Form 4D microprocessor-based
recloser control and accessories
Description
Eaton’s Cooper Power™ series Form 4D recloser
control is the first in a line of fully integrated controls.
These controls will feature a standard look
and feel, and a universal platform that can be
programmed for almost any protective application.
This means one standard operating system and
front panel to train field technicians on. That
translates to fewer training expenses, reduced
inventory, and a distribution system that is much
easier to maintain.
In addition to the flexible and user-friendly
platform, the new controls will have the
communications technology to take your system
into the future. With fully modular communication
compatibility, these controls will support cellular
and radio communications utilizing the DNP3 and
other serial and network protocols. Side panel
RS-232, fiber-optic, Ethernet, and RS-485 ports
are available for connection to SCADA or other
devices. These ports are accessed by swinging the
control panel forward.
The Form 4D recloser control provides phase and
ground current sensing, and three-phase voltage
sensing. The Form 4D control can compute power,
energy, power factor, and power flow direction
from these current and voltage inputs.
The standardized front panel of the Form 4D
control can be used to program and interrogate
the control, as well as to display metering and
alarm information. Control parameters can also
be programmed via personal computer using
ProView® NXG interface software. Temporary
connection to the control can be made through
the front panel USB port. The ProView NXG
interface software includes the functionality to
create and modify time-current curves (TCCs),
and provides diagnostic information. The Form 4D
control analysis tools include event recording, data
profiling, and various metering capabilities.
Catalog Data CA280009EN Form 4D microprocessor-based recloser control and accessories
Effective May 2017
Ordering information • From Table 2, specify the catalog number that describes the
required control cable.
To order a basic Form 4D microprocessor-based recloser control:
• From Tables 3 through 11, specify the catalog numbers that
• From Table 1, construct a catalog number that describes the describe the required accessories.
required control.
2 www.eaton.com/cooperpowerseries
Form 4D microprocessor-based recloser control and accessories Catalog Data CA280009EN
Effective May 2017
For Types WE, WVE27, WVE38X, VWE, VWVE27, VWVE38X, AC-NOVA15, AC-NOVA27A, AC-NOVA38A
Control cable, 18 gauge, Select from up to 79 feet. (Replace “X” with desired cable length.) KA1ME-X
Control cable, 16 gauge, Select from 80 to 125 feet. (Replace “X” with desired cable length.) KA18ME-X
Control cable, 14 gauge, Select from 126 to 200 feet. (Replace “X” with desired cable length.) KA35ME-X
For Types VSA12, VSA12B, VSA16, VSA20, VSA20A, VSO12, VSO16
Control cable, 18 gauge, Select from 11 to 20 feet. (Replace “X” with desired cable length.) KA1ME-X
Control cable, 16 gauge, Select from 21 to 35 feet. (Replace “X” with desired cable length.) KA18ME-X
Control cable, 14 gauge, Select from 36 to 50 feet. (Replace “X” with desired cable length.) KA35ME-X
For Types DC-NOVA15A, DC-NOVA27A, DC-NOVA38A (control-powered NOVA reclosers)
Control cable, 16 gauge, Select from 11 to 125 feet. (Replace “X” with desired cable length.) KA1119R6-X
AC input receptacles
120 Vac or 240 Vac input receptacle, 2-pin KME4D-1775-H
120 Vac input receptacle, 3-pin KME4D-1775-J
240 Vac input receptacle, 3-pin KME4D-1775-K
Low-voltage closing receptacles*
120 Vac low-voltage closing 2-pin input and 2-pin output receptacles KME4D-1775-A
120 Vac low-voltage closing with 3-pin input and 2-pin output receptacles KME4D-1775-B
120 Vac low-voltage closing with inlet hole and 2-pin output receptacle KME4D-1775-C
240 Vac low-voltage closing with 2-pin input and 2-pin output receptacles KME4D-1775-D
240 Vac low-voltage closing with 3-pin input and 2-pin output receptacles KME4D-1775-E
240 Vac low-voltage closing, for 2 wire with inlet hole and 2-pin output receptacle KME4D-1775-F
240 Vac low-voltage closing, for 3 wire with inlet hole and 2-pin output receptacle KME4D-1775-G
*Low-voltage closing receptacles are only applicable to control usage “A”. Refer to Table 1.
www.eaton.com/cooperpowerseries 3
Catalog Data CA280009EN Form 4D microprocessor-based recloser control and accessories
Effective May 2017
AC input cables
Input cable, 120 or 240 Vac, two-wire for 2-pin input, for use with KME4D-1775-H, A or D receptacles.
Replace “X” with desired length. Select from 10 to 80 feet.
Input cable, 240 Vac, three-wire for 3-pin input, for use with KME4D-1775-K or E receptacles.
Replace “X” with desired length. Select from 10 to 80 feet. KA11ME1-X
Input cable, 120 Vac, three-wire for 3-pin input, for use with KME4D-1775-J or B receptacles. KME4-67-2-X
Replace “X” with desired length. Select from 10 to 80 feet. KME4-67-3-X
Low-voltage closing cables
Low-voltage closing cable, 2-wire, for use with KME4D-1775-A, B, C, D, E, F, or G receptacles.
Replace “X” with desired length. Select from 10 to 80 feet . KA13ME1-X
NNote: The internal voltage sensing cable (KA97ME) is ordered with the recloser. If a replacement cable is required, contact your Eaton representative.
4 www.eaton.com/cooperpowerseries
Form 4D microprocessor-based recloser control and accessories Catalog Data CA280009EN
Effective May 2017
PROVISIONS FOR
UP TO 5/8" 1.13 LIFTING
MOUNTING HARDWARE. LUG
15.07
1.45
QUARTER TURN
LATCH WITH
PADLOCK 18.00
20.19 PROVISIONS 21.94
(.295-.394”
SHACKLE
DIAMETER)
www.eaton.com/cooperpowerseries 5
Catalog Data CA280009EN Form 4D microprocessor-based recloser control and accessories
Effective May 2017
The Form 4D control offers flexible phase and ground overcurrent Voltage protection
protection which can be programmed with up to four operations-
to-lockout. Each time-current curve (TCC) can be individually The Form 4D control includes three levels each of over- and
programmed from up to fifty standard curves which can be undervoltage protection and includes single-phase and three-
further customized. Time-current curves are available for fast and phase protection for both over- and undervoltage conditions. Both
delayed operations. The time-current curves are also selectable functions include a phase pickup, a phase time delay, a three-phase
from a graphical TCC editor to visualize any modifications prior to pickup, and three-phase time delay. One overvoltage and one
configuring the control. Reclose intervals and reset time can also be undervoltage alarm is also provided.
programmed by the user.
Frequency protection
TCC editor II Six levels of frequency protection are included with the control, with
Coordination and actual time current modifications are available each level configurable as either overfrequency or underfrequency.
with a graphic, interactive TCC editor. The TCC Editor II includes A frequency restoration function, which can be enabled or disabled,
a complete database of standard recloser industry time current will allow the recloser to automatically close should the frequency
curves, both ANSI® and IEC types, along with the ability to return to within configured settings for a user-settable time.
customize the TCCs with multipliers, constant time adders, or
Sync check
minimum response time adders. The user is also able to derive their
own specific TCC through data point entry. The Form 4D control includes sync check functionality, which is used
to qualify any close signal to the recloser when enabled via the sync
Sensitive earth fault check settings. Sync check allows for closing for any combination of
The Form 4D control includes Sensitive Earth Fault (SEF) protection, dead/live bus/line, and to perform anticipatory closing for a live bus/
which will provide tripping of the recloser for ground currents live line condition by calculating slip and anticipating the mechanism
below normal ground minimum trip elements. The SEF feature closing delay. In addition to the anticipatory close calculation, the
has programmable operations-to-lockout and reclose intervals sync check system performs verification of line and bus voltage
independent of the ground settings and is independently selectable magnitudes and frequencies to determine that they are within pre-
for each protection profile. determined ranges, and that the angular differences between the
two systems is also within the pre-determined range.
High current lockout
Sequence coordination
The High Current Lockout (HCL) feature will automatically lockout
the control when the current exceeds a programmed threshold. The The Form 4D control Sequence Coordination feature will allow
active number of operations-to-lockout is selectable for both phase the control to step through selected operations in the operating
and ground and is independently selectable for each protection sequence without tripping when a down-line recloser is proceeding
profile. through its reclose sequence. The number of advances is
programmable from one to three operations to provide trip
Cold load pickup coordination with the down-line recloser.
6 www.eaton.com/cooperpowerseries
Form 4D microprocessor-based recloser control and accessories Catalog Data CA280009EN
Effective May 2017
www.eaton.com/cooperpowerseries 7
Catalog Data CA280009EN Form 4D microprocessor-based recloser control and accessories
Effective May 2017
Communications
The Form 4D pole mount control is equipped with two
communication board accessory expansion bays offering
versatile support for modern communication media. Five distinct
communication options are available, providing two-way, real time
digital communications with a remote terminal unit (RTU), wireless,
telephone modem, Ethernet network, or other communication
devices. Any combination of two communication boards can be
installed. The following options are available:
• RS-232 (isolated) Serial communication card
• RS-485 (isolated) Serial communication card
• Fiber-optic-based Serial communication card with ST Connectors Ethernet Fiber, ST Ethernet Copper, RJ-45
• 10/100 Base-T/TX Ethernet communication card with RJ-45
connector
• 100 Base-FX Ethernet communication card with Ethernet Fiber,
ST Connector (multi-mode)
• 100 Base-FX Ethernet communication card with Ethernet Fiber,
MTRJ connector (multi-mode)
• 100 Base-FX Ethernet communication card with Ethernet Fiber,
SC connector (multi-mode)
• 100 Base-FX Ethernet communication card with Ethernet Fiber,
LC connector (single-mode)
The expansion bay based Communication Board Accessory concept
offers high versatility with respect to communication medium and
protocol support. Additional accessories are being continuously Ethernet Fiber, MTRJ Serial, RS-232
developed. Contact your Eaton representative for the latest
information regarding particular media and communication protocol
support.
8 www.eaton.com/cooperpowerseries
Form 4D microprocessor-based recloser control and accessories Catalog Data CA280009EN
Effective May 2017
COOPER POWER
SERIES
www.eaton.com/cooperpowerseries 9
Catalog Data CA280009EN Form 4D microprocessor-based recloser control and accessories
Effective May 2017
• ABOVE MIN TRIP: This LED illuminates when the control detects These LED indicators illuminate when the control detects the
that current is above the programmed minimum trip value for presence of voltage greater than the “V present” setting on the
Bushings 1-2, Bushings 3-4, Bushings 5-6, Ground or Sensitive System Configuration dialog. The LED will go out if the voltage
Ground. PHASE FAULT ALARM
on that phase is less than 95% of the “V present” setting.
• LOCKOUT: This LED illuminates to indicate the control is in a
A B C
locked out state, i.e. a reclosing sequence is not in progress. This CONTROL OK
LED does not indicate that the recloser is open.
PHASE FAULT
• GROUND FAULT
OPEN: This LED illuminates to indicate the recloser is in the open ACALARM
POWER
position. A B C CONTROL OK
• CLOSED: This LED illuminates to indicate the recloser is in the
SENSITIVE GND BATTERY
GROUND
closed position. The LED will blink when aFAULT
delayed CLOSE is AC POWER
active. A Close will occur when the manual close delay timer
expires. BATTERY
FREQUENCY TRIP
SENSITIVE GND
PHASE VOLTAGE
ENTER
FREQUENCY TRIP
VOLTAGE TRIP
PHASE FAULT ENTER ALARM APHASEBVOLTAGE
C
A B VOLTAGE
C TRIP CONTROL OK A B C
ABOVE MIN TRIP ESC EDIT X Y Z
GROUND ABOVE
FAULT MIN TRIP ESC EDIT AC POWER X Y Z
SENSITIVE GND BATTERY
Figure 8. Status indicator LEDs.
FREQUENCY TRIP PHASE VOLTAGE
ENTER
VOLTAGE TRIP The DATA PORTS section (Figure 9) on the front operating panel
A B C
LOCKOUT allows for direct connection to a personal computer.
LOCKOUT
ABOVE MIN TRIP
PHASE FAULT
X Y Z ALARM
OPEN ESC EDIT
A B DATA
C PORTS CONTROL
OPEN DATA
CLOSED GROUND FAULTPORTS AC POWER
CLOSED SENSITIVE GND BATTERY
10 www.eaton.com/cooperpowerseries
Form 4D microprocessor-based recloser control and accessories Catalog Data CA280009EN
Effective May 2017
• CLOSE Pushbutton: When pressed, the CLOSE pushbutton Operation upon loss of ac power
returns the control to the initial or home sequence position,
closing the recloser. The control is ready for the start of a new The control is equipped with either an 8 Amp-Hour or 13 Amp-Hour
trip/close sequence. 24 Vdc lead acid battery for operation upon loss of ac power. The
control maintains full operation from the battery for a period of time
• HOT LINE TAG ON/OFF: Hot Line Tag is provided for live-line work dependent upon the battery size:
applications. All closing operations are disabled when the Hot Line
Tag feature is activated. • 8 Amp-Hour – 24 hour (approximate) maximum (20°C)
Hot Line Tag prevents all closing attempts from the control • 13 Amp-Hour – 36 hour maximum (20°C)
and shifts protection to one trip-to-lockout on the composite Control programming settings and parameters – including event
curve of the Hot Line Tag definite time and the TCC1 curve recorder – are stored in non-volatile memory and retained upon loss
(whichever is faster). Hot Line Tag takes precedence over Cold of control power. The time/date clock will continue to operate for
Load Pickup, Non-Reclosing, and Fast Trips Disabled. approximately 30 days after loss of control power.
Hot Line Tag is activated from either the operator panel toggle
switch, local or remote communications, or configurable logic. All Accessories
sources must be off to de-activate Hot Line Tag.
Low-voltage closing
The Hot Line Tag function may only be reset by the source
which initiates it. The Low-Voltage Closing Accessory utilizes 120 or 240 Vac for
closing power. Multiple low-voltage closing accessories are available
One-touch function keys (Figure 11) for reclosers equipped with low voltage closing. The low-voltage
GND TRIP BLOCKED closing accessories available for the Form 4D recloser control
include the appropriate receptacles and wiring based upon the input
The Ground Trip Blocked function blocks all ground sensing in the supply voltage. Tables 4 and 5 list the available low voltage closing
control for the active profile. This ALARM
indicator is illuminated when input/output receptacles and cables for the Form 4D control.
Ground Trip Block is activated from the SCADA port, the interface
software, or locally (via the front panel) causing Incoming power receptacles
CONTROL OK the control to block
all ground sensing. The Incoming Power Receptacle allows the user to conveniently
T NON RECLOSE AC POWER plug the power cable into the control, eliminating the need for
hardwiring to the control. Various options are available based upon
D BATTERY mode when the NON
The control is operating in a non-reclosing the input power voltage and phase sensing requirements. Tables 4
RECLOSE indicator is illuminated. Non-reclosing mode disables any and 5 include the available input receptacles and cables.
automatic reclosing operations. Non-reclosing does not alter the
RIP activeENTER PHASE
TCC. Activation is possible fromVOLTAGE
the SCADA port, the interface Cable locking sleeves
software, or locally (via the front panel). To prevent detachment of the control cable from the control cabinet
SUPERVISORY OFF A B C by unauthorized personnel, a cable-locking sleeve is available to
enclose the cable plug. The plug is passed through the sleeve and
IP ESC EDIT X Y Z
When the SUPERVISORY OFF red indicator is illuminated,
the sleeve is then fastened from inside the control cabinet. There
supervisory commands are blocked. Supervisory functions through
is no access to the cable receptacle without opening the locked
the USB data ports are not blocked. Communications through the
cabinet door and detaching the sleeve. The cable locking sleeves can
front panel USB port remain active independent of the status of
be ordered up to a quantity of five. Refer to Table 7 for the correct
the SUPERVISORY OFF switch. Activation of this function key is
catalog number based on quantity.
restricted to the operator panel. Operational data and metering
information are available while the control is in the SUPERVISORY 120 Vac GFI duplex outlet
OFF position.
The GFI Duplex Outlet is available for controls powered by 120
ALT PROFILE 1 Vac or 240 Vac three-wire supply power. This convenience outlet
DATA PORTS is rated for 3 Amperes and is accessible through the front door in
The Form 4D control has two protection profiles; a normal profile,
and Alternate Profile 1. When the operator panel display lights the control cabinet. The 120 Vac GFI Duplex Outlet can be used
are active and the ALT PROFILE 1 indicator is not illuminated, the for many applications, such as power for the MET Tester, auxiliary
Normal profile is active. Only one profile can be active. measurement equipment, and supplemental lighting. Refer to Table
9 for the catalog number.
BCT terminal block accessory
HOT LINE SUPER- Separate BCT terminal blocks provide a connection point for external
GND TRIP NON
CLOSE TAG BLOCKED RECLOSE
VISORY 600:5 or 1200:5 multi-ratio bushing current transformers. BCT terminal
OFF blocks are available for both the load or source sides and include wire
for all ratios of the BCT. Refer to Table 8.
Auxiliary terminal block accessory
ALT
PROFILE 1 An auxiliary terminal block and receptacle is available for three-stage
OFF auxiliary switch wiring. Refer to Table 8.
www.eaton.com/cooperpowerseries 11
Catalog Data CA280009EN Form 4D microprocessor-based recloser control and accessories
Effective May 2017
Control Cables
For WE, WVE27, WVE38X, VWE, VWVE27, VWVE38X, AC NOVA
18 gauge cable, KA1ME-X KA1ME-X KA1ME-X KA1ME-X KA1ME-X KA1ME-X KA1ME-X KA1ME-X KA1ME-X
10-79 ft length
16 gauge cable, KA18ME-X KA18ME-X KA18ME-X KA18ME-X KA18ME-X KA18ME-X KA18ME-X KA18ME-X KA18ME-X
80-125 ft length
14 gauge cable, KA35ME-X KA35ME-X KA35MX-X KA35ME-X KA35ME-X KA35ME-X KA35ME-X KA35ME-X KA35ME-X
126-200 ft length
For VSA12, VSA12B, VSA16, VSA20, VSA20A, VSO12, VSO16
18 gauge cable, KA1ME-X KA1ME-X KA1ME-X KA1ME-X KA1ME-X KA1ME-X KA1ME-X KA1ME-X KA1ME-X
11-20 ft length
16 gauge cable, KA18ME-X KA18ME-X KA18ME-X KA18ME-X KA18ME-X KA18ME-X KA18ME-X KA18ME-X KA18ME-X
21-35 ft length
14 gauge cable, KA35ME-X KA35ME-X KA35ME-X KA35ME-X KA35ME-X KA35ME-X KA35ME-X KA35ME-X KA35ME-X
36-50 ft length
For DC-NOVA15A, DC-NOVA27A
16 gauge cable, KA1119R6-X KA1119R6-X KA1119R6-X KA1119R6-X KA1119R6-X KA1119R6-X KA1119R6-X KA1119R6-X
11-125 ft length
12 www.eaton.com/cooperpowerseries
Form 4D microprocessor-based recloser control and accessories Catalog Data CA280009EN
Effective May 2017
Table 12. Eaton’s Cooper Power Series Controls-Accessory Cross-Reference Guide (continued)
Form 5
(fixed-panel, Form 6
Form 5 above s/n (above s/n
(swing-panel, 3000 or Form 6 10,000 or
Accessory below s/n beginning (below s/n beginning
Description Form 3A* Form 4C Form FXA Form FXB 3000) with CP57) 10,000) with CP57) Form 4D
Cable-locking sleeves
For control cable, KA614ME1 KME4-56-A KFXA-24-# KFXA-24-# KME5-54-A KME5-54-A KME6-1772-# KME6-1772-# KME4D-1772-#
qty # (max 5)
Terminal Blocks
BCT shorting-type KA1170ME1 KME4-83-1 KME5-61-1 KME5-61-4 KME6-1773-A KME6-1773-A KME4D-1773-A
for bushing 2, 4, 6
BCT shorting-type KA1170ME2 KME4-83-2 KME5-61-2 KME5-61-5 KME6-1773-B KME6-1773-B KME4D-1773-B
for bushing 1, 3, 5
Terminal block KME4-81-1 KME5-62-1 KME5-62-2 KME6-1801-1 KME6-1801-1 KME4D-1801-11
and receptacle for
wiring 3-stage aux
switch KA542R3
Convenience Outlet
Fused 120 Vac, KME5-51-1 KME5-51-4 KME6-1776-A KME6-1776 KME4D-1776
3-wire polarized GFI
convenience outlet
www.eaton.com/cooperpowerseries 13
Catalog Data CA280009EN Form 4D microprocessor-based recloser control and accessories
Effective May 2017
Table 12. Eaton’s Cooper Power Series Controls-Accessory Cross-Reference Guide (continued)
Form 5
(fixed-panel, Form 6
Form 5 above s/n (above s/n
(swing-panel, 3000 or Form 6 10,000 or
Accessory below s/n beginning (below s/n beginning
Description Form 3A* Form 4C Form FXA Form FXB 3000) with CP57) 10,000) with CP57) Form 4D
Automation Packages*
Full Automation KME4D-1774-14
Accessory Package
- Cellular
Full Automation KME4D-1774-15
Accessory Package
- WiFi/WiMAX
Full Automation KME4D-1774-16
Accessory Package
- 125MHz -1GHz
N-terminated radio
Full Automation KME4D-1774-17
Accessory Package
- TNC-terminated
radio, 700MHz -
2GHz
Wireless KME4D-1774-21
communication
package
Polyphaser and KME4D-1774-A
mounting hardware
- 125MHz - 1GHz
Polyphaser and KME4D-1774-B
mounting hardware
- 700MHz - 2GHz
Polyphaser and KME4D-1774-C
mounting hardware
- 2GHz - 6GHz
Miscellaneous Accessories
120 Vac battery KME4-85-1 KME4-85-1 KME5-60-1 KME5-60-1 KME5-60-1 KME5-60-1
charger for spare
batteries
*Form 3A is an analog control, and as such has a myriad accessories that perform functions made standard in the newer digital controls. These accessories are not listed here. For
further clarification, consult an Eaton representative.
14 www.eaton.com/cooperpowerseries
Form 4D microprocessor-based recloser control and accessories Catalog Data CA280009EN
Effective May 2017
www.eaton.com/cooperpowerseries 15