. OF REINF.)
R.C. COLUMN CMU WALL
OR WALL
BEAM SOFFIT
20

POLYURETHANE
2-Ø16 EXTRA BACKING ROD
CMU WALL VERT. BARS
ADDITIONAL
CMU VERT. REINF. Ø10-400 O.C.
CMU VERT. REINF. (SEE SCHED. OF REINF.) CMU VERT. REINF.
(SEE SCHED. OF REINF.)
(SEE SCHED. OF REINF.)
1-Ø16 EXTRA POLYURETHANE ELASTIC
VERT. BARS SEALANT
OR APPROVED EQUAL
11
NTS
WALL SUPPORT AT BOTTOM OF SLAB
Client:
POLYURETHANE
BACKING ROD
ORIGINAL DRAWING
IN COLOUR PRECOnISc., Green Sun (formerly Solid House), 2285 Don Chino
Roces Avenue Extension, 1231 Makati City, Philippines

Document No. 2790327-SE-0206.DWG


Project:

FOR TENDER SOLID LF


8 9 10 Solid Integrated Logistics Facility
NTS
WALL SUPPORT AT BOTTOM OF SLAB/ BEAM NTS
WALL REINFORCEMENT AT R.C. COLUMN WALL NTS
WALL REINFORCEMENT AT CORNER CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. STANDARD DRAWINGS STRUCTURAL
0 ISSUED FOR TENDER EFG FTF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SHEET 6 OF 9 Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-0206 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTE :
UNLESS OTHERWISE NOTED ON PLANS.

200 SLAB REINFORCEMENTS


(REFER TO SCHEDULE) 700
100
SLAB REINFORCEMENTS SLAB REINFORCEMENTS 100 500 100
150
(REFER TO SCHEDULE) (REFER TO SCHEDULE) (MAX)
TOP OF PARAPET

t
8-Ø12 AS SHOWN

600 < H < 1000


R.C. WALL

(MAX)
400
Ø12-200 O.C. E.F
t

t
CHB WALL
Ø10-400 O.C.

350 < H < 1000


Ø16-400 O.C.

H < 600
Ø12-250 O.C.

BEAM DEPTH
1-Ø10 O.C. E.F. VERT. BARS HOR. BARS
375

Ø16-300 O.C. E.F

H < 1000

900
100
Ø16-400 O.C.
Ø10-400 O.C. VERT. BARS
Ø16-300 O.C. E.W. HOR. BARS

BEAM DEPTH
CHB WALL

375
DECK SLAB

400
DECK SLAB VOID

BEAM DEPTH
375
REINFORCEMENTS
REINFORCEMENTS
(REFER TO SCHEDULE)
(REFER TO SCHEDULE)

www.beca.com
BEAM WIDTH Ø10-300 O.C.
FLOOR SLAB REINFORCEMENTS
EDGE BEAM (REFER TO SCHEDULE)
EDGE BEAM
REINFORCEMENTS EDGE BEAM
BEAM WIDTH REINFORCEMENTS
BEAM WIDTH (REFER TO SCHEDULE) REINFORCEMENTS PROVIDE DOWEL
(REFER TO SCHEDULE)
(REFER TO SCHEDULE)

CASE 1 CASE 2 CASE 3


CASE-1 CASE-2 CASE-3

ORIGINAL IN COLOUR
1 2
NTS
TYPICAL R.C. WALL/ BEAM SUPPORTING ELEVATED FLOOR SLAB DETAILS NTS
TYPICAL PARAPET DETAILS

NOTE :
WHERE H > D FOR BEAMS, DETAIL SHALL BE ld
SUBJECT TO THE APPROVAL OF THE ENGINEER.

t<H<250
t
FLOOR SLAB
REINFORCEMENTS VERIFY ARCH'L.

t
(REFER TO SCHEDULE)
t
NON-STRUCTURAL

ld
TOPPING Ø10-250 O.C. DOWELS
SLAB REINFORCEMENTS
Ø10-300 O.C. R.C. SLAB
(REFER TO SCHEDULE)
LONGITUDINAL BARS (AS SCHEDULED) SSL
EDGE BEAM
REINFORCEMENTS 40 BAR DIA. OR TENSION CASE-2

VERIFY ARCH'L.
(REFER TO SCHEDULE) TOP BAR SPLICE

H<t OR D (NOTE 1)
(GREATER OR NOTE 1).
GIRDER/ BEAM
300 REINFORCEMENTS
Ø12-300 O.C. (REFER TO SCHEDULE)
H <1000

VERT. BARS
D (FOR BEAM)
t (FOR SLAB)

STANDARD HOOK
45°

R.C. BEAM

250 < H < 600

250
(AS SCHEDULED)

150mm
D (FOR BEAM)
1-Ø36 HOISTING REBAR

(MIN.)
t (FOR SLAB)
t

STANDARD HOOK
Ø12-300 O.C.
HOR. BARS
2t (FOR SLAB)

150mm

(MIN.)
100 NOTE : D (FOR BEAM)
H > 50mm

t
30 BAR DIA.
300
(MIN.)

CASE-1 CASE-3

3 4 5 6
NTS
TYPICAL DROP WALL DETAIL NTS
TYPICAL BEAM OR SLAB CHANGE OF SOFFIT DETAILS NTS
TYPICAL NON-STRUCTURAL TOPPING DETAIL NTS
BEAM HOISTING HOOK DETAIL

Client:

ORIGINAL DRAWING
IN COLOUR PRECOnISc., Green Sun (formerly Solid House), 2285 Don Chino
Roces Avenue Extension, 1231 Makati City, Philippines

Document No. 2790327-SE-0207.DWG


Project:

FOR TENDER SOLID LF


Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. STANDARD DRAWINGS STRUCTURAL
0 ISSUED FOR TENDER EFG FTF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SHEET 7 OF 9 Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-0207 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES :
1. FOR CURB SIZES AND LOCATION SEE ARCHITECTURAL
DRAWINGS. 75
2. PROVIDE INSERTS AS REQUIRED BY ARCHITECTURAL
AND MECHANICAL DRAWINGS.
TYP.
200x100x7x10mm
SEPARATOR BEAM @
2000mm O.C.
4-Ø16 A325 OR AS SPECIFIED BY
ANCHOR BOLTS ELEVATOR SUPPLIER

250 SEPARATOR BEAMS


CURB WIDTH AS REQUIRED
GREATER OR EQUAL TO 200

30
CURB WIDTH AS REQUIRED REFER TO ARCHITECTURAL DRAWINGS

300
150
100 MIN. 4- 16 A325 ANCHOR
Ø10 CONTINUOUS Ø10 CONTINUOUS 25mm CLEAR 200 MIN. 200 MIN. 25mm CLEAR BOLTS
175 MAX.
HORIZONTAL BAR HORIZONTAL BAR
2L-75x75x6.35mm STIFFENER COLUMN

75mm MIN.
75mm MIN.
75mm MIN.

300
SHEAR CONNECTOR OR BEAM/R.C. WALL

150 MAX.

150 MAX.

150 MAX.
2L-75x75x6.35mm

100 MIN.

100 MIN.

100 MIN.

www.beca.com
"H"

"H"

"H"
SHEAR CONNECTOR
TOP OF SLAB TOP OF SLAB TOP OF SLAB 250x300x12mm THK
12 STEEL PLATE
30 30

30
VERIFY

Ø10-300 O.C. SLAB REINFORCEMENTS Ø10-300 O.C. SLAB REINFORCEMENTS Ø10-250 O.C. Ø10-250 O.C. SLAB REINFORCEMENTS
DOWEL (REFER TO SCHEDULE) DOWEL (REFER TO SCHEDULE) DOWEL BOTHWAYS (REFER TO SCHEDULE)

ELEVATION
CURB - TYPE 1 CURB - TYPE 2 ISLAND AND MECHANICAL PADS

SECTION

ORIGINAL IN COLOUR
1 2
TYPICAL DETAILS FOR CONC. CURBS, PADS AND ISLANDS/ RAISED ISOLATED FLOOR AREA CONNECTION OF SEPARATOR BEAM/ GUIDE RAIL DETAIL

NOTE :
CONNECTION DETAIL TO BE DESIGNED BY
PRE-CAST DESIGNER.

12mm WELDED
STUDS
Ø12-300 O.C.
TOP BARS
L-50x50x10mm 180 TYP. NEOPRENE JACK-UP MOUNT
600mm
180 (MAX.) Ø10-150 BOTH WAYS
PRE-CAST CONCRETE FLOOR FINISH/ WATER PROOFING

VERIFY ARCHITECTURAL
POLYETHYLENE SHEET

75
(REFER TO ARCH'L FOR DETAILS)

100
CONCRETE PAD (3,000psi)

200
R.C. WALL

250
PARTITION WALL

150
40 ISOLATION BOARD
CLE 0
AR 4-Ø10mm

SLAB
2-Ø12mm

t
Ø16 PLAIN Ø10-300 O.C.
12mm THK PLATE STAINLESS STEEL STIRRUPS

12mm WELDED STUDS BASEMENT SLAB

NOTE :
SPACING AND NEOPRENE JACK-UP MOUNTS
SECTION ISOMETRIC VIEW TO BE AS PER GENSET SUPPLIER
RECOMMENDATION.

3 4 5 6
PRE-CAST ANCHORAGE DETAIL LADDER RUNG DETAIL TYP. COUNTERTOP REINFORCEMENT DETAIL FLOATING FLOOR DETAIL FOR GENSET

GRID MAX = 15000

TYPICAL Ø10 TIES TOP & BOTTOM BARS 1000 FROM CONGESTED CONDUIT
@ 400 O.C. B.W. AS PER SLAB SCHEDULE

VERIFY
MASS
SLAB t

CONCRETE
373

SLOPE

THICKNESS
LONGITUDINAL & TRANSVERSE BARS 373

SLAB
SAME AS PER SLAB LONGITUDINAL
150
SECTION - A 25mm CHAMFER
1-Ø10 CONT. BAR
SLAB
REINFORCEMENTS

SLAB THK 150


Ø10-250 O.C. (REFER TO SCHEDULE)

1000 FROM CONGESTED CONDUIT


A
Ld TYPICAL Ø10 TIES TOP & BOTTOM BARS
CONDUITS
@ 400 O.C. B.W. AS PER SLAB SCHEDULE
SLAB t
373

LONGITUDINAL BARS
BOTTOM BARS SAME
AS PER SLAB BOTTOM
SAME AS PER SLAB 9
BAR SCHEDULE
LONGITUDINAL BAR
SCHEDULE
TYPICAL MONOLITHIC TOPPING DETAIL
Client:

ORIGINAL DRAWING
IN COLOUR PRECOnISc., Green Sun (formerly Solid House), 2285 Don Chino
Roces Avenue Extension, 1231 Makati City, Philippines

Document No. 2790327-SE-0208.DWG


Project:

FOR TENDER SOLID LF


7 8 Solid Integrated Logistics Facility
TYPICAL SLAB THICKENING DUE TO CONDUIT SPACING < 125mm TYPICAL WHEEL STOP DETAIL CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. STANDARD DRAWINGS STRUCTURAL
0 ISSUED FOR TENDER EFG FTF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SHEET 8 OF 9 Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-0208 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

BEND DIAMETER

"
"O

"
"O
TABLE 1:
REBAR TABLE 2:

"
"0
BAR (d) D
TYPE DEVELOPMENT LENGTH OF DEFORMED BARS IN
6
DEVELOPMENT LENGTH FOR STANDARD HOOKS, Ldh

D
1
6d
TIE OR Ø16 AND SMALLER 4d COMPRESSION, Ldc
STIRRUP LARGER THAN Ø16 6d DIAMETER f'c, MPa DIAMETER f'c, MPa
A B (mm) (mm)
MAX. OFFSET BEND 21.0 27.60 35.00 - - - - - 21.00 27.60 35.00 - - - - -
Ø25 AND SMALLER 6d fy = 275 MPa fy = 275 MPa
TYPICAL COLUMN TIES PRINCIPAL
ALTERNATE POSITION OF SUCCESSIVE TIE SPLICES TYPICAL Ø28 - Ø36 8d 10 200 200 200 - - - - - 10 150 150 150 - - - - -
REINFORCING

OK IN.
BAR HIGHER THAN Ø36 10d 12 200 200 200 - - - - - 12 180 160 150 - - - - -

HO 5 M
TI R 7
DIAMETER DIAMETER

O
NOTE : f'c, MPa f'c, MPa

D
6d
E
ALL BENDS SHALL BE MADE COLD. (mm) (mm)
fy = 414 MPa 21.00 27.60 35.00 - - - - - fy = 414 MPa 21.00 27.60 35.00 - - - - -
NOTE :
"

"
"O

"O

www.beca.com
FOR SIZE AND SPACING OF ALL TIES AND 10 220 200 200 - - - - - 10 230 200 180 - - - - -
6d

STIRRUPS, REFER TO SCHEDULE AND/OR


12 270 230 220 - - - - - 12 280 240 220 - - - - -

d
DETAILS TYPICAL. 6d
DIMENSION "O" : 16 350 310 290 - - - - - 16 370 320 290 - - - - -

D
D
FOR Ø10 = 95mm

12d
FOR Ø12 = 100mm 20 440 380 360 - - - - - 20 460 400 360 - - - - -

D
C D FOR Ø16 = 130mm 4d OR
25 550 480 450 - - - - - 25 570 500 450 - - - - -
65mm MIN.
28 620 530 500 - - - - - 28 640 560 500 - - - - -
BEAM STIRRUPS 90° HOOK 180° HOOK TIE OR STIRRUP 32 700 610 570 - - - - - 32 730 640 570 - - - - -
ALTERNATE POSITION OF 135' AND 90' BENDS TYPICAL
36 790 690 650 - - - - - 36 820 710 640 - - - - -

40 880 760 720 - - - - - 40 920 790 710 - - - - -

ORIGINAL IN COLOUR
1 2
TYPICAL COLUMN TIES AND BEAM STIRRUPS BAR END BEND
NOTE :
TABLE 3:
APPLICABLE FOR H LESS THAN 6.80M ONLY. NOTE : DEVELOPMENT LENGTH OF DEFORMED BARS IN TENSION, Ld
* FOR TRENCH LOCATION AND SIZE, SEE
PLANS AND/ OR APPLICABLE ARCH'L, MECH'L
LOCATION OF HAUNCHED AND ELEC'L DWGS. f'c, MPa f'c, MPa
DIAMETER 21.00 27.60 DIAMETER 35.00 -
(mm) (mm)
fy = 414 MPa TOP BARS OTHER BARS TOP BARS OTHER BARS fy = 414 MPa TOP BARS OTHER BARS TOP BARS OTHER BARS
Cat. 1 Cat. 2 Cat. 1 Cat. 2 Cat. 1 Cat. 2 Cat. 1 Cat. 2 Cat. 1 Cat. 2 Cat. 1 Cat. 2 Cat. 1 Cat. 2 Cat. 1 Cat. 2
H

PROVIDE ANGLE BAR WITH SAME


HEIGHT AS STEEL GRATING (6mm THK) 10 570 850 440 660 500 740 400 570 10 450 660 340 510 - - - -
WITH 10mm DOWELS @ 400mm O.C.
12 680 1020 530 790 600 890 460 680 12 530 790 410 610 - - - -
150mm DIAMETER B 3981* TRENCH* Ld 16 910 1360 700 1050 800 1180 600 910 16 710 1050 550 810 - - - -

(SEE SCHEDULE)
HALF DIAMETER 20 1130 1700 870 1310 1000 1480 760 1130 20 890 1310 680 1010 - - - -

TRENCH*

t
25 1750 2690 1340 2070 1520 2340 1170 1800 25 1350 2090 1050 1610 - - - -

28 1950 3020 1500 2320 1700 2610 1310 2010 28 1510 2350 1180 1810 - - - -
LOCATION OF HAUNCHED
H

t
32 2230 3450 1720 2650 1940 3000 1500 2300 32 1730 2680 1340 2060 - - - -

36 2510 3880 1930 2980 2200 3360 1680 2590 36 1950 3010 1500 2310 - - - -
2t 2t
40 2790 4310 2150 3320 2450 3730 1880 2880 40 2160 3350 1680 2570 - - - -
H

BEAM/GIRDER
(SEE SCHEDULE)

150mm DIAMETER
TABLE 4:
FULL DIAMETER LAP SPLICE OF DEFORMED BARS IN TENSION
f'c, MPa f'c, MPa
3 TYPICAL HAUNCHED DETAIL FOR BEAM DEPTH 4
TYPICAL TRENCH DETAILS FOR SUSPENDED SLAB DIAMETER 21.00 27.60 DIAMETER 35.00 -
MORE THAN 600mm FOR HALLWAYS (mm) (mm)
fy = 414 MPa TOP BARS OTHER BARS TOP BARS OTHER BARS fy = 414 MPa TOP BARS OTHER BARS TOP BARS OTHER BARS
Cat. 1 Cat. 2 Cat. 1 Cat. 2 Cat. 1 Cat. 2 Cat. 1 Cat. 2 Cat. 1 Cat. 2 Cat. 1 Cat. 2 Cat. 1 Cat. 2 Cat. 1 Cat. 2
10 750 1110 580 860 650 970 520 750 10 590 860 450 670 - - - -

12 890 1330 690 1030 780 1160 600 890 12 690 1030 540 800 - - - -

16 1190 1770 910 1370 1040 1540 790 1190 16 930 1370 720 1060 - - - -

20 1470 2210 1140 1710 1300 1930 990 1470 20 1160 1710 890 1320 - - - -

25 2280 3500 1750 2700 1980 3050 1530 2350 25 1760 2720 1370 2100 - - - -

28 2540 3930 1950 3020 2210 3400 1710 2670 28 1970 3060 1540 2360 - - - -

32 2900 4490 2240 3450 2530 3900 1960 2990 32 2250 3490 1750 2680 - - - -

36 3270 5050 2510 3880 2860 4370 2190 3370 36 2540 3920 1950 3010 - - - -

40 3630 5610 2800 4320 3190 4850 2450 3750 40 2810 4360 2190 3340 - - - -

NOTES :
A. REINFORCEMENT UNDER CATEGORY 1:
1. CLEAR SPACING OF BARS BEING DEVELOPED OR SPLICED NOT LESS THAN BAR DIAMETER (db), CLEAR
COVER NOT LESS THAN db, AND STIRRUPS OR TIES THROUGHOUT Ld NOT LESS THAN THE PRESCRIBED MINIMUM.
OR
2. CLEAR SPACING OF BARS BEING DEVELOPED OR SPLICED NOT LESS THAN 2 db AND CLEAR COVER
NOT LESS THAN db.
B. REINFORCEMENT UNDER CATEGORY 2:
REINFORCEMENT WHICH DOES NOT COMPLY THE REQUIREMENTS UNDER CATEGORY 1.
C. BUTT SPLICING OR MECHANICAL CONNECTION (COUPLER) WILL BE PERMITTED IN LIEU OF LAPPING.

Client:

ORIGINAL DRAWING
IN COLOUR PRECOnISc., Green Sun (formerly Solid House), 2285 Don Chino
Roces Avenue Extension, 1231 Makati City, Philippines

Document No. 2790327-SE-0209.DWG


Project:

FOR TENDER SOLID LF


Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. STANDARD DRAWINGS STRUCTURAL
0 ISSUED FOR TENDER EFG FTF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SHEET 9 OF 9 Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-0209 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


www.beca.com ORIGINAL IN COLOUR Document No. 2790300-SE-2000.DWG
15/10/2021 9:23:51 AM

Rev.

IF IN DOUBT ASK.
0
Solid Integrated Logistics Facility

Beca Project Number: 2790300


Chino Roces Avenue Extension, 1231 Makati City, Philippines
Green Sun (formerly Solid House), 2285 Don

CALAMBA, LAGUNA, PHILIPPINES


2790300-SE-2110

2790300-SE-2120

2790300-SE-2130

2790300-SE-2140

2790300-SE-2150
SITE LEGEND AND NOTES

STRUCTURAL
2790300-SE-2000
SOLID LF
Drawing Plotted:

nIS
PRECO c.,

Drawing No.:
Discipline:
Project:
Client:

GENERAL ARRANGEMENT
NOT FOR CONSTRUCTION
FOR TENDER
ORIGINAL DRAWING
IN COLOUR

KEY PLAN
Title:
45

Beca Pp ilp
h iesLd
in t.
22.5

ScaeL,ndoelS M.rnzto,akiat
9vca6e,B
L31eFG dpslguil.bl

pne1is2Pl3hy,iC
R
pneBisaP

ti
rn(lch)i
Meters

1:750

Project Managers, Architecture and Engineering Consultants:


0
2790300-SE-2150

22.5
REFER DWG.

REFER DWG.
2790300-SE-2120

I ETEKTON
tct
inandConsru
iB4Waconre
PRM
Desg

ouSsnat.chE
3oea,st
&tnC
Semi-trailer

HR
1lhyM
n,iCatkiair
BU
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

pne1is8P
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

inCoalboravite

hoioceAsvenue
DEQA
Desg
Semi-trailer

efnckadg,ovB
ielui
1nR
(c) 2019 Transoft Solutions, Inc. All rights reserved.

oM
23C
MLIT 2014 (JP)

taikat
RD

y,iC
3lhM
pne1is2P
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

SUSTAINABILITY
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

PAVEMENT JOINT LAYOUT


Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

MANAGEMENT
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

ENGINEERING
Architects and Engineers:
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

2790300-SE-2130
2790300-SE-2140

Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

REFER DWG.
REFER DWG.

Approved For:

26-05-2022 Date: -
-
19-05-2022
19-05-2022
24-05-2022
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

1:750
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

EFG
FTF
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

JA

JJ
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

Dsg Verifier
1

Drg Check
-

Design
Drawn
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer

Scale (A1)

Scale (A3)
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

Reduced
-

-
2790300-SE-2110

Original
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
REFER DWG.

Semi-trailer

26-05-2022
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

Date
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

Appd
JG
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

Chk
FF
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

FG
Semi-trailer

By
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)
Semi-trailer
(c) 2019 Transoft Solutions, Inc. All rights reserved.
MLIT 2014 (JP)

Revision
k
H) uc
Truck

Tr
(P
(PH)

it
12
reserved.
Un
rights
All
Inc.
Solutions,
Transoft

20
2021
(c)
12
it

WH
DP le
reserved.

le Un
WH 20
All rights
Inc.
Solutions,

g
Transoft
(c) 2021

Sin
SingDP

DO NOT SCALE FOR SET OUT DIMENSIONS


ISSUED FOR TENDER
No.
0
Drawing Plotted: 15/10/2021 9:23:51 AM

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42

6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000
246880
6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000
ALL PEB ITEMS - NOT PART OF SCOPE
6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
TN
O.
27
18800

18800
90
30
0-S
12800

E-
23
40

www.beca.com
A
7500

7500
22500
7500

7500
7500

7500
B
7810

7815
RE
RE FE
FE R
RT TO
O SH
SH

ORIGINAL IN COLOUR
7815

7815
EE EE
TN TN
O. O.
27 27
31250

90 90
30 30
0-S 0-S
E -23 E-
23
7815

7815
11 12
7815

7810
C
7810

7815
7815

7815
31250
7815

7815
50
E-23
00-S
03
.279
NO

REFER TO SH
T
7815

7810
EE
O SH
RT
207600

D FE
RE

EET NO.27903
7810

7815
00-SE-2320
7815

7810
31250
7815

7810
7815

7810
E
7810

7480
13 14
23 23
E- E-
0-S 0-S
7815

7815
30 30
90 90
27
O. 27
O.
31250

TN N
EE ET
SH E
TO SH
7815

7815
FER TO
RE E R
REF
7815

7805
F
7500

7500
22500
7500

7500
7500

7500
G
RE
12800

12800
FE
R
TO
18800

SH
EE
TN

G'
O.
27
90
6000

30
0-S
E-

G"
23
30

Client:

Document No. WAREHOUSE COLUMN LAYOUT.DWG


ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don

1 OVERALL COLUMN LAYOUT Project:


Chino Roces Avenue Extension, 1231 Makati City, Philippines

- 1:500
FOR TENDER SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. OVERALL STRUCTURAL
0 ISSUED FOR TENDER EFG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier FTF
Drg Check JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
COLUMN LAYOUT Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-2310 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

7 8
SE-2512 SE-2512 NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000

A"

6000

www.beca.com
A' 18800
12800 C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f)

OUTBOUND STAGING AREA COLUMN


REFER SHEET NO. 2790300-SE-2340

1
A

ORIGINAL IN COLOUR
SE-2511

C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a)
7500

C4-(d)
22500
7500

C4-(d)
7500

2
SE-2511 B C4-(d) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c)

MACTH LINE REFER TO 2790300-SE-2312


7810

C4-(d)
7815
31250

C4-(d)
7815

C4-(d)
7815

3
SE-2511 C C4-(d) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c)
7810

C4-(d) 2790300-SE-2311
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
7815

6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
T NO
.27
18800

18800
903
00-
12800

SE
-23
40
A

7500

7500
22500
7500

7500
7500

7500
B

7815
7810
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
31250

.27 .27

31250
903 90
00- 30
SE 0-S
-23 E-2

7815

7815
11 31
2

7815

7810
C

7810

7815
7815

7815
C4-(d)

31250
7815

7815
50
-23
SE
00-
903
.27
T NO

REFER TO SHEET
7815

7810
EE
SH
TO

207600
D FER
RE

7810

7815
NO.2790300-SE
7815

7810
-2320
31250
7815

7810
7815

7815

7810
E

7810

7480
13 4
-23 31
SE E-2

7815

7815
00- 0-S
903 30
.27 90
.27

31250
T NO NO
EE T
SH EE
TO SH

7815

7815
R TO
FE R
RE FE
RE

7815

7805
F

7500

7500
22500
7500

7500
7500

7500
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-23
30
C4-(d) KEY PLAN
7815

Client:

Document No. WAREHOUSE COLUMN LAYOUT.DWG


ORIGINAL DRAWING
207600

4
SE-2511 D C1-(a) C2-(b) C2-(b) C2-(b) C2-(b) C2-(b) C2-(b) C2-(b) C2-(b) C2-(b) C2-(b) IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines
MACTH LINE REFER TO 2790300-SE-2313
ALL PEB ITEMS - NOT PART OF SCOPE Project:

1 MAIN WAREHOUSE COLUMN LAYOUT FOR TENDER SOLID LF


- 1:250 NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. MAIN WAREHOUSE STRUCTURAL
0 ISSUED FOR TENDER EFG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier FTF
Drg Check JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
COLUMN LAYOUT Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti SHEET 1 OF 4 2790300-SE-2311 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.
246880
6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

A" C6-(f) C6-(f)

www.beca.com
C6-(f)
A' C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f)
18800

18800
OUTBOUND STAGING AREA COLUMN
REFER SHEET NO. 2790300-SE-2340

1
A

ORIGINAL IN COLOUR
SE-2511

C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a)

7500
C4-(d)
22500

7500
C4-(d)

7500
MACTH LINE REFER TO 2790300-SE-2311

2
SE-2511 B C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C4-(d)

7810
C4-(d)
OFFICE & AMENITIES, GENSET,
MATERIALS RECYLCING FACILITY

7815
REFER SHEET NO. 2790300-SE-2320
31250

C4-(d)

7810
C4-(d)

7815
3
SE-2511 C C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C4-(d)

7810
C4-(d) 2790300-SE-2312
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880

7815
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
T NO
.27
18800

18800
903
00-
12800

SE
-23
40
A

7500

7500
22500
7500

7500
7500

7500
B

7815
7810
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
31250

.27 .27

31250
903 90
00- 30
SE 0-S
-23 E-2

7815

7815
11 31
2

C4-(d)

7815

7810
C

7810

7815
7815

7815
31250
7815

7815
50
-23
SE
00-
903
.27
T NO

REFER TO SHEET
7815

7810
EE
SH
TO

207600
D FER
RE

7810

7815
NO.2790300-SE
7815

7810
-2320
31250
7815

7810
7815

7815

7810
E

7810

7480
13 4
-23 31
SE E-2

7815

7815
00- 0-S
903 30
.27 90
.27

31250
T NO
EE T NO
SH EE
TO SH

7815

7815
R TO
FE R
RE FE
RE

7815

7805
F

7500

7500
22500
7500

7500
7500

7500
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-23
30
KEY PLAN
C4-(d)

7810
Client:

Document No. WAREHOUSE COLUMN LAYOUT.DWG


ORIGINAL DRAWING
207600

4
SE-2511 D C2-(b) C2-(b) C2-(b) C2-(b) C2-(b) C2-(b) C2-(b) C2-(b) C2-(b) C2-(b) C1-(a) IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines
MACTH LINE REFER TO 2790300-SE-2314
Project:
ALL PEB ITEMS - NOT PART OF SCOPE
1 MAIN WAREHOUSE COLUMN LAYOUT FOR TENDER SOLID LF
- 1:250 NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. MAIN WAREHOUSE STRUCTURAL
0 ISSUED FOR TENDER EFG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier FTF
Drg Check JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
COLUMN LAYOUT Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti SHEET 2 OF 4 2790300-SE-2312 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

7 8
SE-2512 SE-2512 NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000

MACTH LINE REFER TO 2790300-SE-2311

7810

www.beca.com
C4-(d)
7815
31250

C4-(d)
7810

ORIGINAL IN COLOUR
C4-(d)

ALL PEB ITEMS - NOT PART OF SCOPE


7815

E C4-(d) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c)
7810

C4-(d)
7815
31250

MACTH LINE REFER TO 2790300-SE-2314


C4-(d)
7815

C4-(d)
7815

580 TYP.

C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c)

600 TYP.
5
SE-2512 F C4-(d) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e)
7500

580 TYP.

C4-(d) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e)
22500
7500

580 TYP.

580
C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e)
C4-(d)
580 TYP.
7500

TYPICAL
850
6 C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) 2790300-SE-2313
SE-2512 G C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
T NO
.27
18800

18800
903
00-
12800

SE
-23
40
A

7500

7500
22500
7500

7500
7500

7500
B

7815
7810
RE
12800

RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
.27 .27

31250
903 90
00- 30
SE 0-S
-23 E-2

7815

7815
11 31

INBOUND STAGING AREA COLUMN


2

7815

7810
C

7810

7815
7815

7815
REFER SHEET NO. 2790300-SE-2330

31250
7815

7815
50
-23
SE
00-
903
.27
T NO

REFER TO SHEET
7815

7810
EE
SH
18800

TO

207600
D FER
RE

7810

7815
NO.2790300-SE
7815

7810
-2320
31250
7815

7810
7815

7810
E

7810

7480
13 4
-23 31
SE E-2

7815

7815
00- 0-S
903 30
.27 90
.27

31250
T NO NO
EE T
SH EE
TO SH

7815

7815
R TO
FE R
RE FE
RE

7815

7805
F

7500

7500
G'

22500
7500

7500
7500

7500
G

C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f)

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-23
30
6000

KEY PLAN
2925 1945 1125 325 475 4725 3925 3125 2325 1525

G" Client:

Document No. WAREHOUSE COLUMN LAYOUT.DWG


ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:
1 MAIN WAREHOUSE COLUMN LAYOUT FOR TENDER SOLID LF
- 1:250 NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. MAIN WAREHOUSE STRUCTURAL
0 ISSUED FOR TENDER EFG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier FTF
Drg Check JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
COLUMN LAYOUT Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti SHEET 3 OF 4 2790300-SE-2313 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
25 1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
22 23 24 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
246880
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.
6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

MACTH LINE REFER TO 2790300-SE-2312

7815
C4-(d)

www.beca.com
7815
31250

C4-(d)

7810
C4-(d)

ALL PEB ITEMS - NOT PART OF SCOPE

ORIGINAL IN COLOUR
7815
C4-(d)

E
C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c)

7480
C4-(d)

7815
OFFICE & AMENITIES, GENSET,
MATERIALS RECYLCING FACILITY C4-(d)
REFER SHEET NO. 2790300-SE-2320
31250

7810
MACTH LINE REFER TO 2790300-SE-2313

7805
1020 C4-(d)

5 C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c) C3-(c)
F

600
SE-2512
C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e)
C4-(d)

7500
1020
C4-(d)

C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e)
22500

7500
C5-(e)
C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e)
C4-(d)

7500
1020
6 C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e) C5-(e)
SE-2512 G C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a) C1-(a)
2790300-SE-2314
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

12800

RE
A"

FE
R
TO
6000

SH
EE
T NO
.27
18800

18800
903
00-
12800

SE
-23
40
A

7500

7500
22500
7500

7500
INBOUND STAGING AREA COLUMN

7500

7500
B

7815
7810
RE
RE FE
FE R
R TO TO
18800

SH SH

7815

7815
EE EE
T NO T NO
.27 .27

31250
903 90

REFER SHEET NO. 2790300-SE-2330


00- 30
SE 0-S
-23 E-2

7815

7815
11 31
2

7815

7810
C

7810

7815
7815

7815
31250
7815

7815
50
-23
SE
00-
903
.27
T NO

REFER TO SHEET
7815

7810
EE
SH
TO

207600
D FER
RE

7810

7815
NO.2790300-SE
7815

7810
-2320
31250
G'

7815

7810
7815

7810
E

7810

7480
C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) C6-(f) SE
-23
13
E-2
31
4

7815

7815
00- 0-S
903 30
.27 90
.27
T NO

31250
EE T NO
SH EE
TO SH

7815

7815
R TO
FE R
RE FE
RE

7815

7805
F

7500

7500
22500
7500

7500
7500

7500
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-23
30
G" C6-(f) C6-(f) C6-(f)
KEY PLAN
Client:
215 1915 1785 2785 1985 1185 385 415 1215 1020

Document No. WAREHOUSE COLUMN LAYOUT.DWG


ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

1 MAIN WAREHOUSE COLUMN LAYOUT FOR TENDER


Project:

- 1:250 SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. MAIN WAREHOUSE STRUCTURAL
0 ISSUED FOR TENDER EFG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier FTF
Drg Check JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
COLUMN LAYOUT Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti SHEET 4 OF 4 2790300-SE-2314 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26

6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000

580 5420 6000 580 4840 580 6000 580 2050 580 6000 580 4840 580 6000 580 11420 580 4840 580 6480 580 11420 580 4840 580 6000
1195 1595

www.beca.com
F

775
p (TYPICAL)

6725
FOR MEMBERS DETAIL REFER TO SECTION 8 GL 11 TO 41

FOR MEMBERS DETAIL REFER

(SHEET NO. 2790300-SE- 2316)


TO SECTION 8 GL 11 TO 41
q (TYPICAL)
22500
7500

MACTH LINE

ORIGINAL IN COLOUR
7500

q
G

ALL PEB ITEMS - NOT PART OF SCOPE

27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42

6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

6000 580 4840 580 6000 580 4840 580 6000 580 4840 580 6000 580 4840 580 6000 580 4840 580 6000 2790 2050 6000 580 4840 580 6000 580 4600 1020
580 580

F
775

p (TYPICAL)
6725

FOR MEMBERS DETAIL REFER TO SECTION 8 GL 11 TO 41

FOR MEMBERS DETAIL REFER

(SHEET NO. 2790300-SE- 2316)


(SHEET NO. 2790300-SE- 2316)
MACTH LINE

TO SECTION 8 GL 11 TO 41
q (TYPICAL)
22500
7500

q
7500

2790300-SE-2315

G
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
T NO
.27
18800

18800
903
00-
12800

SE
-23
40
A

ALL PEB ITEMS - NOT PART OF SCOPE

7500

7500
22500
7500

7500
7500

7500
B

7815
7810
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
.27 .27

31250
903 90
00- 30
SE 0-S
-23 E-2

7815

7815
11 31
2

7815

7810
C

7810

7815
7815

7815
31250
7815

7815
50
-23
SE
00-
903
.27
T NO

REFER TO SHEET
7815

7810
EE
SH
TO

207600
D FER
RE

7810

7815
NO.2790300-SE
7815

7810
-2320
31250
7815

7810
7815

7810
E

7810

7480
13 4
-23 31
SE E-2

7815

7815
00- 0-S
903 30
.27 90
.27

31250
T NO
EE T NO
SH EE
TO SH

7815

7815
R TO
FE R
RE FE
RE

7815

7805
F

7500

7500
22500
7500

7500
7500

7500
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-23
30
1 MEZZANINE - VAZ AREA BEAM LAYOUT KEY PLAN
- 1:250 Client:

Document No. WAREHOUSE COLUMN LAYOUT.DWG


ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER SOLID LF


NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. MAIN WAREHOUSE STRUCTURAL
0 ISSUED FOR TENDER EFG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier FTF
Drg Check JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
MEZZANINE Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti VAZ AREA BEAM LAYOUT 2790300-SE-2315 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
ALL PEB ITEMS - NOT PART OF SCOPE NOTES:
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
A" n
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.

6000
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.
k (TYPICAL)
l

MACTH LINE (CANOPY ALONG GL A)


A'

i (TYPICAL)
18800

m
n

12800

www.beca.com
l
A

23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 PEB ITEMS
ALL 39 40 PART41OF SCOPE
- NOT 42

6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200
A" l
6000

n
MACTH LINE (CANOPY ALONG GL A)

ORIGINAL IN COLOUR
n n l
A'
i (TYPICAL)

m
18800

m
n
12800

l
A
k (TYPICAL)

1 ROOF CANOPY ALONG GL A'


- 1:250

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
ALL PEB ITEMS - NOT PART 6000
OF SCOPE

MACTH LINE (CANOPY ALONG GL G)


6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000
p
G
l
12800

n
i (TYPICAL)
18800

m
l
G'
k (TYPICAL)
6000

n
G"

23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
ALL PEB ITEMS - NOT PART OF SCOPE
6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200
p p
2790300-SE-2316
G l
l 1

6200
2

6000
3

6000
4

6000
5

6000
6

6000
7

6000
8

6000
9

6000
10

6000
11

6000
12

6000
13

6000
14

6000
15

6000
16

6000
17

6000
18

6000
19

6000
20

6000
21
246880
6000
22

6480
23

6000
24

6000
25

6000
26

6000
27

6000
28

6000
29

6000
30

6000
31

6000
32

6000
33

6000
34

6000
35

6000
36

6000
37

6000
38

6000
39

6000
40

6000
41

6200
42
MACTH LINE (CANOPY ALONG GL G)

RE
A"

FE
R
TO
6000

SH
EE
T NO
.27
18800

18800
903
00-
12800

SE
-23
40
A

7500

7500
22500
7500

7500
7500

7500
B

7815
7810
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
12800

T NO T NO
.27 .27

31250
903 90

n
00- 30
SE 0-S
-23 E-2

7815

7815
11 31
2

7815

7810
C

7810

7815
7815

7815
i (TYPICAL)

31250
7815

7815
50
-23
SE
00-
903
.27
T NO

REFER TO SHEET
7815

7810
EE
SH
TO

207600
D FER
RE
18800

7810

7815
NO.2790300-SE
7815

7810
-2320
31250
7815

7810
m

7815

7810
E

7810

7480
13 4
-23 31
SE E-2

7815

7815
00- 0-S
903 30
.27 90
.27

31250
T NO
EE T NO
SH EE
TO SH

7815

7815
R TO
FE R
RE FE
RE

7815

7805
n l
F

n l

7500

7500
G'

22500
7500

7500
7500

7500
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-23
30
6000

KEY PLAN
l n
G" Client:

Document No. WAREHOUSE COLUMN LAYOUT.DWG


k (TYPICAL) o (TYPICAL) ORIGINAL DRAWING
n
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

2 ROOF CANOPY ALONG GL G' FOR TENDER


Project:

- 1:250 SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. MAIN WAREHOUSE STRUCTURAL
0 ISSUED FOR TENDER EFG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier FTF
Drg Check JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
ROOF CANOPY LAYOUT Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-2316 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

LC 150X65X2.0MM
@ 1000mm O.C.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42

www.beca.com
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

A
7500

s
22500
7500

t
7500

s
B

ORIGINAL IN COLOUR
7810

s
7815

t
31250
7815

v (TYPICAL)
t

t
c - TYPICAL
7815

s
r - TYPICAL FOR GL. A TO G (FOR MEMBERS DETAIL REFER TO DRAWING NO. 2790300-SE- 2314)
C
7810

s
TYPICAL FOR GL. 11 TO 42 (FOR MEMBERS DETAILS REFER TO DRAWING NO. 2790300-SE- 2314)
TYPICAL FOR GL. 1 TO 10 (FOR MEMBERS DETAILS REFER TO DRAWING NO. 2790300-SE- 2314)
7815

u (TYPICAL)
t

t
31250
7815

t
7815

s
170000

D
7810

s
7815

t
31250
7810

t
7815

E
7810

s
7815

t
31250
7815

t
7815

F 2790300-SE-2318
7500

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
s

6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
T NO
.27
18800

18800
903
00-
12800

SE
-21
40
A

s
7500

7500
22500

t
7500

7500
s

s
7500

7500
22500

B
7500

s
7810

7815
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
t

t
EE EE
T NO T NO
.27 .27

31250
t

903 90
00- 30
SE 0-S
-21 E-2

t
7815

7815
15 11
6

s
7815

7810
C

s
7810

7815
t

t
7815

7815
31250
u u u u u

t
7815

7815
50
-21
SE
00-
903
.27
T NO

REFER TO SHEET
s

s
7815

7810
EE
SH
TO

207600
D FER
RE

s
7810

7815
NO.2790300-SE
7500

7815

7810
t

t
s

-2120
31250

t
7815

7810
s

s
7815

7810
E

s
7810

7480
17 8
-21 11
SE E-2

7815

7815
t

t
00- 0-S

G
903 30
.27 90

r
.27

31250
T NO
EE T NO
SH EE
TO SH

7815

7815
t

t
R TO
FE R
RE FE
RE

s
7815

7805
F

7500

7500
22500
7500

7500
t

t
s

s
7500

7500
r
G

RE
12800

12800
ALL PEB ITEMS - NOT PART OF SCOPE

FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-21
30
KEY PLAN
Client:

Document No. WAREHOUSE COLUMN LAYOUT.DWG


ORIGINAL DRAWING
1 MAIN WAREHOUSE ROOF LAYOUT IN COLOUR
- 1:500 PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER SOLID LF


NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. MAIN WAREHOUSE STRUCTURAL
0 ISSUED FOR TENDER EFG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier FTF
Drg Check JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
ROOF LAYOUT Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-2318 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

2 NOTES:
SE-2521
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
42
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

6645
MATCHLINE
E1 E2 E3
A" 16440 4 C11-(c) C11-(c) C11-(c) EO

4120 1160
5785
SE-2520
560 7440 9000
D C12 C12 C12 C12
FA

5275
EA
C11-(c) C11-(c) C11-(c)
C12 C12
FC

1330 3710
18800

5035
8000

8000

www.beca.com
C12 C12
FE
EB

5035

5035
C11-(c) C11-(c) C11-(c)

5015
FF

8000

3810 1445
31250
C12 C12 C12 C12
A

5260
2985
C11-(c) C11-(c) C11-(c)
EC FH
C12 C12 C12 C12

3485 265 4250

4250

4000
c

DESIGN ON HOLD

6065
ED

ORIGINAL IN COLOUR
2065
C11-(c) C11-(c) C11-(c)

3750
FJ

22500
C12 125MM THK. SLAB ON FILL C12
C11-(c) C11-(c)
EE WITH Ø 10 @ 150 O.C.

5735
C11-(c)

6065
BOTH WAYS WITH 75MM THK

4015
GRAVEL BEDDING (TYP.)

8000
E

335
FK

3985
C12 C12
3

6065

6065
SE-2521
C11-(c) C11-(c) C11-(c)
EF
3515
FL

4315 1410
B

8000
C12 C12 C12 C12

5725
4485

C11-(c) C11-(c) C11-(c)


EG FN
3325

C12 C12

7202225 3500

5725
1

31250
8000
SE-2520
4675

C12 C12 C12 C12


FP

720
C13-(j)j C13-(j)j j

96845
C13-(j)
EH

4865
C11-(c) C11-(c) C11-(c)
RA
3140

5660
31250

8000

795
RB
4860

C14-(w) C14-(w)

5570

5570
EI
2950

C11-(c) C11-(c) C11-(c)


RC

3275 1450
C13-(j)j C13-(j) j
C13-(j)
8000 F

5500
5050

775
EJ C14-(w) C14-(w)
RD
2765

3450
C11-(c) C11-(c) C11-(c)

6250
C
8000

2800
5235

RE

22500
C14-(w) C14-(w)

300 4700
EK

5000
2575

C11-(c) C11-(c) C11-(c)

RF
8000

C15-(f) f
C15-(f) f
C15-(f)
5425

6350

6350
EL
2430 3400 1980 2390

C11-(c) C11-(c) C11-(c)


VD
850
31250

4370

G C15-(f) C15-(f) C13-(j)


2790300-SE-2320
C11-(c) C11-(c)
EM 5660
ALL PEB ITEMS - NOT PART OF SCOPE
5410 5660 1510
3400

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
EN

T NO
.27
18800

18800
903
00-
12800

SE
-21
40
A

7500

7500
C11-(c) C11-(c) C11-(c) F1 F2 F3 F4 F5

22500
7500

7500
7500

7500
B

7815
7810
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
.27 .27

31250
903 90
00- 30
SE 0-S
-21 E-2

7815

7815
15 11
6

7815

7810
C

7810

7815
9075

7815

7815
31250
7815

7815
50
-21
SE
00-
903
.27
T NO

REFER TO SHEET
7815

7810
EE
6645

SH
TO

207600
D FER
RE

7810

7815
NO.2790300-SE
7815

7810
-2120
31250
7815

7810
7815

7810
E

7810

7480
17 8
-21 11
SE E-2

7815

7815
00- 0-S
30

C11-(c)
EO
903 90
.27 .27

31250
T NO
EE T NO

C11-(c)
SH EE

4
TO SH

7815

7815
R TO

C11-(c)
FE R
RE FE
RE

7815

7805
F

7500

7500
1160

22500
7500

7500
SE-2520 MATCHLINE

7500

7500
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-21
30
ALL PEB ITEMS - NOT PART OF SCOPE KEY PLAN Client:

ORIGINAL DRAWING
IN COLOUR
1 MAIN OFFICE AND AMENITIES GROUND FLOOR COLUMN LAYOUT PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

- 1:250 Project:

Document No. MAIN OFFICE.DWG


FOR TENDER SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. MAIN OFFICE AND AMENITIES STRUCTURAL
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
GROUND FLOOR Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti COLUMN LAYOUT 2790300-SE-2320 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
42 2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.
E1 E2 E3
A" 16440
560 7440 9000

5785
c c c EA

18800
8000

8000

www.beca.com
c c c EB

5015

8000
A

2985
c c c EC

3485 265 4250

4250
ED

ORIGINAL IN COLOUR
c c c

3750
22500
c c c EE

4015

8000
3985
c c c EF

3515
B

8000
4485
c c c EG

3325

8000
4675

96845
c c c EH

3140
31250

8000
4860

c c c EI
2950

8000
5050

c c c EJ
2765

8000
5235

c c c EK
2575

8000
5425

c c c EL
2430 3400 1980 2390
31250

4370

2790300-SE-2321
c c c EM
3400

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
EN

T NO
.27
18800

18800
903
00-
12800

SE
-21
40
c c c
A

7500

7500
22500
7500

7500
7500

7500
B

7815
7810
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
.27 .27

31250
903 90
00- 30
SE 0-S
-21 E-2

7815

7815
15 11
6

7815

7810
C

7810

7815
9075

7815

7815
31250
7815

7815
50
-21
SE
00-
903
.27
T NO

REFER TO SHEET
7815

7810
EE
6645

SH
TO

207600
D FER
RE

7810

7815
NO.2790300-SE
7815

7810
-2120
31250
7815

7810
7815

7810
E

7810

7480
17 8
-21 11
SE E-2

7815

7815
00- 0-S
903 30
.27 90
.27

31250
T NO
EE T NO
SH EE
TO SH

7815

7815
R TO
FE R
RE FE
RE

7815

7805
EO
F
1170

7500

7500
22500
7500

7500
c c c

7500

7500
D
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-21
30
ALL PEB ITEMS - NOT PART OF SCOPE KEY PLAN Client:

ORIGINAL DRAWING
1 MAIN OFFICE AND AMENITIES SECOND FLOOR COLUMN LAYOUT IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don

- 1:250
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

Document No. MAIN OFFICE.DWG


FOR TENDER SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. MAIN OFFICE AND AMENITIES STRUCTURAL
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SECOND FLOOR Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti COLUMN LAYOUT 2790300-SE-2321 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
42 2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.
E1 E2 E3
A" 16440
560 7440 9000

5785
125 THK SLAB ON 1.0mm 2400 2400 2465 2825 3000 3000
DN3 STEEL TRAY DECK EA
CONTINUES OVER BEAM za za
REINFORCE SLAB WITH 10mm

18800
8000

8000
BARS SPACED @ 200 c/c

www.beca.com
S1 S1 S1 S1 S1 S1

EB

5015

8000
S1 S1 S1 S1 S1 S1
A

2985
EC

3485 265 4250

4250
S1 S1 S1 S1 S1 S1
ED

ORIGINAL IN COLOUR
3750
zb
S1 S1 S1 S1

22500
EE

4015

8000
S1 S1 S1 S1 S1 S1

3985
EF

3515
B

8000
S1 S1 S1 S1 S1 S1

4485
EG

3325

8000
S1 S1 S1 S1 S1 S1

4675
q (TYPICAL)

96845
EH

3140
S1
31250

zb ( TYPICAL)

8000
S1 S1 S1 S1 S1

za

za

za
4860

EI
2950

8000
S1 S1 S1 S1 S1 S1
5050

EJ
2765

8000
S1 S1 S1 S1 S1 S1
5235

EK
2575

8000
S1 S1 S1 S1 S1 S1
5425

EL
2430 3400 1980 2390
31250

4370

S1 S1 S1 S1 S1 S1
2790300-SE-2322
EM
3400

S1 S1 S1 S1 S1 S1 1

6200
2

6000
3

6000
4

6000
5

6000
6

6000
7

6000
8

6000
9

6000
10

6000
11

6000
12

6000
13

6000
14

6000
15

6000
16

6000
17

6000
18

6000
19

6000
20

6000
21
246880
6000
22

6480
23

6000
24

6000
25

6000
26

6000
27

6000
28

6000
29

6000
30

6000
31

6000
32

6000
33

6000
34

6000
35

6000
36

6000
37

6000
38

6000
39

6000
40

6000
41

6200
42

RE
A"

FE
R
TO
6000

SH
EE
EN

T NO
.27
18800

18800
903
00-
12800

SE
-21
40
A

7500

7500
22500
7500

7500
7500

7500
B

7815
7810
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
.27 .27

31250
903 90
00- 30
SE 0-S
-21 E-2

7815

7815
15 11
6

7815

7810
C

7810

7815
9075

7815

7815
S1 S1 S1 S1 S1 S1

31250
7815

7815
50
-21
SE
00-
903
.27
T NO

REFER TO SHEET
7815

7810
EE
6645

SH
TO

207600
D FER
RE

7810

7815
NO.2790300-SE
7815

7810
-2120
31250
7815

7810
7815

7810
E

7810

7480
17 8
-21 11
SE E-2

7815

7815
00- 0-S
903 30
.27 90
.27

31250
T NO NO
EE T
SH EE
SH

za za
TO

7815

7815
R TO
FE R
RE FE
RE

7815

7805
EO
F
1170

7500

7500
22500
7500

7500
7500

7500
D
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-21
30
ALL PEB ITEMS - NOT PART OF SCOPE KEY PLAN Client:

ORIGINAL DRAWING
1 MAIN OFFICE SECOND FLOOR BEAM LAYOUT IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don

- 1:250
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

Document No. MAIN OFFICE.DWG


FOR TENDER SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
-
Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. MAIN OFFICE AND AMENITIES STRUCTURAL
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SECOND FLOOR Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti BEAM LAYOUT 2790300-SE-2322 0
DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.
Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
MATCHLINE
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
42

w
zc

zc
y

y
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.
m EO
E1 E2 E3

1170
RB RB RB
A" D
FA

5275
16440

RB

RB
560 7440 9000
i
FC

W18 RAFTER

W18 RAFTER
m
EA

5035
RB

RB
zc i

18800
FE

8000

www.beca.com
LC 150X65X2.0mm zc

5035
RB

RB
@ 1000mm O.C.
m
EB RB RB RB FF

31250
zd
zc

5260
PLANTED

FTB
8000

RB
COLUMN

m
A zc
RB RB RB FH
m
EC

6065
k (TYP.)
DESIGN ON HOLD

RB

RB
4250
m m i
ED FJ

ORIGINAL IN COLOUR
3750

6065
RB

RB
m

22500
EE i
E FK

8000

6065
RB

RB
COLD FORMED
STEEL PURLINS

EF RB RB RB FL

17850

5725
RB

RB
B

8000
i
FN
EG

5725
31250
LC 150X65X2.0mm

RB

RB
@ 1000mm O.C.
RB RB RB
FP

720

720
8000
RB RB RB

RA

5660
96845
EH
i
RB

12680
31250

8000

5570
i
i
EI RC
F

5500
8000

i
RD

6250
15000
EJ LC 150X65X2.0mm LC 150X65X2.0mm
@ 1000mm O.C. @ 1000mm O.C.

n
l

l
C i
RE

22500
8000

190 5000
m (TYPICAL) i
EK m RF

6160
6550
8000

n
VD

200
650
G m
EL
30080

zc
31250

ALL PEB ITEMS - NOT PART OF SCOPE


4370

m 2790300-SE-2323
EM
3400

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
EN

T NO
.27
18800

18800
903
00-
12800

SE
-21
40
A

7500

7500
22500
7500

7500
u (TYP.)

7500

7500
B

7815
7810
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
.27 .27

31250
903 90
00- 30
SE 0-S
-21 E-2

7815

7815
15 11
6

7815

7810
C

zc

7810

7815
9075

7815

7815
31250
7815

7815
50
-21
SE
00-
903
.27
T NO

REFER TO SHEET
7815

7810
EE
SH
TO

207600
D FER
RE

7810

7815
NO.2790300-SE
7815

7810
-2120
31250
w
zc

zc

7815

7810
y

7815

7810
E

7810

7480
17 8
-21 11
SE E-2

7815

7815
00- 0-S
30

EO
903 90
.27 .27

31250
T NO NO
EE T
SH EE
SH

m
TO

7815

7815
R TO
FE R
RE FE
RE

7815

7805
F
1170

7500

7500
22500
7500

7500
RB RB RB

7500

7500
D
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
FA
G'

.27
903
6000

00-
5275

SE
G"

-21
30
KEY PLAN
RB

RB

MATCHLINE Client:

ALL PEB ITEMS - NOT PART OF SCOPE


ORIGINAL DRAWING
IN COLOUR
1 MAIN OFFICE AND AMENITIES ROOF LAYOUT PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

- 1:250 Project:

Document No. MAIN OFFICE.DWG


FOR TENDER SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. MAIN OFFICE AND AMENITIES STRUCTURAL
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
ROOF LAYOUT Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-2323 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

www.beca.com
S1 S2 S3 S4
17600

7175 6000 4425

675
SA
C21(c) C21(c) C21(c) C21(c)

ORIGINAL IN COLOUR
5800
1
SE-2531 SB
C21(c) C21(c) C21(c) C21(c)

5800
22625

SC
525

G' C21(c) C21(c) C21(c) C21(c)


5075

SD
925

C21(c) C21(c) C21(c) C21(c)


G"
4500

SE C21(c) C21(c) C21(c) C21(c)

ALL PEB ITEMS - NOT PART OF SCOPE

2790300-SE-2330
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
T NO
.27
18800

18800
903
00-
12800

SE
-21
40
A

7500

7500
22500
7500

7500
7500

7500
B

7815
7810
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
.27 .27

31250
903 90
00- 30
SE 0-S
-21 E-2

7815

7815
15 11
6

7815

7810
C

7810

7815
7815

7815
31250
INBOUND OFFICE BUILDING GROUND FLOOR COLUMN LAYOUT

7815

7815
50
-21
SE
00-
903

1
.27
T NO

REFER TO SHEET
7815

7810
EE
SH
TO

207600
D FER
RE

7810

7815
NO.2790300-SE
7815

7810
-2120
31250
7815

7810
7815

7810
-
E

7810

7480
1:100 SE
-21
17
E-2
11
8

7815

7815
00- 0-S
903 30
.27 90
.27

31250
T NO
EE T NO
SH EE
TO SH

7815

7815
R TO
FE R
RE FE
RE

7815

7805
F

7500

7500
22500
7500

7500
7500

7500
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-21
30
Client:

ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER SOLID LF

Document No. INBOUND.DWG


NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct
Beca Pp h
ilp
in
iesLd
t. INBOUND OFFICE BUILDING STRUCTURAL
pneBisaP
rn(lch)i
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
GROUND FLOOR Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti COLUMN LAYOUT 2790300-SE-2330 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

www.beca.com
S1 S2 S3 S4
17600

7175 6000 4425

675
SA c c c c

ORIGINAL IN COLOUR
5800
SB c c c c

5800
22625

SC
525

G' c c c c
5075

SD
925

c c c c
G"
4500

SE c c c c

ALL PEB ITEMS - NOT PART OF SCOPE

2790300-SE-2330
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
T NO
.27
18800

18800
903
00-
12800

SE
-21
40
A

7500

7500
22500
7500

7500
7500

7500
B

7815
7810
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
.27 .27

31250
903 90
00- 30
SE 0-S
-21 E-2

7815

7815
15 11
6

7815

7810
C

7810

7815
7815

7815
31250
INBOUND OFFICE BUILDING 2ND AND 3RD FLOOR COLUMN LAYOUT

7815

7815
50
-21
SE
00-
903

1
.27
T NO

REFER TO SHEET
7815

7810
EE
SH
TO

207600
D FER
RE

7810

7815
NO.2790300-SE
7815

7810
-2120
31250
7815

7810
7815

7810
-
E

7810

7480
1:100 SE
-21
17
E-2
11
8

7815

7815
00- 0-S
903 30
.27 90
.27

31250
T NO
EE T NO
SH EE
TO SH

7815

7815
R TO
FE R
RE FE
RE

7815

7805
F

7500

7500
22500
7500

7500
7500

7500
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-21
30
Client:

ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER SOLID LF

Document No. INBOUND.DWG


NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct
Beca Pp h
ilp
in
iesLd
t. INBOUND OFFICE BUILDING STRUCTURAL
pneBisaP
rn(lch)i
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
2ND AND 3RD FLOOR Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti COLUMN LAYOUT 2790300-SE-2331 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

www.beca.com
S1 S2 S3 S4
17600

7175 6000 4425

675
SA

x (TYPICAL)

ORIGINAL IN COLOUR
m (TYPICAL)
5800
SB

1940
585
x

5800
x x

22625
SC

525
G'

5075

SD
925

G"
4500

SE

ALL PEB ITEMS - NOT PART OF SCOPE

2790300-SE-2333
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
T NO
.27
18800

18800
903
00-
12800

SE
-21
40
A

7500

7500
22500
7500

7500
7500

7500
B

7815
7810
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
.27 .27

31250
903 90
00- 30
SE 0-S
-21 E-2

7815

7815
15 11
6

7815

7810
C

7810

7815
7815

7815
31250
INBOUND OFFICE BUILDING 2ND AND 3RD FLOOR BEAM LAYOUT

7815

7815
50
-21
SE
00-
903

1
.27
T NO

REFER TO SHEET
7815

7810
EE
SH
TO

207600
D FER
RE

7810

7815
NO.2790300-SE
7815

7810
-2120
31250
7815

7810
7815

7810
-
E

7810

7480
1:100 SE
-21
17
E-2
11
8

7815

7815
00- 0-S
903 30
.27 90
.27

31250
T NO
EE T NO
SH EE
TO SH

7815

7815
R TO
FE R
RE FE
RE

7815

7805
F

7500

7500
22500
7500

7500
7500

7500
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-21
30
Client:

ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER SOLID LF

Document No. INBOUND.DWG


NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct
Beca Pp h
ilp
in
iesLd
t. INBOUND OFFICE BUILDING STRUCTURAL
pneBisaP
rn(lch)i
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
2ND AND 3RD FLOOR Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti BEAM LAYOUT 2790300-SE-2333 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

www.beca.com
S1 S2 S3 S4
17600

7175 6000 4425

675
za
SA

LC 150X65X2.0mm

ORIGINAL IN COLOUR
PURLINS SPACED
@ 1000mm O.C.

5800
SB

u (TYP.)

5800
22625
SC

525
G'

5075
q (TYPICAL)
SD
925

G"

za (TYPICAL)
4500

za
SE

ALL PEB ITEMS - NOT PART OF SCOPE

2790300-SE-2335
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
T NO
.27
18800

18800
903
00-
12800

SE
-21
40
A

7500

7500
22500
7500

7500
7500

7500
B

7815
7810
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
.27 .27

31250
903 90
00- 30
SE 0-S
-21 E-2

7815

7815
15 11
6

7815

7810
C

7810

7815
7815

7815
31250
INBOUND OFFICE BUILDING ROOF FRAMING LAYOUT

7815

7815
50
-21
SE
00-
903

1
.27
T NO

REFER TO SHEET
7815

7810
EE
SH
TO

207600
D FER
RE

7810

7815
NO.2790300-SE
7815

7810
-2120
31250
7815

7810
7815

7810
-
E

7810

7480
1:100 SE
-21
17
E-2
11
8

7815

7815
00- 0-S
903 30
.27 90
.27

31250
T NO
EE T NO
SH EE
TO SH

7815

7815
R TO
FE R
RE FE
RE

7815

7805
F

7500

7500
22500
7500

7500
7500

7500
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-21
30
Client:

ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER SOLID LF

Document No. INBOUND.DWG


NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct
Beca Pp h
ilp
in
iesLd
t. INBOUND OFFICE BUILDING STRUCTURAL
pneBisaP
rn(lch)i
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
ROOF FRAMING LAYOUT Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-2335 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

www.beca.com
SE-2541

19 20 21 22

N1 N2 N3 N4
17700

3005 2995 2905 3095


ALL PEB2805ITEMS - NOT
3195 2705
PART OF SCOPE

ORIGINAL IN COLOUR
NA
C31(c) C31(c) C31(c) C31(c)

4525
A"

2675
1
SE-2541 NB C31(c) C31(c) C31(c) C31(c)

3325

A'
725

NC C31(c) C31(c) C31(c) C31(c)


22650

5700

ND C31(c) C31(c) C31(c) C31(c)


5700

NE
675

C31(c) C31(c) C31(c) C31(c)


A
2790300-SE-2340
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
T NO
.27
18800

18800
903
00-
12800

SE
-21
40
A

7500

7500
22500
7500

7500
7500

7500
B

7810

7815
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
.27 .27

31250
903 90
00- 30
SE 0-S
-21 E-2

7815

7815
15 11
6

7815

7810
C

7810

7815
7815

7815
31250
7815

7815
50
-21
SE
00-
903
.27
T NO

REFER TO SHEET
7815

7810
EE
SH

OUTBOUND OFFICE BUILDING GROUND FLOOR COLUMN LAYOUT


TO

207600
D FER
RE

7810

7815
1

NO.2790300-SE
7815

7810
-2120
31250
7815

7810
7815

7810
E

7810

7480
-
17 8
-21 11
SE E-2

7815

7815
00- 0-S
903 30
.27 90
.27

31250
T NO

1:100
NO
EE T
SH EE
TO SH

7815

7815
R TO
FE R
RE FE
RE

7815

7805
F

7500

7500
22500
7500

7500
7500

7500
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-21
30
Client:

ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER

Document No. OUTBOUND.DWG


SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct
Beca Pp h
ilp
in
iesLd
t. OUTBOUND OFFICE BUILDING STRUCTURAL
pneBisaP
rn(lch)i
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
GROUND FLOOR Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti COLUMN LAYOUT 2790300-SE-2340 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

www.beca.com
19 20 21 22

N1 N2 N3 N4
17700

3005 2995 2905 3095 2805 3195 2705


ALL PEB ITEMS - NOT PART OF SCOPE

ORIGINAL IN COLOUR
NA
c c c c

4525
A"

2675
NB c c c c

A' 3325
725

NC c c c c
22650

5700

ND c c c c
5700

NE
675

c c c c
A
2790300-SE-2341
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
T NO
.27
18800

18800
903
00-
12800

SE
-21
40
A

7500

7500
22500
7500

7500
7500

7500
B

7810

7815
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
.27 .27

31250
903 90
00- 30
SE 0-S
-21 E-2

7815

7815
15 11
6

7815

7810
C

7810

7815
7815

7815
31250
7815

7815
50
-21
SE
00-
903
.27
T NO

REFER TO SHEET
7815

7810
EE
SH

OUTBOUND OFFICE BUILDING SECOND FLOOR COLUMN LAYOUT


TO

207600
D FER
RE

7810

7815
1

NO.2790300-SE
7815

7810
-2120
31250
7815

7810
7815

7810
E

7810

7480
-
17 8
-21 11
SE E-2

7815

7815
00- 0-S
903 30
.27 90
.27

31250
T NO

1:100
NO
EE T
SH EE
TO SH

7815

7815
R TO
FE R
RE FE
RE

7815

7805
F

7500

7500
22500
7500

7500
7500

7500
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-21
30
Client:

ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER

Document No. OUTBOUND.DWG


SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct
Beca Pp h
ilp
in
iesLd
t. OUTBOUND OFFICE BUILDING STRUCTURAL
pneBisaP
rn(lch)i
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SECOND FLOOR Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti COLUMN LAYOUT 2790300-SE-2341 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

www.beca.com
19 20 21 22

N1 N2 N3 N4
17700

3005 2995 2905 3095 2805 3195 2705


ALL PEB ITEMS - NOT PART OF SCOPE

ORIGINAL IN COLOUR
NA

2350
4525
x (TYPICAL)

m (TYPICAL)
2325
A"

2675

2350
NB

2025
3325

2025
A'

725
NC

x x

3620
22650

5700

2080

ND
1905
5700

1890
1905

NE
675

A
2790300-SE-2342
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
T NO
.27
18800

18800
903
00-
12800

SE
-21
40
A

7500

7500
22500
7500

7500
7500

7500
B

7810

7815
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
.27 .27

31250
903 90
00- 30
SE 0-S
-21 E-2

7815

7815
15 11
6

7815

7810
C

7810

7815
7815

7815
31250
7815

7815
50
-21
SE
00-
903
.27
T NO

REFER TO SHEET
7815

7810
EE
SH

OUTBOUND OFFICE BUILDING SECOND FLOOR BEAM LAYOUT


TO

207600
D FER
RE

7810

7815
1

NO.2790300-SE
7815

7810
-2120
31250
7815

7810
7815

7810
E

7810

7480
-
17 8
-21 11
SE E-2

7815

7815
00- 0-S
903 30
.27 90
.27

31250
T NO

1:100
NO
EE T
SH EE
TO SH

7815

7815
R TO
FE R
RE FE
RE

7815

7805
F

7500

7500
22500
7500

7500
7500

7500
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-21
30
Client:

ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER

Document No. OUTBOUND.DWG


SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct
Beca Pp h
ilp
in
iesLd
t. OUTBOUND OFFICE BUILDING STRUCTURAL
pneBisaP
rn(lch)i
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SECOND FLOOR Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti BEAM LAYOUT 2790300-SE-2342 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

www.beca.com
19 20 21 22

N1 N2 N3 N4
17700

3005 2995 2905 3095


ALL PEB2805ITEMS - NOT
3195 2705
PART OF SCOPE

ORIGINAL IN COLOUR
za
NA

4525

m
LC 150X65X2.0mm
A" PURLINS SPACED
@ 1000mm O.C.

2675
u (TYP.)

x (TYPICAL)
NB
3325

A'
725

NC
22650

5700

ND
5700

za
NE
675

A
2790300-SE-2343
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200

RE
A"

FE
R
TO
6000

SH
EE
T NO
.27
18800

18800
903
00-
12800

SE
-21
40
A

7500

7500
22500
7500

7500
7500

7500
B

7810

7815
RE
RE FE
FE R
R TO TO
SH SH

7815

7815
EE EE
T NO T NO
.27 .27

31250
903 90
00- 30
SE 0-S
-21 E-2

7815

7815
15 11
6

7815

7810
C

7810

7815
7815

7815
31250
7815

7815
50
-21
SE
00-
903
.27
T NO

REFER TO SHEET
7815

7810
EE
SH

OUTBOUND OFFICE BUILDING ROOF FRAMING LAYOUT


TO

207600
D FER
RE

7810

7815
1

NO.2790300-SE
7815

7810
-2120
31250
7815

7810
7815

7810
E

7810

7480
-
17 8
-21 11
SE E-2

7815

7815
00- 0-S
903 30
.27 90
.27

31250
T NO

1:100
NO
EE T
SH EE
TO SH

7815

7815
R TO
FE R
RE FE
RE

7815

7805
F

7500

7500
22500
7500

7500
7500

7500
G

RE
12800

12800
FE
R
TO
18800

SH
EE
T NO
G'

.27
903
6000

00-
SE
G"

-21
30
Client:

ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER

Document No. OUTBOUND.DWG


SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct
Beca Pp h
ilp
in
iesLd
t. OUTBOUND OFFICE BUILDING STRUCTURAL
pneBisaP
rn(lch)i
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
ROOF FRAMING LAYOUT Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-2343 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
ARMOURED DOWELLED
EXPANSION JOINTS TYPICAL 3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.
AT DOOR OPENINGS (SJ) SAWN JOINTS TYPICAL
LOADING DOCK SLAB LOADING DOCK SLAB
T.O.C. R.L. 35.200m T.O.C. R.L. 35.200m
150 RC SLAB F'C = 40MPa WITH 150 RC SLAB F'C = 40MPa WITH
A'' TYPICAL CONSTRUCTION JOINTS
10mm REBARS @150mm C/C 10mm REBARS @150mm C/C
TOP BARS (BOTH WAYS)
TOP BARS (BOTH WAYS)

A'

www.beca.com
A
(ADCJ)
ARMOURED DOWELLED
CONSTRUCTION JOINTS
TYPICAL OUTBOUND STAGING AREA

ORIGINAL IN COLOUR
(DCJ)
DOWELLED
CONSTRUCTION
JOINTS

C
ISOLATION JOINT ALL
AROUND PEDESTALS
(TYPICAL)

INDICATIVE SPACE FOR RACKED AREA


AMBIENT WAREHOUSE

D
WAREHOUSE AMBIENT FLOOR
SLAB T.O.C. R.L. 35.200m 250 RC
SLAB f'c = 40MPa WITH 12MM REBARS
@ 150mm C/C TOP BARS (BOTH WAYS)
OR WELDED WIRE MESH AND 16MM
REBARS @100mm C/C BOTTOM BARS
(BOTH WAYS) OR WELDED WIRE MESH
W/ 25 BOTTOM COVER 0.3MM BURNISHED
BLACK POLYTHENE MEMBRANE.
BURNISHED FLOOR SLAB.

ISOLATION JOINT ALL INBOUND STAGING AREA INBOUND STAGING AREA


AROUND PEDESTALS
(TYPICAL)

G'
TOP BARS (BOTH WAYS) TOP BARS (BOTH WAYS)
TYPICAL CONSTRUCTION JOINTS
10mm REBARS @150mm C/C
G'' 150 RC SLAB F'C = 40MPa WITH
10mm REBARS @150mm C/C
150 RC SLAB F'C = 40MPa WITH
T.O.C. R.L. 35.200m Client:
T.O.C. R.L. 35.200m
LOADING DOCK SLAB LOADING DOCK SLAB

Document No. WAREHOUSE COLUMN LAYOUT.DWG


(SJ) SAWN JOINTS TYPICAL
AT DOOR OPENINGS
EXPANSION JOINTS TYPICAL
ORIGINAL DRAWING
ARMOURED DOWELLED
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

1 WAREHOUSE SLAB ON GRADE FOR TENDER


Project:

- 1:500 SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. MAIN WAREHOUSE STRUCTURAL
0 ISSUED FOR TENDER EFG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier FTF
Drg Check JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SLAB ON GRADE Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-2410 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.
42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10ALL9 PEB
8 ITEMS
7 6- NOT
5 PART
4 OF
3 SCOPE
2 1

MAIN WAREHOUSE ROOF


4470 REFER TO DWG. NO 2790300-SE- 2318

GL 1 TO 42
a (TYP.)
ze (TYP.) ze (TYP.) ze (TYP.)
18313
13843

v v v v DOCK AREA ROOF CANOPY

f (TYP.)

www.beca.com
REFER TO DWG. NO 2790300-SE- 2316
1300

1 ELEVATION @ GL. A
- 1:500

ORIGINAL IN COLOUR
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34
ALL PEB ITEMS - NOT PART OF SCOPE
35 36 37 38 39 40 41 42

MAIN WAREHOUSE ROOF


4470

REFER TO DWG. NO 2790300-SE- 2318


ze (TYP.) ze (TYP.) ze (TYP.)
18313
13843

v v v v DOCK AREA ROOF CANOPY


REFER TO DWG. NO 2790300-SE- 2316
1300

2 ELEVATION @ GL. G
- 1:500

A'' A' A B C D E ALL PEB ITEMS - NOTF PART OF SCOPE


G G' G''
s t t s s t t
t s s s t
4470

s s t t s s
s t t s
18313

GL 2 TO 41
a
13843

d (TYP.)

i i

a
f

f
1300

RETAINING WALL LINE

3 ELEVATION @ GL. 1
- 1:500

G'' G' G F E D C ALL PEB ITEMS - NOTBPART OF SCOPE


A A' A''
s t t s s t t
t s s t
4470

t s s t t s s
s t s
18313

d (TYP.)
a

p
13843

i i

a
i i
e
f

f
1300

Client:

ELEVATION @ GL. 42

Document No. WAREHOUSE COLUMN LAYOUT.DWG


4 ORIGINAL DRAWING
- 1:500 IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER SOLID LF


NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. MAIN WAREHOUSE STRUCTURAL
0 ISSUED FOR TENDER EFG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier FTF
Drg Check JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
ELEVATIONS Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-2510 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
ALL PEB ITEMS - NOT PART OF SCOPE
r
ze (TYP.) ze (TYP.) ze (TYP.)

GL 1 TO 42
a (TYP.)
13843 v (TYP.)

www.beca.com
1300

SF-2 SF-2 SF-2

1 SECTION @ GL. A
SE-2311/2312 1:500

ORIGINAL IN COLOUR
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 42
ALL PEB ITEMS - NOT PART OF SCOPE
r
GL 2 TO 41
c (TYP.)
15037

d
1300

2 SECTION @ GL. B
SE-2311/2312 1:500

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 ALL PEB
35 ITEMS37- NOT PART
39 OF SCOPE
41 42
r
GL 2 TO 41
16675

c (TYP.)
d

d
1300

SECTION 3
3 SECTION @ GL. C & E
SE-2311/2312 1:500

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33ALL PEB
35ITEMS 37 39 OF SCOPE
- NOT PART 41 42
r
GL 2 TO 41
b (TYP.)
18313

d
1300

Client:

SECTION @ GL. D

Document No. WAREHOUSE COLUMN LAYOUT.DWG


4 ORIGINAL DRAWING
SE-2311/2312 1:500 IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER SOLID LF


NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. MAIN WAREHOUSE STRUCTURAL
0 ISSUED FOR TENDER EFG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier FTF
Drg Check JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SECTIONS Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti SHEET 1 OF 2 2790300-SE-2511 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 42
ALL PEB ITEMS - NOT PART OF SCOPE
r

GL 2 TO 41
c (TYP.)
p (TYP.)

15037
d

(TYP.)

www.beca.com
e

1300
5 SECTION @ GL. F
SE-2313/2314 1:500

ORIGINAL IN COLOUR
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
ALL PEB ITEMS - NOT PART OF SCOPE
r
ze (TYP.) ze (TYP.) ze (TYP.)
GL 1 TO 42
a (TYP.)
13843

v (TYP.)

(TYP.)
e
1300

SF-1 SF-1 SF-1

6 SECTION @ GL. G
SE-2313/2314 1:500

G'' G' G F E D C B A A' A''


ALL PEB ITEMS - NOT PART OF SCOPE
s t t s s t t
t s s s t
4470

t s s t t s s t
s s
18313

b
13843

a
c

c
i i
a
f

f
1300

nEpAIjIjG sAhh nEpAIjIjG sAhh

7 SECTION @ GL. 8 (TYP. FOR GL. 2 TO 10)


SE-2311/2313 1:500

G'' G' G F E D C B A A' A''


ALL PEB ITEMS - NOT PART OF SCOPE
s t t s s t t
t s s s t
4470

t s s t t s s
s t s
18313

p
13843

a
c

c
i i
e

e
f

f
1300

nEpAIjIjG sAhh nEpAIjIjG sAhh

Client:

8 SECTION @ GL. 13 (TYP. FOR GL. 11 TO 41)

Document No. WAREHOUSE COLUMN LAYOUT.DWG


ORIGINAL DRAWING
SE-2311/2312 1:500
SE-2313/2314 IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER SOLID LF


NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. MAIN WAREHOUSE STRUCTURAL
0 ISSUED FOR TENDER EFG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier FTF
Drg Check JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SECTIONS Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti SHEET 2 OF 2 2790300-SE-2512 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

www.beca.com
ORIGINAL IN COLOUR
FA
VD RF RE RD RC RB RA FP FN FL FK FJ FH FF FE FC EO EN EM EL EK EJ EI EH EG EF EE ED EC EB EA

ALL PEB ITEMS - NOT PART OF SCOPE

500 X 500 R.C.


y
ALL PEB ITEMS - NOT PART OF SCOPE y

TYPICAL
4930

c (TYPICAL)
n n
453
14175

RB

c
p
9245

j
8792

w
w

7720
j

B
1300

DESIGN ON HOLD
1 ELEVATION @ GL. E3
SE-2520 1:250

E1 E2 E3

ALL PEB ITEMS - NOT PART OF SCOPE


m
12145

p
1300

2 ELEVATION @ GL. EO
SE-2520 1:250
Client:

ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

Document No. MAIN OFFICE.DWG


FOR TENDER SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct pneBisaP
Beca Pp
rn(lch)i
h
ilp
in
iesLd
t. OFFICE & AMENITIES, GENSET, STRUCTURAL
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
MATERIALS RECYLCING FACILITY Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti ELEVATIONS 2790300-SE-2520 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

www.beca.com
ORIGINAL IN COLOUR
FA
VD RF RE RD RC RB RA FP FN FL FK FJ FH FF FE FC EO EN EM EL EK EJ EI EH EG EF EE ED EC EB EA

ALL PEB ITEMS - NOT PART OF SCOPE

500 X 500 R.C.


y
ALL PEB ITEMS - NOT PART OF SCOPE

3200
y

TYPICAL
y

n n
453

c (TYPICAL)

14175
RB

10975
c
j

p
9245
8792

w
j

7720

c
B
1300

1300
DESIGN ON HOLD 1 SECTION @ GL E2
SE-2521 1:250

E1 E2 E3

ALL PEB ITEMS - NOT PART OF SCOPE


x
VARIES

2 SECTION @ GL EF
SE-2521 1:250

Client:

ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

Document No. MAIN OFFICE.DWG


FOR TENDER SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct
Beca Pp h
ilp
in
iesLd
t. OFFICE & AMENITIES, GENSET, STRUCTURAL
pneBisaP
rn(lch)i
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
MATERIALS RECYLCING FACILITY Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti SECTIONS 2790300-SE-2521 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

www.beca.com
S1 S2 S3 S4 SE SD SC SB SA

ALL PEB ITEMS - NOT PART OF SCOPE ALL PEB ITEMS - NOT PART OF SCOPE

ORIGINAL IN COLOUR
za za

za

za
za

q
2420
2665

za

za

x x
16365

16365

13945
13700

c
x x
1300

1300
1 ELEVATION @ GL SE 2 ELEVATION @ GL S4
- 1:100 - 1:100

Client:

ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER SOLID LF

Document No. INBOUND.DWG


NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct
Beca Pp h
ilp
in
iesLd
t. INBOUND OFFICE BUILDING STRUCTURAL
pneBisaP
rn(lch)i
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
ELEVATIONS Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-2530 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

www.beca.com
S1 S2 S3 S4 SA SB SC SD SE

ALL PEB ITEMS - NOT PART OF SCOPE

ORIGINAL IN COLOUR
ALL PEB ITEMS - NOT PART OF SCOPE

za
za za
2665

1220
za

za
za

q
za

x x
16365

15165
13945
13700

c
x x
1300

1300
1 SECTION @ GL SD 2 SECTION @ GL S3
SE-2330 1:100 SE-2330 1:100

Client:

ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER SOLID LF

Document No. INBOUND.DWG


NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct
Beca Pp h
ilp
in
iesLd
t. INBOUND OFFICE BUILDING STRUCTURAL
pneBisaP
rn(lch)i
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SECTIONS Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-2531 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

www.beca.com
ORIGINAL IN COLOUR
N1 N2 N3 N4 NE ND NC NB NA
ALL PEB ITEMS - NOT PART OF SCOPE
ALL PEB ITEMS - NOT PART OF SCOPE
LC 150X65X2.0mm
LC 150X65X2.0mm PURLINS SPACED
PURLINS SPACED @ 1000mm O.C.
@ 1000mm O.C.
2520

za

2650

x
za
c

c
12035

12035
9515

x x

9385

9385
1300

1300
1 ELEVATION @ GL NA 2 ELEVATION @ GL N4
- 1:100 - 1:100

Client:

ORIGINAL DRAWING
IN COLOUR PRECOn
S
Ic,. Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER

Document No. OUTBOUND.DWG


SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsrtuct
Beca Ph p
ilipn
iesLd
t. OUTBOUND OFFICE BUILDING STRUCTURAL
pnpeiB
P s(alrnhcih)
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
223C
ooM efck,anodvgB
1nhR
elilui
oioceAsvenue
BU&tnC
HouR
iB4W
osS
4aconrer
nta.tnchE
o3eas,t
L3R eFve,G
lc1pa9uB
Sceadl,LS
sid6lb,gl.
no.ertnM zo,akiat
ELEVATIONS Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pnpei1P


sM
2l3yhC
,3itaikat pnpei1P
s8M
ln1yhC
,ak1itair pnpei1P
s2l2yhC
,3iti 2790300-SE-2540 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

NOTES:
1. FOR GENERAL NOTES REFER TO SHEET NO. 2790300-SE-0200.
2. FOR FOOTING SCHEDULE REFER TO SHEET 2790300-SE-3110.
3. FOR LEGEND OF STRUCTURAL MEMBERS REFER TO SHEET 2790300-SE-3111.

www.beca.com
ORIGINAL IN COLOUR
N1 N2 N3 - NOT PART OF SCOPE
ALL PEB ITEMS N4 NA NB NC ND NE
LC 150X65X2.0mm
ALL PEB ITEMS - NOT PART OF SCOPE
PURLINS SPACED
@ 1000mm O.C.
2520

za za
za
c

c
12035

10680
9515

x x x

9610
1300

1 SECTION 1 @ GL NB 1300 2 SECTION 2 @ GL N3


2340 1:100 2340 1:100

Client:

ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER

Document No. OUTBOUND.DWG


SOLID LF
NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct
Beca Pp h
ilp
in
iesLd
t. OUTBOUND OFFICE BUILDING STRUCTURAL
pneBisaP
rn(lch)i
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
SECTIONS Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-2541 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

UNDER REVIEW

MAIN WAREHOUSE FOOTINGS MAIN OFFICE AND AMENITIES FOOTINGS

www.beca.com
MARK T L W BAR X BAR Y QUANTITY MARK T L W BAR X BAR Y QUANTITY
F1 600 4500 4500 26-Ø20 26-Ø20 16 F11 400 3200 3200 18-Ø20 18-Ø20 12
F2 500 3500 3300 19-Ø20 19-Ø20 71 F12 350 2600 2600 13-Ø20 13-Ø20 20
F3 400 3000 3000 18-Ø20 18-Ø20 42 F13 300 2000 2000 13-Ø16 13-Ø16 4
F4 400 2800 2800 16-Ø20 16-Ø20 30 F14 400 3000 3000 15-Ø20 15-Ø20 26
F5 400 2500 2500 13-Ø20 13-Ø20 25 F15 600 4000 5000 - - 3
F6 300 2000 2000 14-Ø16 14-Ø16 17 CF-14 600 4600 3200 - - 1
CF-1 600 3000 2600 - - 2 CF-15 600 3500 3500 - - 1

ORIGINAL IN COLOUR
CF-2 600 3000 6680 - - 1 CF-16 600 3000 3000 - - 2
CF-3 600 3000 4965 - - 1
CF-4 600 5000 4700 - - 1
CF-5 600 3000 3500 - - 1
CF-6 600 3000 3650 - - 2
CF-7 600 3000 4295 - - 1
CF-8 600 3000 5065 - - 1
CF-9 600 3000 2940 - - 1
CF-10 600 3650 4015 - - 1
CF-11 600 3650 4935 - -
INBOUND OFFICE BUILDING FOOTINGS
1
CF-12 600 3815 3000 - - 1 MARK T L W BAR X BAR Y QUANTITY
CF-13 600 3710 3500 22-Ø20 22-Ø20 F21 400 3200 3200 18-Ø20 18-Ø20 3
16
F22 400 2800 2800 13-Ø20 13-Ø20 3
F23 350 2400 2400 11-Ø20 11-Ø20 7
F24 300 2000 2000 13-Ø16 13-Ø16 3

MAIN WAREHOUSE PEDESTALS


MARK T L W BAR X BAR Y QUANTITY
P1 1500 800 815 - - 87
P2 1500 610 930 - - 42 OUTBOUND OFFICE BUILDING
P3 1500 660 750 - - 77
1310 MARK T L W BAR X BAR Y QUANTITY
750

P4 1500 - -
1425

590
31 F31 350 2400 2400 11-Ø20 11-Ø20 6
675

700
F32 300 2000 2000 13-Ø16 13-Ø16 6
P5 1500 800 1425 - - 56
800 F33 300 1800 1800 10-Ø16 10-Ø16 4
630
815

P6 1500 650 510 - - 15


750
570

660

P7 1500 800 1380 - - 1


P8 1500 1560 1425 - - 1

Document No. WAREHOUSE FOUNDATION LAYOUT LATEST.DWG


Client:

ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER SOLID LF


Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 17-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 17-05-2022
-
DEQA
Desg inCoalboravite
PRM
Desg
I ETEKTON
inandConsru
tct
Beca Pp h
ilp
in
iesLd
t. FOUNDATION SCHEDULE STRUCTURAL
pneBisaP
rn(lch)i
0 ISSUED FOR TENDER FG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier
Drg Check
FTF
JJ
22-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD
23C
oM efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouSsnat.chE
3oea,st
RL31eFG
9vca6e,B
ScaeL,ndoelS
dpslguil.bl
M.rnzto,akiat
AND PEDESTALS Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1is2P


3lhM
y,iC
taikat pne1is8P
1lhyM
n,iCatkiair pne1is2Pl3hy,iC ti 2790300-SE-3100 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

MAIN WAREHOUSE COLUMNS MAIN OFFICE AND AMENITIES COLUMNS INBOUND OFFICE BUILDING COLUMNS OUTBOUND OFFICE BUILDING COLUMNS
C1 - ( a - W40X321 ) C11 - ( c - W14X159 ) C21 - ( c - W14X159 ) C31 - ( c - W14X159 )
C2 - ( b - W14X283 ) C12 - ( 500X550 / BAR X- / BAR Y- ) m W18X60 (460UB82) m W18X60 (460UB82)

www.beca.com
C3 - ( c - W14X159 ) C13 - ( j - W24X84 (610UB125) ) q W24X76 PRIMARY BEAMS u L5XL5X3/8
C4 - ( d - W16X100 ) C14 - ( w - W14X38 (360UB56.7) ) u L5XL5X3/8 x W16X36
C5 - ( e - W14X172 ) C15 - ( - ) x W16X36 za W21X73 (530UB92)
C6 - ( f - W21X55 ) k L4X4X3/8 (100X100X10EA) za W21X73 (530UB92)
i W16X45 (410UB60) l W10X19 (250UB31.4)
l W10X19 (250UB31.4) m W18X60 (460UB82)
m W18X60 (460UB82) n HSS8X8X1/2 (200X200X12.5 SHS)
n HSS8X8X1/2 (200X200X12.5 SHS) p W16X40 SECONDARY BEAMS

ORIGINAL IN COLOUR
p W16X40 SECONDARY BEAMS q W24X76 PRIMARY BEAMS
q W24X76 PRIMARY BEAMS y W21X73 (530UB92)
r W30X191 TRANSFER BEAM za W21X73 (530UB92)
s W40X397 zb W18X55 (460UB82)
t W30X173 zc W10X26 (250UB37)
u L5XL5X3/8 zd W10X60 (250UC90)
v L8XL8X9/8
ze H8T8T9/8

ALL PEB ITEMS - NOT PART OF SCOPE

Client:

Document No. WAREHOUSE COLUMN LAYOUT.DWG


ORIGINAL DRAWING
IN COLOUR PRECO
nIS
c., Green Sun (formerly Solid House), 2285 Don
Chino Roces Avenue Extension, 1231 Makati City, Philippines

Project:

FOR TENDER SOLID LF


NOT FOR CONSTRUCTION Solid Integrated Logistics Facility
CALAMBA, LAGUNA, PHILIPPINES
Original Design JA 19-05-2022 Approved For: Architects and Engineers: Project Managers, Architecture and Engineering Consultants: Title: Discipline:
Scale (A1)
- Drawn EFG 19-05-2022
-
DEQA
Desg inCo loravite
alb
PRM
Desg
I ETEKTON
inandConsru
tct pisaP
Beca Pp h
ilp
in
iesLd
t. SCHEDULE OF STRUCTURAL
pneB rn(lch)i
0 ISSUED FOR TENDER EFG FF JG 26-05-2022
Reduced
Scale (A3)
Dsg Verifier FTF
Drg Check JJ
24-05-2022
26-05-2022 Date: -
ENGINEERING MANAGEMENT SUSTAINABILITY RD oM
223C
efnckadg,ovB
1nR
ielui
hoioceAsvenue
BU
HR
&tnC iB4Waconre
ouoS
snat.ntchE
3oea,st
R 9vca6e,B
L31eFG dpslguil.bl
SScaeL,nadoelS M.rnozto,akiat
STRUCTURAL MEMBERS Drawing No.: Beca Project Number: 2790300 Rev.

No. Revision By Chk Appd Date - pne1pis2P


3l3hM taikiat
y,iC pne1pis8P
1l1hyM atkiiar
n,iC pne1pis2P2l3hy,iC ti 2790300-SE-3111 0

DO NOT SCALE FOR SET OUT DIMENSIONS IF IN DOUBT ASK.


Drawing Plotted: 15/10/2021 9:23:51 AM

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
246880
6200 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6480 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6000 6200
3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3445 3035 5935 65 3025 2980 3020 3000 3020 3000 3020 3000 3020 3000 3020 3000 3020 3000 3020 3000

C3-F11 C3-F11 C3-F11 C3-F11

RE
A"

FE
R
TO
C5-F5 C5-F5

6000

SH
C3-F10 C3-F9 C3-F9 C3-F10

EE
TN
O.
C3-F10 C3-F11 C3-F10
C5-F5 C5-F5 C5-F5 C5-F5 C5-F5 C5-F5 C5-F5 C5-F5 C5-F5 C5-F5 C5-F5 C5-F5 C5-F5 C5-F5 C5-F5 C5-F5 C5-F5 C5-F5

27
C3-F10 C3-F9 C3-F9 C3-F10

18800

18800
90
30
0-S
12800

E-
21
C3-F10 C3-F9 C3-F9 C3-F10

40
C3-F7 C1-F1 C3-F7

www.beca.com
A SF-2 SF-2
C3-F11 C3-F10 C3-F10 C3-F11
SF-2 SF-2
C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1
7500

7500
C3-F10 C3-F4 C3-F7

C2
C2
C3-F10 C3-F10
22500

C3-P1-F1
7500

7500
C2
CF-1 C3-F4 C3-F7

C2-F8 C2-F8
7500

7500
C3-F7 C3-F4 C3-F7
B
C2-F8 C2-F8
C3-P1-F1 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C3-P1-F1
7810

7815
RE C3-F7 C3-F4 C3-F7
RE FE
FE R
RT TO
C2-F8 O C2-F8
SH SH

ORIGINAL IN COLOUR
7815

7815
EE EE
TN TN
O. O.
27 27 C3-F7 C3-F4 C3-F7
31250

90 90
30 30
0-S 0-S
C2-F8 E C2-F8
-21 E-
21
7815

7815
10 11
C3-F7 C3-F4 C3-F7

C2-F8 C2-F8
7815

7810
C3-F7 C3-F4 C3-F7
C
C2-F8 C2-F8
C3-P1-F1 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C--F-
7810

7815
C3-F7 C3-F4 C3-F7
C2-F8 C2-F8
7815

7815
C3
31250

C3-F4 C3-F7
C2
C2-F8
C3
7815

7815
CF-2 C3-F10
50
C3
E-21
C3-F7 00-S
C3-F4 03
C2
.279
C2-F8 CF-3
NO

REFER TO SH
T
7815

7810
EE
O SH
C3 C3 C3
RT
207600

D C2 C2 C2 FE
C1 C3-P1-F5
RE
CF-22 CF-6

EET NO.27903
C3-P1-F1 C3-P1-F1 C3-P1-F1 C3-P1-F1 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C2-F3 C3-P1-F1 C3-P1-F1 C3-P1-F1 CF-21
7810

7815
C3-P1-F5 C3-P1-F5
C2
C2-F8 C2

00-SE-2120
7815

7810
CF-20 C3-P1-F5
31250

C2
C2CF-19 C3-P1-F5 C3-P1-F5 C3-P1-F5
C2-F8
7815

7810
C3-P1-F5 C3-P1-F5 C3-P1-F5 C3-P1-F5

C2
C2-F8
C2
7815

7810
CF-19 C3-P1-F5

C2
E
C2
C2-F8

You might also like