Professional Documents
Culture Documents
.Q1
(أ) أذكر فائدة التعويم الهوائي ( )Air Floationفي معالجة المخلفات الصناعية السائلة .صف طريقة عملها
وما هو العيب الوحيد في هذه األجهزة؟
(ب) المطلوب تصميم أحواض الترسيب االبتدائية من النوع المستطيل الالزمة لمعالج,ة مخلف,ات س,ائلة ص,,ناعية
قدرها 44000م/3يوم ،إذا علمت أن معدل التحميل السطحي لألح,واض= 48م/ي,وم ،م,ع العلم ب,أن نس,بة الط,ول
إلى العرض تساوي 4:1مع افتراض عمق الحوض 3متر.
(c) The industrial zone of Ras Lanuf has been directed to upgrade its wastewater
treatment plant to a secondary plant that can meet an effluent standard of 30 mg/L
BOD5 and 30 mg/L of (SS). They have selected a completely mixed activated sludge
system with MLSS = 2000 mg/L. The effluent BOD 5 was measured as 11.1 mg/L.
Determine the aeration tank volum. The following data are available for the existing
primary plant.
Existing plant effluent characteristics:
Flow = 0.150 m3/s , BOD5 = 84 mg/L
Assume the following values for growth constants: Ks = 100 mg/L , μm = 2.5d-1 ,
Kd = 0.05 d-1, Y = 0.50 , θc = 10 d
.Q2
(أ) تحتوي محطة معالجة مخلفات سائلة صناعية على حوض ترسيب ابتدائي ومرشح بيولوجي.صممت
محطة لمعالجة مخلفات سائلة لها قيمة طلب األكسجين الحيوي = 280ملجم/لتر .كفاءة إزالة BOD5في
كل من حوض الترسيب والمرشح %35و %75على التوالي .أوجد قيمة BOD5للتصريف الخارج من
المحطة ،وأحسب الكفاءة الكلية إلزالة . BOD5
1
( وماهي أهم مكونات المعالجة لهذا النوع من المخلفات ؟ )ب.ماذا نعني بالمخلفات المتالئمة بيئيا
)؟BOD5( وماهي استخدامات نتائج. BOD (ج) اشرح طريقة قياس األكسجين الحيوى الممتص
(d) A high rate aeration system produces 1140 m 3/d. of waste sludge. The sludge is
wasted directly from the aerator has solids content of 3300 mg/L.This sludge is
thickened by dissolved air flotation unit to 3% solids. Determine the volume of
thickened sludge produced each day.
Hint:- V = M/ 1000 . S Where : V= volume of sludge produced m3/d. M = mass of
dry solids. Kg/d. S = solids content expressed as a decimal fraction. 1000 =
density of water, kg/m3
Q3.
(a) Completely mixed activated sludge plant is to treat 10,000 m 3/d of industrial
wastewater .The wastewater has a BOD5 of 1200 mg/L that must be reduced to 200
mg/L prior to discharge to a municipal sewer. Pilot plant analysis indicates that a
mean cell resident time θc of 5 days maintaining MLSS concentration X of 5000
mg/L and underflow concentration Xu of 15000 mg/L. The value for Y is determine
to be 0.70 kg/kg and value of kd is found to be 0.03 d-1. Determine:
i. The volume of the reactor.
ii. The mass and volume of solids waasted each day.
iii. The sludge recirculation ratio.
(c) Design a low-rate filter to treat 6000 m 3/d of industrial sewage of BOD5 of 210
mg/l. The final BOD5 effluent should be 30 mg/l and organic loading rate is 320
g/m3/d. Assume 30% of BOD load removal in primary sedimentation processes,
recirculation ratio constant is 1.0 and filter depth is 1.50 m.
Check the hydraulic loading rate and organic loading rate.
Note: Max. allowable hydraulic loading rate should not more than 4 m/d. and max.
organic loading rate should not more than 320 g/d/m3.
Hint: E1 = 100/ [1+ 0.448(W1 /V1.F1) 0.5]… F1 = (1+r1)/(1+0.1r1) 2
2
Q4.
(أ) " تستعمل المعالجة الكيميائية باألكسدة واالختزال Oxidation/Reductionلتحويل الملوثات السامة
إلى مواد غير ضارة بالبيئة أو إلى مواد أقل ُس مية" تكلم عن مكونات هذه المعالجة و طريقة عملها؟
(ب) .محطة معالجة لمياه الصرف الصناعي تتكون من حوض ترسيب ابتدائي ،يلحقه مرشح بيولوجي
5يبلغ قطره 16م ،وارتفاعه 2.5م .تستقبل المحطة تدفق بمعدل 130م/3ساعة ،وكانت قيمة BOD
للمخلفات الداخلة لحوض الترسيب 170ملجم/لتر ،وكفاءة حوض الترسيب إلزالة 5BODتصل إلى
.%35علمًا بأن نسبة إعادة الدوران تساوي .1.5أوجد التحميل الهيدروليكي ،والتحميل العضوي
للمرشح وكفاءة المرشح ،باستخدام صيغة مجلس األبحاث القومي ( .)NRC
W وزن المواد العضوية المستهلكة
V
= حجم المرشح
معدل الحمل العضوي =
Q معدل التصرف
A
= المساحة
معدل الحمل الهيدروليكي =
(ج) عرف المعالجة الكيميائية .ولماذا تعتبر الذائبية Solubilityعامل مهم وفعال في أي أسلوب من أساليب
المعالجة الكيميائية؟
(d) Determine the BOD5 of the effluent from a low rate trickling filter that has a diameter
of 35 m. and depth of 1.5 m if the flow rate is 1900 m 3/d and the influent BOD5 is 150
mg/L. Assume the rate costant (K) is 2.3 d-1 and n= 0.67
Q St
QL = A , S = exp Qn
o
] [
−KD
L
Where; QL = hydraulic loading rate m/d,
K=rate constant, d-1 ,D =filter depth ,m St = effluent BOD5 mg/L and So = influent
BOD5 mg/L
GOOD LUCK
3