Professional Documents
Culture Documents
ConnectKey Devices
1. Go To WebUI > Support > Remote Control Panel > Edit > For Admin and Diagnostics Users Only > Save.
2. Click Logout twice, then click again Login and enter diag + 3424 + Login.
3. Click Remote Control Panel tab > Open Remote Control Panel button. Remote Desktop is displayed.
If old SW version with Java: Click Next + Run on Java Security screens. Overview p. 1
4. Hit Service Diagnostics button + [Enter] Diagnostic Service Access code (in Manual Guide/Global Procedure GP1).
5. When diagnostics actions are completed, click Call Closeout + the appropriate Exit mode.
Altalink Devices
1. Go to Device Web UI > Support tab > Remote Control Panel > Edit > For Admin and Diagnostics Users Only > Save.
Then click Start Remote Session.
2. Click & hold down 5 sec at least the Home button, then release it.
3. Type the Diagnostic Service Access code (in Manual Guide/Global Procedure GP1) + OK.
At least 5 secs,
then release it.
4. When diagnostic actions are completed, click Call Closeout + the appropriate Exit mode.
Versalink Devices
1. Logon to device Web UI > Home Page > Remote Control Panel icon in bottom.
2. Select Enable + Lock device Control Panel, then click Request Session.
3. Click & hold down 5 sec at least the Home button, then release it.
4. Type the Diagnostic Service Access code (in Manual Guide/Global Procedure GP1) + Enter or OK.
At least 5 secs,
then release it.
6. When diagnostic actions are completed, click Exit + Log History cleaning mode.
7. Click Services + Call closeout to exit diagnostic mode with appropriate mode.