You are on page 1of 12

Previous | Next | Contents

ESDEP WG 3

FABRICATION AND ERECTION

Lecture 3.4: Welding Processes


OBJECTIVE/SCOPE

To review the welding processes commonly used in construction and to highlight some practical
considerations.

PREREQUISITES

Lectures 3.3: Principles of Welding

SUMMARY

This lecture describes the welding processes commonly used in construction: Manual Metal Arc Welding,
Dip and Spray Transfer Metal Active Gas Welding, Submerged Arc Welding and Stud Welding. Each
process is briefly described and its advantages, disadvantages and limitations of use are summarised.
Choice of welding process for a particular situation is discussed.

ABBREVIATIONS

MAG Metal Active Gas Welding (sometimes referred to as MIG: Metal Inert Gas Welding)
MMA Manual Metal Arc Welding
SAW Submerged Arc Welding

1. INTRODUCTION - HEAT SOURCES AND METHODS OF


SHIELDING
There are three principal methods used to generate the heat required for welding:
 oxygen-acetylene flame.
 resistance to the passage of a current.
 electric arc.

Each method produces a pool of molten steel which must be protected against atmospheric contamination.
The method used to achieve this, i.e. the shielding technique, has a major influence on the characteristics
of the process. For constructional steelwork, the processes used are usually based upon the electric arc.
In arc welding, a flux or a non-reactive (inert) gas can be used to 'blanket' the weld pool and thus exclude
air. This lecture is particularly concerned with the four arc welding processes commonly used in structural
work.

2. MANUAL METAL ARC WELDING


This manual method is one of the most widely used arc welding processes (see Figure 1). It requires
considerable skill to produce good quality welds. The electrode consists of a steel core wire and a
covering flux containing alloying elements, e.g. manganese and silicon. The arc melts the parent metal and
the electrode. As metal is transferred from the end of the core wire to the weld pool, the welder moves the
electrode to keep the arc length constant. This is essential as the width of the weld run is largely governed
by the arc length. The flux melts with the core wire and flows over the surface of the pool to form a slag,
which must be removed after solidification.
MMA has many advantages as follows:
 Low capital cost.
 Freedom of movement; it can be used up to 20m from the power supply (useful on site).
 It can be used in all positions.
 It is suitable for structural and stainless steels (but not aluminium).

Its main drawback is a low duty cycle, i.e. only a small volume of metal is deposited before the welder has
to stop and insert another electrode. This is not a problem on short welds but becomes a consideration on
long welds, especially when labour costs are high.
The operating characteristics of the electrode are controlled by the composition of the flux covering. A
variety of electrodes are available to suit different applications. The current used is chosen to match the
diameter of wire being used. When low hydrogen contents in the weld pool are necessary to avoid cracks
in the heat-affected zone (HAZ) on cooling, MMA electrodes must be baked and stored at temperatures
and times recommended by the manufacturer. These procedures ensure that the electrodes deposit weld
metal with appropriate low levels of diffusible hydrogen.

3. METAL ACTIVE GAS (MAG) WELDING


This process is sometimes referred to as Metal Inert Gas (MIG) Welding, although strictly speaking the
term MIG should be limited to the use of pure argon as a shielding gas, which is not used for carbon steel.
MAG is a semi-automatic process where the welding gun at the end of a flexible conduit can be hand held
and manipulated, but all other operations are automatic (see Figure 2).
The arc and weld pool are shielded by a gas which does not react with molten steel; in current practice the
shielding gas is carbon dioxide, or a mixture of argon and carbon dioxide. No flux is necessary to shield
the pool since the alloying elements are in the electrode wire, but sometimes a flux-cored electrode is used
to produce a slag which controls the weld profile and reduces the liability of lack of fusion defects and the
incidence of porosity. The arc length is controlled by the power supply unit. Although MAG welding is
somewhat easier to use than MMA, skill is required to set up the correct welding conditions.
The way in which metal is transferred from the electrode wire to the molten pool depends upon current,
voltage and shielding gas composition. As the current is increased the form of the transfer changes
abruptly to a stream of fine drops which are propelled across the arc gap by the electro-magnetic forces in
the arc. This is called spray transfer and it enables welding to be carried out against gravity. Changing the
shielding gas to carbon dioxide (assuming steel electrodes) causes the transfer to become more globular
and less well directed; however, the situation can be reversed by using a mixture of inert gas and carbon
dioxide.
When using steel electrodes, decreasing the arc voltage markedly and also reducing current (by reducing
the wire feed rate) results in a form of transfer known as dip transfer or short-circuit transfer. In this mode
of transfer metal is fused directly into the pool without passing freely across the arc gap. At slightly higher
voltages the transfer is across a gap but is in larger globules without the pronounced directionality of the
spray transfer. The globular to spray change is less marked with steel than with certain other metals.
Welds in steel are sometimes made in which this type of transfer predominates. It is also possible to
control the type of metal transfer at low to medium currents by using a special power source which
delivers pulsed current to the arc.
For 'positional' welding, i.e. vertical and overhead, the current must be kept below 180 amp (so that
welding takes place in the 'Dip Transfer' mode) and welding speeds are comparable with MMA. Overall
times for a joint, and hence productivity, are better since there is no need to deslag or change electrode. In
the flat position, currents up to 400 amp ('Spray Transfer') can be used to give high welding speeds. MAG
welding is especially suitable for fillet welded joints, e.g. beam to column and stiffener to panel
connections. It is not easy to use on site because of problems of equipment movement and the need to
provide screens to avoid loss of the gas shield in draughty conditions.

4. SUBMERGED ARC WELDING (SAW)


This is a fully mechanised process in which the welding head travels along the joint automatically (Figure
3). The electrode is a bare wire which is advanced by a governed motor. The voltage and current are
selected at the beginning of the weld and are maintained at the pre-selected values by feed-back systems
which, in practice, vary in sophistication. The flux is in the form of particles and is placed on the surface
of the joint. The arc operates below the surface of the flux, melting a proportion of it to form a slag.
Unfused flux is collected and may be re-used for the next weld.
Submerged arc welding is generally operated at currents of between 400 and 1000 amps. This means that
weld pools are large and can only be controlled in the flat position, although fillets can be deposited in the
horizontal-vertical position up to 10mm leg length in one run. Where it is difficult to control penetration in
a root run a backing strip may be used; alternatively, the root run can be made by MMA or MAG and the
groove filled with SAW. SAW offers considerable advantages when welding long joints (i.e. those in
excess of one metre in length). The high welding speeds and continuous operation lead to high
productivity. An accurate joint fit-up is, however, a prime requirement.

5. STUD WELDING
This is a variation of arc welding in which studs are welded to plane surfaces automatically (Figure 4).
The stud, which may be a plain or threaded bar (if plain it will have a head) is the electrode and it is held
in the chuck of a welding gun which is connected to the power supply. The stud is first touched onto the
surface of the steel plate or section. As soon as the current is switched on, the stud is moved away
automatically to establish an arc. When a weld pool has formed and the end of the stud is molten, the latter
is automatically forced into the steel plate and the current is switched off. The molten metal which is
expelled from the interface is formed into a fillet by a ceramic collar which is placed around the stud arc at
the beginning of the operation. This ferrule also provides sufficient protection against atmospheric
contamination.
Stud welding offers an accurate and fast method of attaching shear connectors, etc., with the minimum of
distortion. Whilst it requires some skill to set up the weld parameters (voltage, current, arc time and force),
the operation of the equipment is relatively straightforward.

6. CHOICE OF PROCESS
When choosing a welding process a number of factors must be taken into account:
 Thickness of the material to be welded.
 Where the welding is to be carried out. SAW and MAG are best carried out in the protected
environment of the fabrication shop. MMA may more readily be used on site.
 Accuracy of fit-up and possibility of misalignment. SAW and Spray Transfer MAG require good
fit-up; they are particularly sensitive to variation in root gap and/or root face dimensions.
 Access to joint. It is necessary to ensure that both the welding plant and the welding torch or head
can be properly positioned.
 Position of welding. SAW and Spray Transfer MAG are not suitable for vertical or overhead
positions. Dip transfer MAG is acceptable for vertical and overhead welding, but MMA is
probably best for overhead work, especially on site.
 Steel composition. Steels with lower carbon equivalent values are more readily welded and require
lower preheat levels.
 Comparative cost. The cost per unit length of weld can be calculated, but depends upon the burn-
off rate of the process and must allow for differences in duty cycle (idle time between electrodes
for MMA, etc.), Figure 5.

7. CONCLUDING SUMMARY
 The welding processes commonly used in constructional steelwork are: Manual Metal Arc
Welding, Dip and Spray Transfer Metal Active Gas Welding, Submerged Arc Welding and Stud
Welding.
 Stud welding is used for attaching shear connectors and other studs to structural steelwork.
 The correct choice of process depends on: situation, fit-up, access, position, steel composition and
economic factors.

8. ADDITIONAL READING
1. Gourd, L. M., "Principles of Welding Technology", E. Arnold, 1980.

 description of processes.

2. Houldcroft, P. T., and Robert, "Welding and Cutting - A Guide to Fusion Welding and Associated
Cutting Processes", Woodhead and Faulkner, 1988.

 details of individual processes.

3. Structural Welding Code - Steel, American Welding Society, 1992.


4. EN 24063: 1992 (ISO 4063: 1990) Welding, Brazing, Soldering and Braze Welding of Metals -
Nomenclature of Processes and Reference of Numbers for Symbolic Representation on Drawings.
5. EN 288: Part 1: 1992, Welding Procedures Metallic Materials, Part 1: General Rules for Fusion
Welding.
6. EN 288: Part 2: 1992, Welding Procedures Metallic Materials, Part 2: Welding Procedure
Specification for Arc Welding.
7. EN 288: Part 3: 1992, Welding Procedures Metallic Materials, Part 3: Welding Procedure Tests for
Arc Welding of Steels.
8. EN 288: Part 4: 1992, Welding Procedures Metallic Materials, Part 4: Tests for the Arc Welding of
Aluminium and its Alloys.
9. Pratt, J. L., "Introduction to the Welding of Structural Steelwork", SCI P-014, 3rd Revised Edition,
1989, Steel Construction Institute.

Previous | Next | Contents