You are on page 1of 2

Certificate No.

-IEC/L&T/RRTS-P7/24/LT-173

REPORT OF EXAMINATION OF LIFTING MACHINE/TACKLE

1. Name of Owner M/s L&T

2. Address of Site RRTS P7, Shatabdi Nagar, Meerut, UP

3.Distinguishing number or mark if LAUNCHING GIRDER HOIST of LG-5 - Make : NANTONGLIWET - Model JT7 -
any and description sufficient to Original Max. SWL cap. 70 MT. Present max. SWL Cap. 65 MT in 12 parts (6 x 2) of rope
22 mm dia. Sl. Nos. 20110094, 20110095 - Mfd. 2020. Checked between Pier nos. 1504
identify the lifting machine, chain , and 1505, Dorli, Meerut, UP.
rope or tackle

4. Date when the lifting Machine,


chain rope or tackle was first As per owner's record
taken into use at site

5. Details of certificate relating to As per Manufacturers T.C.


tests and examinations by
manufacturer

6. Date of last periodical thorough 16th August 2023, by us at other location


examination made and by whom
carried out
7. Date of annealing or other Heat Not Applicable
treatment)

8. Particulars of any defects MAIN HOIST tested on a max. available load of 80.5 MT which it lifted, lowered and
affecting the safe working load travelled satisfactorily. This Certificate pertains to the hoist only and not to the
launching structure.
found at current examination and
the steps to remedy the defects

It is certified that on 9th March 2024 this Lifting Machine/Tackle was thoroughly examined and the above is
a correct report of the result

Next Inspection Due : 9th September 2024

Subject to DISCLAIMER below.


VARUN BHILOTRA
B.Tech. (Mech.)
“COMPETENT PERSON”

DISCLAIMER: This Report of examination reflects the condition of the machine/ equipment as on date. We accept no
liability / responsibility whatsoever in case of any accident / mishap on/with/ due to this machine / equipment
Certificate No.-IEC/L&T/RRTS-P7/24/LT-174

REPORT OF EXAMINATION OF LIFTING MACHINE/TACKLE

1. Name of Owner M/s L&T

2. Address of Site RRTS P7, Shatabdi Nagar, Meerut, UP

3.Distinguishing number or mark if LIFTER BEAM - 3000 mm (end to end) x 300 mm - SWL cap 70 MT as per L&T. ID No
any and description sufficient to LG-5. Checked between Pier nos. 1504 and 1505, Dorli, Meerut, UP.
identify the lifting machine, chain ,
rope or tackle

4. Date when the lifting Machine,


chain rope or tackle was first As per owner's record
taken into use at site

5. Details of certificate relating to As per Manufacturers T.C.


tests and examinations by
manufacturer

6. Date of last periodical thorough 18th August 2023, by us at other location


examination made and by whom
carried out
7. Date of annealing or other Heat Not Applicable
treatment)

8. Particulars of any defects No defects found on physical test. & load test of 79.5 MT.
affecting the safe working load
found at current examination and
the steps to remedy the defects

It is certified that on 9th March 2024 this Lifting Machine/Tackle was thoroughly examined and the above is
a correct report of the result

Next Inspection Due : 9th September 2024

Subject to DISCLAIMER below.


VARUN BHILOTRA
B.Tech. (Mech.)
“COMPETENT PERSON”

DISCLAIMER: This Report of examination reflects the condition of the machine/ equipment as on date. We accept no
liability / responsibility whatsoever in case of any accident / mishap on/with/ due to this machine / equipment